Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “computed tomography”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

Comparing Effective Doses During Image-Guided Core Needle Biopsies with Computed Tomography Versus C-Arm Cone Beam CT Using Adult and Pediatric Phantoms

PurposeTo compare the effective doses of needle biopsies based on dose measurements and simulations using adult and pediatric phantoms, between cone beam c-arm CT (CBCT) and CT.MethodEffective doses were calculated and compared based on measurements and Monte Carlo simulations of CT- and CBCT-guided biopsy procedures of the lungs, liver, and kidney using pediatric and adult phantoms.ResultsThe effective doses for pediatric and adult phantoms, using our standard protocols for upper, middle and lower lungs, liver, and kidney biopsies, were significantly lower under CBCT guidance than CT. The average effective dose for a 5-year old for these five biopsies was 0.36 ± 0.05 mSv with the standard CBCT exposure protocols and 2.13 ± 0.26 mSv with CT. The adult average effective dose for the five biopsies was 1.63 ± 0.22 mSv with the standard CBCT protocols and 8.22 ± 1.02 mSv using CT. The CT effective dose was higher than CBCT protocols for child and adult phantoms by 803 and 590 % for upper lung, 639 and 525 % for mid-lung, and 461 and 251 % for lower lung, respectively. Similarly, the effective dose was higher by 691 and 762 % for liver and 513 and 608 % for kidney biopsies.ConclusionsBased on measurements and simulations with pediatric and adult phantoms, radiation effective doses during image-guided needle biopsies of the lung, liver, and kidney are significantly lower with CBCT than with CT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Radiation Exposure of Interventional Radiologists During Computed Tomography Fluoroscopy-Guided Renal Cryoablation and Lung Radiofrequency Ablation: Direct Measurement in a Clinical Setting

IntroductionComputed tomography (CT) fluoroscopy-guided renal cryoablation and lung radiofrequency ablation (RFA) have received increasing attention as promising cancer therapies. Although radiation exposure of interventional radiologists during these procedures is an important concern, data on operator exposure are lacking.Materials and MethodsRadiation dose to interventional radiologists during CT fluoroscopy-guided renal cryoablation (n = 20) and lung RFA (n = 20) was measured prospectively in a clinical setting. Effective dose to the operator was calculated from the 1-cm dose equivalent measured on the neck outside the lead apron, and on the left chest inside the lead apron, using electronic dosimeters. Equivalent dose to the operator’s finger skin was measured using thermoluminescent dosimeter rings.ResultsThe mean (median) effective dose to the operator per procedure was 6.05 (4.52) μSv during renal cryoablation and 0.74 (0.55) μSv during lung RFA. The mean (median) equivalent dose to the operator’s finger skin per procedure was 2.1 (2.1) mSv during renal cryoablation, and 0.3 (0.3) mSv during lung RFA.ConclusionRadiation dose to interventional radiologists during renal cryoablation and lung RFA were at an acceptable level, and in line with recommended dose limits for occupational radiation exposure.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Combined Static and Dynamic Computed Tomography Angiography of Peripheral Artery Occlusive Disease: Comparison with Magnetic Resonance Angiography

PurposeTo compare in patients with known peripheral artery occlusive disease (PAOD), image quality of a combined CTA to a combined MRA protocol, including both static and dynamic acquisitions.Materials and MethodsTwenty-two patients with PAOD were examined with a combined CTA and MRA protocol consisting of static acquisitions (s-CTA, s-MRA) of the entire runoff and dynamic acquisitions (d-CTA, d-MRA) of the calves. Two radiologists compared image quality of the s-MRA versus s-CTA as well as d-MRA versus d-CTA. Image quality was assessed on a segmental basis using a 4-point Likert scale.ResultsFor s-CTA, 76% of segments were rated as excellent or good. For s-MRA, 50% of segments were rated as excellent or good (p < 0.0001). For d-CTA, median image quality score for all segments was rated as excellent for both readers. For d-MRA, median image quality for the different segments ranged from moderate to good. For both d-CTA and d-MRA, the median image quality scores were significantly higher for all segments of the lower limb compared with the static examinations of the lower limb segments (all p values < 0.0001). In patients with PAOD category 4–6, 80% of segments were rated as excellent or good for d-CTA, while 45% of segments were rated as poor or non-diagnostic for d-MRA.ConclusionIn patients with known PAOD, a combined static and dynamic CTA examination improves image quality relative to static and dynamic MRA and should be considered as an alternative to MRA, particularly in patients with advanced stage PAOD.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Computer-Aided Diagnosis of Lung Nodules in Computed Tomography by Using Phylogenetic Diversity, Genetic Algorithm, and SVM

Lung cancer is pointed as the major cause of death among patients with cancer throughout the world. This work is intended to develop a methodology for diagnosis of lung nodules using images from the Image Database Consortium and Image Database Resource Initiative (LIDC-IDRI). The proposed methodology uses image processing and pattern recognition techniques. In order to differentiate between the patterns of malignant and benign nodules, we used phylogenetic diversity by means of particular indexes, that are: intensive quadratic entropy, extensive quadratic entropy, average taxonomic distinctness, total taxonomic distinctness, and pure diversity indexes. After that, we applied the genetic algorithm for selection of the best model. In the tests’ stage, we applied the proposed methodology to 1405 (394 malignant and 1011 benign) nodules. The proposed work presents promising results at the classification into malignant and benign, achieving accuracy of 92.52%, sensitivity of 93.1% and specificity of 92.26%. The results demonstrated a good rate of correct detections using texture features. Since a precocious detection allows a faster therapeutic intervention, thus a more favorable prognostic to the patient, we propose herein a methodology that contributes to the area in this aspect.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Cardiac Computed Tomography (CT) Evaluation of Valvular Heart Disease in Transcatheter Interventions

Purpose of Review: To establish the actual role of CT in the growing field of transcatheter valve interventions (THV). Recent Findings: The development of empirical CT measurements, which are linked with outcomes. Summary: CT is a reliable technique for assessing risk and planning transcatheter valve interventions for mitral and aortic valves. Pulmonic and tricuspid valve assessment with CT imaging is still in the early stages but there is room for development.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A closer look at corrosion of steel reinforcement bars in concrete using 3D neutron and X-ray computed tomography

Corrosion of reinforcing bars constitutes the largest threat to the durability of concrete structures. Thus, several studies have investigated the nature of the corrosion products, most using post-mortem analyses. However, corrosion products evolve when in contact with oxygen, hindering result interpretation. This work presents instead a state-of-the-art, non-destructive 3D method for the assessment of corrosion of embedded reinforcements. Multimodal neutron and X-ray tomography was used to observe, non-destructively, the characteristics of the corrosion products in two concrete samples, with the aim of investigating possible benefits of the use of this technique for reinforced concrete structures. One sample was naturally corroded, extracted from an 81-year-old bridge, the other was corroded via the galvanostatic method, resulting in corrosion-induced cracks. Quantitative and qualitative data was acquired, including the iron-to-rust volumetric ratio in macroscopic interfacial voids and the thickness of the corrosion layer at the steel concrete interface. The iron-to-rust volumetric ratio corresponded to large, soluble, corrosion products, forming in environments with low availability of oxygen for both samples.

36 MATERIALS SCIENCE↗

Quantitative microstructural investigation of 3D-printed and cast cement pastes using micro-computed tomography and image analysis

Highlights: • Processing alters the microstructure in 3D-printed lamellar cubic element. • A unique patterned and connected pore microstructure network exists. • Micro-channels are connected through micro-pores present at interfaces regions. • Three distinct pore volume domains exists in hardened microstructure. • Volume and frequency of pore, hydrated, and unhydrated clusters are dissimilar. Microstructural phases and mechanical properties of lamellar 3D-printed and cast hardened cement paste (hcp) elements were investigated using a lab-based X-ray microscope at two levels of magnification (0.4× and 4×). K-means clustering was used for quantitative image analysis. The entire volume of intact 3-days-old 3D-printed and cast hcp elements was characterized at 0.4× magnification. Three microstructural features (macro-pores, micro-channels, and interfacial micro-pores) were found to reside in three distinct pore size domains. The largest pores of the 3D-printed element were larger than the largest pores of the reference cast hcp element. Moreover, the smallest pore sizes of the 3D-printed element were found to be smaller than those present in the cast counterparts. Micro-channels were found to be connected to one another through the micro-pores present at interfacial regions, indicating the presence of a uniquely patterned and interconnected pore network. The role of locally weak and porous interfaces on mechanical response and fracture properties is discussed.

36 MATERIALS SCIENCE↗