Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “coherence imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

Synthetic-aperture radar (SAR) imaging with range-resolved reflection data

SAR imaging may be performed with range-resolved reflection data, where a spread-spectrum signal, such as a code division multiple access (CDMA) signal, is transmitted instead of a simple frequency chirp. The reflected spread-spectrum signal may be analyzed to gather range-resolved reflection data. Range-resolved reflection data may be gathered at each angular view. This data may be used to construct a more accurate approximation of the Fourier transform of the desired image than can be done by a conventional SAR approach. The image may be reconstructed from this Fourier transform using Fourier inversion techniques similar to those used in conventional SAR approaches. The range-resolved reflection scheme generally requires somewhat more processing to recover the image as compared with conventional SAR systems, but provides a significantly more stable image with less degradation from effects that plague conventional SAR systems. This can eliminate the need for phase coherency altogether and also eliminate “phase drift,” which leads to image distortion. This may be especially well suited for high resolution imaging of relatively large targets.

47 OTHER INSTRUMENTATION↗

Perceiving the coherent movements of spatially-separated features

When a partially-occluded object is represented in an image, it is defined by a set of spatially-separated features that may be registered at different spatial scales. To understand the image, human vision must organize these fragmented optical features into common and distinct object surfaces. Although the common fate of moving features often is considered a primary source of reliable information for image segmentation, little is known of the visual system's capacity to discriminate the coherent relative movements of spatially-separated features. In a series of experiments, observers viewed elements whose movements were correlated (direction and magnitude) or were uncorrelated. Our results indicate that observers can discriminate the two types of movement about as well as they can detect any movement at all. Moreover, the ability to perceive coherent movements is maintained under a variety of conditions including differences in the elements' spatial frequency content, spatial position and contrast, and temporal phase shifts between the spatially-correlated displacements. These results suggest that coherent relative motion may be a fundamental source of information exploited by vision, despite considerable variability in the spatial and temporal characteristics of the individual features.

Mowafy, Lyn↗

Femtosecond Diffractive Imaging with a Soft-X-Ray Free-Electron Laser

Theory predicts that with an ultrashort and extremely bright coherent X-ray pulse, a single diffraction pattern may be recorded from a large macromolecule, a virus, or a cell before the sample explodes and turns into a plasma. Here we report the first experimental demonstration of this principle using the FLASH soft X-ray free-electron laser. An intense 25 fs, 4 x 10{sup 13} W/cm{sup 2} pulse, containing 10{sup 12} photons at 32 nm wavelength, produced a coherent diffraction pattern from a nano-structured non-periodic object, before destroying it at 60,000 K. A novel X-ray camera assured single photon detection sensitivity by filtering out parasitic scattering and plasma radiation. The reconstructed image, obtained directly from the coherent pattern by phase retrieval through oversampling, shows no measurable damage, and extends to diffraction-limited resolution. A three-dimensional data set may be assembled from such images when copies of a reproducible sample are exposed to the beam one by one.

Other,PHYS↗

Planetary Radar Imaging with the Deep-Space Network's 34 Meter Uplink Array

A coherent Uplink Array consisting of two or three 34-meter antennas of NASA's Deep Space Network has been developed for the primary purpose of increasing EIRP at the spacecraft. Greater EIRP ensures greater reach, higher uplink data rates for command and configuration control, as well as improved search and recovery capabilities during spacecraft emergencies. It has been conjectured that Doppler-delay radar imaging of lunar targets can be extended to planetary imaging, where the long baseline of the uplink array can provide greater resolution than a single antenna, as well as potentially higher EIRP. However, due to the well known R4 loss in radar links, imaging of distant planets is a very challenging endeavor, requiring accurate phasing of the Uplink Array antennas, cryogenically cooled low-noise receiver amplifiers, and sophisticated processing of the received data to extract the weak echoes characteristic of planetary radar. This article describes experiments currently under way to image the planets Mercury and Venus, highlights improvements in equipment and techniques, and presents planetary images obtained to date with two 34 meter antennas configured as a coherently phased Uplink Array.

uplink array↗

X-ray microscopy and talbot imaging with the matter in extreme conditions X-ray imager at LCLS

The last decade has shown the great potential that X-ray Free Electron Lasers (FEL) have to study High Energy Density (HED) physics. Experiments at FELs have made significant breakthroughs in Shock Physics and Dynamic Diffraction, Dense Plasma Physics and Warm Dense Matter Science, using techniques such as isochoric heating, inelastic scattering, small angle scattering and X-ray diffraction. In addition, and complementary to these techniques, the coherent properties of the FEL beam can be used to image HED samples with high fidelity. We present new imaging diagnostics and techniques developed at the Matter in Extreme Conditions (MEC) instrument at Linac Coherent Light Source (LCLS) over the last few years. We show results in Phase Contrast Imaging geometry, where the X-ray beam propagates from the target to a camera revealing its phase, as well as in Direct Imaging geometry, where a real image of the sample plane is produced in the camera with a spatial resolution down to 200 nm. Last, we show an implementation of the Talbot Imaging method allowing both X-ray phase and intensity measurements change introduced by a target with sub-micron resolution.

47 OTHER INSTRUMENTATION↗

X-ray free-electron laser based dark-field X-ray microscopy: a simulation-based study

Dark-field X-ray microscopy (DFXM) is a nondestructive full-field imaging technique providing three-dimensional mapping of microstructure and local strain fields in deeply embedded crystalline elements. This is achieved by placing an objective lens in the diffracted beam, giving a magnified projection image. So far, the method has been applied with a time resolution of milliseconds to hours. In this work, the feasibility of DFXM at the picosecond time scale using an X-ray free-electron laser source and a pump–probe scheme is considered. Thermomechanical strain-wave simulations are combined with geometrical optics and wavefront propagation optics to simulate DFXM images of phonon dynamics in a diamond single crystal. Using the specifications of the XCS instrument at the Linac Coherent Light Source as an example results in simulated DFXM images clearly showing the propagation of a strain wave.

47 OTHER INSTRUMENTATION↗

Coherence revivals in two-photon frequency combs

We describe and theoretically analyze the self-imaging Talbot effect of entangled photon pairs in the time domain. Rich phenomena are observed in coherence propagation along dispersive media of mode-locked two-photon states with frequency entanglement exhibiting a comblike correlation function. Our results can be used to remotely transfer frequency standards through optical fiber networks with two-photon light, avoiding the requirement of dispersion compensation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Necessary Experimental Conditions for Single-Shot Diffraction Imaging of DNA-Based Structures with X-ray Free-Electron Lasers

It has been proposed that the radiation damage to biological particles and soft condensed matter can be overcome by ultrafast and ultraintense X-ray free-electron lasers (FELs) with short pulse durations. The successful demonstration of the “diffraction-before-destruction” concept has made single-shot diffraction imaging a promising tool to achieve high resolutions under the native states of samples. However, the resolution is still limited because of the low signal-to-noise ratio, especially for biological specimens such as cells, viruses, and macromolecular particles. Here, we present a demonstration single-shot diffraction imaging experiment of DNA-based structures at SPring-8 Angstrom Compact Free Electron Laser (SACLA), Japan. Through quantitative analysis of the reconstructed images, the scattering abilities of gold and DNA were demonstrated. Suggestions for extracting valid DNA signals from noisy diffraction patterns were also explained and outlined. To sketch out the necessary experimental conditions for the 3D imaging of DNA origami or DNA macromolecular particles, we carried out numerical simulations with practical detector noise and experimental geometry using the Linac Coherent Light Source (LCLS) at the SLAC National Accelerator Laboratory, USA. In conclusion, the simulated results demonstrate that it is possible to capture images of DNA-based structures at high resolutions with the technique development of current and next-generation X-ray FEL facilities.

59 BASIC BIOLOGICAL SCIENCES↗

High-resolution phase-contrast imaging of biological specimens using a stable betatron X-ray source in the multiple-exposure mode

Abstract Phase-contrast imaging using X-ray sources with high spatial coherence is an emerging tool in biology and material science. Much of this research is being done using large synchrotron facilities or relatively low-flux microfocus X-ray tubes. An alternative high-flux, ultra-short and high-spatial-coherence table-top X-ray source based on betatron motions of electrons in laser wakefield accelerators has the promise to produce high quality images. In previous phase-contrast imaging studies with betatron sources, single-exposure images with a spatial resolution of 6–70 μ m were reported by using large-scale laser systems (60–200 TW). Furthermore, images obtained with multiple exposures tended to have a reduced contrast and resolution due to the shot-to-shot fluctuations. In this article, we demonstrate that a highly stable multiple-exposure betatron source, with an effective average source size of 5 μ m, photon number and pointing jitters of <5% and spectral fluctuation of <10%, can be obtained by utilizing ionization injection in pure nitrogen plasma using a 30–40 TW laser. Using this source, high quality phase-contrast images of biological specimens with a 5- μ m resolution are obtained for the first time. This work shows a way for the application of high resolution phase-contrast imaging with stable betatron sources using modest power, high repetition-rate lasers.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Spatial coherence effect on layer thickness determination in narrowband full-field optical coherence tomography

Longitudinal spatial coherence (LSC) is determined by the spatial frequency content of an optical beam. The use of lenses with a high numerical aperture (NA) in full-field optical coherence tomography and a narrowband light source makes the LSC length much shorter than the temporal coherence length, hence suggesting that high-resolution 3D images of biological and multilayered samples can be obtained based on the low LSC. A simplified model is derived, supported by experimental results, which describes the expected interference output signal of multilayered samples when high-NA lenses are used together with a narrowband light source. An expression for the correction factor for the layer thickness determination is found valid for high-NA objectives. Additionally, the method was applied to a strongly scattering layer, demonstrating the potential of this method for high-resolution imaging of scattering media.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Structural Changes as a Function of Thickness in [(SnSe) 1+δ ] m TiSe 2 Heterostructures

Single- and few-layer metal chalcogenide compounds are of significant interest due to structural changes and emergent electronic properties on reducing dimensionality from three to two dimensions. To explore dimensionality effects in SnSe, a series of [(SnSe) 1+δ ] m TiSe 2 intergrowth structures with increasing SnSe layer thickness (m = 1-4) were prepared from designed thin-film precursors. In-plane diffraction patterns indicated that significant structural changes occurred in the basal plane of the SnSe constituent as m is increased. Scanning transmission electron microscopy cross-sectional images of the m = 1 compound indicate long-range coherence between layers, whereas the m >/= 2 compounds show extensive rotational disorder between the constituent layers. For m >/= 2, the images of the SnSe constituent contain a variety of stacking sequences of SnSe bilayers. Density functional theory calculations suggest that the formation energy is similar for several different SnSe stacking sequences. The compounds show unexpected transport properties as m is increased, including the first p-type behavior observed in (MSe)m(TiSe 2 ) n compounds. The resistivity of the m >/- 2 compounds is larger than for m = 1, with m = 2 being the largest. At room temperature, the Hall coefficient is positive for m = 1 and negative for m = 2-4. The Hall coefficient of the m = 2 compound changes sign as temperature is decreased. The room-temperature Seebeck coefficient, however, switches from negative to positive at m = 3. These properties are incompatible with single band transport indicating that the compounds are not simple composites.

36 MATERIALS SCIENCE↗

Ultralow-threshold, continuous-wave upconverting lasing from subwavelength plasmons

Miniaturized lasers are an emerging platform for generating coherent light for quantum photonics, in vivo cellular imaging, solid-state lighting and fast three-dimensional sensing in smartphones. Continuous-wave lasing at room temperature is critical for integration with opto-electronic devices and optimal modulation of optical interactions. Plasmonic nanocavities integrated with gain can generate coherent light at subwavelength scales, beyond the diffraction limit that constrains mode volumes in dielectric cavities such as semiconducting nanowires. However, insufficient gain with respect to losses and thermal instabilities in nanocavities has limited all nanoscale lasers to pulsed pump sources and/or low-temperature operation. Here, we show continuous-wave upconverting lasing at room temperature with record-low thresholds and high photostability from subwavelength plasmons. We achieve selective, single-mode lasing from Yb 3+ /Er 3+ -co-doped upconverting nanoparticles conformally coated on Ag nanopillar arrays that support a single, sharp lattice plasmon cavity mode and greater than wavelength λ/20 field confinement in the vertical dimension. The intense electromagnetic near-fields localized in the vicinity of the nanopillars result in a threshold of 70 W cm -2 , orders of magnitude lower than other small lasers. Our plasmon-nanoarray upconverting lasers provide directional, ultra-stable output at visible frequencies under near-infrared pumping, even after six hours of constant operation, which offers prospects in previously unrealizable applications of coherent nanoscale light.

36 MATERIALS SCIENCE↗

Optical communication with two-photon coherent states. III - Quantum measurements realizable with photoemissive detectors

Homodyne detection is shown to achieve the same signal-to-noise ratio as the quantum field quadrature measurement, thus providing a receiver which realizes linear modulation TCS performance gain. The full equivalence of homodyne detection and single-quadrature field measurement is established. A heterodyne configuration which uses a TCS image-band oscillator in addition to the usual coherent state local oscillator is studied. Results are obtained by means of a representation theorem which shows that photoemissive detection realizes the photon flux density measurement.

Yuen, H. P.↗

Phase Contrast Imaging with Coded Apertures Using Laboratory-Based X-ray Sources

X-ray phase contrast imaging is a powerful technique that allows detection of changes in the phase of x-ray wavefronts as they pass through a sample. As a result, details not visible in conventional x-ray absorption imaging can be detected. Until recently the majority of applications of phase contrast imaging were at synchrotron facilities due to the availability of their high flux and coherence; however, a number of techniques have appeared recently that allow phase contrast imaging to be performed using laboratory sources. Here we describe a phase contrast imaging technique, developed at University College London, that uses two coded apertures. The x-ray beam is shaped by the pre-sample aperture, and small deviations in the x-ray propagation direction are detected with the help of the detector aperture. In contrast with other methods, it has a much more relaxed requirement for the source size (it works with source sizes up to 100 {mu}m). A working prototype coded-aperture system has been built. An x-ray detector with directly deposited columnar CsI has been used to minimize signal spill-over into neighboring pixels. Phase contrast images obtained with the system have demonstrated its effectiveness for imaging low-absorption materials.

07 ISOTOPE AND RADIATION SOURCES↗

Emission of coherent THz-radiation from superconductors.

Compact solid-state sources of terahertz (THz) radiation are being sought for sensing, imaging, and spectroscopy applications across the physical and biological sciences. We demonstrate that coherent continuous-wave THz radiation of sizable power can be extracted from intrinsic Josephson junctions in the layered high-temperature superconductor Bi{sub 2}Sr{sub 2}CaCu{sub 2}O{sub 8}. In analogy to a laser cavity, the excitation of an electromagnetic cavity resonance inside the sample generates a macroscopic coherent state in which a large number of junctions are synchronized to oscillate in phase. The emission power is found to increase as the square of the number of junctions reaching values of 0.5 microwatt at frequencies up to 0.85 THz, and persists up to 50 kelvin. These results should stimulate the development of superconducting compact sources of THz radiation.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Coherent Doppler lidar for automated space vehicle, rendezvous, station-keeping and capture

Recent advances in eye-safe, short wavelength solid-state lasers offer real potential for the development of compact, reliable, light-weight, efficient coherent lidar. Laser diode pumping of these devices has been demonstrated, thereby eliminating the need for flash lamp pumping, which has been a major drawback to the use of these lasers in space based applications. Also these lasers now have the frequency stability required to make them useful in coherent lidar, which offers all of the advantages of non-coherent lidar, but with the additional advantage that direct determination of target velocity is possible by measurement of the Doppler shift. By combining the Doppler velocity measurement capability with the inherent high angular resolution and range accuracy of lidar it is possible to construct Doppler images of targets for target motion assessment. A coherent lidar based on a Tm,Ho:YAG 2-micrometer wavelength laser was constructed and successfully field tested on atmospheric targets in 1990. This lidar incorporated an all solid state (laser diode pumped) master oscillator, in conjunction with a flash lamp pumped slave oscillator. Solid-state laser technology is rapidly advancing, and with the advent of high efficiency, high power, semiconductor laser diodes as pump sources, all-solid-state, coherent lidars are a real possibility in the near future. MSFC currently has a feasibility demonstration effort under way which will involve component testing, and preliminary design of an all-solid-state, coherent lidar for automatic rendezvous, and capture. This two year effort, funded by the Director's Discretionary Fund is due for completion in 1992.

Dunkin, James A.↗

Diffraction image formation in optical systems with polarization aberrations. II - Amplitude response matrices for rotationally symmetric systems

In the previous paper in this series (McGuire and Chipman, 1990), a formulation was established for the calculation and analysis of diffraction image quality in polarizing optical systems illuminated with partially polarized, partially coherent light. In the present paper, the effect of second- and fourth-order polarization aberrations on the image plane diffraction patterns are examined. The amplitude response matrix is calculated for optical systems with small numerical apertures. Numerical results are presented for optical systems with circular apertures for three of the aberration types.

Mcguire, James P., Jr.↗