Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “camera”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

Systems and methods of adaptive two-wavelength single-camera imaging thermography (ATSIT) for accurate and smart in-situ process temperature measurement during metal additive manufacturing

A two-wavelength, single-camera imaging thermography system for in-situ temperature measurement of a target, comprising: a target light path inlet conduit for receiving a target light beam reflected from the target; a beam splitter installed in a splitter housing at a distal end of the target light path conduit, wherein the beam splitter divides the target light beam into a first light beam and a second light beam; a first light path conduit emanating from the splitter housing comprising a first aperture iris installed within the first light path conduit for aligning the first light beam; a first band pass filter installed within the first light path conduit for regulating the first light beam to a first wavelength λ1 and an optional half waveplate installed within the first light path conduit to modulate a polarization ratio of the first light beam of λ1 wavelength; a second light path conduit emanating from the splitter housing comprising a second aperture iris installed within the second light path conduit for aligning the second light beam; a second band pass filter installed within the second light path conduit for regulating the second light beam to a second wavelength λ2; a junction housing, wherein distal ends of each of the first and second light path conduits are connected to the junction housing; a polarizing beam splitter installed in the junction housing, wherein the polarizing beam splitter reflects the first light beam of λ1 wavelength along the same path or a parallel path of the second light beam of λ2 wavelength that passes directly through the polarizing beam splitter unreflected to create a merged light beam comprising light of λ1 and λ2 wavelengths; and a light path outlet conduit connected to the junction for directing the merged beam to a high-speed camera for imaging.

Zhao, Xiayun↗

ON THE ACCURACY OF MEASUREMENTS MADE UPON FILMS PHOTOGRAPHED BY BAKER-NUNN SATELLITE TRACKING CAMERAS

The photographs taken by the Baker-Nunn cameras of the Smithsonian Astrophysical Observatory were formerly measured with Van Biesbroeck goniometers, but are now measured exclusively with Mann two-screw comparators. Instead of measuring point images, we usually have to measure oblong images, either trails or breaks (the latter produced by interruption of the exposure). We can therefore expect that the accuracy of the determination of their positions is more influenced by the personal errors than it is in conventional astrometry. Approximately 800 measurements were made on 34 images of different length, and, from these, the frequency distribution of settings was determined. Then the relationship between this distribution and the length of the image (trail or break) was examined, and the relationship between the "magnitude error" and the length of image was determined. Measurements were made at different angles formed by the trails and the reticle lines, and it was found that the accuracy was not affected by the angle of the setting. Position determinations have been made using reference stars at different distances. On the basis of these results, we can conclude that the accuracy is neither influenced by the distortion of the emulsion nor by the optical distortion within an area of a diameter of S cm (5°.8). We believe that we are justified in using the linear plate constant method, at least within this area. From numerous double and multiple measurements, the following standard errors were determined for a single position.

ASTROMETRY↗

A Single Chip CMOS APS Digital Camera

A complete programmable digital camera-on-a-chip based on low power active pixel sensor technology is implemented as a single CMOS integrated circuit.

imaging sensor camera-on-a-chip digital camera↗

ProxiScan™: A Novel Camera for Imaging Prostate Cancer

ProxiScan is a compact gamma camera suited for high-resolution imaging of prostate cancer. Developed by Brookhaven National Laboratory and Hybridyne Imaging Technologies, Inc., ProxiScan won a 2009 R&D 100 Award, sponsored by R&D Magazine to recognize the top 100 technological achievements of the year.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SNAPSHOT USA 2020: A second coordinated national camera trap survey of the United States during the COVID-19 pandemic

Managing wildlife populations in the face of global change requires regular data on the abundance and distribution of wild animals, but acquiring these over appropriate spatial scales in a sustainable way has proven challenging. Here, in this study, we present the data from Snapshot USA 2020, a second annual national mammal survey of the USA. This project involved 152 scientists setting camera traps in a standardized protocol at 1485 locations across 103 arrays in 43 states for a total of 52,710 trap-nights of survey effort. Most (58) of these arrays were also sampled during the same months (September and October) in 2019, providing a direct comparison of animal populations in 2 years that includes data from both during and before the COVID-19 pandemic. All data were managed by the eMammal system, with all species identifications checked by at least two reviewers. In total, we recorded 117,415 detections of 78 species of wild mammals, 9236 detections of at least 43 species of birds, 15,851 detections of six domestic animals and 23,825 detections of humans or their vehicles. Spatial differences across arrays explained more variation in the relative abundance than temporal variation across years for all 38 species modeled, although there are examples of significant site-level differences among years for many species. Temporal results show how species allocate their time and can be used to study species interactions, including between humans and wildlife. These data provide a snapshot of the mammal community of the USA for 2020 and will be useful for exploring the drivers of spatial and temporal changes in relative abundance and distribution, and the impacts of species interactions on daily activity patterns. There are no copyright restrictions, and please cite this paper when using these data, or a subset of these data, for publication.

54 ENVIRONMENTAL SCIENCES↗

Infrared MBE-Grown HgCdTe Focal Plane Arrays and Cameras After High Energy Neutron Irradiation

HgCdTe is one of the most important materials for the fabrication of infrared detectors and focal plane arrays (FPAs) deployed in environments where high-energy particles, such as protons and neutrons, are present. We designed and fabricated HgCdTe-based FPAs that can be used in high neutron radiation environments and we measured their characteristics. The influence of the radiation on the infrared FPAs and cameras is investigated. HgCdTe material and devices are capable of maintaining high performances in a high energy neutron irradiation environment. For MWIR FPA directly facing a $2.59 × 10^8$ n/cm$^2$ s neutron flux beam (with the highest energy 66 MeV) for 1 h, the noise equivalent differential temperature (NEDT) increased ~8 times after irradiation. However, NEDT decreased to 33 mK (compared to the original value of 21 mK) after one warming-up (to room temperature) and cooling-down cycle. The NEDT for the MWIR FPAs mounted parallel to the beam did not degrade (16 mK and 28 mK before irradiation, changed to 18 mK and 26 mK after irradiation, respectively).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design and performance of a large area neutron sensitive anger camera

We describe the design and performance of a 157mm x 157mm two dimensional neutron detector. The detector uses the Anger principle to determine the position of neutrons. We have verified FWHM resolution of < 1.2mm with distortion < 0.5mm on over 50 installed Anger Cameras. The performance of the detector is limited by the light yield of the scintillator, and it is estimated that the resolution of the current detector could be doubled with a brighter scintillator. Data collected from small (<1mm 3 ) single crystal reference samples at the single crystal instrument TOPAZ provide results with low R w (F) values

42 ENGINEERING↗

Energy resolved soft x-ray imaging using a charge coupled device camera for long pulse discharges in the Large Helical Device

Energy resolved soft x-ray imaging system using a charge coupled device camera and a multifilter disk has recently been installed to the Large Helical Device for the measurements in the long pulse discharges. Eight images with different cutoff energies are measured sequentially during a single discharge by rotating a filter disk mounting eight beryllium filters with different thicknesses. A tangential line-integrated profile for a specific photon energy range can be obtained by taking intensity difference between two images measured with a filter pair of adjacent thicknesses. The typical photon energy corresponding to each difference ranges from 1.9 to 4.8 keV with the bandwidth of 2-3 keV. In the initial results, the difference in the line-integrated soft x-ray profile by the energy range has been clearly observed. This diagnostic method can possibly be applied to the observation of the dependence of two dimensional soft x-ray profile on photon energy range especially if local non-Maxwellian component appears in electron energy distribution function.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

One-dimensional and multichannels multi-imaging x-ray streak camera for imploded core plasma of shell-cone target

Recently one-dimensional and multichannels multi-imaging x-ray streak camera (1D+McMIXS) has been proposed as an ultrafast diagnostic tool for imploded core plasma of shell-cone target. This diagnostic system can provide much more information of core plasma dynamics, such as the shell trajectory before the maximum compression, two dimensional (2D) x-ray images, and 2D map of electron temperature. The 1D+McMIXS was used in an implosion experiment of a shell target with a cone for fast ignition at Gekko XII laser facility. The interaction between the core plasma and the tip of the cone was observed and revealed some detailed structures. A series of time-resolved 2D x-ray images were reconstructed and a nominal temperature evolution was also mapped.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Observation of asymmetrically imploded core plasmas with a two-dimensional sampling image x-ray streak camera

A shell target with a cone for guiding the heating beam has been proposed for the fast ignition scheme. Implosion of such target is no longer symmetric because of the cone. A fast two-dimensional x-ray imaging technique, two-dimensional (2D) sampling image x-ray streak camera was applied for the first time to observation of the dynamics of implosion and core plasma. X-ray emission image of the plasma was sampled with two-dimensionally distributed image sampling points, streaked with the tube, and the recorded signals were reconstructed as sequential 2D frame images. Shape and movement of the core plasma were clearly observed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Wavelet analysis of fast photometry on Cygnus X-1 with the AstraLux camera

We present sub-second fast photometry for the high mass X-ray binary Cygnus X-1. We try to observe variability due to instabilities in the accretion process at optical wavelengths. The observations were carried out using the high speed AstraLux camera at the Calar Alto 2.2 m telescope, Spain, in November 2006 and August 2007. We report that the Cygnus X-1 system light curve sampled every 30 milli-second did not display strong enough evidence of any periodic component related to the source.

79 ASTRONOMY AND ASTROPHYSICS↗

Electron spectroscopy using two-dimensional electron detection and a camera in a single electron counting mode

A brief description is given of an economical implementation of the read out of a two-dimensional detector in an electron spectrometer by a charge coupled device camera, using a pulse counting mode. Count rates up to 10 kHz can be handled in this way. A comparison with results obtained using a resistive anode detector is given for the case of electron scattering from Xe atoms. Good agreement was obtained between both detection techniques, establishing the validity of the method described here.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Super-resolution with the Help of Active Camera

In a digital optical imaging system, image resolution is constrained by several factors, including focus plane array pitch and optics. Super-resolution approaches aim at overcoming some of these limits by incorporating additional information of the object and/or combining several pictures of the same object, taken with sub-pixel displacements between each other. As shown by some authors, the obtainable zoom factor using the second approach has an upper limit, determined by the signal-to-noise ratio of the image taken. Moreover, as discussed later in this paper, lines at some pitch are indistinguishable, further lowering this limit. Here, an approach to overcome this using active camera and employing images of different relative scales is introduced. The choice of these scales is commented. The results from two experiments, using simulated and real set-up are presented and discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design Considerations Of A Compton Camera For Low Energy Medical Imaging

Development of a Compton camera for low energy medical imaging applications is underway. The ProSPECTus project aims to utilize position sensitive detectors to generate high quality images using electronic collimation. This method has the potential to significantly increase the imaging efficiency compared with mechanically collimated SPECT systems, a highly desirable improvement on clinical systems. Design considerations encompass the geometrical optimisation and evaluation of image quality from the system which is to be built and assessed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗