First Dark Matter Results from the CDMS 5-Tower Run and the path towards {sigma} = 10{sup -46} cm{sup 2} Wimp sensitivity

This paper will report on the recently released results from the Cryogenic Dark Matter Search (CDMS II) experiment. Data from 30 cryogenic particle detectors operated at the Soudan Underground Laboratory between October 2006 and July 2007 was collected. The results from from a blind analysis of 15 Ge detectors corresponding to total exposure of 121.3 kg-d (averaged over the recoil energy range 10-100 keV, and weighted for a weakly interacting massive particle (WIMP) mass of 60 GeV/c{sup 2}) are presented here. With zero observed events an upper limit on WIMP-nucleon spin-independent cross section of 6.6x10{sup -44} cm{sup 2} is obtained from this data set alone. The limit improves to 4.6x10{sup -44} cm{sup 2} when combined with previous CDMS data. The paper will also describe current efforts at designing and building larger mass detectors ({approx}few kg/detector) which will form the basis of a future 1-Ton cryogenic Ge detector experiment.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

PET examination in intracranial tumor diagnosis of a cat

This paper shows the significance of the Positron Emission Tomography (PET) in the veterinary medication through a case study of a cat brain tumor. A castrated male cat with bilateral mydriasis and blindness arrived at the veterinary clinic. After physical, laboratory and neurological investigations other sickness was ruled out and the inkling of the intracranial lesion had come to light. Brain tumor seemed the most likely to cause the illness because other symptoms appeared (for example: anorexia, depression) and they progrediated fast. PET examination, using {sup 18}F-FDG isotope, was performed to confirm the possible causes of the cat's symptoms.

60 APPLIED LIFE SCIENCES↗

The Large-Area Time-Of-Flight (TOF) Upgrade for the STAR Detector

The STAR experiment at RHIC concentrates on the tracking of charged hadrons via ionization in gas- and silicon-based detectors, and the detection of electrons and photons via calorimetry, in a wide and azimuthally complete acceptance that's unique at RHIC. STAR's ability to directly identify the tracked charged hadrons is however limited to low momenta. Approximately half of the charged particles in the event at higher momenta cannot be directly identified, which hampers the physics reach of STAR in a number of key areas. To address this blind spot, STAR is presently constructing a large-area ({approx}50 m{sup 2}) Time-Of-Flight (TOF) system. This system is based on Multi-gap Resistive Plate Chambers (MRPCs). Prototype TOF systems based on this technology were operated in STAR during RHIC Runs 3 through 6, and the first 5 final-system trays were operated in the recent RHIC Run 8. A new 'start detector' for this system has also been constructed and operated in STAR. The performance of these detectors in STAR, and an update on the status of the construction of the full system, is discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Resolution of Ion Mobility Spectra for the Detection of Hazardous Substances in Real Sampling Conditions

This work presents the possibilities offered by a blind source separation method such Multivariate Curve Resolution- Alternating Least Squares (MCR-ALS) in the analysis of Ion Mobility Spectra (IMS). Two security applications are analyzed in this context: the detection of TNT both in synthetic and real samples. Results obtained show the possibilities offered by the direct analysis of the drift time spectra when an appropriate resolution method is used.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Lepton flavour violating slepton decays to test type-I and II seesaw at the LHC

Searches at the LHC of lepton flavour violation (LFV) in slepton decays can indirectly test both type-I and II seesaw mechanisms. Assuming universal flavour-blind boundary conditions, LFV in the neutrino sector is related to LFV in the slepton sector by means of the renormalization group equations. Ratios of LFV slepton decay rates result to be a very effective way to extract the imprint left by the neutrino sector. Some neutrino scenarios within the type-I seesaw mechanism are studied. Moreover, for both type-I and II seesaw mechanisms, a scan over the minimal super-gravity parameter space is performed to estimate how large LFV slepton decay rates can be, while respecting current low-energy constraints.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

MFV and the SUSY CP Problem

The principle of Minimal Flavour Violation (MFV) provides a natural solution to the SUSY flavour problem, but does not solve the SUSY CP problem as it allows for the presence of new CP-violating phases. If the MFV principle is generalized by the assumption of CP conservation in the limit of flavour blindness, the SUSY CP problem can be solved, predicting at the same time interesting CP violating phenomenology.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

High-Energy Observation of GRB 090217 with Fermi

The Fermi observatory is advancing our knowledge of Gamma-Ray Bursts (GRBs) through pioneering observations at high energies, covering more then 7 decades of energy with the two on-board detectors, the Large Area Telescope (LAT) and the Gamma-ray Burst Monitor (GBM). Here we report on the observation of long GRB 090217 which triggered the GBM and as been independently detected by the on-ground blind search LAT algorithm. We present the GBM and LAT observations, including a temporal profile and time-resolved spectral analysis from 8 keV up to approx1 GeV. The time-averaged and time-resolved spectra are well reproduced by a Band model, with no substantial spectral evolution. We compare these observations to the other LAT detections of long bursts, and discuss some theoretical implications on GRB high-energy emission.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Reduction Of Chronic Musculoskeletal Pain With Cranial Laser Reflex Technique (CLRT): A Randomized Controlled Trial Using Pressure Algometry

Cranial Laser Reflex Technique (CLRT) is a novel method involving a brief low level laser stimulation of specific cranial reflex points to reduce musculoskeletal pain. Objective: The objective of the study was to compare the immediate effects of CLRT with a sham treatment on chronic musculoskeletal pain using pressure algometry in a double-blinded randomized controlled trial. Methods: Fifty-seven (57) volunteers with various musculoskeletal pains gave informed consent and were randomly allocated to either the CLRT treatment or sham group. Painful trigger points and/or tender spinal joints were found in each patient. Using a digital algometer, the pain/pressure threshold (PPT) was determined and a pain rating was given using a numerical pain scale from 0-10. CLRT or a sham treatment was performed with a 50 mW, 840 nm laser, for a maximum of 20 seconds to the each cranial reflex. The initial pressure (PPT) was immediately delivered to the same spot, and the pain rated again. Results: There was a statistically significant difference in pain scores between CLRT and sham groups immediately following treatment. Improvement was reported in 95% of the treatment group, with 59% reporting an improvement of 2 points or greater. The average change in pain scores in the treatment group was 2.6 points (p 0.000) versus negligible change (p= 0.4) for the control group. Conclusion: The results show that CLRT is effective at immediately reducing chronic musculoskeletal pain. Further studies are needed with additional outcome measures to.

60 APPLIED LIFE SCIENCES↗

Diamond Photodetectors for X-Ray Absorption Spectroscopy Applications

Synchrotron radiation (SR) is a fundamental tool for X-ray research. In particular, X-ray absorption spectroscopy (XAS) accesses information as electronic properties, local structure or chemical-physical state in condensed-matter studies. Ionization chambers (ICs) are the most widely used XAS detectors for transmission measurements because of their reliability, high linearity and good stability. Recently, solid-state detectors have been considered and Si p-i-n has been applied to high fluxes (10{sup 11} ph/s), where the linearity of ICs is no longer guaranteed. Silicon photodiodes exhibit an extremely linear response in at least 5 decades but show diffraction peaks. Diamond is an ideal substrate to produce radiation-hard, low dark current (<1 pA/cm{sup 2}), visible-blind and fast-response X-ray detectors with a high S/N ratio. Diamond detectors were tested as SR monitor capable to withstand the high photon flux density of the 3{sup rd} generation SR sources. Being the lowest X-ray-absorbing solid-state dielectric material, diamond maximizes the flux through thin self-standing devices with minimal spectral effect down to the soft x-ray range. We will present results of X-ray tests of photoconductors based on different diamond substrates. The results will be compared to standard ICs for XAS applications in terms of spectral quality, noise and linearity in the 4-13 keV energy range.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Spatially distributed scintillator arrays for diagnosing runaway electron transport and energy behavior in tokamaks

We present details of a new bismuth germanate [Bi{sub 4}Ge{sub 3}O{sub 12} (BGO)] scintillator array used to diagnose the transport and energy behavior of runaway electrons (REs) in DIII-D. BGO exhibits important properties for these compact detectors including high light yield which sufficiently excites photodiode detectors (8500 photons/MeV), high density and atomic numbers of constituent materials which maximizes sensitivity, and relative neutron blindness which minimizes complications in data interpretation. The detectors observe primarily hard x-ray radiation emitted in a forward beamed pattern by RE when they strike first wall materials or bulk ions and neutrals in the plasma, although we also address photoneutron signals. The arrangement of the array enables time resolved location of x-ray emission and associated asymmetries which help identify instabilities and confinement properties of RE. By shielding a subset of detectors with different thicknesses of lead, and with interpretative support of the code EGSNRC, we also measure RE energy, although due to the often distributed nature of RE strike points and the forward beamed character of emitted hard x-rays, we restrict interpretation as a lower bound for RE energy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Observations of Langmuir ponderomotive effects using the Solar TErrestrial RElations Observatory spacecraft as a density probe

Langmuir ponderomotive effects are nonlinear effects that enable to couple the electron and ion dynamics in space plasmas. The main difficulty to provide observational evidence of such nonlinear coupling is to simultaneously observe both fluctuations of plasma density and electric field. We have thus developed a new method to measure and to calibrate in situ small scale density fluctuations. Density fluctuations in the solar wind are measured using the observed quasistatic fluctuations of the STEREO spacecraft floating potential in the frequency range, where the spacecraft floating potential is in quasistatic equilibrium between photoionization and electron attachment, whereas the potential of the antenna, of much longer equilibrium time scale, is blind to the density fluctuations. Density fluctuations and Langmuir waves are thus directly and simultaneously measured using a dataset of more than three years of STEREO/WAVES measurements. We present here the first observational evidence for ponderomotive effects in the solar wind that nonlinearly couple density fluctuations to high energy Langmuir waves (({epsilon}{sub 0}E{sup 2})/(nk{sub B}T)>10{sup -4}).

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Lattice Simulations in MOM v.s. Schroedinger Functional Scheme and Triality

The QCD beta function extracted from polarized electron proton scattering data obtained at JLab and the lattice simulation in the MOM scheme suggest that the critical flavor number for the presence of IR fixed point is about three. In analyses of Schroedinger functional scheme, however, critical flavor number for the presence of IR fixed point and the conformality is larger than nine.In the QCD analysis, when quarks are expressed in quaternion basis, the product of quaternions are expressed by octonions and the octonion posesses the triality symmetry. Since the triality has the effect of multiplying the falvor number, it could explain the apparent large critical flavor number in the Schroedinger functinal scheme. In this scheme, larger degrees of freedom in adjusting data of different scales on the boundary are necessary than in the MOM scheme.In weak interaction, there is no clear lepton-flavor violation except in the neutrino oscillation. If the triality is assigned to the lepton flavors(e,{mu} and {tau}) and they are assumed to be exact symmetry, or the electro-magnetic interaction preserves tiality, but the strong interaction is triality blind, there is a possibility of explaining the neutrino oscillation through triality mixing of the matter field.The self energy of gluons, ghost and gauge bosons due to self-dual gauge fields and leptonic decays of B,D and D{sub s} mesons are discussed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Structure and prospects of the simplest SO(10) GUTs

We recapitulate the latest results on the class of the simplest SO(10) grand unified models in which the GUTscale symmetry breaking is triggered by an adjoint Higgs representation. We argue that the minimal survival approximation traditionally used in the GUT-and seesaw-scale estimates tends to be blind to very interesting parts of the parameter space in which some of the intermediate-scale states necessary for non-supersymmetric unification of the SM gauge couplings can be as light as to leave their imprints in the TeV domain. The stringent minimal-survival-based estimates of the B - L scale are shown to be relaxed by as much as four orders of magnitude, thus admitting for a consistent implementation of the standard seesaw mechanism even without excessive fine-tuning implied by the previous studies. The prospects of the minimal renormalizable SO(10) GUT as a potential candidate for a well-calculable theory of proton decay are discussed in brief.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Characterization and modeling of a ZnO nanowire ultraviolet photodetector with graphene transparent contact

We report the demonstration of a ZnO nanowire ultraviolet photodetector with a top transparent electrode made of a few-layered graphene sheet. The nanowires have been synthesized using a low-cost electrodeposition method. The detector is shown to be visible-blind and to present a responsivity larger than 10{sup 4} A/W in the near ultraviolet range thanks to a high photoconductive gain in ZnO nanowires. The device exhibits a peak responsivity at 370 nm wavelength and shows a sub bandgap response down to 415 nm explained by an Urbach tail with a characteristic energy of 83 meV. The temporal response of the detector and the power dependence are discussed. A model of the photoconductive mechanism is proposed showing that the main process responsible for the photoconductive gain is the modulation of the conducting surface due to the variation of the surface depletion layer and not the reduction of recombination efficiency stemming from the electron-hole spatial separation. The gain is predicted to decrease at high incident power due to the flattening of the lateral band bending in agreement with experimental data.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Communication: Permanent dipoles contribute to electric polarization in chiral NMR spectra

Nuclear magnetic resonance spectroscopy is blind to chirality because the spectra of a molecule and its mirror image are identical unless the environment is chiral. However, precessing nuclear magnetic moments in chiral molecules in a strong magnetic field induce an electric polarization through the nuclear magnetic shielding polarizability. This effect is equal and opposite for a molecule and its mirror image but is small and has not yet been observed. It is shown that the permanent electric dipole moment of a chiral molecule is partially oriented through the antisymmetric part of the nuclear magnetic shielding tensor, causing the electric dipole to precess with the nuclear magnetic moment and producing a much larger temperature-dependent electric polarization with better prospects of detection.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A seamless acquisition digital storage oscilloscope with three-dimensional waveform display

In traditional digital storage oscilloscope (DSO), sampled data need to be processed after each acquisition. During data processing, the acquisition is stopped and oscilloscope is blind to the input signal. Thus, this duration is called dead time. With the rapid development of modern electronic systems, the effect of infrequent events becomes significant. To capture these occasional events in shorter time, dead time in traditional DSO that causes the loss of measured signal needs to be reduced or even eliminated. In this paper, a seamless acquisition oscilloscope without dead time is proposed. In this oscilloscope, three-dimensional waveform mapping (TWM) technique, which converts sampled data to displayed waveform, is proposed. With this technique, not only the process speed is improved, but also the probability information of waveform is displayed with different brightness. Thus, a three-dimensional waveform is shown to the user. To reduce processing time further, parallel TWM which processes several sampled points simultaneously, and dual-port random access memory based pipelining technique which can process one sampling point in one clock period are proposed. Furthermore, two DDR3 (Double-Data-Rate Three Synchronous Dynamic Random Access Memory) are used for storing sampled data alternately, thus the acquisition can continue during data processing. Therefore, the dead time of DSO is eliminated. In addition, a double-pulse test method is adopted to test the waveform capturing rate (WCR) of the oscilloscope and a combined pulse test method is employed to evaluate the oscilloscope's capture ability comprehensively. The experiment results show that the WCR of the designed oscilloscope is 6 250 000 wfms/s (waveforms per second), the highest value in all existing oscilloscopes. The testing results also prove that there is no dead time in our oscilloscope, thus realizing the seamless acquisition.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Plasma effect on weld pool surface reconstruction by shape-from-polarization analysis

The polarimetric state of the thermal radiations emitted by the weld metal contains geometric information about the emitting surface. Even though the analysed thermal radiation has a wavelength corresponding to a blind spectral window of the arc plasma, the physical presence of the arc plasma itself interferes with the rays radiated by the weld pool surface before attaining the polarimeter, thus modifying the geometric information transported by the ray. In the present work, the effect of the arc plasma-surrounding zone on the polarimetric state and propagation direction of the radiated ray is analyzed. The interaction with the arc plasma zone induces a drop in ray intensity and a refraction of ray optical path.

36 MATERIALS SCIENCE↗