Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “beam diagnostics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

Spectrometer for shot-to-shot photon energy characterization in the multi-bunch mode of the free electron laser at Hamburg

The setup and first results from commissioning of a fast online photon energy spectrometer for the vacuum ultraviolet free electron laser at Hamburg (FLASH) at DESY are presented. With the use of the latest advances in detector development, the presented spectrometer reaches readout frequencies up to 1 MHz. In this paper, we demonstrate the ability to record online photon energy spectra on a shot-to-shot base in the multi-bunch mode of FLASH. Clearly resolved shifts in the mean wavelength over the pulse train as well as shot-to-shot wavelength fluctuations arising from the statistical nature of the photon generating self-amplified spontaneous emission process have been observed. In addition to an online tool for beam calibration and photon diagnostics, the spectrometer enables the determination and selection of spectral data taken with a transparent experiment up front over the photon energy of every shot. This leads to higher spectral resolutions without the loss of efficiency or photon flux by using single-bunch mode or monochromators.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

HEAVY ION FUSION SCIENCE VIRTUALNATIONAL LABORATORY 2nd QUARTER 2009 MILESTONE REPORT: Perform beam and target experiments with a new induction bunching module, extended FEPS plasma, and improved target diagnostic and positioning equipment on NDCX

This effort contains two main components: The new induction-bunching module is expected to deliver higher fluence in the bunched beam, and the new target positioner will enable a significantly enhanced target physics repetition rate. The velocity ramp that bunches the K{sup +} beam in the neutralized drift compression section is established with a bipolar voltage ramp applied to an acceleration gap. An induction acceleration module creates this voltage waveform. The new bunching module (IBM) specially built for NDCX has approximately twice the capability (volt-seconds) as our original IBM. We reported on the beam line design for the best use of the bunching module in our FY08 Q2 report. Based on simulations and theoretical work, we chose to extend the drift compression section and use the additional volt-seconds to extend the pulse duration and keep the peak voltage swing (and velocity excursions) similar to the present module. Simulations showed that this approach, which extends the drift section, to be advantageous because it limits the chromatic aberrations in the beam spot on target. To this end, colleagues at PPPL have fabricated the meter-long extension to the ferroelectric plasma source and it was installed on the beam line with the new IBM in January 2009. Simulation results suggest a factor of two increase in energy deposition from the bunched beam. In the first WDM target run (August-November 2008) the target handling setup required opening the vacuum system to manually replace the target after each shot (which destroys the target). Because of the requirement for careful alignment of each individual target, the target shot repetition rate was no greater than 1 shot per day. Initial results of this run are reported in our FY08 4th Quarter Milestone Report. Based on the valuable experience gained in the initial run, we have designed and installed an improved target alignment and positioning system with the capability to reposition targets remotely. This capability allows us to significantly increase our shot repetition rate, and to take greater advantage of the pinhole/cone arrangement we have developed to localize the beam at final focus. In addition we have improved the capability of the optical diagnostic systems, and we have installed a new beam current transformer downstream of the target to monitor beam current transmitted through the target during an experiment. These improvements will allow us to better exploit the inherent capability of the NDCX facility for high repetition rate and thus to provide more detailed experimental data to assess WDM physics models of target behavior. This milestone has been met by demonstrating highly compressed beams with the new bunching module, which are neutralized in the longer drift compression section by the new ferro-electric plasma sources. The peak uncompressed beam intensity ({approx}600 kW/cm{sup 2}) is higher than in previous measurements, and the bunched beam current profiles are {approx}2ns. We have also demonstrated a large increase in the experimental data acquisition rate for target heating experiments. In the first test of the new remote-controlled target positioning system, we completed three successful target physics shots in less than two hours. Further improvements are expected.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Beam delivery and final focus systems for multi-TeV advanced linear colliders

The Beam Delivery System (BDS) is a critical component of a high-energy linear collider. It transports the beam from the accelerator and brings it to a focus at the Interaction Point. The BDS system includes diagnostic sections for measuring the beam energy, emittance, and polarization, as well as collimators for machine protection. The length of the BDS increases with collision energy. Higher collision energies also require higher luminosities, and this is a significant constraint on the design for energy-frontier machines. Here, we review BDS designs based on traditional quadrupole magnets and examine the challenges involved in extending these to the Multi-TeV regime consistent with requirements for advanced accelerator concepts.

43 PARTICLE ACCELERATORS↗

NSLS-II X-Ray Diagnostics Development

NSLS-II x-ray diagnostics will provide continuous online data of electron beam dimensions, which will be used to derive electron beam emittance and energy spread. It will also provide information of electron beam tilt for coupling evaluation. X-ray diagnostics will be based on imaging of bending magnet and three-pole wiggler synchrotron radiation sources. Diagnostics from three-pole wiggler source will be used to derive particles energy spread. Beta and dispersion functions will have to be evaluated for emittance and particles energy spread calculations. Due to small vertical source sizes imaging need to be performed in x-ray energy range. X-ray optics with high numerical aperture, such as compound refractive lens, will be used to achieve required spatial resolution. Optical setups with different magnifications in horizontal and vertical directions fill be employed to deal with large aspect ratio of the source. X-ray diagnostics setup will include x-ray imaging optics, monochromatization, x-ray imaging and recording components.

43 PARTICLE ACCELERATORS↗

Nitrogen ion implantation into various materials using 28 GHz electron cyclotron resonance ion source

The installation of the 28 GHz electron cyclotron resonance ion source (ECRIS) ion implantation beamline was recently completed at the Korea Basic Science Institute. The apparatus contains a beam monitoring system and a sample holder for the ion implantation process. The new implantation system can function as a multipurpose tool since it can implant a variety of ions, ranging hydrogen to uranium, into different materials with precise control and with implantation areas as large as 1–10 mm{sup 2}. The implantation chamber was designed to measure the beam properties with a diagnostic system as well as to perform ion implantation with an in situ system including a mass spectrometer. This advanced implantation system can be employed in novel applications, including the production of a variety of new materials such as metals, polymers, and ceramics and the irradiation testing and fabrication of structural and functional materials to be used in future nuclear fusion reactors. In this investigation, the first nitrogen ion implantation experiments were conducted using the new system. The 28 GHz ECRIS implanted low-energy, multi-charged nitrogen ions into copper, zinc, and cobalt substrates, and the ion implantation depth profiles were obtained. SRIM 2013 code was used to calculate the profiles under identical conditions, and the experimental and simulation results are presented and compared in this report. The depths and ranges of the ion distributions in the experimental and simulation results agree closely and demonstrate that the new system will enable the treatment of various substrates for advanced materials research.

36 MATERIALS SCIENCE↗

Electromagnetic Pulses at Short-Pulse Laser Facilities

Electromagnetic Pulse (EMP) is a known issue for short-pulse laser facilities, and will also be an issue for experiments using the advanced radiographic capability (ARC) at the National Ignition Facility (NIF). The ARC diagnostic uses four NIF beams that are compressed to picosecond durations for backlighting ignition capsules and other applications. Consequently, we are working to understand the EMP due to high-energy (MeV) electrons escaping from targets heated by short-pulse lasers. Our approach is to measure EMP in the Titan short-pulse laser at Lawrence Livermore National Laboratory (LLNL) and to employ that data to establish analysis and simulation capabilities. We have installed a wide variety of probes inside and outside the Titan laser chamber. We have high-frequency B-dot and D-dot probes, a photodiode, and fast current-viewing and integrating current transformers. The probe outputs are digitized by 10 and 20 Gsample/s oscilloscopes. The cables and oscilloscopes are well shielded to reduce noise. Our initial measurement campaign has yielded data useful mainly from several hundreds of MHz to several GHz. We currently are supplementing our high-frequency probes with lower-frequency ones to obtain better low-frequency data. In order to establish analysis and simulation capabilities we are modeling the Titan facility using various commercial and LLNL numerical electromagnetics codes. We have simulated EMP generation by having a specified number of electrons leave the target and strike the chamber wall and other components in the chamber. This short impulse of electrons has a correspondingly broad spectrum, exciting high-frequency structure in the resulting EMP. In this paper, we present results of our initial measurement campaign and comparisons between the measurements and simulations.

36 MATERIALS SCIENCE↗

Feasibility of Diagnostics Undulator Studies at ASTA

The Advanced Superconducting Test Accelerator (ASTA) facility is currently under construction at Fermilab. With a 1-ms macropulse composed of up to 3000 micropulses and with beam energies projected from 45 to 800 MeV, the need for non-intercepting diagnostics for beam size, position, energy, and bunch length is clear. In addition to the rf BPMs, optical synchrotron radiation (OSR), and optical diffraction radiation (ODR) techniques already planned, we propose the use of undulator radiation from a dedicated device for diagnostics. with a nominal period of 4-5 cm, a tunable field parameter K, and a length of several meters. The feasibility of extending such techniques in the visible regime at a beam energy of 125 MeV into the UV and VUV regimes with beam energies of 250 and 500 MeV will be presented.

43 PARTICLE ACCELERATORS↗

Target diagnostic control system implementation for the National Ignition Facility (invited)

The extreme physics of targets shocked by NIF's 192-beam laser is observed by a diverse suite of diagnostics. Many diagnostics are being developed by collaborators at other sites, but ad hoc controls could lead to unreliable and costly operations. A diagnostic control system (DCS) framework for both hardware and software facilitates development and eases integration. Each complex diagnostic typically uses an ensemble of electronic instruments attached to sensors, digitizers, cameras, and other devices. In the DCS architecture each instrument is interfaced to a low-cost WINDOWS XP processor and JAVA application. Each instrument is aggregated with others as needed in the supervisory system to form an integrated diagnostic. The JAVA framework provides data management, control services, and operator graphical user interface generation. DCS instruments are reusable by replication with reconfiguration for specific diagnostics in extensible markup language. Advantages include minimal application code, easy testing, and high reliability. Collaborators save costs by assembling diagnostics with existing DCS instruments. This talk discusses target diagnostic instrumentation used on NIF and presents the DCS architecture and framework.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterisation of the PXIE Allison-type emittance scanner

An Allison-type emittance scanner has been designed for PXIE at FNAL with the goal of providing fast and accurate phase space reconstruction. The device has been modified from previous LBNL/SNS designs to operate in both pulsed and DC modes with the addition of water-cooled front slits. Extensive calibration techniques and error analysis allowed confinement of uncertainty to the <5% level (with known caveats). With a 16-bit, 1 MHz electronics scheme the device is able to analyse a pulse with a resolution of 1 μs, allowing for analysis of neutralisation effects. As a result, this paper describes a detailed breakdown of the R&D, as well as post-run analysis techniques.

43 PARTICLE ACCELERATORS↗

Density fluctuation measurements using beam emission spectroscopy on Heliotron J

This paper describes the measurement of the density fluctuation using beam emission spectroscopy in Heliotron J, having the non-symmetrical helical-magnetic-axis configuration. In order to optimize the sightlines, the numerical calculations are carried out to estimate the spatial resolution and the observation location. When a tangential neutral beam is used as diagnostic one, suitable sightlines from the newly installed diagnostic port are selected whose spatial resolution {Delta}{rho} is less than {+-}0.07 over the entire plasma region. Modification of the interference filter and the detection systems enables us to measure the radial profile of the density fluctuation. Each of the three coherent modes due to the fast-ion-driven magnetohydrodynamic instabilities has different radial structure of the density fluctuation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Comparison of beam emission spectroscopy and gas puff imaging edge fluctuation measurements in National Spherical Torus Experiment

In this study, the close physical proximity of the Gas Puff Imaging (GPI) and Beam Emission Spectroscopy (BES) diagnostics on the National Spherical torus Experiment (NSTX) is leveraged to directly compare fluctuation measurements, and to study the local effects of the GPI neutral deuterium puff during H-mode plasmas without large Edge Localized Modes. The GPI and BES views on NSTX provide partially overlapping coverage of the edge and scrape-off layer (SOL) regions above the outboard midplane. The separation in the toroidal direction is 16°, and field lines passing through diagnostic views are separated by ∼20 cm in the direction perpendicular to the magnetic field. Strong cross-correlation is observed, and strong cross-coherence is seen for frequencies between 5 and 15 kHz. Also, probability distribution functions of fluctuations measured ∼3 cm inside the separatrix exhibit only minor deviations from a normal distribution for both diagnostics, and good agreement between correlation length estimates, decorrelation times, and structure velocities is found at the ±40% level. While the two instruments agree closely in many respects, some discrepancies are observed. Most notably, GPI normalized fluctuation levels exceed BES fluctuations by a factor of ∼9. BES mean intensity is found to be sensitive to the GPI neutral gas puff, and BES normalized fluctuation levels for frequencies between 1 and 10 kHz are observed to increase during the GPI puff.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Estimating the performance of lithium beam measurements of current density and electron density in an H-mode pedestal

The lithium beam is an effective diagnostic tool for investigation of stability and particle transport in the pedestal. It was used successfully to measure edge current density on DIII-D, achieving qualitative agreement with neoclassical models. Electron density profiles were also measured. Proposed upgrades will continue these measurements with higher reliability as well as explore edge current measurements using spectroscopy. The optics will be redesigned to optimize throughput and aperture broadening and to replace the photomultiplier tubes with avalanche photodiodes. Here, the new system will yield detailed measurements of the pedestal, complementing existing diagnostics for investigating pedestal stability, edge localized mode cycle, and particle transport through the pedestal.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A THz driven split-ring resonator based ultrafast relativistic electron streak camera

The use of sub-wavelength metal structures to locally enhance high frequency electromagnetic fields, generally known as plasmonics, enables breakthrough opportunities across diverse fields of research such as nonlinear optics, biosensing, photovoltaics and others. Here we study the application of sub-wavelength metallic resonators tuned in the THz frequency range for manipulation and diagnostics of relativistic electron beams. In this work, we report on the use of a double-sided split-ring structure driven by a near single cycle THz field generated by optical rectification to impart a time-dependent angular deviation (streak) on a 4.5 MeV electron beam. Electrons passing through the small gap reveal field enhancement factors larger than 10, in good agreement with finite difference time domain simulations. This work paves the way for further application of high frequency metallic structures in compact particle accelerators such as for THz-based relativistic electron streaking at fs and sub-fs temporal resolution.

79 ASTRONOMY AND ASTROPHYSICS↗

Efficient diode-side-pumped Nd:YVO{sub 4} slab laser in different generation regimes

A diode-side-pumped Nd:YVO{sub 4} slab laser with the grazing-incidence bounce geometry of the cavity is studied experimentally. Upon continuous pumping different lasing regimes are realised, namely, cw, passive and active Q-switching and passive mode-locking. The resonator parameters are optimised to achieve the maximum cw output power ({approx}17 W) and high-quality beam (M{sup 2} {approx} 1.3). (lasers)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Experimental characterization of turbulence properties in negative triangularity DIII-D plasmas

Negative Triangularity (NT) plasmas have demonstrated robustly ELM-free high-performance operation and provide a unique testbed to study how plasma shaping affects turbulent transport. The Beam Emission Spectroscopy (BES) diagnostic provides localized 2D measurements of low-k ($k_{\theta} \rho_s < 1$) density fluctuations. In a sweep of upper triangularity at fixed power, H-mode access is suppressed and an NT-edge is observed. The turbulence amplitude ($\tilde{n}/n$) is shown to decrease by $\sim50\%$ for $\rho<0.9$ in the NT-edge phase as compared to the H-mode phase. Additionally, low-velocity edge modes below 70 kHz are suppressed by triangularity and the dominant mode propagating in the electron diamagnetic direction is seen to broaden in wavenumber space in the NT-edge phase. In a strong NT plasma ($\delta_{avg}\sim-0.5$), low amplitude modes ($\tilde{n}/n <0.5\%$) propagating in the ion-diamagnetic direction with radially-poloidally symmetric eddy structure are identified for $\rho \sim 0.65-0.83$ consistent with Ion Temperature Gradient (ITG) turbulence. Modes consistent with Trapped Electron Mode (TEM) turbulence are observed propagating in the electron-diamagnetic direction for $\rho\gtrsim0.83$ with poloidally extended eddy structure and reduced amplitudes observed at the separatrix. The turbulence properties presented in this paper help validate our understanding of NT turbulence and help explain the improved confinement and unique edge features of NT plasmas.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Simulation of density fluctuations before the L-H transition for Hydrogen and Deuterium plasmas in the DIII-D tokamak using the BOUT++ code

A six-field two-fluid model has been used to simulate density fluctuations. The equilibrium is generated by experimental measurements for both Deuterium (D) and Hydrogen (H) plasmas at the lowest densities of DIII-D low to high confinement (L-H) transition experiments. In linear simulations, the unstable modes are found to be resistive ballooning modes with the most unstable mode number n=30 or $k_\theta\rho_i\sim0.12$ . The ion diamagnetic drift and $E\times B$ convection flow are balanced when the radial electric field (E r ) is calculated from the pressure profile without net flow. The curvature drift plays an important role in this stage. Two poloidally counter propagating modes are found in the nonlinear simulation of the D plasma at electron density $n_e\sim1.5\times10^{19}$ m -3 near the separatrix while a single ion mode is found in the H plasma at the similar lower density, which are consistent with the experimental results measured by the beam emission spectroscopy (BES) diagnostic on the DIII-D tokamak. The frequency of the electron modes and the ion modes are about 40kHz and 10 kHz respectively. The poloidal wave number $k_\theta$ is about 0.2 cm -1 ($k_\theta\rho_i\sim0.05$ ) for both ion and electron modes. The particle flux, ion and electron heat fluxes are~3.5–6 times larger for the H plasma than the D plasma, which makes it harder to achieve H-mode for the same heating power. The change of the atomic mass number A from 2 to 1 using D plasma equilibrium make little difference on the flux. Increase the electric field will suppress the density fluctuation. In conclusion, the electric field scan and ion mass scan results show that the dual-mode results primarily from differences in the profiles rather than the ion mass.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Adaptive autoencoder latent space tuning for more robust machine learning beyond the training set for six-dimensional phase space diagnostics of a time-varying ultrafast electron-diffraction compact accelerator

In this work, we present a general adaptive latent space tuning approach for improving the robustness of machine learning tools with respect to time variation and distribution shift. We demonstrate our approach by developing an encoder-decoder convolutional neural network-based virtual 6D phase space diagnostic of charged particle beams in the HiRES ultrafast electron diffraction (UED) compact particle accelerator with uncertainty quantification. Our method utilizes model-independent adaptive feedback to tune a low dimensional 2D latent space representation of ~1 million dimensional objects which are the 15 unique 2D projections (x, y),...,(z, p z ) of the 6D phase space (x, y, z, p x , p y , p z ) of the charged particle beams. We demonstrate our method with numerical studies of short electron bunches utilizing experimentally measured UED input beam distributions.

43 PARTICLE ACCELERATORS↗