Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “atomization energy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

Concomitant ion effects on isotope ratio measurements with liquid sampling – atmospheric pressure glow discharge ion source Orbitrap mass spectrometry

RATIONALE: The field of highly accurate and precise isotope ratio (IR) analysis has been dominated by inductively coupled plasma and thermal ionization mass spectrometers. While these instruments are considered the gold standard for IR analysis, the International Atomic Energy Agency desires a field deployable instrument capable of accurately and precisely measuring U isotope ratios. METHODS: The proposed system interfaces the liquid sampling – atmospheric pressure glow discharge (LS-APGD) ion source with a high resolution Exactive Orbitrap mass spectrometer. With this experimental setup certified U isotope standards and unknown samples were analyzed. The accuracy and precision of the system were then determined. RESULTS: The LS-APGD /Exactive instrument measures a certified reference material of natural U (235U/238U = 0.007258) as 0.007041 with a relative standard deviation of 0.158% meeting the International Target Values for Uncertainty for the destructive analysis of U. Additionally, when three unknowns measured and compared to the results from an ICP multi collector instrument, there is no statistical difference between the two instruments. CONCLUSIONS: The LS-APGD / Orbitrap system, while still in the preliminary stages of development, offers highly accurate and precise IR analysis that suggest a paradigm shift in the world of IR analysis. Furthermore, the portability of the LS-APGD as an elemental ion source combined with the low overhead and small size of the Orbitrap suggest that the instrumentation is capable of being field deployable. With liquid sampling glow discharge-Orbitrap MS, isotope ratio and precision performance improves with rejection of concomitant ion species.

atmospheric pressure sampling↗

Coupling of an atmospheric pressure microplasma ionization source with an Orbitrap Fusion Lumos Tribrid 1M mass analyzer for ultra-high resolution isotopic analysis of uranium

The coupling of a combined atomic and molecular (CAM) ionization source, the liquid sampling-atmospheric pressure glow discharge (LS-APGD) microplasma to an Orbitrap Fusion Lumos Tribrid 1M mass spectrometer is described as a significant step towards the elimination of isobaric interferences in elemental/isotopic mass spectrometry. The developed setup permits broadband, elemental mass spectra to be easily acquired at a mass resolution (m/Δm) of 500 000. A new ion source housing and integrated control system provide enhanced stability and sensitivity of the microplasma ion source in comparison to the previous designs. Detailed evaluation of the ion sampling parameters provided insight into differences with other Orbitrap platforms leading to a 5-fold increase in resolution in elemental/isotopic analysis. The roles of data acquisition/ion processing parameters were evaluated with regards to the precision and accuracy of 235 U/ 238 U isotope ratios. Significantly, the precision of those measurements improves as a function of pre-set mass resolution up to a value of 1 000 000, where a precision of 0.086% RSD is obtained for uranium concentrations of 100 ng mL− 1 . Analytical response curves (log–log), acquired for the two uranium isotopes at a resolution of 120 000 were linear (R 2 = 0.9969) over more than 5 orders of magnitude, with limits of detection of 1 pg mL −1 for U. Based on 60 μL injection volumes, this represents a mass of 70 fg 235 U. These figures of merit satisfy International Target Values (ITVs) for Measurement Uncertainties in Safeguarding Nuclear Materials set by the International Atomic Energy Agency (IAEA). Ultimately, and totally unique from beam-type instruments, the move to the higher-resolution Orbitrap platform provides all of the benefits of high mass resolution, with no penalties in sensitivity, precision, or dynamic range for uranium analysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Local self-interaction correction method with a simple scaling factor

A recently proposed local self-interaction correction (LSIC) method [Zope et al., J. Chem. Phys., 2019, 151, 214108] when applied to the simplest local density approximation provides a significant improvement over standard Perdew–Zunger SIC (PZSIC) for both equilibrium properties such as total or atomization energies as well as properties involving stretched bond such as barrier heights. The method uses an iso-orbital indicator to identify the single-electron regions. To demonstrate the LSIC method, Zope et al. used the ratio z σ of von Weizsäcker τ W σ and total kinetic energy densities τ σ , (z σ = τ W σ /τ σ ) as a scaling factor to scale the self-interaction correction. The present work further explores the LSIC method using a ratio of orbital and spin densities as a simpler scaling factor in place of the ratio of kinetic energy densities. We compute a wide array of both, equilibrium and non-equilibrium properties using LSIC and orbital scaling methods using this simple scaling factor and compare them with previously reported results. Our study shows that LSIC with the simple scaling factor performs better than PZSIC, with results comparable to those obtained by LSIC( z σ ) for most properties, but has slightly larger errors than LSIC( z σ ). Furthermore, we study the binding energies of small water clusters using both scaling factors. Our results show that LSIC with zσ has limitations in predicting the cluster binding energies of weakly bonded systems due to the inability of z σ to distinguish weakly bonded regions from slowly varying density regions. LSIC when used with the density ratio as a scaling factor, on the other hand, provides a good description of water cluster binding energies, thus highlighting the appropriate choice of the iso-orbital indicator.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Teacher-student training improves the accuracy and efficiency of machine learning interatomic potentials

Machine learning interatomic potentials (MLIPs) are revolutionizing the field of molecular dynamics (MD) simulations. Recent MLIPs have tended towards more complex architectures trained on larger datasets. The resulting increase in computational and memory costs may prohibit the application of these MLIPs to perform large-scale MD simulations. Herein, we present a teacher-student training framework in which the latent knowledge from the teacher (atomic energies) is used to augment the students' training. We show that the light-weight student MLIPs have faster MD speeds at a fraction of the memory footprint compared to the teacher models. Remarkably, the student models can even surpass the accuracy of the teachers, even though both are trained on the same quantum chemistry dataset. Our work highlights a practical method for MLIPs to reduce the resources required for large-scale MD simulations.

36 MATERIALS SCIENCE↗

International network of nuclear structure and decay data evaluators

Compilation, evaluation and dissemination of nuclear data are arduous tasks that rely on contributions from experts in both the basic and applied sciences communities whose efforts are coordinated by the International Atomic Energy Agency (IAEA). The Evaluated Nuclear Structure Data File (ENSDF) includes the most extensive and comprehensive set of nuclear structure and decay data evaluations performed by the international network of Nuclear Structure and Decay Data evaluators (NSDD) under the auspices of the IAEA. In this report we describe the recent NSDD activities supported by the IAEA and provide some future perspectives.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Experimental studies to improve specific actinide decay data.

A Co-ordinated Research Project (CRP) entitled 'Updated Decay Data Library for Actinides' was initiated in 2005 by the International Atomic Energy Agency (IAEA), with the primary aim of improving the quality of recommended decay data for actinides and their decay chains. Participants have attended two Research Coordination Meetings, and agreed on a list of important nuclides and evaluation methodologies to be adopted in work programmes dedicated to the preparation of a new database. Specific measurements were also proposed to address discrepancies between existing data, and some of these experimental studies are described in detail within this paper.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Interpretation of the nonlinear mode excitation in the ITER gyrotron

This study was motivated by an interesting physical effect observed in experiments with a 1 MW, 170 GHz, continuous-wave gyrotron developed at the Japan Atomic Energy Agency for plasma heating and current drive in ITER [see, e.g., Fusion Eng. Des. 55, issues 2-3 (2001)]. In these experiments, the gyrotron switching from a parasitic mode to the operating one was observed with the increase in external magnetic field in the region of hard self-excitation of the operating mode where it cannot be excited from the noise level in the absence of other modes. Below, the theory describing this effect is developed. The switching mechanism caused by merging and disappearance of two (one stable and another unstable) equilibrium states with nonzero amplitudes of both modes is proposed. It is found that the present theory can correctly interpret experimental results qualitatively, but the lack of experimental data does not let the authors carry out some simulations more adequate to experimental conditions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Acceleration of ampere class H{sup -} ion beam by MeV accelerator

The H{sup -} ion accelerator R and D to realize the international thermonuclear experimental reactor neutral beam is ongoing at Japan Atomic Energy Agency (JAEA). The required performance for the prototype MeV accelerator developed at JAEA is 1 MeV, 500 mA (current density of 200 A/m{sup 2}) H{sup -} ion beam at the beamlet divergence angle of less than 7 mrad. Up to 2005, 836 keV, 146 A/m{sup 2} H{sup -} ion beam was successfully accelerated as the highest record of the current density at MeV class energy beams. In the present work, high current negative ion beam acceleration test was performed by increasing the beam extraction apertures from 3x3 (9 apertures) to 3x5 (15 apertures). By fixing the air leak at the source chamber due to backstream ions as well as the improvement of voltage holding capability by a new fiber reinforced plastic insulator ring, the performance of the MeV accelerator was improved. So far, H{sup -} ion beam of 320 mA was successfully accelerated up to 796 keV with the beam divergence angle of 5.5 mrad. The accelerated drain current including the electron reaches close to the power supply limit for the MeV test facility. The heat flux by the backstream ion during the above beam acceleration was estimated to be 360 W/cm{sup 2}. The Cs leakage to the accelerator during the test campaign (Cs total input of 5.0 g) was 0.26 mg (7.0 {mu}g/cm{sup 2}). This is considered to be the allowable level from the viewpoint of voltage holding.

43 PARTICLE ACCELERATORS↗

Experimental studies of zonal flow and field in compact helical system plasma

The experimental studies on zonal flows and turbulence have been carried out in Compact Helical System [K. Matsuoka, S. Kubo, M. Hosokawa et al., in Plasma Physics and Controlled Nuclear Fusion Research, Proc. 12th Int. Conf., Nice, 1988 (International Atomic Energy Agency, Vienna, 1989, Vol. 2, p. 411] using twin heavy ion beam probes. The paper presents the experimental observations of stationary zonal flow, nonlinear couplings between zonal flow and turbulence, and the role of zonal flow in the improved confinement, together with the recent discovery of zonal magnetic field. The presented experimental results strongly support the new paradigm that the plasma transport should be considered as a system of drift wave and zonal flows, and provides the first direct evidence for turbulence dynamo that the structured magnetic field can be really generated by turbulence.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Monitoring the thermal power of nuclear reactors with a prototype cubic meter antineutrino detector

In this paper, we estimate how quickly and how precisely a reactor's operational status and thermal power can be monitored over hour to month time scales, using the antineutrino rate as measured by a cubic meter scale detector. Our results are obtained from a detector we have deployed and operated at 25 m standoff from a reactor core. This prototype can detect a prompt reactor shutdown within 5 h and monitor relative thermal power to within 7 days. Monitoring of short-term power changes in this way may be useful in the context of International Atomic Energy Agency's reactor safeguards regime or other cooperative monitoring regimes.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Joint Experiments on X-ray/Particle Emission from Plasmas Produced by Laser Irradiating Nano Structured Targets

The 1st Joint (Host Laboratory) Experiment on laser plasma involving more than twenty scientists from eight countries has been carried out at the Laser and New Materials Laboratory, Faculty of Science, Cairo University, Egypt. It was co-ordinated by the International Atomic Energy Agency (IAEA) and supported through the IAEA and the ICTP (International Centre for Theoretical Physics, Trieste). The main experimental programme was aimed at characterising the possible enhancement of x-ray and particle emission from plasmas produced by laser incidence on nano-structured targets. Laser beams at 1.064 {mu}m of 250 mJ and 532 nm of 165 mJ focused at the target surface using a nanosecond laser type Quantel were used in the present study. In the present experiments nano-copper structures evaporated onto copper bulk disks and nano-gold structures evaporated onto gold ones were used. The thickness of the nano-materials on their bulk material was 1 {mu}m. An ion collector and x-ray semiconductor diode were used to study the ion and x-ray emission, respectively. Both were positioned at the same port at 90 deg. with respect to the target surface and at 90 cm from the surface in the case of the ion collector and 55 cm in the case of the x-ray detector. These experiments were performed at vacuum pressures of (5--8)x10{sup -6} mbar. Comparison of both studies in the case of nano structured targets and bulk targets were performed at different laser fluencies (1x10{sup 9}-1x10{sup 12} W/cm{sup 2}) on the target. A 20% increase of the X-ray emission for nano gold with respect to bulk gold was observed, however, the x-ray emission in the of nano copper and copper was the same.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Core Calculation of 1 MWatt PUSPATI TRIGA Reactor (RTP) using Monte Carlo MVP Code System

The Monte Carlo MVP code system was adopted for the Reaktor TRIGA PUSAPTI (RTP) core calculation. The code was developed by a group of researcher of Japan Atomic Energy Agency (JAEA) first in 1994. MVP is a general multi-purpose Monte Carlo code for neutron and photon transport calculation and able to estimate an accurate simulation problems. The code calculation is based on the continuous energy method. This code is capable of adopting an accurate physics model, geometry description and variance reduction technique faster than conventional method as compared to the conventional scalar method. This code could achieve higher computational speed by several factors on the vector super-computer. In this calculation, RTP core was modeled as close as possible to the real core and results of keff flux, fission densities and others were obtained.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Photon Science Research at APRC of JAEA

Overviewed is research on photon science and technology at the Advanced Photon Research Center (APRC) of the Japan Atomic Energy Agency (JAEA), where development of ultra-fast, high intensity lasers and their applications are being promoted. The importance of combined applications of laser, accelerators, and synchrotron radiation is emphasized.

43 PARTICLE ACCELERATORS↗

Proficiency Testing as a tool to monitor consistency of measurements in the IAEA/WHO Network of Secondary Standards Dosimetry Laboratories

The International Atomic Energy Agency (IAEA) and the World Health Organization (WHO) established a Network of Secondary Standards Dosimetry Laboratories (IAEA/WHO SSDL Network) in 1976. Through SSDLs designated by Member States, the Network provides a direct link of national dosimetry standards to the international measurement system of standards traceable to the Bureau International des Poids et Mesures (BIPM). Within this structure and through the proper calibration of field instruments, the SSDLs disseminate S.I. quantities and units.To ensure that the services provided by SSDL members to end-users follow internationally accepted standards, the IAEA has set up two different comparison programmes. One programme relies on the IAEA/WHO postal TLD service and the other uses comparisons of calibrated ionization chambers to help the SSDLs verify the integrity of their national standards and the procedures used for the transfer of the standards to the end-users. The IAEA comparisons include {sup 60}Co air kerma (N{sub K}) and absorbed dose to water (N{sub D,W}) coefficients. The results of the comparisons are confidential and are communicated only to the participants. This is to encourage participation of the laboratories and their full cooperation in the reconciliation of any discrepancy.This work describes the results of the IAEA programme comparing calibration coefficients for radiotherapy dosimetry, using ionization chambers. In this programme, ionization chambers that belong to the SSDLs are calibrated sequentially at the SSDL, at the IAEA, and again at the SSDL. As part of its own quality assurance programme, the IAEA has participated in several regional comparisons organized by Regional Metrology Organizations.The results of the IAEA comparison programme show that the majority of SSDLs are capable of providing calibrations that fall inside the acceptance level of 1.5% compared to the IAEA.

61 RADIATION PROTECTION AND DOSIMETRY↗

Pediatric Computed Tomography. Radiation Dose in Abdominal Studies

Computed tomography is one of the most popular medical imaging modalities used in the last years. However, because is one of the techniques that delivered a considerable radiation dose, precautions should be taken into account. Pediatric patients are more radiosensitive than adults, and the probability that no desirable biological effects can occur is greater. To this, also it adds the probability that they will need more radiological studies in the future. The work consisted in determining the received dose by the pediatric patients undergoing abdominal studies in a multislice computed tomograph, according to the dosimetric quantities established by a Code of Practice published by the International Atomic Energy Agency; using a ionization chamber and a phantom that simulates the abdomen of a pediatric patient. The weighted air kerma index (C{sub w}) was 14.3{+-}0.4 mGy, this value is lower than the published by the American College of Radiology, 25 mGy. The multiple scan average dose (MSAD), which is a quantity established by the NOM-229-SSA1-2002 was determined, finding a value of 14.2{+-}0.1 mGy, it is also below the value established, 25 mGy for an adult study.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Resistive edge mode instability in stellarator and tokamak geometries

Geometrical effects on linear stability of electrostatic resistive edge modes are investigated in the three-dimensional Wendelstein 7-X stellarator [G. Grieger et al., Plasma Physics and Controlled Nuclear Fusion Research 1990 (International Atomic Energy Agency, Vienna, 1991), Vol. 3, p. 525] and the International Thermonuclear Experimental Reactor [Progress in the ITER Physics Basis, Nucl. Fusion 7, S1, S285 (2007)]-like equilibria. An advanced fluid model is used for the ions together with the reduced Braghinskii equations for the electrons. Using the ballooning mode representation, the drift wave problem is set as an eigenvalue equation along a field line and is solved numerically using a standard shooting technique. A significantly larger magnetic shear and a less unfavorable normal curvature in the tokamak equilibrium are found to give a stronger finite-Larmor radius stabilization and a more narrow mode spectrum than in the stellarator. The effect of negative global magnetic shear in the tokamak is found to be stabilizing. The growth rate on a tokamak magnetic flux surface is found to be comparable to that on a stellarator surface with the same global magnetic shear but the eigenfunction in the tokamak is broader than in the stellarator due to the presence of large negative local magnetic shear (LMS) on the tokamak surface. A large absolute value of the LMS in a region of unfavorable normal curvature is found to be stabilizing in the stellarator, while in the tokamak case, negative LMS is found to be stabilizing and positive LMS destabilizing.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Quantitative Evaluation of Ion-implanted Arsenic in Silicon by Instrumental Neutron Activation Analysis

Certified reference materials (CRMs) of shallow arsenic implants in silicon are now under development at the National Metrology Institute of Japan (NMIJ). The amount of ion-implanted arsenic atoms is quantified by Instrumental Neutron Activation Analysis (INAA) using research reactor JRR-3 in Japan Atomic Energy Agency (JAEA). It is found that this method can evaluate arsenic amounts of 10{sup 15} atoms/cm{sup 2} with small uncertainties, and is adaptable to shallower dopants. The estimated uncertainties can satisfy the industrial demands for reference materials to calibrate the implanted dose of arsenic at shallow junctions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Observation of the isotopic evolution of pressurized water reactor fuel using an antineutrino detector

By operating an antineutrino detector of simple design during several fuel cycles, we observed long term changes in antineutrino flux that result from the isotopic evolution of a commercial pressurized water reactor. Measurements made with simple antineutrino detectors of this kind offer an alternative means for verifying fissile inventories at reactors, as part of International Atomic Energy Agency and other reactor safeguards regimes.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗