Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Waste Transfer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

Remote monitoring of Alpha Gamma hot cell facility by ARG-US RFID system - 15177

Argonne National Laboratory (Argonne) has developed a monitoring and tracking system for nuclear materials based on radio frequency identification (RFID) technology. The system, called ARG-US ('Watchful Guardian'), has been in fielding testing and applications at selected U.S. Department of Energy (DOE) sites since 2010. ARG-US utilizes battery-powered tags to remotely and continuously monitor the environmental parameters, e.g., radiation levels, of the tagged items such as containers of radioactive materials. To demonstrate that the system can monitor nuclear and radiological facilities as well, a compact system was installed in the Alpha Gamma Hot Cell Facility (AGHCF) at Argonne in 2013. AGHCF is a Hazard Category 2 non-reactor nuclear facility that is being decommissioned. It is also being used to support de-inventory of other facilities on the Argonne site. As such, large quantities of radioactive materials and wastes are being discharged from the hot cell, loaded into transport containers, and shipped away. The deployed ARG-US system monitors worker areas, material transfer areas, cell exhaust HEPA filters, and?on a rover/robot?in-cell locations of AGHCF. Thus far, the system is performing as designed and yielding results that can be corroborated by existing surveillance means. The in-cell unit is particularly valuable, as it yields information that would otherwise be hard to obtain. In time, the benefits of automated monitoring 24/7 by ARG-US should become apparent and may lead to a fuller system with more distributed tags in the hot cell areas until the facility is fully decommissioned. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Next Generation Solvent (NGS): Development for Caustic-Side Solvent Extraction of Cesium

This report summarizes the FY 2010 and 2011 accomplishments at Oak Ridge National Laboratory (ORNL) in developing the Next Generation Caustic-Side Solvent Extraction (NG-CSSX) process, referred to commonly as the Next Generation Solvent (NGS), under funding from the U.S. Department of Energy, Office of Environmental Management (DOE-EM), Office of Technology Innovation and Development. The primary product of this effort is a process solvent and preliminary flowsheet capable of meeting a target decontamination factor (DF) of 40,000 for worst-case Savannah River Site (SRS) waste with a concentration factor of 15 or higher in the 18-stage equipment configuration of the SRS Modular Caustic-Side Solvent Extraction Unit (MCU). In addition, the NG-CSSX process may be readily adapted for use in the SRS Salt Waste Processing Facility (SWPF) or in supplemental tank-waste treatment at Hanford upon appropriate solvent or flowsheet modifications. Efforts in FY 2010 focused on developing a solvent composition and process flowsheet for MCU implementation. In FY 2011 accomplishments at ORNL involved a wide array of chemical-development activities and testing up through single-stage hydraulic and mass-transfer tests in 5-cm centrifugal contactors. Under subcontract from ORNL, Argonne National Laboratory (ANL) designed a preliminary flowsheet using ORNL cesium distribution data, and Tennessee Technological University confirmed a chemical model for cesium distribution ratios (DCs) as a function of feed composition. Interlaboratory efforts were coordinated with complementary engineering tests carried out (and reported separately) by personnel at Savannah River National Laboratory (SRNL) and Savannah River Remediation (SRR) with helpful advice by Parsons Engineering and General Atomics on aspects of possible SWPF implementation.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Preparation, Characterization and Dye Adsorption/Reuse of Chitosan-Vanadate Films

Chitosan used on dyes adsorption when in film form shows limitations due to its low regeneration capacity. In this work, chitosan films were modified using vanadium ions to improve its regeneration capacity on the dye adsorption. Films were characterized and analyzed by FT-IR, XRD and DSC. Adsorption assays were performed using chitosan-vanadate films (CVF) to remove the Reactive Black 5 dye in aqueous solution. The adsorption was favored by the pH decrease from 8.0 to 4.0. The equilibrium data were best fitted by Langmuir model, with q{sub m} of 522 mg g{sup −1} at 298 K. The negative value of ΔH{sup 0} (−9.91 kJ mol{sup −1}) showed an exothermic operation and the value of ΔS{sup 0} was positive (0.0705 kJ mol{sup −1} K{sup −1}), suggesting an increase in randomness at the solid/solution interface. The kinetics was represented by pseudo-first order model and around 80 min occurred a reduction in the adsorption rates, due to the mass transfer mechanism. The most appropriate eluent to remove the RB5 from CVF was NH{sub 4}OH 0.01 kg mol L{sup −1}. The CVF used to the dye adsorption were regenerated and reutilized five times, and the adsorption capacity was around 80% of the initial value after the last cycle.

36 MATERIALS SCIENCE↗

In-situ preparation of Fe{sub 2}O{sub 3} hierarchical arrays on stainless steel substrate for high efficient catalysis

Hierarchical array catalysts with micro/nano structures on substrates not only possess high reactivity from large surface area and suitable interface, but intensify mass transfer through shortening the diffusion paths of both reactants and products for high catalytic efficiency. Herein, we first demonstrate fabrication of Fe{sub 2}O{sub 3} hierarchical arrays grown on stainless-steel substrates via in-situ hydrothermal chemical oxidation followed by heat treatment in N{sub 2} atmosphere. As a Fenton-like catalyst, Fe{sub 2}O{sub 3} hierarchical arrays exhibit excellent catalytic activity and life cycle performance for methylene blue (MB) dye degradation in aqueous solution in the presence of H{sub 2}O{sub 2}. The Fe{sub 2}O{sub 3} catalyst with unique hierarchical structures and efficient transport channels, effectively activates H{sub 2}O{sub 2} to generate large quantity of • OH radicals and highly promotes reaction kinetics between MB and • OH radicals. Immobilization of hierarchical array catalysts on stainless-steel can prevent particles agglomeration, facilitate the recovery and reuse of the catalysts, which is expected promising applications in wastewater remediation. - Graphical abstract: The in-situ synthesis of Fe{sub 2}O{sub 3} hierarchical arrays on stainless-steel substrates was reported for the first time, which exhibit excellent catalytic activity performance for methylene blue (MB) dye degradation in aqueous solution in the presence of H{sub 2}O{sub 2}. - Highlights: • Fe{sub 2}O{sub 3} hierarchical arrays was prepared by in-situ hydrothermal chemical oxidation. • F{sup −} ions play an important role in the formation of the Fe{sub 2}O{sub 3} hierarchical arrays. • Fe{sub 2}O{sub 3} hierarchical arrays show high catalytic activity to methylene blue degradation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Advanced absorber heat integration via heat exchange packings

A rate-based model of an absorption column was developed and used to analyze several intercooling strategies utilizing “heat exchange packings.” These packings are capable of removing heat from the column and transferring it to a cooling fluid within the packing. For absorption of CO 2 into aqueous monoethanolamine under industrial conditions, intercooling via heat exchange packings placed along 10–20% of the column could reduce the column height by ~15%. The height of these columns was close to the minimum theoretical value, calculated by numerically optimizing the temperature profile. Effective intercooling could also be achieved by using the cool, rich solvent as the cooling fluid. This reduces the cooling load and facilitates recovery of waste heat. Heat exchange packings could also be used to redistribute heat within the column, reducing the column height with no net cooling load. However, this approach requires larger heat transfer coefficients than have been experimentally observed.

20 FOSSIL-FUELED POWER PLANTS↗

Elucidating Syntrophic Butyrate-Degrading Populations in Anaerobic Digesters Using Stable-Isotope-Informed Genome-Resolved Metagenomics

Linking the genomic content of uncultivated microbes to their metabolic functions remains a critical challenge in microbial ecology. Resolving this challenge has implications for improving our management of key microbial interactions in biotechnologies such as anaerobic digestion, which relies on slow-growing syntrophic and methanogenic communities to produce renewable methane from organic waste. In this study, we combined DNA stable-isotope probing (SIP) with genome-centric metagenomics to recover the genomes of populations enriched in 13 C after growing on [ 13 C]butyrate. Differential abundance analysis of recovered genomic bins across the SIP metagenomes identified two metagenome-assembled genomes (MAGs) that were significantly enriched in heavy [ 13 C]DNA. Phylogenomic analysis assigned one MAG to the genus Syntrophomonas and the other MAG to the genus Methanothrix. Metabolic reconstruction of the annotated genomes showed that the Syntrophomonas genome encoded all the enzymes for beta-oxidizing butyrate, as well as several mechanisms for interspecies electron transfer via electron transfer flavoproteins, hydrogenases, and formate dehydrogenases. The Syntrophomonas genome shared low average nucleotide identity (<95%) with any cultured representative species, indicating that it is a novel species that plays a significant role in syntrophic butyrate degradation within anaerobic digesters. The Methanothrix genome contained the complete pathway for acetoclastic methanogenesis, indicating that it was enriched in 13 C from syntrophic acetate transfer. This study demonstrates the potential of stable-isotope-informed genome-resolved metagenomics to identify in situ interspecies metabolic cooperation within syntrophic consortia important to anaerobic waste treatment as well as global carbon cycling.

59 BASIC BIOLOGICAL SCIENCES↗

TANK 18 AND 19-F TIER 1A EQUIPMENT FILL MOCK UP TEST SUMMARY

The United States Department of Energy (US DOE) has determined that Tanks 18-F and 19-F have met the F-Tank Farm (FTF) General Closure Plan Requirements and are ready to be permanently closed. The high-level waste (HLW) tanks have been isolated from FTF facilities. To complete operational closure they will be filled with grout for the purpose of: (1) physically stabilizing the tanks, (2) limiting/eliminating vertical pathways to residual waste, (3) discouraging future intrusion, and (4) providing an alkaline, chemical reducing environment within the closure boundary to control speciation and solubility of select radionuclides. Bulk waste removal and heel removal equipment remain in Tanks 18-F and 19-F. This equipment includes the Advance Design Mixer Pump (ADMP), transfer pumps, transfer jets, standard slurry mixer pumps, equipment-support masts, sampling masts, dip tube assemblies and robotic crawlers. The present Tank 18 and 19-F closure strategy is to grout the equipment in place and eliminate vertical pathways by filling voids in the equipment to vertical fast pathways and water infiltration. The mock-up tests described in this report were intended to address placement issues identified for grouting the equipment that will be left in Tank 18-F and Tank 19-F. The Tank 18-F and 19-F closure strategy document states that one of the Performance Assessment (PA) requirements for a closed tank is that equipment remaining in the tank be filled to the extent practical and that vertical flow paths 1 inch and larger be grouted. The specific objectives of the Tier 1A equipment grout mock-up testing include: (1) Identifying the most limiting equipment configurations with respect to internal void space filling; (2) Specifying and constructing initial test geometries and forms that represent scaled boundary conditions; (3) Identifying a target grout rheology for evaluation in the scaled mock-up configurations; (4) Scaling-up production of a grout mix with the target rheology (16 second flow cone value) from 0.25 cubic feet to 4.3 cubic feet. (Ten 0.43 cubic batches were produced because full-scale equipment was not available for the Tier 1A test.); (5) Demonstrating continuous gravity filling of the ADMP mock up test form; (6) Demonstrating continuous gravity filling of 1 inch and 2 inch schedule 40 pipe; and (7) Demonstrating filling of 1 inch and 2 inch schedule 40 pipe from the bottom up by discharging through a tube inserted into the pipes. The Tier 1A mock-up test focused on the ADMP and pipes at least one inch in diameter. The ADMP which is located in center riser of Tank 18-F is a concern because the column for this long-shaft (55 ft) pump is unique and modification to the pump prior to placing it in service limited the flow path options for filling by creating a single flow path for filling and venting the ADMP support column. The large size, vertical orientation, and complicated flow path in the ADMP warrants a detailed description of this piece of ancillary equipment.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Design and Characterization of High Thermal Conductivity Pipes from Roll-to- Roll Processed Hybrid Copper-Polymer Strips for Waste Heat Recovery

Metal based heat exchangers targeting low temperature (<150°C) waste heat recovery (WHR) face high maintenance and material costs [1] that result in long payback periods (>1 year). Low-cost polymer pipes suffer from poor thermal conductivity (~0.2 W/m.K), and thus a low overall heat transfer coefficient. Previous reports demonstrated thermal conductivity enhancement in polymers through systematic molecular alignment [2, 3, 4], or by metal micro-particle inclusions [5]. However, these approaches suffer from scalability issues for WHR heat exchangers in terms of cost [1, 3], and thermomechanical considerations [6, 7]. In this work, we propose hybrid metal-polymer strips that are strategically designed to enhance thermal conductivity by cladding copper around polymer strips. The polymer strips with copper-clad edges are wound helically to form the pipes for a heat exchanger. Through numerical simulations, we optimize the copper-polymer strip layouts to achieve high wall thermal conductivity (k > 1 W/m.K) and also have low volume fraction of copper (<70%) for the composite pipes. In copper-polymer composite heat exchangers, the bottlenecks for heat transfer are the thermal interfacial resistances of copper-copper and copper-polymer joints. We experimentally measured interfacial resistances to be ~1x10 -5 K.m 2 /W and ~4x10 -5 K.m 2 /W for copper-copper and copper-polymer joints, respectively. Using the measured interfacial resistances, we further optimized the design of the hybrid pipes to find high thermal conductivity (> 1 W/m.K) designs. We predict up to ~20 % enhancement in overall heat transfer relative to an all polymer (k = 0.2 W/m.K) heat exchanger system. Using a cohesive zone modelling (CZM) for predicting delamination at the weld joints, we find that our hybrid pipes can have operating internal pressures > 200 psi. The optimized designs of hybrid metal-polymer pipes provide a scalable and cost- effective means for harvesting waste heat from low temperature sources. Thekdi, A., and Nimbalkar, S. Oak Ridge National Lab (2014). Shen, Sheng, et al. Nature nanotechnology 5.4 (2010). Xu, Yanfei, et al. Science advances 4.3 (2018). Smith et al. ACS nano, 9(2), (2015). Sofian, N.M., et al., Journal of Thermoplastic Composite Materials (2001). Aymonier et al. Chemistry of Materials, 15(25), (2003). Tavman, I.H., Journal of Applied Polymer Science, 62(12), (1996).

C Rajagopal, Manjunath↗

Computational Fluid Dynamics Modeling of Bubbling in a Viscous Fluid for Validation of Waste Glass Melter Modeling

At the Hanford site, radioactive waste stored in underground tanks is slated for vitrification for final disposal. A comprehensive knowledge of the glass batch melting process will be useful in optimizing the process, which could potentially reduce the cost and duration of this multi-billion dollar cleanup effort. We are developing a high-fidelity heat transfer model of a Joule-heated ceramic lined melter to improve the understanding of the complex, inter-related processes occurring with the melter. The glass conversion rates in the cold cap layer are dependent on promoting efficient heat transfer. In practice, heat transfer is augmented by inserting air bubblers into the molten glass. However, the computational simulations must be validated to provide confidence in the solutions. As part of a larger validation procedure, it is beneficial to split the physics of the melter into smaller systems to validate individually. The substitution of molten glass for a simulant liquid with similar density and viscosity at room temperature provides a way to study mixing through bubbling as an isolated effect without considering the heat transfer dynamics. The simulation results are compared to experimental data obtained by the Vitreous State Laboratory at the Catholic University of America using bubblers placed within a large acrylic tank that is similar in scale to a pilot glass waste melter. Comparisons are made for surface area of the rising air bubbles between experiments and CFD simulations for a variety of air flow rates and bubble injection depths. Also, computed bubble rise velocity is compared to a well-accepted expression for bubble terminal velocity.

bubbling↗

Limitations for heavy metal release during thermo-chemical treatment of sewage sludge ash

Phosphate recycling from sewage sludge can be achieved by heavy metal removal from sewage sludge ash (SSA) producing a fertilizer product: mixing SSA with chloride and treating this mixture (eventually after granulation) in a rotary kiln at 1000 {+-} 100 deg. C leads to the formation of volatile heavy metal compounds that evaporate and to P-phases with high bio-availability. Due to economical and ecological reasons, it is necessary to reduce the energy consumption of this technology. Generally, fluidized bed reactors are characterized by high heat and mass transfer and thus promise the saving of energy. Therefore, a rotary reactor and a fluidized bed reactor (both laboratory-scale and operated in batch mode) are used for the treatment of granulates containing SSA and CaCl{sub 2}. Treatment temperature, residence time and - in case of the fluidized bed reactor - superficial velocity are varied between 800 and 900 deg. C, 10 and 30 min and 3.4 and 4.6 m s{sup -1}. Cd and Pb can be removed well (>95 %) in all experiments. Cu removal ranges from 25% to 84%, for Zn 75-90% are realized. The amount of heavy metals removed increases with increasing temperature and residence time which is most pronounced for Cu. In the pellet, three major reactions occur: formation of HCl and Cl{sub 2} from CaCl{sub 2}; diffusion and reaction of these gases with heavy metal compounds; side reactions from heavy metal compounds with matrix material. Although, heat and mass transfer are higher in the fluidized bed reactor, Pb and Zn removal is slightly better in the rotary reactor. This is due the accelerated migration of formed HCl and Cl{sub 2} out of the pellets into the reactor atmosphere. Cu is apparently limited by the diffusion of its chloride thus the removal is higher in the fluidized bed unit.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Heat Transfer in a Molten Natural Uranium Nuclear Reactor With Thermal Storage

Previous papers describe a method for controlling a thermal nuclear reactor by moderator displacement between the reactor core and the reflector. The low neutron loss and high control range of this method enable a design for a molten natural uranium fueled and cooled heavy water moderated reactor. The design is geometrically similar to CANDU (Canadian Deuterium Uranium) reactors but with fewer, larger, vertically oriented fuel tubes. The large fuel tubes have a mixed spectrum which is largely thermal at the periphery of the tubes with a very hard spectrum in the large central region of the tube. This configuration provides a fast fission rate of around 15% (mostly of U-238) and an initial conversion ratio of around 1.15. It is a hypothetical reactor because it is unclear what materials could actually be used to fabricate the fuel tubes and other primary coolant plumbing. The molten uranium serves both as the fuel and the primary coolant and as such is continuously circulated through the fuel tubes in the reactor core, the primary heat exchange, and back to the the reactor core. This means that at any point in time all the fuel has the same isotopic configuration no matter where it is in the reactor or heat exchanger. Over time the isotopic configuration changes, but it changes uniformly for all the fuel. Uranium melts at 1135 deg. C, so a proposed temperature range for the circulating molten uranium is 1200 deg. C at the exit of the heat exchanger and entry to the core fuel tubes and 1400 deg. C at the exit from the core fuel tubes and the entry into the heat exchanger. The advantages of this design include: 1. Reduced nuclear proliferation concern because of natural uranium fuel. 2. High conversion ratio and large fuel mass provides 30 to 100 year fuel life. 3. No heavy metal waste because fissile content increases over the fuel life. 4. High output temperatures are suitable for high efficiency turbine generators. This paper discusses the heat transfer in the molten natural uranium fueled reactor described above and in the cited paper in the simple case and when the reactor is combined with a thermal storage unit which is composed of ordinary salt (NaCl). The proposed molten uranium fueled and cooled nuclear reactor works particularly well when coupled with a molten salt heat storage unit, a process heat user, and high Efficiency air-Brayton cycle turbine generators which can also add energy to the hot air output of the tin/air heat exchanges by burning some natural gas or hydrogen. The combination can provide highly variable electrical output to the grid to accommodate large daily and seasonal mismatches between electrical demand and supply from variable sources such as wind and solar. Future work includes modeling of the temperatures throughout the molten salt heat storage unit under varying charge and discharge cycles.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

300 Area Integrated Field-Scale Subsurface Research Challenge (IFRC) Field Site Management Plan

Pacific Northwest National Laboratory (PNNL) has established the 300 Area Integrated Field-Scale Subsurface Research Challenge (300 Area IFRC) on the Hanford Site in southeastern Washington State for the U.S. Department of Energy’s (DOE) Office of Biological and Environmental Research (BER) within the Office of Science. The project is funded by the Environmental Remediation Sciences Division (ERSD). The purpose of the project is to conduct research at the 300 IFRC to investigate multi-scale mass transfer processes associated with a subsurface uranium plume impacting both the vadose zone and groundwater. The management approach for the 300 Area IFRC requires that a Field Site Management Plan be developed. This is an update of the plan to reflect the installation of the well network and other changes.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of the Sludge Batch 7b (Macrobatch 9) DWPF Pour Stream Glass Sample

The Defense Waste Processing Facility (DWPF) began processing Sludge Batch 7b (SB7b), also referred to as Macrobatch 9 (MB9), in January 2012. SB7b is a blend of the heel of Tank 40 from Sludge Batch 7a (SB7a) and the SB7b material that was transferred to Tank 40 from Tank 51. SB7b was processed using Frit 418.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

10 years and 20,000 sources: the offsite source recovery project

The Global Threat Reduction Initiative's (GTRI) Offsite Source Recovery Project (OSRP) has been recovering excess and unwanted sealed sources for ten years. In January 2009, GTRI announced that the project had recovered 20,000 sealed radioactive sources. This project grew out of early efforts at Los Alamos National Laboratory (LANL) to recover and disposition excess Plutonium-239 (Pu-239) sealed sources that were distributed in the 1960s and 1970s under the Atoms for Peace Program. Sealed source recovery was initially considered a waste management activity, as evidenced by its initial organization under the Department of Energy's (DOE's) Environmental Management (EM) program. After the terrorist attacks of 2001, however, the interagency community began to recognize the threat posed by excess and unwanted radiological material, particularly those that could not be disposed at the end of their useful life. After being transferred to the National Nuclear Security Administration (NNSA) to be part of GTRI, OSRP's mission was expanded to include not only material that would be classified as Greater-than-Class-C (GTCC) when it became waste, but also any other materials that might be a 'national security consideration.' This paper discusses OSRP's history, recovery operations, expansion to accept high-activity beta-gamma-emitting sealed sources and devices and foreign-possessed sources, and more recent efforts such as cooperative projects with the Council on Radiation Control Program Directors (CRCPD) and involvement in GTRI's Search and Secure project. Current challenges and future work will also be discussed.

99 GENERAL AND MISCELLANEOUS↗

Pretreated Waste and Melter Feed Composition Variability Testing Using HLW Simulants

This report documents the results of the testing that was performed to fulfill the High Level Waste (HLW) pretreated waste and melter feed product qualification requirements for chemical composition and product loading as described in the Immobilized High Level Waste (IHLW) Wasteform Compliance Plan and the Hanford Tank Waste Treatment and Immobilization Plant (WTP) Contract. Meeting the product quality specifications relies on controlling the melter feed preparation process and the resulting IHLW glass composition. In part, this control depends on the ability of the Melter Feed Preparation Vessel (MFPV) system to homogenize pretreated waste and the melter feed after addition of the glass forming chemicals (GFCs), provide representative sampling of the vessel contents, measure the level over the vessel operating range, and uniformly transfer the vessel contents. A series of tests were conducted on a single scaled down tank, 8 feet in diameter, which was used to represent the WTP HLW MFPV. Prototypic equipment (such as radar level detectors, transfer pumps, agitators, and density probes) was installed in geometrically similar positions to those of the WTP tanks. Other equipment, which is not fully prototypic, was also installed in the tank to fully represent the WTP tank equipment arrangement. In addition, a prototypic autosampler and a hydraulically similar transfer line were installed to represent the WTP tank sampling systems. Testing was performed using simulants that represent the high and low bounds of rheology for the pretreated HLW prior to GFC addition and the HLW melter feed after GFC addition.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

SISGR: Physical chemistry of reaction dynamics in ionic liquids

This document is the final technical report for the five-institution project titled, “SISGR: Physical chemistry of reaction dynamics in ionic liquids”. The project included the groups of Edward Castner, Jr. at Rutgers, Mark Maroncelli at Penn State, Claudio Margulis at Univ. of Iowa, David Blank at Univ. of Minnesota, and James Wishart at Brookhaven National Laboratory. The project spanned several funding periods between 2009 and 2017, with a no-cost extension at Rutgers continuing until 3/14/2018. The scientific research carried out included an array of experimental and theoretical investigations into the properties and chemical reactivity of room-temperature ionic liquids (ILs). Such ILs are of broad importance for energy science and technology applications, including their use in advanced batteries, supercapacitors and fuel cells; processing of biomass to liquid fuels; and for solubilizing and separating high-level radionuclides from nuclear waste products. Specific examples include the study of the transport and structural properties of the liquids, studies of photo-induced electron-transfer reactions, and characterization of solvated electrons in the ILs.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Testing and Versatility of the SAVY 4000 Nuclear Material Container - 15634

The SAVY 4000 container was designed by Nuclear Filter Technology, Inc. to meet DOE M441.1-1 requirements for safe storage of nuclear material, and it is currently being used at Los Alamos National Laboratory, Livermore National Laboratory, Idaho National Laboratory and Nevada National Security Site. The 316L stainless steel container can be manufactured in a range of sizes from 1 quart to 10 gallon capacity, it can be opened and closed easily by hand, it is sealed with a Viton{sup R} O-ring, and the filter retains particulates and resists liquid water entry while allowing hydrogen gas to escape. This innovative design has proven to provide benefits and uses beyond its original intent. For example, the container was tested in a simulated facility design basis accident involving high temperatures, fuel fire, and subsequent drop, and the damage ratio was measured. This has allowed the LANL plutonium facility to take credit for a material-at-risk reduction of approximately two orders of magnitude for material stored in the SAVY 4000 container. In addition, the water resistant filter allows the nuclear facility to credit the container as a safety feature to mitigate the risk of a criticality accident in the event of facility sprinkler system activation. The container has also been approved to transfer small quantities of solid nuclear material by hand carry between Los Alamos facilities, and it has been approved and used as a waste container for transuranic waste destined for the Waste Isolation Pilot Plant. The 1 quart capacity container and the future 2 quart design both fit inside the 9977 shipping container, and this has facilitated the transport of nuclear material from Idaho National Laboratory to Nevada Nuclear Security Site, obviated the need for repackaging the material for storage upon arrival. Finally, Los Alamos has recently contracted with Nuclear Filter Technology, Inc. to perform testing to certify the SAVY 4000 container as a DOT Type A liquid transport container. This paper will provide an overview of the various testing regimes and describe the resulting versatility of the container for nuclear material containment. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A Complex Brownfields Case Study—The Former Bannister Federal Complex, Kansas City, Missouri

Abstract In November 2017, 225 acres (91 ha) of the former Bannister Federal Complex (BFC) in Kansas City, Missouri were transferred from the Federal Government to Bannister Transformation & Development, LLC (BTD), for demolition; environmental corrective measures; and preparation of the site for redevelopment. This presented a once‐in‐a‐lifetime opportunity to reconfigure groundwater remedies and address long‐standing soil contamination issues. The property included more than 40 previously‐identified Solid Waste Management Units, 3.9 million square feet (362,000 m 2 ) of buildings, subsurface utilities dating back to the 1940s, and an active groundwater containment system. Demolition of buildings and installation of an interim groundwater containment system began almost immediately after property transfer. In 2018, BTD substantially modified its project schedule to incorporate the construction of the first new buildings while demolition and remedial activities were ongoing. By October 2020, construction of the first new warehouse commenced while excavation and capping of contaminated soils, installation of a groundwater containment treatment systems, and abandonment of legacy utilities were still underway. Completion of this work, within the originally planned timeframe, was made possible by factors including up‐front multi‐year funding, early and ongoing engagement of regulators, an extended 3‐year due diligence program and planning stage, and establishment of well‐defined environmental targets. Both the soil and groundwater remedies were also designed with the flexibility needed to accommodate unknown conditions, changing schedules, and revisions to the regrading and redevelopment plans. This case study highlights key technical and management factors that led to the successful completion of this complex brownfields remediation project.

Water Resources↗