The experiments of Biosatellite II
Biosatellite 2 onboard experiments studying weightlessness effects on biological processes and interaction with radiation from Sr 85 gamma ray source
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Biosatellite 2 onboard experiments studying weightlessness effects on biological processes and interaction with radiation from Sr 85 gamma ray source
Biomedical effects of Apollo 14 space flight, considering weightlessness adaptation
Device applies compressive force to bone to minimize loss of bone calcium during weightlessness or bedrest. Force is applied through weights, or hydraulic, pneumatic or electrically actuated devices. Device is lightweight and easy to maintain and operate.
Demonstration was performed to experimentally assess the potential advantages in the processing of materials in space, and specifically, to determine the effects of lack of density segregation and heat convection in the weightless environment of space.
Two cylindrical tanks with piston bladders and associated components for automatic filling and emptying use liquid inventory readout devices in control of water flow. Unit provides for adaptive water collection, storage, and dispensation in weightlessness environment.
The transfer of liquid from one container to another in a weightless environment was demonstrated by the crew of Apollo 14. A scale-model liquid-transfer system was used on board the spacecraft during the transearth coast period. The liquid transfer unit consisted of a surface tension baffled tank system containing two baffle designs. Liquid was transferred between tanks with a hand pump operated by the astronaut. The results showed that liquid was efficiently transferred to and from either baffled tank to within two percent of the design value residual liquid without reaching gas ingestion. The liquid-vapor interface in the receiver tank was positioned successfully with the gas located at the vent.
Preflight and postflight urine and plasma samples from the Gemini 7 and Gemini 9 crewmembers were analyzed. Electrolyte and water retention observed immediately postflight was consistent with the assumption that the Gauer-Henry atrial reflex was responsive to a change from the weightless to the unit-gravity environment. Immediately postflight, plasma 17-hydroxycorticosteroid concentrations were increased and plasma uric acid concentration was decreased. The increased excretion of 17-hydroxycorticosteroids immediately postflight probably was caused by the stress of entry. The postflight increase of plasma protein, and the slightly smaller increase of plasma electrolytes postflight, was consistent with an inflight water and electrolyte loss that resulted in postflight retention of water and electrolytes.
The experiments that were performed during the Gemini 5 and 7 missions resulted in quantitative information concerning otolithic function and orientation of four subjects exposed to an orbiting spacecraft environment for prolonged periods of time. Preflight counterrolling measurements revealed significant differences between crewmembers with regard to the basic magnitude of otolith response. However, after the flight, each crewmember maintained his respective preflight level of response. This was indicative that no significant change in otolithic sensitivity occurred as a result of the flight, or at least no change persisted long enough to be recorded several hours after recovery. The EVLH data recorded for each subject confirmed the observation that a coordinate space sense exists even in a weightless environment if contact cues are adequate. However, it was noted that the apparent location of the horizontal within the spacecraft may not agree necessarily with its physical correlate in the spacecraft.
The objective of experiment was to determine the effect of weightlessness on the ability of a fertilized frog egg to divide normally and to differentiate and form a normal embryo. This experiment was first attempted on the Gemini 8 mission and was completed only partially because of the early termination of that mission.
In an attempt to isolate behavioral, psychiatric, and sociological problems expected on long- duration space missions, a literature search was conducted at the NASA Manned Spacecraft Center, Houston, Texas. Primary sources include short - term space flights, submarine tours, Antarctic expeditions, isolation-chamber tests, space-flight simulators, and hypodynamia studies. Various stressors are discussed including weightlessness and low sensory input; circadian rhythms (including sleep); confinement, isolation, and monotony; and purely psychiatric and sociological considerations. Important aspects of crew selection are also mentioned. An attempt is made to discuss these factors with regard to a prototype mission to Mars. However, it is concluded that more experimentation under actual space conditions are necessary before such a mission should be attempted.
The results of experiments 1, 2, and 10 of the Apollo 14 composite casting demonstration are discussed. The purpose of the demonstration, with regard to samples 1 and 2, was to obtain preliminary data on the liquid phase sintering process in a weightless environment. With regard to sample 10, the purpose was to obtain preliminary information on how to achieve uniform dispersion of dense particles on a metal matrix by employing shaking modes or forces in the system when the metal matrix is molten. Results of the demonstrations were interpreted in a quantitative and qualitative manner. For experiment 1 it was found that the tungsten particles were redistributed more uniformly in the flight sample than in the control sample. Experiment 2 results indicate that complete melting may not have occured and thus a high degree of significance cannot be associated with the qualitative results relating to particle redistribution data. The particle-matrix system of experiment 10 was found to be nonwetting.
The effects of weightlessness and increased gravity on flammability and flame propagation are discussed. The test equipment and procedures for determining gravity effects are described. Comparisons are made between flammability under normal gravity conditions and occurrences under altered gravity conditions
Work that has been performed to provide information on the effects of various fire extinguishing agents in special atmospheres is discussed. Data used in the development of both equipment and techniques for manned spacecraft and related equipment are discussed. The equipment includes a hypobaric chamber suitable for low pressure use and a hyperbaric chamber for high pressure operation. The effectiveness of agents in weightless environment is also discussed.
An experimental investigation was conducted in a five-second zero gravity facility to examine the effects of venting initially saturated Refrigerant 11 from a cylindrical container (15-cm diameter) under reduced gravitational conditions. The system Bond numbers studied were 0 (weightlessness), 9 and 63; the liquid exhibited a nearly zero-degree contact angle on the container surface. During the venting process, both liquid-vapor interface and liquid bulk vaporization occurred. The temperature of the liquid in the immediate vicinity of the liquid-vapor interface was found to decrease during venting, while the liquid bulk temperature remained constant. Qualitative observations of the effects of system acceleration, vent rate, and vapor volume presented. Quantitative information concerning the ullage pressure decay during low gravity venting is also included.
The development of a functional model water reclamation system is discussed. The system produces potable water by distillation from the urine and respiration-perspiration condensate at the normal rate generated by four men. Basic processes employed are vacuum distillation, vapor filtration, vapor phase catalytic oxidation, and condensation. The system is designed to use four 75-watt isotope heaters for distillation thermal input, and one 45-watt isotope for the catalytic oxidation unit. The system is capable of collecting and storing urine, and provides for stabilizing the urine by chemical pretreatment. The functional model system is designed for operation in a weightless condition with liquid-vapor phase separators for the evaporator still, and centrifugal separators for urine collection and vapor condensation. The system provides for storing and dispensing reclaimed potable water. The system operates in a batch mode for 40 days, with urine residues accumulating in the evaporator. The evaporator still and residue are removed to storage and replaced with a fresh still for the next 40-day period.
A two liquid, neutral buoyancy technique is being used to simulate propellant behavior in a weightless environment. By equalizing the density of two immiscible liquids within a container (propellant tank), the effect of gravity at the liquid interface is balanced. Therefore the surface-tension forces dominate to control the liquid/liquid system configuration in a fashion analogous to a liquid/gas system in a zero gravity environment.
The OFO-A mission was prepared as a part of a special program of vestibular physiology with the purpose of studying in which way the lack of the gravity pull will affect the functioning of that part of the labyrinth which controls balance. The gravitational components corresponded to the different head positions, namely, the gravity sensitive or positioning receptors. It is evident that in weightlessness the gravity sensitive receptors are deprived of their primary input.
An experimental investigation was conducted to study the relative effectiveness of various outlet baffles in reducing liquid residuals resulting from the draining of hemispherically ended cylindrical tanks in a weightless environment. Three different baffles were employed. The relative effectiveness of each baffle was determined by comparing the results obtained, in the form of liquid residuals, with results for an unbaffled tank. Data indicate that all the baffles tested reduced residuals. Reductions betweem 10 and 60 percent were obtained, depending on baffle geometry and outlfow Weber number.