Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “VOLT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

7.5 kW solar array simulator

A high power solar array simulator capable of providing the input power to simultaneously operate two 30 cm diameter ion thruster power processors was designed, fabricated, and tested. The maximum power point may be set to between 150 and 7500 watts. This represents an open circuit voltage from 50 to 300 volts and a short circuit current from 4 to 36 amps. Illuminated solar cells are used as the control element. The illuminated solar cells provide a true solar cell characteristic and permit the option of simulating changes in this characteristic due to variations in solar intensity and/or temperature of the solar array. This is accomplished by changing the illumination and/or temperature of the control cells. The response of the output to a step change in load closely approximates that of an actual solar array.

Robson, R. R.↗

Low-voltage motor heater

Heater has stepdown transformer for low voltage range, variable transformer for holding within 0-to-28 volt range, and voltmeters and ammeters to monitor load and wattage. Regulated thermostat controls contactor, permitting heater to cycle.

Bezant, K. R.↗

Charge-sensitive amplifier with notched frequency response

Charge sensitive amplifier outputs bipolar pulse with maximum peak of 5 volts. This is applied to negative inputs of two high-speed comparators. These change output states only if pulse applied to negative inputs exceeds dc bias on their positive inputs. Output is transferred to digital event counter.

Stout, D. F.↗

Thermal control of power supplies with electronic packaging techniques

The analysis, design, and development work to reduce the weight and size of a standard modular power supply with a 350 watt output was summarized. By integrating low cost commercial heat pipes in the redesign of this power supply, weight was reduced by 30% from that of the previous design. The temperature was also appreciably reduced, increasing the environmental capability of the unit. A demonstration unit with a 100 watt output and a 15 volt regulator module, plus simulated output modules, was built and tested to evaluate the thermal performance of the redesigned power supply.

Source record↗

Development and fabrication of improved Schottky power diodes

Reproducible methods for the fabrication of silicon Schottky diodes have been developed for tungsten, aluminum, conventional platinum silicide, and low temperature platinum silicide. Barrier heights and barrier lowering under reverse bias have been measured, permitting the accurate prediction of forward and reverse diode characteristics. Processing procedures have been developed that permit the fabrication of large area (about 1 sq cm) mesageometry power Schottky diodes with forward and reverse characteristics that approach theoretical values. A theoretical analysis of the operation of bridge rectifier circuits has been performed, which indicates the ranges of frequency and voltage for which Schottky rectifiers are preferred to p-n junctions. Power Schottky rectifiers have been fabricated and tested for voltage ratings up to 140 volts.

Cordes, L. F.↗

Evaluation program for secondary spacecraft cells: Initial evaluation tests of General Electric Company 12.0 ampere-hour nickel-cadmium spacecraft cells for the international ultraviolet explorer

An evaluation test program was conducted to insure that all cells put into the life cycle program are of high quality by the screening of cells found to have electrolyte leakage, internal shorts, low capacity, or inability of any cell to recover its open-circuit voltage above 1.150 volts during the internal short test. The 20 cells were manufactured for the National Aeronautics and Space Administration, Goddard Space Flight Center (GSFC). The cells are from a lot of 175 cells procured for the International Ultraviolet Explorer project. Due to a change in requirements, the project selected to use 6.0 ampere-hour cells. Therefore, the remaining cells of this lot have been placed in storage at GSFC for use on a future GSFC project. All the cells are rated at 12.0 ampere-hours and contain double ceramic seals. Test limits specify those values in which a cell is to be terminated from a particular charge or discharge. Requirements are referred to as normally expected values based on past performance of aerospace nickel cadmium cells with demonstrated life characteristics.

Harkness, J. D.↗

Low-energy electron intensities at large distances over the earth's polar cap

The results of the character and temporal fluctuations study of electron intensities in the energy range of hundreds of electron volts, are reported which were measured at high latitudes and altitudes on geomagnetic field lines corresponding to those of the polar cap and magnetotail lobes. It is concluded that such electron intensities are diminutive relative to those found in other regions of the magnetosphere. Severe variations of intensities were found and the magnitudes of electron intensities appear to be strongly coupled to the directions of the interplanetary magnetic fields.

Yeager, D. M.↗

ATS-6 spacecraft surface treatment for the control of electrical discharges

The ATS-6 has been subject to potential charges as high as 11,000 volts based on onboard measurements. Thus, special measures were required to protect the spacecraft surface areas, - primarily the Earth Viewing Module, the reflector support truss, and the solar array boom that were specially processed for thermal control - from electrical discharges whose accompanying fields could destroy sensitive receiving circuits. The paper describes thermal blanket grounding criteria and techniques applied to prevent undesired discharge effects, and discusses the disturbance rate from static discharge in orbit.

Keiser, B. E.↗

Magnetospheric protons and electrons encountered by the moon in the plasma sheet

Results are summarized for a study of plasma-sheet particles (and their flow) encountered by the moon during its passage through the geomagnetic tail. The study is based on analysis of data obtained with a modulated Faraday cup on board the lunar-anchored spacecraft Explorer 35. It is shown that the electrons have a rapidly fluctuating non-Maxwellian energy distribution with a mean energy of several hundred electron volts and a density of approximately 0.2 per cu cm. Protons with energies of the order of 1 keV were usually detected above the instrument background when flowing towards earth at about 200 km/sec. It is suggested that strong terrestrial polar winds during the early history of the earth-moon system could have caused some erosion of the front side of the moon and that the relative smoothness of the same side could be explained in terms of gravitational shielding by the earth from the interplanetary rock flux.

Prakash, A.↗

Early irradiation of matter in the solar system - Magnesium /proton, neutron/ scheme

The occurrence of positive and negative Mg-26 anomalies in inclusions of the Allende meteorite is explained in terms of proton bombardment of a gas of solar composition. A significant fraction of Mg-26 in the irradiated gas is stored temporarily in the form of radioactive Al-26 by the reaction Mg-26(p, n)Al-26. Proton fluxes of 10 to the 17th power to 10 to the 19th power protons per square centimeter per year at 1 million electron volts are inferred. Aluminum-rich materials condensing from the gas phase have positive Mg-26 anomalies, whereas magnesium-rich materials have negative Mg-26 anomalies. The proton flux required to account for the observed magnesium anomalies is used to investigate possible isotopic anomalies in the elements from oxygen to argon. Detectable isotopic anomalies are predicted only for neon. The anomalous neon is virtually pure Ne-22 from Na-22 decay. The predicted amount of anomalous Ne-22 is about 10 to the -8th power cubic centimeter (at standard temperature and pressure) per milligram of sodium.

Heymann, D.↗

Saturation spectrum of the parametric decay instability in the presence of an external magnetic field

The effects of an external magnetic field on the saturation spectrum of parametric decay instabilities is examined by means of a modification of the Kuo and Fejer (1972) analysis. The main effect of the magnetic field is shown to be a decrease of the wavenumber with increasing angle between the wave vector and the magnetic field, particularly when the pump frequency is near the second harmonic of the cyclotron frequency. The spread of the phase velocities as measured in the direction of the magnetic field is significantly greater in the saturation spectrum when the pump frequency is near the second harmonic of the cyclotron frequency, facilitating the acceleration of tail electrons to energies of a few electron volts. It is suggested that this effect accounts for the greatly enhanced airglow observed (Haslett and Megill, 1974) under these conditions.

Chen, H. C.↗

Design and development of a 5 kV isolated solid state switch

This paper describes the design and fabrication of a 5000 volt isolated hybrid switch developed by Hughes Aircraft Company under contract to NASA/Lewis. Hughes did the packaging design and NASA did the circuit design. This unique microcircuit is intended for use as a shorting switch for large extraterrestrial solar cell arrays. The packaging design for the 5 kV isolated hybrid switch is different from most hybrid microcircuits in that it utilizes a compartmentalized plastic case (a portion of which is encapsulated), is not hermetic, and is designed for high voltage operation.

Holbrook, R. J.↗

Electrostatic disruption of lunar dust particles

The possibility that dust particles might explode catastrophically on the lunar surface due to electrostatic charging is examined. For the dark side along the terminator zone, dust balls and compact stony particles of micron and submicron sizes will be blown up if their surface potential is as low as a kilovolt negative. This mechanism does not operate on the sunlit side because the surface potential is only 3.5-20 volts positive.

Rhee, J. W.↗

Inexpensive pulse-train converter measures analog voltage

Converter measures small voltages or currents in presence of very large common-mode voltages (thousands of volts ac or dc). Advantages are low power consumption, transmission via single isolated channel, simplicity, and operation from single-polarity power supply.

Sturman, J. C.↗

New process produces high-power Schottky diodes

Processing procedure using low-temperature platinum silicide, results in successful high-yield fabrication of large-area mesa-geometry Schottky diodes, with reverse breakdown voltages as high as 150 volts and leak currents less than 5 milliamps at 212 F.

Cordes, L. F.↗

Preliminary report on the CTS transient event counter performance through the 1976 spring eclipse season

The transient event counter (TEC), senses and counts transients having a voltage rise of greater than five volts in three separate wire harnesses: the attitude control harness, the solar array instrumentation harness and the solar array power harness. The operational characteristics of TEC are defined and the preliminary results obtained through the first 90 days of operation including the spring 1976 eclipse season are presented. The results show that the Communications Technology Satellite was charged to the point where discharges occurred. The discharge induced transients did not cause any anomalous events in spacecraft operation. The data indicate that discharges can occur at any time during the day without preference to any local time quadrant. The number of discharges occurring in the one second sample interval are greater than anticipated. The compilation and review of the data is continuing.

Stevens, N. J.↗

Effects of neutron irradiation on the characteristics of a buried channel CCD at 80 degrees Kelvin and 295 degrees Kelvin

Buried channel CCD shift registers were irradiated with 15 MeV neutrons. The irradiations were performed at 80 K and 295 K on operating devices with normal clocks and bias voltages applied. Dark current increased from the pre-irradiation value of 7 nA/sq cm to 1,600 nA/sq cm at 1 x 10 to the 13th power n/sq cm. The input gate threshold shift observed at 80K was minus 0.9 volts per 10 to the 13th power n/sq cm, a factor of 4 less than that predicted from a first order calculation of the equivalent ionization dose of neutrons in the oxide. Transfer efficiency measurements yielded a bulk electron trap creation rate for neutron irradiation of 14.0 cm to the minus 1 power at 295 K with a trap emission time constant of 25 microseconds.

Saks, N. S.↗