Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Thomson”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

Diagnosis of high-intensity pulsed heavy ion beam generated by a novel magnetically insulated diode with gas puff plasma gun

Intense pulsed heavy ion beam is expected to be applied to materials processing including surface modification and ion implantation. For those applications, it is very important to generate high-purity ion beams with various ion species. For this purpose, we have developed a new type of a magnetically insulated ion diode with an active ion source of a gas puff plasma gun. When the ion diode was operated at a diode voltage of about 190 kV, a diode current of about 15 kA, and a pulse duration of about 100 ns, the ion beam with an ion current density of 54 A/cm{sup 2} was obtained at 50 mm downstream from the anode. By evaluating the ion species and the energy spectrum of the ion beam via a Thomson parabola spectrometer, it was confirmed that the ion beam consists of nitrogen ions (N{sup +} and N{sup 2+}) of energy of 100-400 keV and the proton impurities of energy of 90-200 keV. The purity of the beam was evaluated to be 94%. The high-purity pulsed nitrogen ion beam was successfully obtained by the developed ion diode system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Generation and manipulation of proton beams by ultra-short laser pulses

Applying a 21-channel Thomson spectrometer setup has revealed further insight to the connection between spatial and spectral beam characteristic of laser accelerated protons. Analyzing the central emission cone (plus/minus 3 degree) shows an increasing beam divergency for protons with increasing kinetic energies. This holds for protons emitted from the same source area at the target surface. The whole beam is a well ordered system with a clear functional dependence of trajectories on proton energy. This is a consequence of the source dynamics which is determined by the sheath development in time. Thus laser-driven ion beams can be advantageously manipulated for further propagation to an experiment. We demonstrate this capability with a magnetic quadrupole and obtain a nearly parallel and monochromatized beam. Furthermore we set our achievements in beam production efficiency into context with other laser systems and demonstrate the potential of very-thin target foils.

43 PARTICLE ACCELERATORS↗

Shell Structure, Melting and Dynamics of Ion Clusters Confined in an Octupolar Trap

The stable structures of clusters of identical ions trapped in an isotropic octupolar trap are investigated using global optimization methods. These clusters form well defined shells of ions that are approximately solutions of the Thomson problem. In particular, magic numbers are found to correlate with highly symmetric configurations. Using Monte Carlo simulations, finite temperature properties are also investigated. Melting proceeds from the core, and takes place through a very progressive loss of the shell structure. The hollow shape is eventually lost at very high temperatures, where the ions essentially feel the confinement but not the Coulomb repulsion. The vibrational density of states shows marked differences with the harmonic case, but also with bulk Wigner crystals. The variations of the maximal Lyapunov exponent obtained from additional molecular dynamics trajectories reveals that the dynamics becomes increasingly chaotic as the temperature increases. With the decreasing influence of the Coulomb interaction, a more regular behavior is found at very high temperatures but, contrary to the quadrupolar case, still highly chaotic.

74 ATOMIC AND MOLECULAR PHYSICS↗

The Astro-H Soft X-ray Spectrometer (SXS)

The Soft-X-ray Spectrometer (SXS) is a high spectral resolution, cryogenic x-ray spectrometer that will fly on the Japan/U.S. Astro-H observatory in 2014. The SXS is composed of a 36 pixel, imaging, x-ray calorimeter array that will operate at 0.05 K utilizing a 2-stage adiabatic demagnetization refrigerator and a redundant pre-cooler design using both a 40 liter liquid helium tank and a 1.7 K Joule-Thomson (JT) cryocooler. Additional redundant Stirling cycle coolers provide pre-cooling for the (JT) and cool the outer thermal shields for the JT and the helium tank. The detector system, while similar to that flown on Suzaku, is composed of larger 0.81x0.81mm pixels, but has significantly better performance, currently predicted to be better than 4 eV FWHM at 6 keV with 95% quantum efficiency. This instrument is the result of a close collaboration between many institutions in the U.S. and Japan over the last 25 years. Here we will present an overview of the SXS instrument, the SXS cooling system, and recent laboratory improvements to the detector system.0.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A MAPLE Package for Energy-Momentum Tensor Assessment in Curved Space-Time

One of the most interesting problem which remain unsolved, since the birth of the General Theory of Relativity (GR), is the energy-momentum localization. All our reflections are within the Lagrange formalism of the field theory. The concept of the energy-momentum tensor for gravitational interactions has a long history. To find a generally accepted expression, there have been different attempts. This paper is dedicated to the investigation of the energy-momentum problem in the theory of General Relativity. We use Einstein [1], Landau-Lifshitz [2], Bergmann-Thomson [3] and Moller's [4] prescriptions to evaluate energy-momentum distribution. In order to cover the huge volume of computation and, bearing in mind to make a general approaching for different space-time configurations, a MAPLE application to succeed in studying the energy momentum tensor was built. In the second part of the paper for two space-time configuration, the comparative results were presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

OPTIMIZATION OF A TWO-STAGE ADR FOR THE SOFT X-RAY SPECTROMETER (SXS) INSTRUMENT ON THE ASTRO-H MISSION

NASA/Goddard Space Flight Center has begun developing the Soft X-ray Spectrometer (SXS) instrument that will be flown on the Japanese Astro-H mission. The SXS's 36-pixel detector array will be cooled to 50 mK using a two-stage adiabatic demagnetization refrigerator (ADR). A complicating factor for its design is that the ADR will be integrated into a superfluid helium dewar at 1.3 K that will be coupled to a 1.8 K Joule-Thomson (JT) stage through a heat switch. When liquid helium is present, the coupling will be weak, and the JT stage will act primarily as a shield to reduce parasitic heat loads. When the liquid is depleted, the heat switch will couple more strongly so that the ADR can continue to operate using the JT stage as its heat sink. A two-stage ADR is the most mass efficient option and it has the operational flexibility to work well with a stored cryogen and a cryocooler. The stages are operated independently, and this opens up a very large parameter space for optimizing the design. This paper discusses the optimization process and most relevant trades considered in the design of the SXS ADR, and its expected performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Tomography of an ultrafast laser driven proton source

Using a multichannel Thomson spectrometer we have implemented a tomographic approach allowing the reconstruction of the emission characteristic of a laser driven proton source with high energy and spatial resolution. The results demonstrate the complexity of the temporal and spatial characteristics of such a source. The emitted proton beam, which is laminar and divergent at high energies, becomes convergent at low energies. This implies that a fraction of the proton beam having this kinetic energy is emitted in a collimated way from the target at the ''turning point'' between these two behaviors. Only a finite fraction of the target surface is contributing to the ion spectrum, which is measured at a specific angle within the beam cone. Therefore the momentum distribution of the protons in the emitted beam at any point in space can be controlled by determining the proton source area.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Density measurements using coherence imaging spectroscopy based on Stark broadening

A coherence imaging camera has been set up at Pilot-PSI. The system is to be used for imaging the plasma density through the Stark effect broadening of the H{sub {gamma}} line. Local density values are then obtained by the Abel inversion of the measured interferometric fringe contrast. This report will present the instrument setup and proof-of-principle demonstration. The inverted spatial electron density profiles obtained near the cascaded arc source of Pilot-PSI in discharges with axial magnetic field of B=0.4 T are compared with an independent measurement of electron density by Thomson scattering and good agreement is found.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Laser-Plasma Wakefield Acceleration with Higher Order Laser Modes

Laser-plasma collider designs point to staging of multiple accelerator stages at the 10 GeV level, which are to be developed on the upcoming BELLA laser, while Thomson Gamma source designs use GeV stages, both requiring efficiency and low emittance. Design and scaling of stages operating in the quasi-linear regime to address these needs are presented using simulations in the VORPAL framework. In addition to allowing symmetric acceleration of electrons and positrons, which is important for colliders, this regime has the property that the plasma wakefield is proportional to the transverse gradient of the laser intensity profile. We demonstrate use of higher order laser modes to tailor the laser pulse and hence the transverse focusing forces in the plasma. In particular, we show that by using higher order laser modes, we can reduce the focusing fields and hence increase the matched electron beam radius, which is important to increased charge and efficiency, while keeping the low bunch emittance required for applications.

43 PARTICLE ACCELERATORS↗

Narrow Energy Spread Protons and Ions from High-Intensity, High-Contrast Laser Solid Target Interactions

Recent simulations show that an idealized, high intensity, short pulse laser can generate quasi-monoenergetic proton beams with energies over 100 MeV in an interaction with a thin film. However, most short pulse laser facilities with sufficient intensity have difficulty controlling the nanosecond and picosecond contrast necessary to realize such a regime. Experiments were performed to investigate proton and ion acceleration from a high contrast, short pulse laser by employing dual plasma mirrors along with a deformable mirror at the HERCULES laser facility at the Center for Ultrafast Optical Sciences, University of Michigan. Plasma mirrors were characterized, allowing a 50% throughput with an intensity contrast increase of 105. The focal spot quality was also exceptional, showing a 1.1 micron full width at half maximum (FWHM) focal diameter. Experiments were done using temporally cleaned 30 TW, 32 fs pulses to achieve an intensity of up to 10{sup 21} Wcm{sup -2} on Si{sub 3}N{sub 4} and Mylar targets with thicknesses ranging 50 nm to 13 microns. Proton beams with energy spreads below 2 MeV were observed from all thicknesses, peaking with energies up to 10.3 MeV and an energy spread of 0.8 MeV. Similar narrow energy spreads were observed for oxygen, nitrogen, and carbon at the silicon nitride thickness of 50 nm with energies up to 24 MeV with an energy spread of 3 MeV, whereas the energy spread is greatly increased at a larger thickness. Maximum energies were confirmed with CR39 track detectors, while a Thomson ion spectrometer was used to gauge the monoenergetic nature of the beam.

43 PARTICLE ACCELERATORS↗

Production of neutrons up to 18 MeV in high-intensity, short-pulse laser matter interactions

The generation of high-energy neutrons using laser-accelerated ions is demonstrated experimentally using the Titan laser with 360 J of laser energy in a 9 ps pulse. In this technique, a short-pulse, high-energy laser accelerates deuterons from a CD{sub 2} foil. These are incident on a LiF foil and subsequently create high energy neutrons through the {sup 7}Li(d,xn) nuclear reaction (Q = 15 MeV). Radiochromic film and a Thomson parabola ion-spectrometer were used to diagnose the laser accelerated deuterons and protons. Conversion efficiency into protons was 0.5%, an order of magnitude greater than into deuterons. Maximum neutron energy was shown to be angularly dependent with up to 18 MeV neutrons observed in the forward direction using neutron time-of-flight spectrometry. Absolutely calibrated CR-39 detected spectrally integrated neutron fluence of up to 8 x 10{sup 8} n sr{sup -1} in the forward direction.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Stable formation of ultrahigh power-density 248 nm channels in Xe cluster targets

The optimization of relativistic and ponderomotive self-channeling of ultra-powerful 248 nm laser pulses launched in underdense plasmas with an appropriate longitudinal gradient in the electron density profile located at the initial stage of the self-channeling leads to (1) stable channel formation and (2) highly efficient power compression producing power densities in the 10{sup 19}-10{sup 20} W/cm{sup 3} range. The comparison of theoretical studies with experimental results involving the correlation of (a) Thomson images of the electron density with (b) x-ray images of the channel morphology demonstrates that more than 90% of the incident 248 nm power can be trapped in stable channels and that this stable propagation can be extended to power levels significantly exceeding the critical power of the self-channeling process.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Heavy-ion emission from short-pulse laser-plasma interactions with thin foils

A Thomson parabola ion spectrometer, implemented on the Laboratory for Laser Energetics Multi-Terawatt laser facility, has been used to study heavy-ion acceleration from ultra-intense laser-plasma interactions. These studies were conducted using 20 {mu}m-thick flat foil targets with on-target intensities of 4-5 Multiplication-Sign 10{sup 19} W-cm{sup -2}. Several charge states of energetic heavy ions were accelerated from the rear of Al and Cu foils in the presence of hydrocarbon contaminants. In contrast to previous work, we show that the mean and maximum energies of each heavy-ion species scale linearly with only the charge of the ion, and not the charge-to-mass ratio, implying that the space-charge is not readily depleted as ions expand. It has been shown previously and observed here that the maximum heavy-ion energies are lower than that of protons, though a fundamental explanation for this discrepancy has not been provided. We show how a two-temperature electron distribution, observed in these experiments, explains these observations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A scintillator-based online detector for the angularly resolved measurement of laser-accelerated proton spectra

In recent years, a new generation of high repetition rate ({approx}10 Hz), high power ({approx}100 TW) laser systems has stimulated intense research on laser-driven sources for fast protons. Considering experimental instrumentation, this development requires online diagnostics for protons to be added to the established offline detection tools such as solid state track detectors or radiochromic films. In this article, we present the design and characterization of a scintillator-based online detector that gives access to the angularly resolved proton distribution along one spatial dimension and resolves 10 different proton energy ranges. Conceived as an online detector for key parameters in laser-proton acceleration, such as the maximum proton energy and the angular distribution, the detector features a spatial resolution of {approx}1.3 mm and a spectral resolution better than 1.5 MeV for a maximum proton energy above 12 MeV in the current design. Regarding its areas of application, we consider the detector a useful complement to radiochromic films and Thomson parabola spectrometers, capable to give immediate feedback on the experimental performance. The detector was characterized at an electrostatic Van de Graaff tandetron accelerator and tested in a laser-proton acceleration experiment, proving its suitability as a diagnostic device for laser-accelerated protons.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of diagnostic and manipulation systems for space-charge dominated electron beams and confined electron plasmas in ELTRAP

Modifications have been implemented in the Penning-Malmberg device ELTRAP aimed at performing studies on the dynamics of space-charge dominated nanosecond electron bunches traveling along the magnetic field. In particular, a Thomson backscattering apparatus has been developed where an infrared (IR) laser pulse collides with the bunched electron beam. The frequency-shifted backscattered radiation, acquired by means of a photomultiplier (PMT), can be exploited to evaluate information on energy, energy spread and density of the bunch. The achievable sensitivity of the diagnostics has been estimated, and valuable information on the main parameters affecting the signal-to-noise (S/N) ratio has been obtained [B. Paroli, F. Cavaliere, M. Cavenago, F. De Luca, M. Ikram, G. Maero, C. Marini, R. Pozzoli, and M. Rome, JINST 7, P01008 (2012)]. A series of upgrades are under way, aimed at increasing the S/N ratio through the use of a new laser for the electron source, the insertion of a stray light shield, and the optimization of the detection electronics. Moreover, electromagnetic simulations relevant to the design and implementation of a microwave heating system are presented. The generation of an electron plasma in ELTRAP by means of a low-power radio frequency (RF) drive in the MHz range applied on one of the trap electrodes and under ultra-high vacuum (UHV) conditions has previously been demonstrated [B. Paroli, F. De Luca, G. Maero, F. Pozzoli, and M. Rome, Plasma Sources Sci. Technol. 19, 045013 (2010)]. The new heating system will allow the extension of the RF studies to the GHz range and in particular the production of a more energetic electron plasma via cyclotron resonant excitation.

43 PARTICLE ACCELERATORS↗

Study of X-pinch dynamics using a low current (25 kA) and slower current (400 ns) pulse

We report on experiments examining the dynamics of low current (25 kA), long rise-time (400 ns) X-pinches. The experiments used two- and four-wire 5 {mu}m tungsten X-pinches. We discuss coronal plasma dynamics, X-ray emission, cross-point evolution, and axial column dynamics. We show that the pinch dynamics are akin to those in X-pinches driven by 0.1-1 MA and at rise-rates from 0.25 to 10 kA/ns. We observe soft X-rays ({approx}1-2 keV range) emitted from the cross point in both two-wire and four-wire X-pinches at about peak current. These results show that compact current generators consisting of 2-4 small capacitors in a simple capacitive discharge circuit can produce good quality pinches for applications in Thomson X-ray scattering and backlighting among others.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Time evolution analysis of the electron distribution in Thomson/Compton back-scattering

We present the time evolution of the energy distribution of a relativistic electron beam after the Compton back-scattering with a counter-propagating laser field, performed in the framework of the Quantum Electrodynamics, by means of the code CAIN. As the correct angular distribution of the spontaneous emission is accounted, the main effect is the formation of few stripes, followed by the diffusion of the more energetic particles toward lower values in the longitudinal phase space. The Chapman-Kolmogorov master equation gives results in striking agreement with the numerical ones. An experiment on the Thomson source at SPARC-LAB is proposed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Characteristics of a liquid-helium-free calibration apparatus for cryogenic thermometers

Closed-cycle Joule-Thomson (JT) cryocoolers have been developed at National Metrology Institute of Japan (NMIJ)/National Institute of Advanced Industrial Science and Technology (AIST) with the aim of realizing a liquid-helium-free calibration apparatus for cryogenic thermometers between 0.65 K and 25 K. The latest JT cryocooler at NMIJ/AIST consists of a {sup 3}He JT cooling circuit and a pulse tube mechanical refrigerator. The characteristics of the apparatus including a residual gas analysis of the JT cooling circuit are presented in this paper. Currently the initial cool-down is performed using a heat-exchange gas. It normally takes about 30 h to reduce the temperature from room temperature to 5 K at the thermometer comparison block of the apparatus. The correct timing of the removal of the heatexchange gas is important for the efficient operation of the apparatus. Incomplete removal of the heat-exchange gas induces excess heat load on the apparatus and thermal disturbances. Some examples of abrupt temperature bursts are discussed in this paper. Mechanical refrigerators generate cyclic mechanical vibrations, and precision resistance thermometers are usually very sensitive to a mechanical vibration. The measured vibration level of the developed apparatus is reported. The damage to the apparatus due to the magnitude 9.0 earthquake on March 11, 2011, and possible countermeasures in the case of future earthquakes are also discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗