Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Tank testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

Evaluation of Hanford 200 West Area Tank Farms (241-S/241-SX-/241-U tank farms) Physical Properties Data for Use in Development of West Area Tank Treatment (WATT) Processing

With the recent acceptance of West Area Tank Treatment disposition alternative for 200 West Area tanks at the Hanford Site by the State of Washington and the U.S. Department of Energy, a review was initiated to identify the physical properties data available in the literature for the Hanford 241-S, 241-SX, and 241-U tank farms. The literature reviewed indicated that there is a relatively small set of useful data on physical properties of 200 West Area tanks, and the data that do exist are biased around a narrow range of tank samples. Much of the testing between the 1990s and mid-2010s was intended to support either enhanced sludge washing or feed delivery to the Pretreatment Facility at the Hanford Waste Treatment and Immobilization Plant. As such, some physical properties of 200 West Area samples were measured under conditions that are no longer relevant. Because of the distinctly different nature of many past processes at the 200 West Area compared to the 200 East Area, insight from waste testing in the 200 East Area waste should be used with caution, as there may be significantly different qualities in the physical properties data between these two areas (both in situ and as measured in laboratory analyses). Based on this assessment, there is a need to collect additional physical property data to support planning for 200 West Area retrievals.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Pressurant requirements for discharge of liquid methane from a 1.52-meter-(5-ft-) diameter spherical tank under both static and slosh conditions

Pressurized expulsion tests were conducted to determine the effect of various physical parameters on the pressurant gas (methane, helium, hydrogen, and nitrogen) requirements during the expulsion of liquid methane from a 1.52-meter-(5-ft-) diameter spherical tank and to compare results with those predicted by an analytical program. Also studied were the effects on methane, helium, and hydrogen pressurant requirements of various slosh excitation frequencies and amplitudes, both with and without slosh suppressing baffles in the tank. The experimental results when using gaseous methane, helium, and hydrogen show that the predictions of the analytical program agreed well with the actual pressurant requirements for static tank expulsions. The analytical program could not be used for gaseous nitrogen expulsions because of the large quantities of nitrogen which can dissolve in liquid methane. Under slosh conditions, a pronounced increase in gaseous methane requirements was observed relative to results obtained for the static tank expulsions. Slight decreases in the helium and hydrogen requirements were noted under similar test conditions.

Dewitt, R. L.↗

Liquid Hydrogen Tank Chill and No-Vent Fill Prediction using Computational Fluid Dynamics

Cryogenic tank chill and fill is an important cryogenic fluid management technology that supports and enables many of NASA’s long-duration space missions. For no-vent fill, the receiver tank pressure remains below the supply tank pressure during the entire duration of the fill so that the tank does not require venting. This is especially advantageous for tank fill operations in low gravity where the position of the liquid is not always known and venting the tank may cause loss of propellant by venting liquid. In lieu of expensive tests conducted on-orbit, accurate computational models capable of predicting receiver tank pressure during cryogenic propellant tank fill may be used to reduce system and propellant mass as well as mission risk. However, these numerical models must be validated or anchored to test data. This study presents computational fluid dynamics (CFD) models with conjugate heat transfer that are used to predict a liquid hydrogen tank chill and no-vent fill ground test conducted at Lewis Research Center (now Glenn Research Center) in 1991. The specific test case chosen for model validation implemented an upward-facing jet near the bottom of a cylindrical 34-liter tank. CFD predictions are compared to experimental measurements of tank pressure, fill level, and wall temperature. The CFD results show reasonable agreement to the test data but overpredict the pressure collapse near the end of the fill despite the liquid jet penetrating the liquid-vapor interface.

Computational Fluid Dynamics↗

Affinity and Treatment of LDR Organics in Low Activity Waste by Cementitious Materials – 26109

The physiochemical interactions between organic contaminants, minerals, and polymer additives in grout/cementitious materials are being identified. This research supports a proposed Resource Conservation and Recovery Act (RCRA) treatment variance relevant to the Land Disposal Restriction (LDR) organics present in Hanford tank waste. It provides the technical basis to address the aspects documented by the Environmental Protection Agency in a draft memo necessary to establish that organics can be immobilized/stabilized in a cementitious matrix. The organic species may interact with cementitious minerals, including slag, fly ash, cement, and other components/dopants like activated carbon. A list of 132 reasonably expected LDR organics associated with Hanford tank waste (RPP-RPT-63493, Rev 1a) was screened by functional groups, octanol-water partitioning coefficients, and detection frequency in Hanford tank waste samples. A subset of 15 compounds spanning the identified properties was tested using sorption and leachate tests. These compounds were subjected to traditional batch sorption tests and leaching tests on/from Cast Stone cementitious material with and without activated carbon (a potential organic adsorption additive). The interactions between organic compounds were observed in traditional batch sorption and modified TCLP leachate tests for surrogate Cast Stone material with and without activated carbon addition. Specifically, phthalic acid (negatively charged) and 4-chloroaniline (polar) sorbed strongly to unmodified Cast Stone, while a group of three phenolic compounds (2,4,6-Trichlorophenol, Pentachlorophenol, o-Cresol) sorbed to and were retained by Cast Stone with a 1% activated carbon amendment. Mixtures of these compounds demonstrated visible retention of the organics within the matrix with a quantifiable affinity of the organics to the cement. This novel testing supports the notion that organics within Hanford tank waste would be retained onto the cement phase with the addition of simple materials easily added to the formulation as part of the treatment process. To further provide additional support to this claim, models employing Flory-Huggins theory in conjunction with macromolecular and organic molecule solubility parameters and species activity coefficients are being utilized to better understand these interactions. Within this context, Van Krevelen (VK) and Hansen organic and polymer solubility parameters were used to inform the Flory-Huggins interaction parameter, allowing for a quantifiable method of evaluating polymer-solvent compatibility and, by extension, interactions with proposed binding additives (e.g., activated carbon). These models and measurement should test the hypothesis for our systems understanding and applicability of Flory-Huggins theory, and whether the prediction of organics in the polymer phase versus the aqueous phase can be confidently made using this strategy. The estimation of the organic molecular activity coefficient in these high salt-saturated aqueous systems is another factor that will be assessed. This project aims to predict and understand complicated organic interactions in these heterogenous systems, guiding optimal treatment and stabilization methodologies.

Jolin, Will [Savannah River National Laboratory (S↗

Development of acceptance criteria for batches of silane primer for external tank thermal protection system bonding applications

Concluding tests for the thermogravimetric and FTIR analyses of DC 1200 silane primers are discussed as well as methods for HPLC and GC analyses and for determining titanium and silicon by atomic absorption spectroscopy. Tables summarizes results obtained for residue, ash, titanium, silicone, Si/Ti ratio, OH-absorption, the lap-shear test, and the GC headspace for alcohols.

Mikes, F.↗

Liquid Hydrogen Tank Chill and No-Vent Fill Prediction using Computational Fluid Dynamics

Cryogenic tank chill and fill is an important cryogenic fluid management (CFM) technology that supports and enables many of NASA’s long-duration space missions. For no-vent fill, the receiver tank pressure remains below the supply tank pressure during the entire duration of the fill so that the tank does not require venting. This is especially advantageous for tank fill operations in low gravity where the position of the liquid is not always known and venting the tank may cause loss of propellant by venting liquid. In lieu of expensive tests conducted on-orbit, accurate computational models capable of predicting receiver tank pressure during cryogenic propellant tank fill may be used to reduce system and propellant mass as well as mission risk. However, these numerical models must be validated or anchored to test data. This study presents a computational fluid dynamics (CFD) model with conjugate heat transfer that is used to predict a liquid hydrogen tank chill and no-vent fill ground test conducted at Lewis Research Center (now Glenn Research Center) in 1991. The specific test case chosen for model validation implemented an upward-facing jet near the bottom of a cylindrical 34 liter tank. CFD predictions are compared to experimental measurements of tank pressure, fill level, fluid temperatures, and wall temperatures. The CFD results show reasonable agreement to the test data but overpredict the pressure collapse near the end of the fill despite the liquid jet penetrating the liquid-vapor interface. Several sensitivity studies are considered due to notable uncertainties in the experiment.

Computational Fluid Dynamics↗

Liquid Hydrogen Tank Chill and No-Vent Fill Prediction Using Computational Fluid Dynamics

Cryogenic tank chill and fill is an important cryogenic fluid management (CFM) technology that supports and enables many of NASA’s long-duration space missions. For no-vent fill, the receiver tank pressure remains below the supply tank pressure during the entire duration of the fill so that the tank does not require venting. This is especially advantageous for tank fill operations in low gravity where the position of the liquid is not always known and venting the tank may cause loss of propellant by venting liquid. In lieu of expensive tests conducted on-orbit, accurate computational models capable of predicting receiver tank pressure during cryogenic propellant tank fill may be used to reduce system and propellant mass as well as mission risk. However, these numerical models must be validated or anchored to test data. This study presents a computational fluid dynamics (CFD) model with conjugate heat transfer that is used to predict a liquid hydrogen tank chill and no-vent fill ground test conducted at Lewis Research Center (now Glenn Research Center) in 1991. The specific test case chosen for model validation implemented an upward-facing jet near the bottom of a cylindrical 34 liter tank. CFD predictions are compared to experimental measurements of tank pressure, fill level, fluid temperatures, and wall temperatures. The CFD results show reasonable agreement to the test data but overpredict the pressure collapse near the end of the fill despite the liquid jet penetrating the liquid-vapor interface. Several sensitivity studies are considered due to notable uncertainties in the experiment.

Computational Fluid Dynamics↗

Remote measurement of ice thickness on the shuttle external tank surface

A passive technique is proposed for remote measurement of thickness of the ice layer formed on the external tank surface of the Shuttle during the T-2 hours period before launch. It is based on the comparison of the ratios of the intensities of three preselected near-IR wavelength bands scattered from the (test spot) and a neighboring (reference spot) on the tank surface. The Shuttle is uniformly illuminated by a battery of strategically located solar simulator lamps and banks of incadescent lamps during prelaunch period. Thus, there should be adequate radiation in the three selected bands incident on the external tank surface during the test period. It is planned to conduct a feasibility study of the proposed technique before recommending it to the KSC/SSC teams for adoption.

Singh, Jag J.↗

Component Testing of the J-2X Augmented Spark Igniter (ASI)

In support of the development of the J-2X engine, 201 low pressure, liquid oxygen / liquid hydrogen (LOX/LH2) J-2X Augmented Spark Igniter (ASI) subsystem ignition tests were conducted at Marshall Space Flight Center (MSFC). The main objective of these tests was to start the ASI within the anticipated J-2X engine start box, as well as outside of it, to check for ignition margin. The setup for the J-2X ASI component testing simulated, as much as possible, the tank-head start-up configuration of the ASI within the J-2X Engine. The ignition tests were divided into 124 vacuum start tests to simulate altitude start on a flight engine, and 77 sea-level start tests to simulate the first set of ground tests for the J-2X Engine at Stennis Space Center (SSC). Other ignition parameters that were varied included propellant tank pressures, oxidizer temperature entering the ASI oxidizer feedline, oxidizer valve timing, spark igniter condition (new versus damaged), and oxidizer and fuel feedline orifice sizes. Propellant blowdowns using venturis sized to simulate the ASI resistance allowed calculation of transient propellant mass flow rates as well as global mixture ratio for all ignition tests. Global mixture ratio within the ASI at the time of ignition varied from 0.2 to 1.2. Detailed electronics data obtained from an instrumented ignition lead allowed characterization of the breakdown voltage, sustaining voltage and energy contained in each spark as the ASI propellants ignited. Results indicated that ignition always occurred within the first five sparks when both propellants were present in the ASI chamber.

Osborne, Robin J.↗

Insoluble Solids from Salt Dissolution: Characterization and Testing

Savannah River National Laboratory (SRNL) has further characterized insoluble solids that were observed in a variable depth sample from a salt dissolution campaign in Tank 9H. The insoluble solids were determined to be predominately gibbsite, a mineral form of aluminum hydroxide. From a review of salt dissolution testing and field experience, SRNL provided a realistic estimate of 8 vol% for solids of this type is formed per volume of saltcake dissolved. This estimate was doubled to 16 vol% to account for dissolution test uncertainty and differences between in-tank settling and laboratory testing. Savannah River Mission Completion (SRMC) is currently assessing the solids formed during salt dissolution as slurried sludge for hydrogen retention and release, which is driving flammability controls during salt dissolution activities. SRMC has requested SRNL perform a gas retention and release study to better understand the impact of the insoluble solids on waste tank flammability, and to provide a more accurate estimate of their ability to retain and release flammable gases.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Conceptual Design for a Blanket Tritium Extraction Test Stand

Future fusion reactors must be able to breed the tritium they will consume. Several breeding and tritium extraction technologies are under investigation internationally. PbLi is of particular interest as a breeder material. A new forced convection PbLi loop, the Tritium Extraction eXperiment (TEX), is being designed and constructed to investigate tritium extraction from PbLi. Specifically, TEX will serve to investigate the extraction efficiency of various vacuum permeator membranes and configurations. The major components of the loop include a moving magnet pump, reverse permeator, furnace test section, analysis chamber, supply tank, and plenum. As significant hazards are present in such experiments, safety is an integral focus of the experimental design.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Glass Property-Composition Models Update for use in Direct Feed High-Level Waste Flowsheet Development

A set of preliminary glass property models and constraints were developed and augmented by models from literature for use in design of direct-feed high-level waste (DFHLW) glasses for flowsheet evaluation, testing, and design of the Tank Waste Treatment and Immobilization Plant (WTP) high-level waste (HLW) Facility. These models and constraints are meant to be used as a place-holder while glass property-composition data gaps are filled and final plant operating models are developed. This report describes the motivation and intended use of the models, the compilation of data, model fitting and selection, methods to apply the models and constraints in glass design and offers example calculations demonstrating their intended use.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Characteristics and performance of a superconducting bumpy-torus magnet facility for plasma research

The NASA Lewis bumpy-torus facility consists of 12 superconducting coils, each 19 cm i.d. and capable of 3.0 T on its axis. The coils are equally spaced around a toroidal array with a major diameter of 1.52 m; they are mounted with the major axis of the torus vertical in a single vacuum tank 2.6 m in diameter. Tests of the facility mapped out its magnetic, cryogenic, vacuum, mechanical, and electrical performance. The design value of the maximum magnetic field on the magnetic axis, 3.0 T, was reached and exceeded. A maximum magnetic field of 3.23 T was held for a period of 60 minutes. When the coils were charged to a maximum magnetic field of 3.35 T, the coil system went normal without apparent damage or degradation of performance.

Roth, J. R.↗

A multiple thruster array for 30-cm thrusters

A 3.0 m diameter chamber of the 7.6 m diameter by 21.4 m long vacuum tank was modified to permit testing of an array of up to six 30-cm thrusters with a variety of laboratory and thermal vacuum breadboard power systems. A primary objective of the Multiple Thruster Array (MTA) program is to assess the impact of multiple thruster operation on individual thruster and power processor requirements. The areas of thruster startup, steady-state operation, throttling, high voltage recycle, thrust vectoring, and shutdown are of special concern. The results of initial tests are reported.

Rawlin, V. K.↗

NEP facilities (LeRC)

The topics are presented in viewgraph form and include the following: the Electric Propulsion Research Building (no. 16) the Electric Power Laboratory (BLDG. 301); the Tank 6 Vacuum Facility; and test facilities for electric propulsion and LeRC.

Vetrone, Robert H.↗

Application of elastic and elastic-plastic fracture mechanics methods to surface flaws

Fuel tanks that are a part of the External Tank assembly for the Space Shuttle are made of relatively thin 2219-T87 aluminum plate. These tanks contain about 917 m of fusion weld seam, all of which is nondestructively inspected for flaws and all those found are repaired. The tanks are subsequently proof-tested to a pressure that is sufficiently severe to cause weld metal yielding in a few local regions of the weld seam. The work undertaken in the present project was to develop a capability to predict flaw growth from undetected surface flaws that are assumed to be located in the highly stressed regions. The technical challenge was to develop R-curve prediction capability for surface cracks in specimens that contain the flaws of unusual sizes and shapes deemed to be of interest. The test techniques developed and the elastic-plastic analysis concepts adopted are presented. The flaws of interest were quite small surface cracks that were narrow-deep ellipses that served to exacerbate the technical difficulties involved.

Mccabe, Donald E.↗