Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “TIME SIGNAL”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

Complementary Paired G4FETs as Voltage-Controlled NDR Device

It is possible to synthesize a voltage-controlled negative-differential-resistance (NDR) device or circuit by use of a pair of complementary G4FETs (four-gate field-effect transistors). [For more information about G4FETs, please see the immediately preceding article]. As shown in Figure 1, the present voltage-controlled NDR device or circuit is an updated version of a prior NDR device or circuit, known as a lambda diode, that contains a pair of complementary junction field-effect transistors (JFETs). (The lambda diode is so named because its current-versus- voltage plot bears some resemblance to an upper-case lambda.) The present version can be derived from the prior version by substituting G4FETs for the JFETs and connecting both JFET gates of each G4FET together. The front gate terminals of the G4FETs constitute additional terminals (that is, terminals not available in the older JFET version) to which one can apply control voltages VN and VP. Circuits in which NDR devices have been used include (1) Schmitt triggers and (2) oscillators containing inductance/ capacitance (LC) resonant circuits. Figure 2 depicts such circuits containing G4FET NDR devices like that of Figure 1. In the Schmitt trigger shown here, the G4FET NDR is loaded with an ordinary inversion-mode, p-channel, metal oxide/semiconductor field-effect transistor (inversion-mode PMOSFET), the VN terminal of the G4FET NDR device is used as an input terminal, and the input terminals of the PMOSFET and the G4FET NDR device are connected. VP can be used as an extra control voltage (that is, a control voltage not available in a typical prior Schmitt trigger) for adjusting the pinch-off voltage of the p-channel G4FET and thereby adjusting the trigger-voltage window. In the oscillator, a G4FET NDR device is loaded with a conventional LC tank circuit. As in other LC NDR oscillators, oscillation occurs because the NDR counteracts the resistance in the tank circuit. The advantage of this G4FET-NDR LC oscillator over a conventional LC NDR oscillator is that one can apply a time-varying signal to one of the extra control input terminals (VN or VP) to modulate the conductance of the NDR device and thereby amplitude-modulate the output signal.

Mojarradi, Mohammad↗

Blood monitoring systems and methods thereof

A blood monitoring system is capable of monitoring the blood of a subject in vivo. The blood monitoring system comprises: 1) an array of movable microneedle micromachined within associated wells; 2) array of motion actuators able to move each needle in and out of their associated wells; 3) array of microvalves associated with each microneedle able to control the flow of air around the microneedle; 4) an array of chemical sensors inserted into patient by movable microneedles; 5) an array of inductors able to measure chemical concentration in the vicinity of inserted chemical sensors; 6) conducting vias that provide timed actuating signal signals from a control system to each motion actuator; 7) conducting vias that transmit signal produced by array of chemical sensors to the control system for processing, although the blood monitoring system can comprise other numbers and types of elements in other configurations.

Mir, Jose↗

Estimation of subsurface thermal structure using sea surface height and sea surface temperature

A method of determining a subsurface temperature in a body of water is disclosed. The method includes obtaining surface temperature anomaly data and surface height anomaly data of the body of water for a region of interest, and also obtaining subsurface temperature anomaly data for the region of interest at a plurality of depths. The method further includes regressing the obtained surface temperature anomaly data and surface height anomaly data for the region of interest with the obtained subsurface temperature anomaly data for the plurality of depths to generate regression coefficients, estimating a subsurface temperature at one or more other depths for the region of interest based on the generated regression coefficients and outputting the estimated subsurface temperature at the one or more other depths. Using the estimated subsurface temperature, signal propagation times and trajectories of marine life in the body of water are determined.

Kang, Yong Q.↗

Mirror Illumination and Spillover Measurements of the Atacama Cosmology Telescope

The Atacama Cosmology Telescope (ACT) is a 6 m telescope designed to map the Cosmic Microwave Background (CMB) simultaneously at 145 GHz, 220GHz and 280GHz, The receiver in ACT, the Millimeter Bolometer Array Camera, features 1000 TES bolometers in each band, The detector performance depends critically on the total optical loading, requiring the spmover contributions from the optics to be minimal. This inspired the use of a cold Lyot stop to limit the illumination of the primary and the use of guard rings surrounding the primary and secondary reflectors. Here, we present a direct measurement of the illumination aperture for both reflectors and of the attenuation level outside the main optical path. We used a 145 GHz, 1 m W source and a chopper wheel to produce a time-varying signal with a broad heam proflle, We sampled the response of the camera for different locations of the source, placed in front and beside the primary and secondary mirrors. The aperture of the primary was measured to be 5,72 plus or minus 0,17m in diameter (95 plus or minus 3% of its geometrical size), while the aperture of the secondary yielded 2 plus or minus 0.12m in diameter. Both apertures are consistent with the optical design. Comparing to previous measurements of the beam solid angle from planet observations, we estimate an optical efficiency of 72.3 plus or minus 4,8%. We found that the attenuation outside the primary aperture was -16 plus or minus 2dB, which is below the theoretical expectations, and -22 plus or minus 1 dB outside the secondary aperture, which is consistent with simulations. These results motivated the extension of the baffles surrounding the secondary mirror, with the following reduction in detector optical loading from 2,24 pW to 188pW.

Gallardo, Patricio↗

Fourier Domain Sensing

Methods and systems are disclosed of sensing an object. A first radiation is spatially modulated to generate a structured second radiation. The object is illuminated with the structured second radiation such that the object produces a third radiation in response. Apart from any spatially dependent delay, a time variation of the third radiation is spatially independent. With a single-element detector, a portion of the third radiation is detected from locations on the object simultaneously. At least one characteristic of a sinusoidal spatial Fourier-transform component of the object is estimated from a time-varying signal from the detected portion of the third radiation.

Feldkhun, Daniel↗

A Metric to Quantify Shared Visual Attention in Two-Person Teams

Introduction: Critical tasks in high-risk environments are often performed by teams, the members of which must work together efficiently. In some situations, the team members may have to work together to solve a particular problem, while in others it may be better for them to divide the work into separate tasks that can be completed in parallel. We hypothesize that these two team strategies can be differentiated on the basis of shared visual attention, measured by gaze tracking. 2) Methods: Gaze recordings were obtained for two-person flight crews flying a high-fidelity simulator (Gontar, Hoermann, 2014). Gaze was categorized with respect to 12 areas of interest (AOIs). We used these data to construct time series of 12 dimensional vectors, with each vector component representing one of the AOIs. At each time step, each vector component was set to 0, except for the one corresponding to the currently fixated AOI, which was set to 1. This time series could then be averaged in time, with the averaging window time (t) as a variable parameter. For example, when we average with a t of one minute, each vector component represents the proportion of time that the corresponding AOI was fixated within the corresponding one minute interval. We then computed the Pearson product-moment correlation coefficient between the gaze proportion vectors for each of the two crew members, at each point in time, resulting in a signal representing the time-varying correlation between gaze behaviors. We determined criteria for concluding correlated gaze behavior using two methods: first, a permutation test was applied to the subjects' data. When one crew member's gaze proportion vector is correlated with a random time sample from the other crewmember's data, a distribution of correlation values is obtained that differs markedly from the distribution obtained from temporally aligned samples. In addition to validating that the gaze tracker was functioning reasonably well, this also allows us to compute probabilities of coordinated behavior for each value of the correlation. As an alternative, we also tabulated distributions of correlation coefficients for synthetic data sets, in which the behavior was modeled as a first-order Markov process, and compared correlation distributions for identical processes with those for disparate processes, allowing us to choose criteria and estimate error rates. 3) Discussion: Our method of gaze correlation is able to measure shared visual attention, and can distinguish between activities involving different instruments. We plan to analyze whether pilots strategies of sharing visual attention can predict performance. Possible measurements of performance include expert ratings from instructors, fuel consumption, total task time, and failure rate. While developed for two-person crews, our approach can be applied to larger groups, using intra-class correlation coefficients instead of the Pearson product-moment correlation.

Gontar, Patrick↗

On-Orbit Tracking of Sub-Sample Gain Differences in SNPP and NOAA-20 VIIRS Imagery Bands

The VIIRS instruments on board the SNPP and NOAA-20 (N20) satellites have 14 reflective solar bands covering a spectral range from 412 nm to 2250 nm. Three of these are imaging bands (I bands) with a nadir spatial resolution of 375 m and 11 are moderate resolution bands (M bands) with a resolution of 750 m. The higher resolution in the I bands is achieved by a combination of more detectors, with the I bands having twice as many detectors of half the size for every M band detector, and a higher data rate, with the I bands having two sub-samples for every sample of M band data. To ensure calibration accuracy, any systematic difference in the response of the two sub-samples needs to be monitored and corrected in the calibrated products. In this paper, we use the solar diffuser calibrations to monitor the gain differences between the two sub-samples of the I bands both as a function of time and signal level. We find gain differences of about 0.1% for I1, 0.3% for I2, and <0.1% for I3 that are mostly constant over the range of signal values available in the SD calibration. These values are mostly consistent throughout the mission for both instruments. The results are remarkably similar for the two VIIRS instruments, including a slightly out-of-family behavior seen in a few detectors. We discuss possible causes for the difference and the impact on the aggregated Earth view images.

On-orbit↗

Spatial Link Coverage Projections for the Glenn Research Center Communication Analysis Suite (GCAS)

Space communications are a fundamental part of every NASA mission, and reliable space communications are essential. Precise planning, simulation, and analysis of communications abilities are needed to know exactly what data rates, visibility times, and signal strength can be expected during the real missions. The goal of this work was to take a 3D icosphere, where each face was a point to be evaluated, and display the link performance onto a 2D projection of celestial bodies for links to a node location that could be spatially located at any of the icosahedral faces. 2D projections were produced for a wide range of spatial link grid sizes and compressed into low-size MAT files for ease of access and rapid implementation. The final icosahedral projections can be displayed onto various celestial body maps, using ultra-high-resolution maps for stitching. The results have proven satisfactory and are planned to support various simulation efforts.

communication link analysis↗

Real-Time Exposure Control and Instrument Operation With the NEID Spectrograph GUI

The NEID spectrograph on the WIYN 3.5-m telescope at Kitt Peak has completed its first full year of science operations and is reliably delivering sub-m/s precision radial velocity measurements. The NEID instrument control system uses the TIMS package (Bender et al. 2016), which is a client-server software system built around the twisted python software stack. During science observations, interaction with the NEID spectrograph is handled through a pair of graphical user interfaces (GUIs), written in PyQT, which wrap the underlying instrument control software and provide straightforward and reliable access to the instrument. Here, we detail the design of these interfaces and present an overview of their use for NEID operations. Observers can use the NEID GUIs to set the exposure time, signal-to-noise ratio (SNR) threshold, and other relevant parameters for observations, configure the calibration bench and observing mode, track or edit observation metadata, and monitor the current state of the instrument. These GUIs facilitate automatic spectrograph configuration and target ingestion from the nightly observing queue, which improves operational efficiency and consistency across epochs. By interfacing with the NEID exposure meter, the GUIs also allow observers to monitor the progress of individual exposures and trigger the shutter on user-defined SNR thresholds. In addition, inset plots of the instantaneous and cumulative exposure meter counts as each observation progresses allow for rapid diagnosis of changing observing conditions as well as guiding failure and other emergent issues.

Arvind F Gupta↗

A scintillating fission detector for neutron flux measurements

Neutron flux monitors are commonly used for a variety of nuclear physics applications. A scintillating neutron detector, consisting of a liquid scintillator loaded with fissionable material, has been developed, characterized, and tested in the beam line at the Los Alamos Neutron Science Center, and shows a significant improvement in neutron sensitivity compared with a conventional fission chamber. Recent research on nanocomposite-based scintillators for gamma-ray detection indicates that this approach can be extended to load nanoparticles of fissionable material into a scintillating matrix, with up to three orders of magnitude higher loading than typical fission chambers. This will result in a rugged, cost-efficient detector with high efficiency, a short signal rise time, and the ability to be used in low neutron-flux environments. Initial efforts to utilize the luminescence of uranyl oxide to eliminate the need for wavelength-shifting dyes were unsuccessful. Excitation of uranyl compounds has been reported at wavelengths ranging from 266 nm to 532 nm. However, neither the 300 nm emission of toluene, nor the 350 nm emission of PPO, nor the 410 nm emission of POPOP resulted in significant excitation of and emission by uranyl oxide. As indicated by UV/visible spectroscopy, light emitted at these wavelengths was absorbed by the colored solution. {sup 235}U remains the most attractive candidate for a fissionable scintillator, due to its high fission cross-section and lack of a threshold fission energy, but all solutions containing molecular uranium compounds will be colored, most more highly than the U{sup 6+} compounds used here. Research is therefore continuing toward the fabrication of uranium nanoparticles, in which, due to Rayleigh scattering, the coloration should be less pronounced. The characterization of the thorium-loaded liquid scintillator and the fabrication of the 100 mL detectors for use at LANSCE demonstrated the feasibility of loading fissionable material into a liquid scintillator. Analysis of beam line experiments using the thorium-loaded scintillator is underway to determine the fission event rate in the detector, for comparison with a conventional fission chamber as well as with an unloaded liquid scintillator.

36 MATERIALS SCIENCE↗

PDV Uncertainty Estimation & Methods Comparison

Several methods are presented for estimating the rapidly changing instantaneous frequency of a time varying signal that is contaminated by measurement noise. Useful a posteriori error estimates for several methods are verified numerically through Monte Carlo simulation. However, given the sampling rates of modern digitizers, sub-nanosecond variations in velocity are shown to be reliably measurable in most (but not all) cases. Results support the hypothesis that in many PDV regimes of interest, sub-nanosecond resolution can be achieved.

47 OTHER INSTRUMENTATION↗

Methods and systems for detecting cancer

A technique for classifying lesions as malignant or benign is disclosed. The technique can include: cooling an area of skin including a lesion of a patient to initiate a warm-up process; receiving a temporal sequence of thermal images of the area of skin representing a thermal recovery of the area of skin, the temporal sequence of thermal images generated by an infrared camera; generating a temporal profile of the thermal recovery based on the temporal sequence of thermal images; analyzing temporal statistical properties of the temporal profile; determining a malignancy probability that the lesion is malignant based on an analysis of the temporal profile, wherein the determining includes extracting one or more statistical features based on continuous-time stochastic signals in the sequence of thermal images; and classifying the lesion based on the malignancy probability.

47 OTHER INSTRUMENTATION↗

Computational Methods to Characterize Panel Loading Conditions for Accelerated Testing

Panel cracking and degradation due to wind loading are known to have a detrimental effect on power output. Recreating these damaging conditions in a controlled experimental setting requires an understanding of the loads being generated at the panel surface as a function of both wind speed, wind direction, and panel orientation. To better understand these relationships, a computational fluid dynamics (CFD) simulation package was constructed using an open-source Python library for solving partial differential equations with the finite element method. This CFD package allows the simulated wind speed and panel orientation of a multi-panel array to be easily changed and provides the capability to measure the traction forces at discrete points along the sun-facing and ground-facing surface of an interior panel residing in the wake of one or more upstream panels. A parameter exploration was performed in which the panel angle was varied in even increments from -70 deg to 70 deg and the wind speed was varied from 2 to 30 m/s. During post processing, the measured traction along the panel surface was averaged spatially and interpreted as a time-varying signal, where further processing of this signal yielded the root mean square amplitude and a characteristic frequency associated with the loading. This study found that higher wind speeds are generally associated with increased amplitude of loading and that the panel orientation angle can significantly exacerbate or mitigate this loading. These outcomes are presented along with current work on higher-fidelity verification simulations and recommendations for performing accelerated experimental testing.

loading↗

Advancements of On-Line Monitoring and Real-Time Characterization of Actual Low-Level Hanford Tank-Waste Samples

Waste and process stream characterization is essential to the safe, efficient, and cost-effective processing of Hanford Site materials. The demand for materials characterization including chemical, radionuclide, and physical attributes during waste management, transfer, and staging operations in the Hanford tank farms is expected to significantly increase as the U.S. Department of Energy River Protection Project progresses toward Hanford waste treatment and immobilization. Our past work has applied Raman on-line monitoring and chemometric modeling to the supernate of Hanford tank 241-AP-105 and has demonstrated the quantitative measurement of nine analytes within this waste. To demonstrate broader applicability, this method has now been expanded to waste from two additional Hanford tanks, AW-102 and AP-107, and the offgas condensate from lab-scale melter runs of actual-tank waste feeds. To enhance the performance of the Raman method, instruments with various excitation wavelengths were compared, since it is known that the Raman response is enhanced by shorter wavelength excitation. The laser excitations for the three systems tested were 404 nm, 532 nm, and 671 nm. In addition to laser wavelength selection, the laser power, measurement integration times, and signal averaging techniques were also investigated to determine their effect on detection limits for oxy-anion analytes within tank wastes. These advancements in Raman capability are compared with past standards and will be presented.

Bryan, Samuel A.↗

Startup process for a dual active bridge converter to prevent over-voltage failure and thermal run-away

A system and method for controlling a dual active bridge based DC/DC converter. A controller implements a startup control scheme and DC bus pre-charge routine to prevent damage to the converter upon startup. During startup of the converter, the startup control process can be used to prevent excessive phase-shift and the DC bus pre-charge routine adjusts the pulse width modulated duty cycle by increasing the dead time between signals, resulting in a decreased DC bus capacitor.

Singh, Braj K.↗

Autonomous sense and guide machine learning system

A system for generating a machine learning system to generate guidance information based on locations of objects is provided. The system accesses training data that includes training time-of-arrival (“TOA”) information of looks and guidance information for each look. The guidance information is based on a training collection of object locations. The TOA of a look represents, for each object location of a training collection of object locations, times between signals transmitted by transmitters and return signals received by receivers. The return signals represent signals reflected from an object at the object location. The system trains a machine learning system using the training data wherein the machine learning system inputs TOA information and outputs guidance information.

Beer, N. Reginald↗

Development of BPM electronics for PIP-II at Fermilab

This paper presents the uTCA4.0-based BPM electronics for PIP-II, featuring four 250 MSPS ADCs and a Xilinx UltraScale+ MPSoC FPGA with 10 GbE uplink. Design elements include signal conditioning, clock, and thermal management. The FPGA performs signal processing, time tagging, digital down-conversion, and phase drift compensation. Position and phase resolution, and thermal stability - is validated through dedicated testing.

Liu, Shengli [Fermilab] (ORCID:0009000128436936)↗