Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “TIME RESOLUTION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

Fiber-coupled Luminescence Dosimetry in Therapeutic and Diagnostic Radiology

Fiber-coupled luminescence dosimetry is an emerging technology with several potentially attractive features of relevance for uses in therapeutic and diagnostic radiology: direct water equivalence (i.e. no significant perturbation of the radiation field in a water phantom or a patient), sub-mm detector size, high dynamic range (below a mGy to several Gy), microsecond time resolution, and absence of electrical wires or other electronics in the dosimeter probe head. Fiber-coupled luminescence dosimetry systems typically consist of one or more small samples of phosphor, e.g. a mg of plastic scintillator, attached to 10-20 m long optical fiber cables of plastic. During irradiation, each dosimeter probe spontaneously emits radioluminescence (RL) in proportion to the dose rate. The luminescence intensity can be detected with photomultiplier tubes, CCD cameras or other highly sensitive photodetectors. Some crystalline phosphors, such as carbon-doped aluminium oxide (Al{sub 2}O{sub 3}:C) have the ability to store charge produced in the crystal during irradiation. The stored charge may later be released by fiber-guided laser light under emission of so-called optically stimulated luminescence (OSL). The OSL signal therefore reflects the passively integrated dose. In contrast to thermoluminescence dosimetry, fiber-coupled OSL dosimetry may be performed in vivo while the dosimeter is still in the patient. Within the last few years, several improvements and new applications of these techniques have been published, and the objective of this review is to provide an introduction to this field and to outline some of these new results. Emphasis will be given to applications in medical dosimetry such as in vivo real-time dose verification in brachytherapy and methods aimed for improved quality assurance of linear accelerators.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Plasma diagnostics in spherical tokamaks with silicon charged-particle detectors

Detection of charged fusion products, such as protons and tritons resulting from D(d, p) t reactions, can be used to determine the position and time dependent fusion reaction rate profile in spherical tokamak plasmas with neutral beam heating. We have developed a prototype instrument consisting of 6 ion-implanted-silicon surface barrier detectors combined with collimators in such a way that each detector can accept 3 MeV protons and 1 MeV tritons and thus provides a curved view across the plasma cross section. The combination of the results from all six detectors will provide information on the spatial distribution of the fusion reaction rate. The expected time resolution of about 1 ms makes it possible to study changes in the reaction rate due to slow variations in the neutral beam density profile, as well as rapid changes resulting from MHD instabilities. Details of the new instrument, its data acquisition system, simulation results, and electrical noise testing results are discussed in this paper. First experimental data are expected to be taken during the current experimental campaign at NSTX-U.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

COMPOUND TWIN CORONAL MASS EJECTIONS IN THE 2012 MAY 17 GLE EVENT

We report a multiple spacecraft observation of the 2012 May 17 GLE event. Using the coronagraph observations by SOHO/LASCO, STEREO-A/COR1, and STEREO-B/COR1, we identify two eruptions resulting in two coronal mass ejections (CMEs) that occurred in the same active region and close in time ({approx}2 minutes) in the 2012 May 17 GLE event. Both CMEs were fast. Complicated radio emissions, with multiple type II episodes, were observed from ground-based stations: Learmonth and BIRS, as well as the WAVES instrument on board the Wind spacecraft. High time-resolution SDO/AIA imaging data and SDO/HMI vector magnetic field data were also examined. A complicated pre-eruption magnetic field configuration, consisting of twisted flux-tube structure, is reconstructed. Solar energetic particles (SEPs) up to several hundred MeV nucleon{sup -1} were detected in this event. Although the eruption source region was near the west limb, the event led to ground-level enhancement. The existence of two fast CMEs and the observation of high-energy particles with ground-level enhancement agrees well with a recently proposed 'twin CME' scenario.

79 ASTRONOMY AND ASTROPHYSICS↗

A millisecond interferometric search for fast radio bursts with the very large array

We report on the first millisecond timescale radio interferometric search for the new class of transient known as fast radio bursts (FRBs). We used the Very Large Array (VLA) for a 166 hr, millisecond imaging campaign to detect and precisely localize an FRB. We observed at 1.4 GHz and produced visibilities with 5 ms time resolution over 256 MHz of bandwidth. Dedispersed images were searched for transients with dispersion measures from 0 to 3000 pc cm{sup −3}. No transients were detected in observations of high Galactic latitude fields taken from 2013 September though 2014 October. Observations of a known pulsar show that images typically had a thermal-noise limited sensitivity of 120 mJy beam{sup −1} (8σ; Stokes I) in 5 ms and could detect and localize transients over a wide field of view. Our nondetection limits the FRB rate to less than 7×10{sup 4} sky{sup −1} day{sup −1} (95% confidence) above a fluence limit of 1.5 Jy ms. The VLA rate limit is consistent with past estimates when published flux limits are recalculated with a homogeneous definition that includes effects of primary beam attenuation, dispersion, pulse width, and sky brightness. This calculation revises the FRB rate downward by a factor of 2, giving the VLA observations a roughly 50% chance of detecting a typical FRB, assuming a pulse width of 3 ms. A 95% confidence constraint would require 600 hr of similar VLA observing. Our survey also limits the repetition rate of an FRB to 2 times less than any known repeating millisecond radio transient.

79 ASTRONOMY AND ASTROPHYSICS↗

Comparative study on light-induced absorption between MgO:LiNbO{sub 3} and MgO:LiTaO{sub 3}

A comparative study on the light-induced absorption was performed for lithium niobate and lithium tantalate crystals in which the antisite defects were eliminated by MgO doping. The induced absorption was measured in a spectral window ranging from visible to near infrared with a time resolution of 10 ns. Upon pulsed-light irradiation, a broad absorption peaking near 1250 nm was induced in MgO-doped lithium niobate. It was attributed to the small free polaron, an electron trapped at the regular Nb ion site. In contrast, such absorption in the near infrared originating from the free polaron was absent in MgO-doped lithium tantalates. The findings are highly relevant to the frequency conversion performances of high-power and pulsed lasers based on the current periodically-poled devices. The results also suggest guidelines for improving the crystal qualities.

36 MATERIALS SCIENCE↗

A Geostationary Instrument Simulator for Aerosol Observing System Simulation Experiments

In the near future, there will be several new instruments measuring atmospheric composition from geostationary orbit over North America, East Asia, and Europe. This constellation of satellites will provide high resolution, time resolved measurements of trace gases and aerosols for monitoring air quality and tracking pollution sources. This paper describes a detailed, fast, and accurate (less than 1.0% uncertainty) method for calculating synthetic top of the atmosphere (TOA) radiances from a global simulation with a mesoscale free running model, the GEOS-5 Nature Run, for remote sensing instruments in geostationary orbit that measure in the ultraviolet-visible spectral range (UV-Vis). Generating these synthetic observations is the first step of an Observing System Simulation Experiment (OSSE), a framework for evaluating the impact of a new observation or algorithm. This paper provides details of the model sampling, aerosol and cloud optical properties, surface reflectance modeling, Rayleigh scattering calculations, and a discussion of the uncertainties of the simulated TOA radiance. An application for the simulated TOA radiance observations is demonstrated in the manuscript. Simulated TEMPO (Tropospheric Emissions: Monitoring of Pollution) and GOES-R (Geostationary Operational Environmental Satellites) observations were used to show how observations from the two instruments could be combined to facilitate aerosol type discrimination. The results demonstrate the viability of a detailed instrument simulator for radiance measurements in the UV-Vis that is capable of accurately simulating high resolution, time-resolved measurements with reasonable computational efficiency.

Castellanos, Patricia↗

Development of coherent Raman measurements of temperature in condensed phases

We report theoretical considerations and preliminary data on various forms of coherent Raman spectroscopy that have been considered as candidates for measurement of temperature in condensed phase experiments with picosecond time resolution. Due to the inherent broadness and congestion of vibrational features in condensed phase solids, particularly at high temperatures and pressures, only approaches that rely on the ratio of anti-Stokes to Stokes spectral features are considered. Methods that rely on resolution of vibrational progressions, calibration of frequency shifts with temperature and pressure in reference experiments, or detailed comparison to calculation are inappropriate or impossible for our applications. In particular, we consider femtosecond stimulated Raman spectroscopy (FSRS), femtosecond/picosecond hybrid coherent Raman spectroscopy (multiplex CARS), and optical heterodyne detected femtosecond Raman induced Kerr Effect spectroscopy (OHD-FRIKES). We show that only FSRS has the ability to measure temperature via an anti-Stokes to Stokes ratio of peaks.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Microbeam, timing and signal-resolved studies of nuclear materials with synchrotron X-ray sources

The development of ultra-brilliant synchrotron X-ray sources enables characterization methods that are particularly important for nuclear materials. Here we discuss emerging synchrotron methods with unprecedented signal-to-noise, spatial and time resolution. Microprobe methods are discussed that extend virtually any X-ray characterization measurement to ultra-small sample volumes. This ability is critical to resolve heterogeneities in nuclear materials and for studies on volumes with vastly lower activity than are needed for traditional X-ray characterization. Specific methods discussed include microdiffraction for the characterization of local crystal structure and micro-spectroscopy techniques that allow for characterization of elemental distributions with sensitivity for daughter products, oxidation states and diffusion through buffer layers. Opportunities are also discussed that exploit the high brilliance and pulsed nature of synchrotron radiation to reduce backgrounds from sample radiation and to study materials dynamics.

36 MATERIALS SCIENCE↗

MASS ESTIMATES OF RAPIDLY MOVING PROMINENCE MATERIAL FROM HIGH-CADENCE EUV IMAGES

We present a new method for determining the column density of erupting filament material using state-of-the-art multi-wavelength imaging data. Much of the prior work on filament/prominence structure can be divided between studies that use a polychromatic approach with targeted campaign observations and those that use synoptic observations, frequently in only one or two wavelengths. The superior time resolution, sensitivity, and near-synchronicity of data from the Solar Dynamics Observatory's Advanced Imaging Assembly allow us to combine these two techniques using photoionization continuum opacity to determine the spatial distribution of hydrogen in filament material. We apply the combined techniques to SDO/AIA observations of a filament that erupted during the spectacular coronal mass ejection on 2011 June 7. The resulting 'polychromatic opacity imaging' method offers a powerful way to track partially ionized gas as it erupts through the solar atmosphere on a regular basis, without the need for coordinated observations, thereby readily offering regular, realistic mass-distribution estimates for models of these erupting structures.

79 ASTRONOMY AND ASTROPHYSICS↗

'Giant' multishell CdSe nanocrystal quantum dots with supporessed blinking: novel fluorescent probes for real-time detection of single-molecule events

We reported for the first time that key nanocrystal quantum dot (NQD) optical properties-quantum yield, photobleaching and blinking-can be rendered independent ofNQD surface chemistry and environment by growth of a very thick, defect-free inorganic shell. Here, we show the precise shell-thickness dependence of these effects. We demonstrate that 'giant-shell' NQDs can be largely non-blinking for observation times as long as 54 minutes and lhat on-time fractions are independent of experimental time-resolution from 1-200 ms. These effects are primarily demonstrated on (CdSe)CdS (core)shell NQDs, but we also show that alloyed shells comprising Cd.Znl.'S and terminated with a non-cytotoxic ZnS layer exhibit similar properties. The mechanism for suppressed blinking and dramatically enhanced stability is attributed to both effective isolation of the NQD core excitonic wavefunction from the NQD surface, as well as a quasi-Type II electronic structure. The unusual electronic structure provides for effective spatial separation of the electron and hole into the shell and core, respectively, and, thereby, for reduced efficiencies in non-radiative Auger recombination.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Density relaxation and particle motion characteristics in a non-ionic deep eutectic solvent (acetamide + urea): Time-resolved fluorescence measurements and all-atom molecular dynamics simulations

Temperature dependent relaxation dynamics, particle motion characteristics, and heterogeneity aspects of deep eutectic solvents (DESs) made of acetamide (CH{sub 3}CONH{sub 2}) and urea (NH{sub 2}CONH{sub 2}) have been investigated by employing time-resolved fluorescence measurements and all-atom molecular dynamics simulations. Three different compositions (f) for the mixture [fCH{sub 3}CONH{sub 2} + (1 − f)NH{sub 2}CONH{sub 2}] have been studied in a temperature range of 328-353 K which is ∼120-145 K above the measured glass transition temperatures (∼207 K) of these DESs but much lower than the individual melting temperature of either of the constituents. Steady state fluorescence emission measurements using probe solutes with sharply different lifetimes do not indicate any dependence on excitation wavelength in these metastable molten systems. Time-resolved fluorescence anisotropy measurements reveal near-hydrodynamic coupling between medium viscosity and rotation of a dissolved dipolar solute. Stokes shift dynamics have been found to be too fast to be detected by the time-resolution (∼70 ps) employed, suggesting extremely rapid medium polarization relaxation. All-atom simulations reveal Gaussian distribution for particle displacements and van Hove correlations, and significant overlap between non-Gaussian (α{sub 2}) and new non-Gaussian (γ) heterogeneity parameters. In addition, no stretched exponential relaxations have been detected in the simulated wavenumber dependent acetamide dynamic structure factors. All these results are in sharp contrast to earlier observations for ionic deep eutectics with acetamide [Guchhait et al., J. Chem. Phys. 140, 104514 (2014)] and suggest a fundamental difference in interaction and dynamics between ionic and non-ionic deep eutectic solvent systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Real-time reflectance-difference spectroscopy of GaAs molecular beam epitaxy homoepitaxial growth

We report on real time-resolved Reflectance-difference (RD) spectroscopy of GaAs(001) grown by molecular beam epitaxy, with a time-resolution of 500 ms per spectrum within the 2.3–4.0 eV photon energy range. Through the analysis of transient RD spectra we demonstrated that RD line shapes are comprised of two components with different physical origins and determined their evolution during growth. Such components were ascribed to the subsurface strain induced by surface reconstruction and to surface stoichiometry. Results reported in this paper render RD spectroscopy as a powerful tool for the study of fundamental processes during the epitaxial growth of zincblende semiconductors.

36 MATERIALS SCIENCE↗

Microsecond acquisition of heterogeneous structure in the folding of a TIM barrel protein

The earliest kinetic folding events for ({beta}{alpha}){sub 8} barrels reflect the appearance of off-pathway intermediates. Continuous-flow microchannel mixing methods interfaced to small-angle x-ray scattering (SAXS), circular dichroism (CD), time-resolved Foerster resonant energy transfer (trFRET), and time-resolved fluorescence anisotropy (trFLAN) have been used to directly monitor global and specific dimensional properties of the partially folded state in the microsecond time range for a representative ({beta}{alpha}){sub 8} barrel protein. Within 150 {micro}s, the {alpha}-subunit of Trp synthase ({alpha}TS) experiences a global collapse and the partial formation of secondary structure. The time resolution of the folding reaction was enhanced with trFRET and trFLAN to show that, within 30 {micro}s, a distinct and autonomous partially collapsed structure has already formed in the N-terminal and central regions but not in the C-terminal region. A distance distribution analysis of the trFRET data confirmed the presence of a heterogeneous ensemble that persists for several hundreds of microseconds. Ready access to locally folded, stable substructures may be a hallmark of repeat-module proteins and the source of early kinetic traps in these very common motifs. Their folding free-energy landscapes should be elaborated to capture this source of frustration.

59 BASIC BIOLOGICAL SCIENCES↗

Half-life Measurements of Excited Levels in Fission Products around Mass Number 150

A spectrometer to measure nuclear level half-lives has been installed at the on-line isotope separator of the Kyoto University Reactor. This spectrometer consists of a LaBr3 scintillator, a thin plastic scintillator and an HPGe detector. Half-lives are deduced using the β-γ-γ delayed coincidence method. The prompt-time distribution curves measured with the spectrometer give a time resolution (FWHM) of 600 ps for 100-keV γ rays. This resolution means that half-lives down to the subnanosecond range or shorter can be measured. We reported recent measurements of the half-life of {sup 149}Pr and {sup 149}Nd. Some of the more interesting results include the first determination of the half-lives of {sup 149}Pr levels at 86.5 and 125.6 keV, which are 4.2(5) ns and 1.0(2) ns, respectively. In addition, the data indicate that the half-life of the 270.8-keV level in {sup 149}Nd is not 5.1(3) ns as reported previously, but 0.42(3) ns.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Ultrafast electron diffraction with radio-frequency compressed electron pulses

We report on the complete characterization of time resolution in an ultrafast electron diffraction (UED) instrument based on radio-frequency electron pulse compression. The temporal impulse response function of the instrument was determined directly in pump-probe geometry by performing electron-laser pulse cross-correlation measurements using the ponderomotive interaction. With optimal settings, a stable impulse response of 334{+-}10 fs was measured at a bunch charge of 0.1 pC (6.24 Multiplication-Sign 10{sup 5} electrons/pulse); a dramatic improvement compared to performance without pulse compression. Phase stability currently limits the impulse response of the UED diffractometer to the range of 334-500 fs, for bunch charges ranging between 0.1 and 0.6 pC.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Laser parametric instability experiments of a 3ω, 15 kJ, 6-ns laser pulse in gas-filled hohlraums at the Ligne d'Intégration Laser facility

Experimental investigation of stimulated Raman (SRS) and Brillouin (SBS) scattering have been obtained at the Ligne-d'Intégration-Laser facility (LIL, CEA-Cesta, France). The parametric instabilities (LPI) are driven by firing four laser beamlets (one quad) into millimeter size, gas-filled hohlraum targets. A quad delivers energy on target of 15 kJ at 3ω in a 6-ns shaped laser pulse. The quad is focused by means of 3ω gratings and is optically smoothed with a kinoform phase plate and with smoothing by spectral dispersion-like 2 GHz and/or 14 GHz laser bandwidth. Open- and closed-geometry hohlraums have been used, all being filled with 1-atm, neo-pentane (C{sub 5}H{sub 12}) gas. For SRS and SBS studies, the light backscattered into the focusing optics is analyzed with spectral and time resolutions. Near-backscattered light at 3ω and transmitted light at 3ω are also monitored in the open geometry case. Depending on the target geometry (plasma length and hydrodynamic evolution of the plasma), it is shown that, at maximum laser intensity about 9 × 10{sup 14} W/cm{sup 2}, Raman reflectivity noticeably increases up to 30% in 4-mm long plasmas while SBS stays below 10%. Consequently, laser transmission through long plasmas drops to about 10% of incident energy. Adding 14 GHz bandwidth to the laser always reduces LPI reflectivities, although this reduction is not dramatic.

2-METHYLBUTANE↗

Ultrafast semiconductor x-ray detector

The National Ignition Campaign has the goal of developing a burning plasma platform producing up to {approx}10{sup 19} neutrons in {approx}20 picoseconds, ps. Diagnosis will require instruments operating with a time resolution of a few ps within this extremely large neutron flux environment. A diagnostic, which performs an ultrafast conversion of the x-ray signals into the optical regime, has been developed using a linearly chirped probe beam to measure the temporal history of the x-ray pulse. This diagnostic technique was tested on a laser-produced x-ray source and obtained a measurement of the full-width-at-half-maximum, FWHM, of the x-ray pulse of {approx}7.2 ps.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Faraday rotation data analysis with least-squares elliptical fitting

A method of analyzing Faraday rotation data from pulsed magnetic field measurements is described. The method uses direct least-squares elliptical fitting to measured data. The least-squares fit conic parameters are used to rotate, translate, and rescale the measured data. Interpretation of the transformed data provides improved accuracy and time-resolution characteristics compared with many existing methods of analyzing Faraday rotation data. The method is especially useful when linear birefringence is present at the input or output of the sensing medium, or when the relative angle of the polarizers used in analysis is not aligned with precision; under these circumstances the method is shown to return the analytically correct input signal. The method may be pertinent to other applications where analysis of Lissajous figures is required, such as the velocity interferometer system for any reflector (VISAR) diagnostics. The entire algorithm is fully automated and requires no user interaction. An example of algorithm execution is shown, using data from a fiber-based Faraday rotation sensor on a capacitive discharge experiment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗