Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “TARGET SIMULATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

The production and separation of 161 Tb with high specific activity at the University of Utah

Targeted radiotherapy (TRT) is an increasingly prominent area of research in nuclear medicine, particularly in the context of treating cancerous tumors. One radionuclide of considerable interest for TRT is terbium-161 (t 1/2 = 6.95 days), which undergoes beta emission and shares similar decay properties as 177 Lu (FDA-approved as LUTATHERA® and PLUVICTO®). Besides beta emission, 161 Tb also emits a significant number of conversion and Auger electrons further enhancing its therapeutic potential. Terbium-161 can be produced using nuclear reactors through an indirect neutron capture reaction, $^{160}_{64}$Gd(n,γ) $^{161}_{64}$Gd → (3.7 min, β – ) $^{161}_{65}$Tb, from 160 Gd targets. However, a key challenge in utilizing 161 Tb for TRT lies in effectively separating target and product materials to attain high specific activity for radiolabeling. Here, we detail the production of no-carrier added 161 Tb using low flux research reactors (mean thermal (< 0.625 eV) neutron flux: 1.356 ×10 12 n • cm –2 • s –1 ) like the University of Utah TRIGA Reactor, using enriched 160 Gd 2 O 3 targets (1.5 ± 0.3 µCi of 161 Tb per mg of 160 Gd target per hour of irradiation). We also developed a separation technique based on cation exchange and extraction chromatography, suitable for mCi level irradiations with targets exceeding 200 milligrams. In a simulated full-scale irradiation, 161 Tb was successfully isolated from large mass targets using cation exchange (AG 50W-X8, with 2-hydroxyisobutyric acid at 70 mM, pH 4.75) and extraction chromatography (LN Resin, 0.5 – 0.75 M HNO 3 ) methods. Here, this resulted in high apparent molar activities of [ 161 Tb]Tb-DOTA (113 ± 3 MBq/nmol), demonstrating high purity 161 Tb relevant for potential future preclinical applications.

161Tb↗

Efficient Subset Simulation using Hamiltonian Neural Network enhanced Markov Chain Monte Carlo Methods

The Monte Carlo method delivers an unbiased estimate of the probability of failure. However, the variance of the estimate depends on the number of evaluated samples. This number must be very large for estimations of a low probability of failure. If the evaluation of each sample is computationally expensive, the crude Monte Carlo simulation strategy is impracticable. Therefore, subset simulations are used to reduce the required number of evaluations. Subset simulations require a Markov Chain Monte Carlo sampler, such as the random walk Metropolis-Hastings algorithm. The algorithm, however, struggles with sampling in low-probability regions, especially if they are narrow. As a consequence, advanced Markov Chain Monte Carlo simulations have been developed. In particular, the Hamiltonian Monte Carlo method explores the target distribution rapidly. Driven by the idea of Hamiltonian dynamics, this sampler provides a non-random walk through the target distribution. The incorporation of subset simulation and Hamiltonian Monte Carlo methods has shown promising results for reliability analysis. One downside of the Hamiltonian Monte Carlo method is that gradient evaluations are computationally expensive, especially when dealing with high-dimensional problems and evaluating long trajectories. We show that integrating Hamiltonian neural networks in Hamiltonian Monte Carlo simulations significantly speeds up the sampling task. Furthermore, the enhancement of adaptive trajectory length within the Hamiltonian Monte Carlo results in the efficient proposal of the following states. Based on this recent enhancement, we provide a fast sampling strategy for subset simulations using Hamiltonian neural networks to replace the evaluation of the gradient and significantly speed up the Hamiltonian Monte Carlo simulation.

97 MATHEMATICS AND COMPUTING↗

Statistical Modeling of CTV Motion and Deformation for IMRT of Early-Stage Rectal Cancer

Purpose: To derive and validate a statistical model of motion and deformation for the clinical target volume (CTV) of early-stage rectal cancer patients. Methods and Materials: For 16 patients, 4 to 5 magnetic resonance images (MRI) were acquired before each fraction was administered. The CTV was delineated on each MRI. Using a leave-one-out methodology, we constructed a population-based principal component analysis (PCA) model of the CTV motion and deformation of 15 patients, and we tested the model on the left-out patient. The modeling error was calculated as the amount of the CTV motion-deformation of the left-out-patient that could not be explained by the PCA model. Next, the PCA model was used to construct a PCA target volume (PCA-TV) by accumulating motion-deformations simulated by the model. A PCA planning target volume (PTV) was generated by expanding the PCA-TV by uniform margins. The PCA-PTV was compared with uniform and nonuniform CTV-to-PTV margins. To allow comparison, geometric margins were determined to ensure adequate coverage, and the volume difference between the PTV and the daily CTV (CTV-to-PTV volume) was calculated. Results: The modeling error ranged from 0.9 ± 0.5 to 2.9 ± 2.1 mm, corresponding to a reduction of the CTV motion-deformation between 6% and 60% (average, 23% ± 11%). The reduction correlated with the magnitude of the CTV motion-deformation (P<.001, R=0.66). The PCA-TV and the CTV required 2-mm and 7-mm uniform margins, respectively. The nonuniform CTV-to-PTV margins were 4 mm in the left, right, inferior, superior, and posterior directions and 8 mm in the anterior direction. Compared to uniform and nonuniform CTV-to-PTV margins, the PCA-based PTV significantly decreased (P<.001) the average CTV-to-PTV volume by 128 ± 20 mL (49% ± 4%) and by 35 ± 6 mL (20% ± 3.5%), respectively. Conclusions: The CTV motion-deformation of a new patient can be explained by a population-based PCA model. A PCA model-generated PTV significantly improved sparing of organs at risk compared to uniform and nonuniform CTV-to-PTV margins.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Full Simulation of CMS for Run-3 and Phase-2

In this contribution we report the status of the CMS Geant4 simulation and the prospects for Run-3 and Phase-2. Firstly, we report about our experience during the start of Run-3 with Geant4 10.7.2, the common software package DD4hep for geometry description, and VecGeom runtime geometry library. In addition, FTFP_BERT_EMM Physics List and CMS configuration for tracking in magnetic field have been utilized. For the first time, for the Grid mass production of Monte-Carlo, this combination of components is used. Further simulation improvements are under development targeting Run-3 such as the switch to the new Geant4 11.1 in production, that provides several features important for the optimization of simulation, for example the new transportation process with built-in multiple scattering, neutron general process, custom tracking manager, G4HepEm sub-library, and others. We will present evaluation of various options, validation results, and the final choice of simulation configuration for 2023 production and beyond. The performance of the CMS full simulation for Run-2 and Run-3 will also be discussed. CMS development plan for the Phase-2 Geant4 based simulation is very ambitious, and it includes a new geometry description, physics, and simulation configurations. The progress on new detector descriptions and full simulation will be presented as well as the R&D in progress to reduce compute capacity needs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of an autonomous video rendezous and docking system

Video control systems using three flashing lights and two other types of docking aids were evaluated through computer simulation and other approaches. The three light system performed much better than the others. Its accuracy is affected little by tumbling of the target spacecraft, and in the simulations it was able to cope with attitude rates up to 20,000 degrees per hour about the docking axis. Its performance with rotation about other axes is determined primarily by the state estimation and goal setting portions of the control system, not by measurement accuracy. A suitable control system, and a computer program that can serve as the basis for the physical simulation are discussed.

Tietz, J. C.↗

Electromagnetic Pulses at Short-Pulse Laser Facilities

Electromagnetic Pulse (EMP) is a known issue for short-pulse laser facilities, and will also be an issue for experiments using the advanced radiographic capability (ARC) at the National Ignition Facility (NIF). The ARC diagnostic uses four NIF beams that are compressed to picosecond durations for backlighting ignition capsules and other applications. Consequently, we are working to understand the EMP due to high-energy (MeV) electrons escaping from targets heated by short-pulse lasers. Our approach is to measure EMP in the Titan short-pulse laser at Lawrence Livermore National Laboratory (LLNL) and to employ that data to establish analysis and simulation capabilities. We have installed a wide variety of probes inside and outside the Titan laser chamber. We have high-frequency B-dot and D-dot probes, a photodiode, and fast current-viewing and integrating current transformers. The probe outputs are digitized by 10 and 20 Gsample/s oscilloscopes. The cables and oscilloscopes are well shielded to reduce noise. Our initial measurement campaign has yielded data useful mainly from several hundreds of MHz to several GHz. We currently are supplementing our high-frequency probes with lower-frequency ones to obtain better low-frequency data. In order to establish analysis and simulation capabilities we are modeling the Titan facility using various commercial and LLNL numerical electromagnetics codes. We have simulated EMP generation by having a specified number of electrons leave the target and strike the chamber wall and other components in the chamber. This short impulse of electrons has a correspondingly broad spectrum, exciting high-frequency structure in the resulting EMP. In this paper, we present results of our initial measurement campaign and comparisons between the measurements and simulations.

36 MATERIALS SCIENCE↗

Acquisition, preprocessing, and reconstruction of ultralow dose volumetric CT scout for organ-based CT scan planning

Purpose: Traditionally, 2D radiographic preparatory scan images (scout scans) are used to plan diagnostic CT scans. However, a 3D CT volume with a full 3D organ segmentation map could provide superior information for customized scan planning and other purposes. A practical challenge is to design the volumetric scout acquisition and processing steps to provide good image quality (at least good enough to enable 3D organ segmentation) while delivering a radiation dose similar to that of the conventional 2D scout. Methods: The authors explored various acquisition methods, scan parameters, postprocessing methods, and reconstruction methods through simulation and cadaver data studies to achieve an ultralow dose 3D scout while simultaneously reducing the noise and maintaining the edge strength around the target organ. Results: In a simulation study, the 3D scout with the proposed acquisition, preprocessing, and reconstruction strategy provided a similar level of organ segmentation capability as a traditional 240 mAs diagnostic scan, based on noise and normalized edge strength metrics. At the same time, the proposed approach delivers only 1.25% of the dose of a traditional scan. In a cadaver study, the authors’ pictorial-structures based organ localization algorithm successfully located the major abdominal-thoracic organs from the ultralow dose 3D scout obtained with the proposed strategy. Conclusions: The authors demonstrated that images with a similar degree of segmentation capability (interpretability) as conventional dose CT scans can be achieved with an ultralow dose 3D scout acquisition and suitable postprocessing. Furthermore, the authors applied these techniques to real cadaver CT scans with a CTDI dose level of less than 0.1 mGy and successfully generated a 3D organ localization map.

60 APPLIED LIFE SCIENCES↗

A detailed examination of laser-ion acceleration mechanisms in the relativistic transparency regime using tracers

Here we present a particle-in-cell study of linearly polarized laser-ion acceleration systems, in which we use both two-dimensional (2D) and three-dimensional (3D) simulations to characterize the ion acceleration mechanisms in targets which become transparent to the laser pulse during irradiation. First, we perform a target length scan to optimize the peak ion energies in both 2D and 3D, and the predictive capabilities of 2D simulations are discussed. Tracer analysis allows us to isolate the acceleration into stages of target normal sheath acceleration (TNSA), hole boring (HB), and break-out afterburner (BOA) acceleration, which vary in effectiveness based on the simulation parameters. The thinnest targets reveal that enhanced TNSA is responsible for accelerating the most energetic ions, whereas the thickest targets have ions undergoing successive phases of HB and TNSA (in 2D) or BOA and TNSA (in 3D); HB is not observed to be a dominant acceleration mechanism in the 3D simulations. It is in the intermediate optimal regime, both when the laser breaks through the target with appreciable amplitude and when there is enough plasma to form a sustained high density flow, that BOA is most effective and is responsible for the most energetic ions. Eliminating the transverse laser spot size effects by performing a plane wave simulation, we can isolate with greater confidence the underlying physics behind the ion dynamics we observe. Specifically, supplemented by wavelet and FFT analyses, we match the post-transparency BOA acceleration with a wave-particle resonance with a high-amplitude low-frequency electrostatic wave of increasing phase velocity, consistent with that predicted by the Buneman instability.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Effects of target charging and ion emission on the energy spectrum of emitted electrons

We present numerical simulations of the energy spectrum of electrons escaping from a target struck by an ultra-intense laser pulse using 2D implicit hybrid particle in cell code LSP (large scale plasma) [D. R. Welch et al., Phys. Plasmas 13, 063105 (2006)] and simple 1D capacitor model. The simulated energy spectrum as recorded by an electron spectrometer is found to differ significantly from the spectrum computed within the target. Analysis of the LSP simulations suggests two major mechanisms are responsible for this phenomenon: (1) The emitted electron energy spectrum is heavily influenced by the self-consistent electric fields generated along the target surface as the electrons escape and (2) these fields are themselves substantially modified by the simultaneous departure of accelerated surface ions. For electrons with internal energy greater than 4 MeV, both models predict a good correlation between the slope temperature of the input electron spectrum and that measured in a vacuum. We discuss the application of the inversion problem of obtaining internal electron energy distributions from experimental data.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Automatic CT simulation optimization for radiation therapy: A general strategy

Purpose: In radiation therapy, x-ray computed tomography (CT) simulation protocol specifications should be driven by the treatment planning requirements in lieu of duplicating diagnostic CT screening protocols. The purpose of this study was to develop a general strategy that allows for automatically, prospectively, and objectively determining the optimal patient-specific CT simulation protocols based on radiation-therapy goals, namely, maintenance of contouring quality and integrity while minimizing patient CT simulation dose. Methods: The authors proposed a general prediction strategy that provides automatic optimal CT simulation protocol selection as a function of patient size and treatment planning task. The optimal protocol is the one that delivers the minimum dose required to provide a CT simulation scan that yields accurate contours. Accurate treatment plans depend on accurate contours in order to conform the dose to actual tumor and normal organ positions. An image quality index, defined to characterize how simulation scan quality affects contour delineation, was developed and used to benchmark the contouring accuracy and treatment plan quality within the predication strategy. A clinical workflow was developed to select the optimal CT simulation protocols incorporating patient size, target delineation, and radiation dose efficiency. An experimental study using an anthropomorphic pelvis phantom with added-bolus layers was used to demonstrate how the proposed prediction strategy could be implemented and how the optimal CT simulation protocols could be selected for prostate cancer patients based on patient size and treatment planning task. Clinical IMRT prostate treatment plans for seven CT scans with varied image quality indices were separately optimized and compared to verify the trace of target and organ dosimetry coverage. Results: Based on the phantom study, the optimal image quality index for accurate manual prostate contouring was 4.4. The optimal tube potentials for patient sizes of 38, 43, 48, 53, and 58 cm were 120, 140, 140, 140, and 140 kVp, respectively, and the corresponding minimum CTDIvol for achieving the optimal image quality index 4.4 were 9.8, 32.2, 100.9, 241.4, and 274.1 mGy, respectively. For patients with lateral sizes of 43–58 cm, 120-kVp scan protocols yielded up to 165% greater radiation dose relative to 140-kVp protocols, and 140-kVp protocols always yielded a greater image quality index compared to the same dose-level 120-kVp protocols. The trace of target and organ dosimetry coverage and the γ passing rates of seven IMRT dose distribution pairs indicated the feasibility of the proposed image quality index for the predication strategy. Conclusions: A general strategy to predict the optimal CT simulation protocols in a flexible and quantitative way was developed that takes into account patient size, treatment planning task, and radiation dose. The experimental study indicated that the optimal CT simulation protocol and the corresponding radiation dose varied significantly for different patient sizes, contouring accuracy, and radiation treatment planning tasks.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

High quality ion acceleration from a double-layer target dominated by the radiation pressure of a transversely Gaussian laser pulse

The ion acceleration from a double-layer target irradiated by a transversely Gaussian laser pulse is investigated by theoretical analysis and particle-in-cell simulations. The main idea of the double-layer target is to match the transverse areal mass density of the target with the laser intensity profile by single ion specie with two densities or by two ion species. Two-dimensional particle-in-cell simulations show that the target deformation and the transverse instability are efficiently suppressed in the double-layer scheme, ions within the laser spot are uniformly accelerated and are well collimated in the forward direction, GeV/u monoenergetic ion beams with very low divergency are observed.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Exploring drift effects in TCV single-null plasmas with the UEDGE code

This study explores the effects of particle drifts across the magnetic field in TCV single-null plasmas using the two-dimensional edge plasma transport code UEDGE. In particular, it aims to reproduce a double-peaked density target profile, a feature which has been observed both at JET and in a TCV forward-field (${\rm{\nabla }}B$ drift of core ions towards the X-point) discharge. Initial simulations are performed with drift effects turned off. This allows identification of the input parameters that strongly influence the computed steady-state but are not well known from the experiment. Including cross-field drifts self-consistently in the simulations brings computed profiles at the inner target closer to the experiment, with the double peak being reproduced for the density. In agreement with the experiment, simulations of a similar reversed-field shot yield lower n e and higher T e at the inner target, as well as unchanged temperatures at the outer plate. However, several discrepancies remain. In the forward field case, the inner target density peak near the separatrix is much sharper than seen experimentally. Furthermore, simulations show a strong dependence of the outer plate density and of the outer/inner power sharing on toroidal field direction. Experimentally, no such dependencies are observed. In the simulations, the changes of target profiles with field direction are mainly due to E × B drifts in the divertor region. Finally, while these simulations highlight the importance of E × B drifts in these TCV plasmas, the remaining differences with the experiment indicate that their role is overestimated in the simulations.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Maturation of biomass‐to‐biofuels conversion technology pathways for rapid expansion of biofuels production: a system dynamics perspective

Abstract The Biomass Scenario Model ( BSM ) is a system‐dynamics simulation model intended to explore the potential for rapid expansion of the biofuels industry. The model is not predictive — it uses scenario assumptions based on various types of data to simulate industry development, emphasizing how incentives and technological learning‐by‐doing might accelerate industry growth. The BSM simulates major sectors of the biofuels industry, including feedstock production and logistics, conversion, distribution, and end uses, as well as interactions among sectors. The model represents conversion of biomass to biofuels as a set of technology pathways, each of which has allowable feedstocks, capital and operating costs, allowable products, and other defined characteristics. This study and the BSM address bioenergy modeling analytic needs that were identified in recent literature reviews. Simulations indicate that investments are most effective at expanding biofuels production through learning‐by‐doing when they are coordinated with respect to timing, pathway, and target sector within the biofuels industry. Effectiveness metrics include timing and magnitude of increased production, incentive cost and cost effectiveness, and avoidance of windfall profits. Investment costs and optimal investment targets have inherent risks and uncertainties, such as the relative value of investment in more‐mature versus less mature pathways. These can be explored through scenarios, but cannot be precisely predicted. Dynamic competition, including competition for cellulosic feedstocks and ethanol market shares, intensifies during times of rapid growth. Ethanol production increases rapidly, even up to Renewable Fuel Standards‐targeted volumes of biofuel, in simulations that allow higher blending proportions of ethanol in gasoline‐fueled vehicles. Published 2014. This article is a U.S. Government work and is in the public domain in the USA. Biofuels, Bioproducts, Biorefining published by John Wiley & Sons, Ltd on behalf of Society of Chemical Industry.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Electron heat conduction under non-Maxwellian distribution in hohlraum simulation

An electron transport model based on the non-Maxwellian distribution f{sub 0}{proportional_to}e{sup -{nu}{sup m}} (NM model), caused by the inverse bremsstrahlung heating, is used in 1-D plane target and 2-D hohlraum simulations. In the NM model, the electron heat flux depends not only on the gradient of electron temperature T{sub e} but also on the gradients of electron number density and the index m. From 1-D simulations, the spatial distribution of T{sub e} is dune-like and T{sub e} decreases obviously in the flux-heated region, which is very different from the flat profile obtained by using the flux limit model (FL model) but similar to the experimental observations [Gregori et al., Phys. Rev. Lett. 92, 205006 (2004)] and the nonlocal results [Rosen et al., High Energy Density Phys. 7, 180 (2011)]. The reason which causes the dune-like profile of T{sub e} is discussed in the paper. From 2-D hohlraum simulations, the NM results of the plasma status, the emission peak and profile inside hohlraum are very different from the FL model results. Finally, it is hard to use an average flux limiter in the FL model to obtain the same hohlraum plasma status and emission with those under the NM model.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Flight and Stability of a Laser Inertial Fusion Energy Target in the Drift Region between Injection and the Reaction Chamber with Computational Fluid Dynamics

A Laser Inertial Fusion Energy (LIFE) target’s flight through a low Reynolds number and high Mach number regime was analyzed with computational fluid dynamics software. This regime consisted of xenon gas at 1,050 K and approximately 6,670 Pa. Simulations with similar flow conditions were performed with a sphere and compared with experimental data and published correlations for validation purposes. Transient considerations of the developing flow around the target were explored. Simulations of the target at different velocities were used to determine correlations for the drag coefficient and Nusselt number as functions of the Reynolds number. Simulations with different angles of attack were used to determine the aerodynamic coefficients of drag, lift, Magnus moment, and overturning moment as well as target stability. The drag force, lift force, and overturning moment changed minimally with spin. Above an angle of attack of 15°, the overturning moment would be destabilizing. At low angles of attack (less than 15°), the overturning moment would tend to decrease the target’s angle of attack, indicating the lack of a need for spin for stability at small angles. This stabilizing moment would cause the target to move in a mildly damped oscillation about the axis parallel to the free-stream velocity vector through the target’s center of gravity.

42 ENGINEERING↗

Resonant scattering experiments with radioactive nuclear beams - Recent results and future plans

Resonant scattering with low-energy radioactive nuclear beams of E < 5 MeV/u have been studied at CRIB of CNS and at RIPS of RIKEN. As an extension to the present experimental technique, we will install an advanced polarized proton target for resonant scattering experiments. A Monte-Carlo simulation was performed to study the feasibility of future experiments with the polarized target. In the Monte-Carlo simulation, excitation functions and analyzing powers were calculated using a newly developed R-matrix calculation code. A project of a small-scale radioactive beam facility at Kyushu University is also briefly described.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Efficient GeV ion generation by ultraintense circularly polarized laser pulse

The interaction of an ultraintense circularly polarized laser pulse and a solid target is studied by one-dimensional particle-in-cell simulations. Ions at the front of the target are reflected by a moving quasisteady electrostatic field and obtain a relativistic velocity. At a laser intensity of 10{sup 22} W/cm{sup 2}, almost half of the laser energy is transferred to ions and GeV ions are obtained. Effects of laser polarization state and target thickness on the laser energy conversion are investigated. It is found that a circularly polarized laser pulse can accelerate ions more efficiently than a linearly polarized laser pulse at the same laser and target parameters. A monoenergetic ion bunch is obtained for the ultrathin target, which is accelerated as a single entity.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A Machine Learning-Genetic Algorithm (ML-GA) Approach for Rapid Optimization Using High-Performance Computing

A Machine Learning-Genetic Algorithm (ML-GA) approach was developed to virtually discover optimum designs using training data generated from multi-dimensional simulations. Machine learning (ML) presents a pathway to transform complex physical processes that occur in a combustion engine into compact informational processes. In the present work, a total of over 2000 sector-mesh computational fluid dynamics (CFD) simulations of a heavy-duty engine were performed. These were run concurrently on a supercomputer to reduce overall turnaround time. The engine being optimized was run on a low-octane (RON70) gasoline fuel under partially premixed compression ignition (PPCI) mode. A total of nine input parameters were varied, and the CFD simulation cases were generated by randomly sampling points from this nine-dimensional input space. These input parameters included fuel injection strategy, injector design, and various in-cylinder flow and thermodynamic conditions at intake valve closure (IVC). The outputs (targets) of interest from these simulations included five metrics related to engine performance and emissions. Over 2000 samples generated from CFD were then used to train an ML model that could predict these five targets based on the nine input features. A robust super learner approach was employed to build the ML model, where results from a collection of different ML algorithms were pooled together. Thereafter, a stochastic global optimization genetic algorithm (GA) was used, with the ML model as the objective function, to optimize the input parameters based on a merit function so as to minimize fuel consumption while satisfying CO and NOx emissions constraints. The optimized configuration from ML-GA was found to be very close to that obtained from a sequentially performed CFD-GA approach, where a CFD simulation served as the objective function. In addition, the overall turnaround time was (at least) 75% lower with the ML-GA approach, as the training data was generated from concurrent CFD simulations and employing the ML model as the objective function significantly accelerated the GA optimization. Finally, this study demonstrates the potential of ML-GA and high-performance computing (HPC) to reduce the number of CFD simulations to be performed for optimization problems without loss in accuracy, thereby providing significant cost savings compared to traditional approaches.

97 MATHEMATICS AND COMPUTING↗