At least 865 records · Page 48

Cryogenic energy storage: Standalone design, rigorous optimization and techno-economic analysis

Energy storage allows flexible use and management of excess electricity and intermittently available renewable energy. Cryogenic energy storage (CES) is a promising storage alternative with a high technology readiness level and maturity, but the round-trip efficiency is often moderate and the Levelized Cost of Storage (LCOS) remains high. The complex flowsheets with intricate thermodynamics at cryogenic temperatures as well as the presence of multiple loops and refrigeration cycles pose considerable challenges for rigorous model-based design and optimization of CES systems. We present an optimization strategy that couples rigorous process simulation and Bayesian optimization with flowsheet decomposition and identification of hidden coupling constraints to optimally design standalone CES systems. Further refinement is done via a local search using the limited-memory Broyden–Fletcher–Goldfarb–Shanno algorithm. Here our results indicate that it is possible to achieve more than 52% round-trip efficiency and an LCOS of $153/MWh for a standalone 100 MW/400 MWh CES system limited to short-term storage with daily charging–discharging. However, a detailed techno-economic assessment reveals that the LCOS considering total capital investment may exceed $267/MWh when all direct and indirect costs of installation and operation are considered.

25 ENERGY STORAGE↗

Forward production of charged pions with incident protons on nuclear targets at the CERN Proton Synchrotron

Measurements of the double-differential {pi}{sup {+-}} production cross section in the range of momentum 0.5{<=}p{<=}8.0 GeV/c and angle 0.025{<=}{theta}{<=}0.25 rad in collisions of protons on beryllium, carbon, nitrogen, oxygen, aluminum, copper, tin, tantalum, and lead are presented. The data were taken with the large-acceptance HAdRon Production (HARP) detector in the T9 beamline of the CERN Proton Synchrotron. Incident particles were identified by an elaborate system of beam detectors. Thin targets of 5% of a nuclear interaction length were used. The tracking and identification of the produced particles were performed using the forward system of the HARP experiment. Results are obtained for the double-differential cross sections d{sup 2}{sigma}/dp d{omega} mainly at four incident proton beam momenta (3, 5, 8, and 12 GeV/c). Measurements are compared with the GEANT4 and MARS Monte Carlo generators. A global parametrization is provided as an approximation of all the collected datasets, which can serve as a tool for quick yield estimates.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Extraction and Visualization of Power System Interarea Oscillatory Modes

Interarea oscillatory modes pose a threat to power system stability. An algorithm is presented for the identification and analysis of such modes from high resolution phasor measurement data. The entire process is outlined including data collection, conditioning, extraction of the primary oscillatory frequency, and determination of participating areas of the system. Additionally a visualization methodology is presented which displays these results. Using the tools developed here the dominant modes and their associated regions of influence in a power system can be determined directly from measurement data.

24 POWER TRANSMISSION AND DISTRIBUTION↗

BioCat 2.0

The U.S. Department of Homeland Security (DHS) National Biosurveillance Integration Center (NBIC) was established in 2008 with a primary mission to “(1) enhance the capability of the Federal Government to (A) rapidly identify, characterize, localize, and track a biological event of national concern by integrating and analyzing data relating to human health, animal, plant, food, and environmental monitoring systems (both national and international); and (B) disseminate alerts and other information to Member Agencies and, in coordination with (and where possible through) Member Agencies, to agencies of State, local, and tribal governments, as appropriate, to enhance the ability of such agencies to respond to a biological event of national concern; and (2) oversee development and operation of the National Biosurveillance Integration System (NBIS).” Inherent in its mission then and the broader NBIS, NBIC is concerned with the identification, understanding, and use of a variety of biosurveillance models and systems. The goal of this project is to characterize, evaluate, classify, and catalog existing disease forecast and prediction models that could provide operational decision support for recognizing a biological event having a potentially significant impact. Additionally, gaps should be identified and recommendations made on using disease models in an operational environment to support real-time decision making.

biosurveillance↗

Two-frequency RF fields induced multipactor in coaxial transmission lines

This study presents a comprehensive investigation of two-surface multipactor discharge in coaxial transmission lines under two-frequency radio frequency (RF) excitation using one-dimensional Monte Carlo simulations validated against three-dimensional particle-in-cell simulations and experimental data. The results show that introducing a second carrier mode can suppress multipactor by reshaping and shrinking the susceptibility region, with the extent and location of suppression strongly dependent on the device's aspect ratio and the relative phase of the second carrier mode. Distinct suppression patterns are observed across different fd regimes, while in some cases, susceptibility expansion also occurs under two-frequency operation. A key outcome is the identification and delineation of pure and mixed multipactor modes in coaxial geometry, where analytical mode boundaries are not readily available. Unlike planar geometries, pure-mode regions in coaxial systems overlap with mixed-mode domains, complicating mode identification. Additionally, image charge forces are found to have negligible influence on susceptibility thresholds but strongly affect electron growth rates. These findings offer valuable insights into the use of waveform engineering for controlling multipactor in high-power RF systems.

43 PARTICLE ACCELERATORS↗

XMM-NEWTON AND FUSE TENTATIVE EVIDENCE FOR A WHIM FILAMENT ALONG THE LINE OF SIGHT TO PKS 0558-504

We present a possible O VIII X-ray absorption line at z = 0.117 {+-} 0.001 which, if confirmed, will be the first one associated with a broad H I Ly{beta} (BLB: FWHM = 160{sup +50} {sub -30} km s{sup -1}) absorber. The absorber lies along the line of sight to the nearby (z = 0.1372) Seyfert 1 galaxy PKS 0558-504, consistent with being a WHIM filament. The X-ray absorber is marginally detected in two independent XMM-Newton spectra of PKS 0558-504, a long {approx}600 ks guest-observer observation and a shorter, {approx}300 ks total, calibration observation, with a combined single line statistical significance of 2.8{sigma} (2.7{sigma} and 1.2{sigma} in the two spectra, respectively). When fitted with our self-consistent hybrid-photoionization WHIM models, the combined XMM- Newton spectrum is consistent with the presence of O VIII K{alpha} at z = (0.117 {+-} 0.001). This model gives best-fitting temperature and equivalent H column density of the absorber of log T = 6.56{sup +0.19} {sub -0.17} K, and log N{sub H} = (21.5 {+-} 0.3)(Z/Z {sub 0.01sun}){sup -1} cm{sup -2}, and predicts the marginal contribution of only two more lines within the XMM- Newton Reflection Grating Spectrometer band pass, Ne IX K{alpha} ({lambda} = 13.45 A) and Fe XVII L ({lambda} = 15.02 A), both with equivalent widths well within the 1{sigma} sensitivity of the combined XMM-Newton spectrum of PKS 0558-504 (EW{sup 1}{sigma} < 3 mA). The lack of detection of associated O VI in the archival FUSE spectrum of PKS 0558-504 allows us to infer a tighter lower limit on the temperature, of log T>6.52 K (at 1{sigma}). The statistical significance of this single X-ray detection is increased by the detection of BLB and complex H I Ly{beta} absorption in archival FUSE spectra of PKS 0558-504, at redshifts z = 0.1183 {+-} 0.0001 consistent with the best-fitting redshift of the X-ray absorber. The FUSE spectrum shows a broad (FWHM = 160{sup +50} {sub -30} km s{sup -1}) absorption complex, which we identify as H I Ly{beta} z {sub BLB} = (0.1183 {+-} 0.0001). The single line statistical significance of this line is 4.1{sigma} (3.7{sigma} if systematics are considered). A possible H I Ly{alpha} is marginally hinted in an archival low-resolution ({Delta}{lambda} {approx} 6 A) International Ultraviolet Explorer (IUE) spectrum of PKS 0558-504, at a redshift of z = (0.119 {+-} 0.001) and with single line significance of 1.7{sigma}. Thus, the combined significance of the three (XMM- Newton, FUSE, and IUE) independent tentative detections, is 5.2{sigma} (5.0{sigma} if the H I Ly{alpha} is not considered, and 4.6{sigma} if the systematics in FUSE are considered). The detection of both metal and H lines at a consistent redshift, in this hot absorbing system, allows us to speculate on its metallicity. By associating the bulk of the X-ray absorber with the BLB line detected in the FUSE spectrum at z {sub BLB} = 0.1183 {+-} 0.0001, we obtain a metallicity of 1%-4% Solar. Although the absorber is only blueshifted by {approx}-6000 km s{sup -1} from the systemic redshift of PKS 0558-504, the identification of the absorbing gas with a high velocity nuclear ionized outflow, is unlikely. The physical, chemical, and dynamical properties of the detected absorber are all quite different from those typically found in the warm absorber (WA) outflows, commonly detected in Seyferts and higher luminosity quasars. WA outflow velocities typically span a range of few hundreds to {approx}1-2 thousands km s{sup -1}; WA metallicities, when measured, are typically found to be at least Solar; high-ionization WAs are virtually always found to coexist with lower-ionization X-ray and UV phases. All this strongly suggests that the absorber, if confirmed, is an intervening WHIM system.

79 ASTRONOMY AND ASTROPHYSICS↗

Process Interactions Can Change Process Ranking in a Coupled Complex System Under Process Model and Parametric Uncertainty

For a complex hydrologic system with multiple processes and process interactions, global sensitivity analysis is often used to identify important or influential parameters for model development and improvement. The identification is complicated by process model uncertainty, when a system process can be represented by multiple process models. This study develops a new total-effect process sensitivity index to identify influential processes under model uncertainty. This is done by extending Sobol's total-effect parameter sensitivity index for one system model to total-effect process sensitivity index for multiple system models to account for uncertainty in process models and model parameters. The total-effect process sensitivity index includes not only the first-order process sensitivity index for measuring the importance of individual processes but also higher-order indices that account for process interactions. The total-effect process sensitivity index can identify an influential process that itself and its interactions with other processes influence a model output. Here, the total-effect process sensitivity index is applied to two numerical examples: (a) Sobol's G*-functions with analytical solutions of first-order and total-effect process sensitivity indices, and (b) groundwater flow models with interactions between recharge, geology, and snowmelt processes. The second evaluation shows that, due to second-order and higher-order process interactions, the first-order and total-effect process sensitivity indices give different process ranking. It is thus necessary to estimate both first-order and total-effect process sensitivity indices to appreciate the difference between the first-order impact of a process alone and the overall total-effect impact of the process itself and its interactions with other processes on a model output.

54 ENVIRONMENTAL SCIENCES↗

Verification of source and collimator configuration for Gamma Knife Perfexion using panoramic imaging

Purpose: The new model of stereotactic radiosurgery system, Gamma Knife Perfexion, allows automatic selection of built-in collimation, eliminating the need for the time consuming manual collimator installation required with previous models. However, the configuration of sources and collimators inside the system does not permit easy access for the verification of the selected collimation. While the conventional method of exposing a film at the isocenter is useful for obtaining composite dose information, it is difficult to interpret the data in terms of the integrity of each individual source and corresponding collimation. The primary aim of this study was to develop a method of verifying the geometric configuration of the sources and collimator modules of the Gamma Knife Perfexion. In addition, the method was extended to make dose measurements and verify the accuracy of dose distributions calculated by the mathematical formalism used in the treatment planning system, Leksell Gamma Plan. Methods: A panoramic view of all of 192 cobalt sources was simultaneously acquired by exposing a radiochromic film wrapped around the surface of a cylindrical phantom. The center of the phantom was mounted at the isocenter with its axis aligned along the longitudinal axis of the couch. The sizes and shapes of the source images projected on the phantom surface were compared to those calculated based on the manufacturer's design specifications. The measured dose at various points on the film was also compared to calculations using the algorithm of the planning system. Results: The panoramic images allowed clear identification of each of the 192 sources, verifying source integrity and selected collimator sizes. Dose on the film surface is due to the primary beam as well as phantom scatter and leakage contributions. Therefore, the dose at a point away from the isocenter cannot be determined simply based on the proportionality of collimator output factors; the use of a dose computation algorithm is required. Scatter and leakage dose contributions from neighboring sources were calculated and found to be 6.3% (ranging from 4.5% to 7.4%), 16.7% (12.5%-19.3%), and 66.6% (38%-78%) for the 4, 8, and 16 mm collimators, respectively, at the centers of the source images. The measured average dose on films with 16 mm collimators agrees with the dose model of the treatment planning system to within 1.0%. The average doses on the film were 24.0, 60.8, and 186.2 cGy for 4, 8, and 16 mm diameter collimators, respectively, when the machine was set to deliver a reference dose of 100 Gy to the center of an 80 mm radius spherical dosimetry phantom. Conclusions: A method of simultaneously capturing and analyzing the panoramic images of 192 cobalt sources has been developed to verify the source and collimator configuration of GK systems. The method was extended to verify the dose calculation model of the treatment planning system by comparing the measured doses on the panoramic film images and the corresponding calculated doses. The method presented can play a significant role in comprehensive commissioning and routine quality assurance testing of the Gamma Knife systems.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Networked Gamma Radiation System for Tactical Deployment

A networked gamma radiation detection system with directional sensitivity and energy spectral data acquisition capability is being developed by the National Security Technologies, LLC, Remote Sensing Laboratory to support the close and intense tactical engagement of law enforcement who carry out counterterrorism missions. In the proposed design, three clusters of 2" × 4" × 16" sodium iodide crystals (4 each) with digiBASE-E (for list mode data collection) would be placed on the passenger side of a minivan. To enhance localization and facilitate rapid identification of isotopes, advanced smart real-time localization and radioisotope identification algorithms like WAVRAD (wavelet-assisted variance reduction for anomaly detection) and NSCRAD (nuisance-rejection spectral comparison ratio anomaly detection) will be incorporated. We will test a collection of algorithms and analysis that centers on the problem of radiation detection with a distributed sensor network. We will study the basic characteristics of a radiation sensor network and focus on the trade-offs between false positive alarm rates, true positive alarm rates, and time to detect multiple radiation sources in a large area. Empirical and simulation analyses of critical system parameters, such as number of sensors, sensor placement, and sensor response functions, will be examined. This networked system will provide an integrated radiation detection architecture and framework with (i) a large nationally recognized search database equivalent that would help generate a common operational picture in a major radiological crisis; (ii) a robust reach back connectivity for search data to be evaluated by home teams; and, finally, (iii) a possibility of integrating search data from multi-agency responders.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Progress status for the Mu2e calorimeter system

The Mu2e experiment at FNAL aims to measure the charged-lepton flavor violating neutrinoless conversion of a negative muon into an electron. The conversion results in a monochromatic electron with an energy slightly below the muon rest mass (104.97 MeV). The calorimeter should confirm that the candidates reconstructed by the extremely precise tracker system are indeed conversion electrons while performing a powerful $\mu/e$ particle identification. Moreover, it should also provide a high level trigger for the experiment independently from the tracker system. The calorimeter should also be able to keep functionality in an environment where the background delivers a dose of ~ 10 krad/year in the hottest area and to work in the presence of 1 T axial magnetic field. These requirements translate in the design of a calorimeter with large acceptance, good energy resolution O(5%) and a reasonable position (time) resolution of ~<1 cm (<0.5ns). The baseline version of the calorimeter is composed by two disks of inner (outer) radius of 351 (660) mm filled by 1860 hexagonal $BaF_2$ crystals of 20 cm length. Each crystal is readout by two large area APD's. In this study, we summarize the experimental tests done so far as well as the simulation studies in the Mu2e environment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A NEW ALGORITHM FOR RADIOISOTOPE IDENTIFICATION OF SHIELDED AND MASKED SNM/RDD MATERIALS

Detection and identification of shielded and masked nuclear materials is crucial to national security, but vast borders and high volumes of traffic impose stringent requirements for practical detection systems. Such tools must be be mobile, and hence low power, provide a low false alarm rate, and be sufficiently robust to be operable by non-technical personnel. Currently fielded systems have not achieved all of these requirements simultaneously. Transport modeling such as that done in GADRAS is able to predict observed spectra to a high degree of fidelity; our research is focusing on a radionuclide identification algorithm that inverts this modeling within the constraints imposed by a handheld device. Key components of this work include incorporation of uncertainty as a function of both the background radiation estimate and the hypothesized sources, dimensionality reduction, and nonnegative matrix factorization. We have partially evaluated performance of our algorithm on a third-party data collection made with two different sodium iodide detection devices. Initial results indicate, with caveats, that our algorithm performs as good as or better than the on-board identification algorithms. The system developed was based on a probabilistic approach with an improved approach to variance modeling relative to past work. This system was chosen based on technical innovation and system performance over algorithms developed at two competing research institutions. One key outcome of this probabilistic approach was the development of an intuitive measure of confidence which was indeed useful enough that a classification algorithm was developed based around alarming on high confidence targets. This paper will present and discuss results of this novel approach to accurately identifying shielded or masked radioisotopes with radiation detection systems.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Phases of a Two-Dimensional Bose Gas in an Optical Lattice

Ultracold atoms in optical lattices realize simple condensed matter models. We create an ensemble of {approx_equal}60 harmonically trapped 2D Bose-Hubbard systems from a {sup 87}Rb Bose-Einstein condensate in an optical lattice and use a magnetic resonance imaging approach to select a few 2D systems for study, thereby eliminating ensemble averaging. Our identification of the transition from superfluid to Mott insulator, as a function of both atom density and lattice depth, is in excellent agreement with a universal state diagram [M. Rigol et al., Phys. Rev. A 79 053605 (2009)] suitable for our trapped system. In agreement with theory, our data suggest a failure of the local density approximation in the transition region.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Atmospheric Solids Analysis Probe Mass Spectrometry: A New Approach for Airborne Particle Analysis

Secondary organic aerosols (SOA) formed in the atmosphere from the condensation of semivolatile oxidation products are a significant component of airborne particles which have deleterious effects on health, visibility, and climate. In this study, atmospheric solids analysis probe mass spectrometry (ASAP-MS) is applied for the first time to the identification of organics in particles from laboratory systems as well as from ambient air. SOA were generated in the laboratory from the ozonolysis of r-pinene and isoprene, as well as from NO3 oxidation of r-pinene, and ambient air was sampled at forested and suburban sites. Particles were collected by impaction on ZnSe disks, analyzed by Fourier transform-infrared spectroscopy (FT-IR) and then transferred to an ASAP-MS probe for further analysis. ASAP-MS data for the laboratory-generated samples show peaks from wellknown products of these reactions, and higher molecular weight oligomers are present in both laboratory and ambient samples. Oligomeric products are shown to be present in the NO3 reaction products for the first time. A major advantage of this technique is that minimal sample preparation is required, and complementary information from nondestructive techniques such as FT-IR can be obtained on the same samples. In addition, a dedicated instrument is not required for particle analysis. This work establishes that ASAP-MS will be useful for identification of organic components of SOA in a variety of field and laboratory studies.

Environmental Molecular Sciences Laboratory↗

MCP-PMT development at Argonne for particle identification

The proposed high-energy high-luminosity polarized Electron-Ion Collider (EIC) demands excellent particle identification over a wide range of particles momenta to achieve the best separation between signal and background particles. Various Cherenkov imaging detector sub-systems are being considered in EIC detector concepts for hadron identification for particles momenta up to 50 GeV/c. One important challenge in this case is to provide a reliable highly pixelated photosensor working in the high radiation and high magnetic field environment. The recently commercialized Large Area Picosecond Photo-Detector (LAPPD) provides a promising low-cost photosensor solution for the various EIC Cherenkov imaging sub-systems. Optimization of the phtosensor design for high magnetic field tolerance, precision timing resolution, and pixelated readout was performed at Argonne National Laboratory with 6 x 6 cm(2) microchannel plate photomultipliers. The techniques and optimized design parameters would be transferrable to industrial partners for low-cost LAPPD production to achieve the demonstrated performance.

atomic layer deposition↗

Potentials for J/{psi} from b decays measurement in the ALICE experiment at LHC

The ALICE potentials in proton-proton collisions for the measurement of the fraction of J/{psi} produced at central rapidity (|y|<0.9) in beauty hadrons semi-inclusive decays, namely B{yields}J/{psi}X, is discussed.This measurement relies on the combined use of the Time Projection Chamber (TPC), for tracking and particle identification via dE/dx measurement; the Inner Tracking System (ITS) for tracking and detection of displaced vertices; the Transition Radiation Detector (TRD) for particle identification.The description of the analysis method developed and the discussion of the estimate for a total J/{psi} statistics corresponding to one year of ALICE data taking in p-p collisions at {radical}(s) = 7 TeV is provided in the article.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Imaging gate-tunable Tomonaga–Luttinger liquids in 1H-MoSe 2 mirror twin boundaries

One-dimensional electron systems exhibit fundamentally different properties than higher-dimensional systems. For example, electron-electron interactions in one-dimensional electron systems have been predicted to induce Tomonaga-Luttinger liquid behaviour. Naturally occurring grain boundaries in single-layer transition metal dichalcogenides exhibit one-dimensional conducting channels that have been proposed to host Tomonaga-Luttinger liquids, but charge density wave physics has also been suggested to explain their behaviour. Clear identification of the electronic ground state of this system has been hampered by an inability to electrostatically gate such boundaries and tune their charge carrier concentration. Here we present a scanning tunnelling microscopy and spectroscopy study of gate-tunable mirror twin boundaries in single-layer 1H-MoSe 2 devices. Gating enables scanning tunnelling microscopy and spectroscopy for different mirror twin boundary electron densities, thus allowing precise characterization of electron-electron interaction effects. Visualization of the resulting mirror twin boundary electronic structure allows unambiguous identification of collective density wave excitations having two velocities, in quantitative agreement with the spin-charge separation predicted by finite-length Tomonaga-Luttinger liquid theory.

36 MATERIALS SCIENCE↗

EPRI Demonstration of an Autonomous Site Characterization Vehicle - 20523

A substantial effort is applied in performing radiological characterization of structures and land areas during decommissioning of a nuclear facility. This includes multiple surveys of land areas and large structures to support eventual site release under the Multi Agency Survey and Site Investigation Manual (MARSSIM, Reference 1). These surveys are typically performed using manually delivered systems, which is time consuming and labor intensive. Radiological surveys intentionally follow a prescribed protocol with respect to areas covered, scan speeds, responses to elevated readings, required detector offsets, the need for repeat measurements, etc. Based on these attributes, combined with the repetitive effort of performing surveys over large areas, automation of radiological characterization techniques has a high potential to be successful and promises substantial benefit. EPRI has performed a project that resulted in the development and demonstration of an autonomous site characterization system. This EPRI project focused on building surfaces and the surfaces of large land areas as these configurations lend themselves more readily to automated survey. The project included: - Identification of the requirements for an autonomous site characterization system; - A survey of existing control systems that use automation to conduct characterization of structures and land areas. - As no fully adequate systems were identified, a complete system was developed that utilized commercially available detection and analysis systems and a self driving vehicle owned by EPRI. The system was demonstrated at the Kewaunee nuclear power plant site in the fall of 2019. The demonstration included: - Autonomous surveys of floor areas inside the Auxiliary Building at Kewaunee after manually controlled mapping of the survey areas. - For land areas, the vehicle autonomously surveyed areas using travel paths had been preprogrammed onto an internet available map of area. In this case, GPS coordinates from the preprogramming were used for navigation by the vehicles guidance system. This paper summarizes the characterization system development and system demonstration which will also be published in an EPRI report in the first half of 2020. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗