Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Spectrum Analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

Observation of the decay B s 0 → Φ π + π – and evidence for B 0 → Φ π + π –

The first observation of the rare decay B 0 s →Φπ + π – and evidence for B 0 →Φπ + π – are reported, using pp collision data recorded by the LHCb detector at center-of-mass energies √s = 7 and 8 TeV, corresponding to an integrated luminosity of 3 fb –1 . The branching fractions in the π + π – invariant mass range 400 < m(π + π – ) < 1600 MeV/c 2 are [3.48±0.23±0.17±0.35]×10 –6 and [1.82±0.25±0.41±0.14]×10 –7 for B 0 s →Φπ + π – and B 0 →Φπ + π – respectively, where the uncertainties are statistical, systematic and from the normalization mode B 0 s →ΦΦ. A combined analysis of the π + π – mass spectrum and the decay angles of the final-state particles identifies the exclusive decays B 0 s →Φf 0 (980), B 0 s →Φf 2 (1270), and B 0 s →Φρ 0 with branching fractions of [1.12±0.16+0.09–0.08±0.11]×10 –6 , [0.61±0.13+0.12–0.05±0.06]×10 –6 and [2.7±0.7±0.2±0.2]×10 –7 , respectively.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Transparent conductive Al-doped ZnO thin films grown at room temperature

Aluminum-doped ZnO (ZnO:Al, AZO) thin films were prepared on glass substrates by dc reactive magnetron sputtering from a Zn-Al alloy target at room temperature. The effects of the Ar-to-O{sub 2} partial pressure ratios on the structural, electrical, and optical properties of AZO films were studied in detail. AZO films grown using 100:4 to 100:8 Ar-to-O{sub 2} ratio result in acceptable quality films with c-axis orientated crystals, uniform grains, 10{sup -3} {Omega} cm resistivity, greater than 10{sup 20} cm{sup -3} electron concentration, and high transmittance, 90%, in the visible region. The lowest resistivity of 4.11x10{sup -3} {Omega} cm was obtained under the Ar-to-O{sub 2} partial pressure ratio of 100:4. A relatively strong UV emission at {approx}3.26 eV was observed in the room-temperature photoluminescence spectrum. X-ray photoelectron spectroscopy analysis confirmed that Al was introduced into ZnO and substitutes for Zn and doped the film n-type.

36 MATERIALS SCIENCE↗

Low-temperature dehydration of gypsum single crystals

On the basis of the analysis of the electron spin resonance spectrum of the SO{sub 3}{sup -} radical ion, it is established that the transformation of gypsum (CaSO{sub 4} . 2H{sub 2}O) into bassanite (CaSO{sub 4} . 0.5H{sub 2}O) with partial removal of water molecules occurs through the formation of an anhydrous metastable phase. This phenomenon, reflecting the processes of recrystallization of materials of this class, serves as the scientific basis for the production of binders from sulfate mineral associations.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Shell closures, loosely bound structures, and halos in exotic nuclei

Inspired by the recent experiments indicating doubly magic nuclei that lie near the drip-line and encouraged by the success of our relativistic mean-field (RMF) plus state-dependent BCS approach to the description of the ground-state properties of drip-line nuclei, we develop this approach further, across the entire periodic table, to explore magic nuclei, loosely bound structures, and halo formation in exotic nuclei. In our RMF+BCS approach, the single-particle continuum corresponding to the RMF is replaced by a set of discrete positive-energy states for the calculations of pairing energy. Detailed analysis of the single-particle spectrum, pairing energies, and densities of the nuclei predict the unusual proton shell closures at proton numbers Z = 6, 14, 16, 34, and unusual neutron shell closures at neutron numbers N = 6, 14, 16, 34, 40, 70, 112. Further, in several nuclei like the neutron-rich isotopes of Ca, Zr, Mo, etc., the gradual filling of lowlying single-particle resonant state together with weakly bound single-particle states lying close to the continuum threshold helps accommodate more neutrons but with an extremely small increase in the binding energy. This gives rise to the occurrence of loosely bound systems of neutron-rich nuclei with a large neutron-to-proton ratio. In general, the halo-like formation, irrespective of the existence of any resonant state, is seen to be due to the large spatial extension of the wave functions for the weakly bound single-particle states with low orbital angular momentum having very small or no centrifugal barriers.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Measuring of fissile isotope partial antineutrino spectra in direct experiment at nuclear reactor

The direct measuring method is considered to get nuclear reactor antineutrino spectrum. We suppose to isolate partial spectra of the fissile isotopes by using the method of antineutrino spectrum extraction from the inverse beta-decay reaction positron spectrum applied at Rovno experiment. This admits to increase the accuracy of partial antineutrino spectra forming the total nuclear reactor spectrum. It is important for the analysis of the reactor core fuel composition and could be applied for non-proliferation purposes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Identification of Uranium Minerals in Natural U-Bearing Rocks Using Infrared Reflectance Spectroscopy

The identification of minerals, including uranium-bearing minerals, is traditionally a labor-intensive-process using x-ray diffraction (XRD), fluorescence, or other solid-phase and wet chemical techniques. While handheld XRD and fluorescence instruments can aid in field identification, handheld infrared reflectance spectrometers can also be used in industrial or field environments, with rapid, non-destructive identification possible via spectral analysis of the solid’s reflectance spectrum. We have recently developed standard laboratory measurement methods for the infrared (IR) reflectance of solids and have investigated using these techniques for the identification of uranium-bearing minerals, using XRD methods for ground-truth. Due to the rich colors of such species, including distinctive spectroscopic signatures in the infrared, identification is facile and specific, both for samples that are pure or are partially composed of uranium (e.g. boltwoodite, schoepite, tyuyamunite, carnotite, etc.) or non-uranium minerals. The method can be used to detect not only pure and partial minerals, but is quite sensitive to chemical change such as hydration (e.g. schoepite). We have further applied statistical methods, in particular classical least squares (CLS) and multivariate curve resolution (MCR) for discrimination of such uranium minerals and two uranium pure chemicals (U3O8 and UO2) against common background materials (e.g. silica sand, asphalt, calcite, K-feldspar) with good success. Each mineral contains unique infrared spectral features; some of the IR features are similar or common to entire classes of minerals, typically arising from similar chemical moieties or functional groups in the minerals: phosphates, sulfates, carbonates, etc. These characteristic 2 infrared bands generate the unique (or class-specific) bands that distinguish the mineral from the interferents or backgrounds. We have observed several cases where the chemical moieties that provide the spectral discrimination in the longwave IR do so by generating upward-going reststrahlen bands in the reflectance data, but the same minerals have other weaker (overtone) bands, sometimes from the same chemical groups, that are manifest as downward-going transmission-type features in the midwave and shortwave infrared.

Beiswenger, Toya N.↗

Open Enrollment 2017 (October 31-November 17)

Sandia Total Health plan premiums are increasing between $\$2$ and $\$22$ depending on health plan and tier level. Sandia Total Health will cover Applied Behavioral Analysis (ABA) treatment services for Autism Spectrum Disorder (ASD).

99 GENERAL AND MISCELLANEOUS↗

An atmospheric muon neutrino disappearance measurement with the MINOS far detector

It is now widely accepted that the Standard Model assumption of massless neutrinos is wrong, due primarily to the observation of solar and atmospheric neutrino flavor oscillations by a small number of convincing experiments. The MINOS Far Detector, capable of observing both the outgoing lepton and associated showering products of a neutrino interaction, provides an excellent opportunity to independently search for an oscillation signature in atmospheric neutrinos. To this end, a MINOS data set from an 883 live day, 13.1 kt-yr exposure collected between July, 2003 and April, 2007 has been analyzed. 105 candidate charged current muon neutrino interactions were observed, with 120.5 ± 1.3 (statistical error only) expected in the absence of oscillation. A maximum likelihood analysis of the observed log(L/E) spectrum shows that the null oscillation hypothesis is excluded at over 96% confidence and that the best fit oscillation parameters are sin 2 2θ 23 = 0.95 -0.32 and Δm$2\atop{23}$ = 0.93$+3.94\atop{ -0.44}$ x 10 -3 eV 2 . This measurement of oscillation parameters is consistent with the best fit values from the Super-Kamiokande experiment at 68% confidence.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Ground-state proton decay of 69Br and implications for the rp -process 68Se waiting-point

The first direct measurement of the proton separation energy, S p , for the proton-unbound nucleus 69Br is reported. Of interest is the exponential dependence of the 2 p-capture rate on S p which can bypass the 68Se waiting-point in the astrophysical rp process. An analysis of the observed proton decay spectrum is given in terms of the 69Se mirror nucleus and the influence of S p is explored within the context of a single-zone X-ray burst model.

Rogers, Andrew M.↗

Charge Carrier Diffusion Length Determination in 4H-SiC Schottky Alpha Detectors

When developing semiconductor radiation detectors detailed characterization of the detector behavior is required. The ability of a semiconductor radiation detector to collect the charge liberated by incident ionizing radiation is a critical characteristic. Several factors influence the charge collection efficiency of a semiconductor radiation detector, including electron-hole trapping, applied electric field strength, and dopant concentrations and dimensions of low doped regions. Applying a reverse bias electric potential to a low doped semiconductor region creates a free charge carrier depleted region and establishes an electric field which can remove subsequently freed charge in the form of an electrical signal. When ionizing radiation is incident upon a semiconductor electron-hole pairs are generated. These charge carriers are created along the path of the ionizing radiation regardless of the doping concentration. However, only the charge freed in the low doped epitaxial region of a detector will be collected as a result of the applied electric field. When the electric field is insufficient to develop a depleted region equal to or larger than the range of the ionizing radiation in the detector material some charge freed by the ionizing radiation outside of the sensitive region will be lost, thus potentially resulting in less than complete charge collection. The incomplete collection of charge complicates the analysis of the incident particle energy spectrum. Charge freed in the highly doped bulk region beyond the low doped epitaxial region may diffuse back into the low doped depleted region and be subsequently included in the integral pulse. The amount of charge collected as a result of this diffusion mechanism is dependent upon the diffusion length of the charge carriers in the material. The diffusion length is subsequently dependent on the material properties of the detector including the number of defects, trapping centers, and temperature. In order to fully characterize the properties of 4H-SiC as a radiation detector the diffusion length was calculated by adjusting the theoretical diffusion length value used in the calculation of the charge collection efficiency to agree with empirically observed charge collection efficiencies. The discrepancy between the observed and theoretical charge collection efficiency at 50 to 150 volts applied bias indicates an unexplained charge collection phenomenon which is contributing to the larger than predicted charge collection efficiency of the detectors. This voltage range corresponds to an intermediate applied bias, indicating that either the theoretical depletion width is too short, the diffusion length varies with the composition of the region that the charge carriers are diffusing through, or some other phenomenon is involved. If the charge carrier diffusion length varies depending on whether or not the diffusing charge is freed in unbiased epitaxy or bulk layer, then a function describing the variation of the diffusion layer could be determined by measuring the diffusion length at the applied voltages used previously, but over a range of epitaxial layer thicknesses. Future work includes the characterization of the effects of high temperature operation on the diffusion length of 4H-SiC in addition to measuring the effects of varying energy alpha emitter electrodeposition on the observed diffusion length. Additional Schottky barrier contacts, namely those with a nickel-platinum contact, will be tested in various sizes which have been developed in order to eliminate certain failure mechanisms and explore the potential effects of Schottky contact size on charge collection efficiency. (authors)

36 MATERIALS SCIENCE↗

THE CHEMICAL COMPOSITION OF CERNIS 52 (BD+31{sup 0} 640)

We present an abundance analysis of the star Cernis 52 in whose spectrum we recently reported the naphthalene cation in absorption at 6707.4 A. This star is on a line of sight to the Perseus molecular complex. The analysis of high-resolution spectra using a chi2-minimization procedure and a grid of synthetic spectra provides the stellar parameters and the abundances of O, Mg, Si, S, Ca, and Fe. The stellar parameters of this star are found to be T{sub eff} = 8350 +- 200 K, log(g/cm s{sup 2})=4.2 +- 0.4 dex. We derived a metallicity of [Fe/H] = -0.01 +- 0.15. These stellar parameters are consistent with a star of approx2 M {sub sun} in a pre-main-sequence evolutionary stage. The stellar spectrum is significantly veiled in the spectral range lambdalambda5150-6730 A up to almost 55% of the total flux at 5150 A and decreasing toward longer wavelengths. Using Johnson-Cousins and Two Micron All Sky Survey photometric data, we determine a distance to Cernis 52 of 231{sup +135} {sub -85} pc considering the error bars of the stellar parameters. This determination places the star at a similar distance to the young cluster IC 348. This together with its radial velocity, v{sub r} = 13.7 +- 1 km s{sup -1}, its proper motion and probable young age support Cernis 52 as a likely member of IC 348. We determine a rotational velocity of vsin i = 65 +- 5 km s{sup -1} for this star. We confirm that the stellar resonance line of Li I at 6707.8 A is unable to fit the broad feature at 6707.4 A. This feature should have a interstellar origin and could possibly form in the dark cloud L1470 surrounding all the cluster IC 348 at about the same distance.

79 ASTRONOMY AND ASTROPHYSICS↗

The Uncertainty in the Local Seismic Response Analysis

In the present paper is shown the influence on the local seismic response analysis exerted by considering dispersion and uncertainty in the seismic input as well as in the dynamic properties of soils. In a first attempt a 1D numerical model is developed accounting for both the aleatory nature of the input motion and the stochastic variability of the dynamic properties of soils. The seismic input is introduced in a non-conventional way through a power spectral density, for which an elastic response spectrum, derived--for instance--by a conventional seismic hazard analysis, is required with an appropriate level of reliability. The uncertainty in the geotechnical properties of soils are instead investigated through a well known simulation technique (Monte Carlo method) for the construction of statistical ensembles. The result of a conventional local seismic response analysis given by a deterministic elastic response spectrum is replaced, in our approach, by a set of statistical elastic response spectra, each one characterized by an appropriate level of probability to be reached or exceeded. The analyses have been carried out for a well documented real case-study. Lastly, we anticipate a 2D numerical analysis to investigate also the spatial variability of soil's properties.

58 GEOSCIENCES↗

The spectral theorem for quaternionic unbounded normal operators based on the S-spectrum

In this paper we prove the spectral theorem for quaternionic unbounded normal operators using the notion of S-spectrum. The proof technique consists of first establishing a spectral theorem for quaternionic bounded normal operators and then using a transformation which maps a quaternionic unbounded normal operator to a quaternionic bounded normal operator. With this paper we complete the foundation of spectral analysis of quaternionic operators. The S-spectrum has been introduced to define the quaternionic functional calculus but it turns out to be the correct object also for the spectral theorem for quaternionic normal operators. The lack of a suitable notion of spectrum was a major obstruction to fully understand the spectral theorem for quaternionic normal operators. A prime motivation for studying the spectral theorem for quaternionic unbounded normal operators is given by the subclass of unbounded anti-self adjoint quaternionic operators which play a crucial role in the quaternionic quantum mechanics.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

NuSTAR DETECTION OF HARD X-RAY PHASE LAGS FROM THE ACCRETING PULSAR GS 0834–430

The Nuclear Spectroscopic Telescope Array hard X-ray telescope observed the transient Be/X-ray binary GS 0834–430 during its 2012 outburst—the first active state of this system observed in the past 19 yr. We performed timing and spectral analysis and measured the X-ray spectrum between 3-79 keV with high statistical significance. We find the phase-averaged spectrum to be consistent with that observed in many other magnetized, accreting pulsars. We fail to detect cyclotron resonance scattering features that would allow us to constrain the pulsar's magnetic field in either phase-averaged or phase-resolved spectra. Timing analysis shows a clearly detected pulse period of ∼12.29 s in all energy bands. The pulse profiles show a strong, energy-dependent hard phase lag of up to 0.3 cycles in phase, or about 4 s. Such dramatic energy-dependent lags in the pulse profile have never before been reported in high-mass X-ray binary pulsars. Previously reported lags have been significantly smaller in phase and restricted to low energies (E < 10 keV). We investigate the possible mechanisms that might produce this energy-dependent pulse phase shift. We find the most likely explanation for this effect is a complex beam geometry.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-E-I-62: Assessing Radiation Dose Reduction and CT Image Optimization Through the Measurement and Analysis of the Detector Quantum Efficiency (DQE) of CT Images Using Different Beam Hardening Filters

Purpose: Reducing patient dose while maintaining (or even improving) image quality is one of the foremost goals in CT imaging. To this end, we consider the feasibility of optimizing CT scan protocols in conjunction with the application of different beam-hardening filtrations and assess this augmentation through noise-power spectrum (NPS) and detector quantum efficiency (DQE) analysis. Methods: American College of Radiology (ACR) and Catphan phantoms (The Phantom Laboratory) were scanned with a 64 slice CT scanner when additional filtration of thickness and composition (e.g., copper, nickel, tantalum, titanium, and tungsten) had been applied. A MATLAB-based code was employed to calculate the image of noise NPS. The Catphan Image Owl software suite was then used to compute the modulated transfer function (MTF) responses of the scanner. The DQE for each additional filter, including the inherent filtration, was then computed from these values. Finally, CT dose index (CTDIvol) values were obtained for each applied filtration through the use of a 100 mm pencil ionization chamber and CT dose phantom. Results: NPS, MTF, and DQE values were computed for each applied filtration and compared to the reference case of inherent beam-hardening filtration only. Results showed that the NPS values were reduced between 5 and 12% compared to inherent filtration case. Additionally, CTDIvol values were reduced between 15 and 27% depending on the composition of filtration applied. However, no noticeable changes in image contrast-to-noise ratios were noted. Conclusion: The reduction in the quanta noise section of the NPS profile found in this phantom-based study is encouraging. The reduction in both noise and dose through the application of beam-hardening filters is reflected in our phantom image quality. However, further investigation is needed to ascertain the applicability of this approach to reducing patient dose while maintaining diagnostically acceptable image qualities in a clinical setting.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Impacts of Fast-Spectrum Molten Salt Reactor Characteristics on Fuel Cycle Performance

The System Analysis and Integration Campaign nuclear fuel cycle evaluation and screening study was conducted to outline the potential benefits and challenges of nuclear fuel cycle options. The study identified continuous recycle in fast critical reactors as a common characteristic shared among some of the most promising future nuclear fuel cycles. This study was technology agnostic to focus on the underpinning physics that drives fuel cycle outcomes. This process used an analysis example to generate a physics-based understanding of the fuel cycle, and it yielded performance metrics over ranges rather than comparing absolute numbers. While no fast-spectrum molten salt reactor (MSR) has ever been built, several concepts exist using different fuels and carrier salts, many of which target high-burnup objectives, such as lightwater reactor nuclear waste consumption. Putting the resulting fuel cycle impacts of these reactor choices (e.g., fuel and neutron spectrum) into perspective is informative for our current understanding of a given fuel cycle’s performance, and it also demonstrates the applicability of MSRs to different fuel cycles. It has been established that in a fuel cycle transition, performance of a given fast-spectrum MSR depends in part on the initial fuel loading requirements and processing methods.

Betzler, Benjamin↗

Feasibility study of noise analysis methods on virtual thermal reactor subcriticality monitoring

This paper presents the analysis results of Rossi-alpha, cross-correlation, Feynman-alpha, and Feynman difference methods applied to the subcriticality monitoring of nuclear reactors. A thermal spectrum Godiva model has been designed for the analysis of the four methods. This Godiva geometry consists of a spherical core containing the isotopes of H-l, U-235 and U-238, and the H{sub 2}O reflector outside the core. A Monte Carlo code, McCARD, is used in real time mode to generate virtual detector signals to analyze the feasibility of the four methods. The analysis results indicate that the four methods can be used with high accuracy for the continuous monitoring of subcriticality. In addition to that, in order to analyze the impact of the random noise contamination on the accuracy of the noise analysis, the McCARD-generated signals are contaminated with arbitrary noise. It is noticed that, even when the detector signals are contaminated, the four methods can predict the subcriticality with reasonable accuracy. Nonetheless, in order to reduce the adverse impact of the random noise, eight detector signals, rather than a single signal, are generated from the core, one signal from each equally divided eighth part of the core. The preliminary analysis with multiple virtual detector signals indicates that the approach of using many detectors is promising to improve the accuracy of criticality prediction and further study will be performed in this regard. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

NuSTAR observations of the magnetar 1E 2259+586

We report on new broad band spectral and temporal observations of the magnetar 1E 2259+586, which is located in the supernova remnant CTB 109. Our data were obtained simultaneously with the Nuclear Spectroscopic Telescope Array (NuSTAR) and Swift, and cover the energy range from 0.5-79 keV. We present pulse profiles in various energy bands and compare them to previous RXTE results. The NuSTAR data show pulsations above 20 keV for the first time and we report evidence that one of the pulses in the double-peaked pulse profile shifts position with energy. The pulsed fraction of the magnetar is shown to increase strongly with energy. Our spectral analysis reveals that the soft X-ray spectrum is well characterized by an absorbed double blackbody or blackbody plus power-law model in agreement with previous reports. Our new hard X-ray data, however, suggest that an additional component, such as a power law, is needed to describe the NuSTAR and Swift spectrum. We also fit the data with the recently developed coronal outflow model by Beloborodov for hard X-ray emission from magnetars. The outflow from a ring on the magnetar surface is statistically preferred over outflow from a polar cap.

79 ASTRONOMY AND ASTROPHYSICS↗