Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Spectrometer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

A new forward spectrometer for PHENIX

In the last decade PHENIX has accessed via longitudinal double spin asymmetries the gluon helicity inside the proton, started probing flavor dependent valence and sea quark helicity distributions and started to explore the proton transverse spin structure. A major upgrade is planned for the next decade that will provide an increased acceptance and additional tracking and electromagnetic plus hadronic calorimetry in the forward region. Here, the layout of the new forward detector system will be discussed, together with the new insights in the proton spin structure that the new forward PHENIX spectrometer will provide.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Specifics of Preparation of Storage Chambers for Ultracold Neutrons and EDM Spectrometer Sensitivity

Storage cells for ultracold neutrons (UCNs) are crucial parts of the experimental setup used to measure the electric dipole moment (EDM) of a neutron. The effect of the technology of preparation and sputtering of elements of UCN storage cells on the limiting operating voltage and on the capacity of these cells for long-term operation under high voltage with polarity switching was studied. A voltage magnitude of ±250 kV was obtained in tests of a neutron storage cell for the EDM spectrometer with a cell height of 9 cm.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A Prism Mass-Spectrometer for Isotope Analysis of Hydrogen–Helium Mixtures

An original scheme of a special magnetic mass-spectrometer for isotope measurements in a mass range of hydrogen–helium mixtures and their main impurities is proposed. The ion optics system contains a two-dimensional magnetic prism supplemented with two identical cylindrical electrostatic capacitors matched so that the system operates in the regime of complete triple focusing of the ion beam in two orthogonal directions and with respect to ion energies. The system ensures high dispersion and allows the mass resolution (no less than 3500) required for analysis at high brightness and a central ion trajectory length on the order of 1 m.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Spatial Heterodyne Raman Spectrometer (SHRS) for In Situ Chemical Sensing Using Sapphire and Silica Optical Fiber Raman Probes

A spatial heterodyne Raman spectrometer (SHRS), constructed using a modular optical cage and lens tube system, is described for use with a commercial silica and a custom single-crystal (SC) sapphire fiber Raman probe. The utility of these fiber-coupled SHRS chemical sensors is demonstrated using 532 nm laser excitation for acquiring Raman measurements of solid (sulfur) and liquid (cyclohexane) Raman standards as well as real-world, plastic-bonded explosives (PBX) comprising 1,3,5- triamino- 2,4,6- trinitrobenzene (TATB) and octahydro-1,3,5,7-tetranitro-1,3,5,7-tetrazocine (HMX) energetic materials. The SHRS is a fixed grating-based dispersive interferometer equipped with an array detector. Each Raman spectrum was extracted from its corresponding fringe image (i.e., interferogram) using a Fourier transform method. Raman measurements were acquired with the SHRS Littrow wavelength set at the laser excitation wavelength over a spectral range of ∼1750 cm −1 with a spectral resolution of ∼8 cm −1 for sapphire and ∼10 cm −1 for silica fiber probes. The large aperture of the SHRS allows much larger fiber diameters to be used without degrading spectral resolution as demonstrated with the larger sapphire collection fiber diameter (330 μm) compared to the silica fiber (100 μm). Unlike the dual silica fiber Raman probe, the dual sapphire fiber Raman probe did not include filtering at the fiber probe tip nearest the sample. Even so, SC sapphire fiber probe measurements produced less background than silica fibers allowing Raman measurements as close as ∼85 cm −1 to the excitation laser. Despite the short lengths of sapphire fiber used to construct the sapphire probe, well-defined, sharp sapphire Raman bands at 420, 580, and 750 cm −1 were observed in the SHRS spectra of cyclohexane and the highly fluorescent HMX-based PBX. SHRS measurements of the latter produced low background interference in the extracted Raman spectrum because the broad band fluorescence (i.e., a direct current, or DC, component) does not contribute to the interferogram intensity (i.e., the alternating current, or AC, component). SHRS spectral resolution, throughput, and signal-to-noise ratio are also discussed along with the merits of using sapphire Raman bands as internal performance references and as internal wavelength calibration standards in Raman measurements.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Improvements in Fabrication of Elastic Scattering Foils Used to Measure Neutron Yield by the Magnetic Recoil Spectrometer

The magnetic recoil spectrometer uses a deuterated polyethylene polymer (CD 2 ) foil to measure neutron yield in inertial confinement fusion experiments. Higher neutron yields in recent experiments have resulted in primary signal saturation in the detector CR-39 foils, necessitating the fabrication of thinner CD 2 foils than established methods could provide. A novel method of fabricating deuterated polymer foils is described. The resulting foils are thinner, smoother, and more uniform in thickness than the foils produced by previous methods. Here, these new foils have successfully been deployed at the National Ignition Facility, enabling higher neutron yield measurements than previous foils, with no primary signal saturation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Non-destructive Assay Measurements Using the RPI Lead Slowing Down Spectrometer

The use of a Lead Slowing-Down Spectrometer (LSDS) is consid- ered as a possible option for non-destructive assay of fissile material of used nuclear fuel. The primary objective is to quantify the 239Pu and 235U fissile content via a direct measurement, distinguishing them through their characteristic fission spectra in the LSDS. In this pa- per, we present several assay measurements performed at the Rensse- laer Polytechnic Institute (RPI) to demonstrate the feasibility of such a method and to provide benchmark experiments for Monte Carlo cal- culations of the assay system. A fresh UOX fuel rod from the RPI Criticality Research Facility, a 239PuBe source and several highly en- riched 235U discs were assayed in the LSDS. The characteristic fission spectra were measured with 238U and 232Th threshold fission cham- bers, which are only sensitive to fission neutron with energy above the threshold. Despite the constant neutron and gamma background from the PuBe source and the intense interrogation neutron flux, the LSDS system was able to measure the characteristic 235U and 239Pu responses. All measurements were compared to Monte Carlo simula- tions. It was shown that the available simulation tools and models are well suited to simulate the assay, and that it is possible to calculate the absolute count rate in all investigated cases.

Lead Slowing Down Spectrometer↗

Detection of indoor biological hazards using the man-portable laser induced breakdown spectrometer

The performance of a man-portable laser induced breakdown spectrometer was evaluated for the detection of biological powders on indoor office surfaces and wipe materials. Identification of pure unknown powders was performed by comparing against a library of spectra containing biological agent surrogates and confusant materials, such as dusts, diesel soot, natural and artificial sweeteners, and drink powders, using linear correlation analysis. Simple models constructed using a second technique, partial least squares discriminant analysis, successfully identified Bacillus subtilis (BG) spores on wipe materials and office surfaces. Furthermore, these models were able to identify BG on materials not used in the training of the model.

60 APPLIED LIFE SCIENCES↗

Aberration-corrected Czerny-Turner imaging spectrometer with a wide spectral region

A modified asymmetrical Czerny-Turner arrangement with a fixed plane grating is proposed to correct aberrations over a wide spectral region by analysis of the dependence of aberration correction for different wavelengths. The principle and method of aberration correction are described in detail. We compare the performance of this modified Czerny-Turner arrangement with that of the existing Czerny-Turner arrangement by using a practical Czerny-Turner imaging spectrometer example.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Broadband astigmatism-free Czerny-Turner imaging spectrometer using spherical mirrors

We describe the elimination of the astigmatism of a Czerny-Turner imaging spectrometer, built using spherical optics and a plane grating, over a broad spectral region. Starting with the principle of divergent illumination of the grating, which removes astigmatism at one chosen wavelength, we obtain design equations for the distance from the grating to the focusing mirror and the detector angle that remove the astigmatism to first order in wavelength. Experimentally, we demonstrate near diffraction-limited performance from 740 to 860 nm and over a 5 mm transverse spatial extent, while ray-tracing calculations show that barring finite-aperture and detector size limitations, this range extends from 640 to 900 nm and over 10 mm transversely. Our technique requires no additional optics and uses standard off-the-shelf components.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Terahertz spectroscopy with a holographic Fourier transform spectrometer plus array detector using coherent synchrotron radiation

By use of coherent terahertz synchrotron radiation, we experimentally tested a holographic Fourier transform spectrometer coupled to an array detector to determine its viability as a spectral device. Somewhat surprisingly, the overall performance strongly depends on the absorptivity of the birefringent lithium tantalate pixels in the array detector.

43 PARTICLE ACCELERATORS↗

Astigmatism-corrected Czerny-Turner imaging spectrometer for broadband spectral simultaneity

A low-cost, broadband, astigmatism-corrected Czerny-Turner arrangement with a fixed plane grating is proposed. A wedge cylindrical lens is used to correct astigmatism over a broadband spectral range. The principle and method of astigmatism correction are described in detail. We compare the performance of this modified Czerny-Turner arrangement with that of the traditional Czerny-Turner arrangement by using a practical Czerny-Turner imaging spectrometer example.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Compact millimeter-wavelength Fourier-transform spectrometer

Here, we have constructed a Fourier-transform spectrometer (FTS) operating between 50 GHz and 330 GHz with minimum volume (355×260×64 mm) and weight (5.9 kg) while maximizing optical throughput (100 mm 2 sr) and optimizing the spectral resolution (4 GHz). This FTS is designed as a polarizing Martin–Puplett interferometer with unobstructed input and output in which both input polarizations undergo interference. The instrument construction is simple with mirrors milled on the box walls and one motorized stage as the single moving element. We characterize the performance of the FTS, compare the measurements to an optical simulation, and discuss features that relate to details of the FTS design. The simulation is also used to determine the tolerance of optical alignments for the required specifications. We detail the FTS mechanical design and provide the control software as well as the analysis code online.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Frequency calibration of terahertz time-domain spectrometers

We present three techniques of calibrating frequency and spectral profile measurements of terahertz time-domain spectrometers. The first utilizes the etalon effect generated by multiple reflections in thin nonabsorbing samples. The second employs a CO gas cell to provide multiple narrow absorption lines at known frequencies. The third aims to use a grating monochromator to produce an independently measured comparable spectrum.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

6000 lines/mm blazed grating for a high-resolution x-ray spectrometer

We have designed and fabricated a high groove density blazed grating for a Resonant Inelastic X-ray Scattering spectrometer for the new Qerlin beamline at the Advanced Light Source (ALS) synchrotron facility. The gratings were fabricated using a set of nanofabrication techniques including e-beam lithography, nanoimprint, plasma etch, and anisotropic wet etching. Two gratings with groove density of 6000 lines/mm and 3000 lines/mm and optimized for operation in the 1st and 2nd negative diffraction order respectively were fabricated and tested. We report on fabrication details and characterization of the gratings at beamline 6.3.2 of the ALS.

36 MATERIALS SCIENCE↗

Development of a spatially resolving x-ray crystal spectrometer for measurement of ion-temperature (T[sub i]) and rotation-velocity (v) profiles in ITER

Imaging x-ray crystal spectrometer XCS arrays are being developed as a US-ITER activity for Doppler measurement of Ti and v profiles of impurities (W, Kr, and Fe) with ~ 7 cm (a/30) and 10-100 ms resolution in ITER. The imaging XCS, modeled after a prototype instrument on Alcator C-Mod, uses a spherically bent crystal and 2D x-ray detectors to achieve high spectral resolving power (E / dE > 6000) horizontally and spatial imaging vertically. Two arrays will measure Ti and both poloidal and toroidal rotation velocity profiles. The measurement of many spatial chords permits tomographic inversion for the inference of local parameters. The instrument design, predictions of performance, and results from C-Mod are presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Lead Slowing Down Spectrometer Status Report

This report documents the progress that has been completed in the first half of FY2012 in the MPACT-funded Lead Slowing Down Spectrometer project. Significant progress has been made on the algorithm development. We have an improve understanding of the experimental responses in LSDS for fuel-related material. The calibration of the ultra-depleted uranium foils was completed, but the results are inconsistent from measurement to measurement. Future work includes developing a conceptual model of an LSDS system to assay plutonium in used fuel, improving agreement between simulations and measurement, design of a thorium fission chamber, and evaluation of additional detector techniques.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of Tandem, Double-Focusing, Electron Impact, Gas Source Mass Spectrometer for Measurement of Rare Double-Substituted Isotoplogues in Geochemistry

This project culminated in construction and delivery of the world’s first large-radius gas-source isotope ratio mass spectrometer that permits unparalleled analyses of the stable isotopic composition of methane gas. The instrument, referred to as the “Panorama” and installed at UCLA in March 2015, can now be used to determine the relative abundances of rare isotopic species of methane that serve as tracers of temperature of formation and/or subsequent processing of gas. With this technology we can begin to delineate different sources and sinks of methane isotopically in ways not possible until now.

47 OTHER INSTRUMENTATION↗