Spectral distribution of direct and diffuse solar energy received at sea level of a model atmosphere
Explore the source record for details and available documents.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Various silicon hybrid systems are modeled and compared with a gallium arsenide hybrid system. The hybrid systems modeled produce electric power and also thermal power which can be used for heating or air conditioning. Various performance indices are defined and used to compare the system performance: capital cost per electric power out; capital cost per total power out; capital cost per electric power plus mechanical power; annual cost per annual electric energy; and annual cost per annual electric energy plus annual mechanical work. These performance indices indicate that concentrator hybrid systems can be cost effective when compared with present day energy costs.
Explore the source record for details and available documents.
Bibliography lists over 100 ongoing projects, Tech Briefs, papers and periodicals, and technical reports and patents pertaining to work performed at Marshall Space Flight Center and by its contractors. Each item includes brief summary or abstract of work, its publication date (except for ongoing research), and a listing of other materials related to that work. Comprehensive subject index is also included.
Purple fluorocarbon ethylene propylene (FEP) films are more efficient due to low absorptance. Designers seeking to improve coatings quantify this effect and devise simple screening test based on transmittance of films.
Tests indicate performance very close to theoretical predictions. Major objectives were to verify system installation techniques, operation, and performance; to verify performance of individual subsystems; and to provide general test data base comparison with field data.
An instrument was developed to continually integrate the energy available in incident light on a specifically oriented surface. The unit was designed for outdoor use in remote locations and is capable of operation over a temperature range of -20 to +60 C with good accuracy. The unit is weather resistant, requires low power, has a high input impedance, is inexpensive, and has a visual readout and an analog output for recording.
The test article, Model EF-212, Serial Nr. 002, is a single glazed collector with a nonselective absorber plate, using flowing air as the heat transfer medium. The absorber plate and box frame are aluminum and the insulation is one inch isocyanurate foam board with thermal conductivity of 0.11 (BTU/sq ft Hr0/ft.) The tests included the following. (1) time constant test, (2) collector efficiency test, (3) collector stagnation test, (4) incident angle modifier test, (5) load test, (6) weathering test, and (7) absorber plate optical properties test. The results of these tests are tabulated, graphed, or otherwise recorded.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
A parabolic reflector is supported so that it can track the sun. The support for this reflector comprises an azimuth frame supported on two wheels and a central pivotal point which are positioned in a substantially triangular configuration. On top of the azimuth frame, there is provided an elevation frame. The reflector rides on wheels captured within curved rails. The wheels of the azimuth frame are driven by an azimuth actuator. The reflector structure is counterbalanced about its elevation axis by a pendulum cable system which is driven by a motor. At the focal point of the parabolic reflector, a heat engine or receiver is mounted independently on the reflector. Suitable means are provided for moving the reflector about its two axes.
The simulation model for wind energy storage (SIMWEST) program now includes wind and/or photovoltaic systems utilizing any combination of five types of storage (pumped hydro, battery, thermal, flywheel and pneumatic) and is available for the UNIVAC 1100 series and the CDC 6000 series computers. The level of detail is consistent with a role of evaluating the economic feasibility as well as the general performance of wind and/or photovoltaic energy systems. The software package consists of two basic programs and a library of system, environmental, and load components. The first program is a precompiler which generates computer models (in FORTRAN) of complex wind and/or photovoltaic source/storage/application systems, from user specifications using the respective library components. The second program provides the techno-economic system analysis with the respective I/0, the integration of system dynamics, and the iteration for conveyance of variables.
Additions or revisions of components of the SIMWEST program are provided for insertion into the manual used with the UNIVAC 1100 series computer.
System has been evaluated for performance at test site in Loxahatchee, Florida. Results of tests are available in 76 page report. Projected annual electrical energy savings are above 10 million Btu.
Report discusses system for Minnesota residence. Final design was arrived at that will meet 45 percent of total average heating load and will supply 40 gallons of potable ater at 140 deg F. Document contains detailed drawings, specifications, and cost tradeoff studies. Also included are outline of proposed installation, operation and maintenance manual, and analysis of hazards.
Heating and cooling system uses Fresnel lens concentrating collectors. Major system components are 36 collectors, 1,500 gallon thermal storage tank, absorption cooler, cooling tower, heating coil, pumps, heat exchanger, and backup heating and air conditioning. Final report includes detailed breakdown of component and installation costs for seven project subsystems.
System preheats 100 percent of domestic hot water and supplies almost half of heating requirements for three story, concrete frame, brick building with basement. Final report includes details of installation, operation and maintenance, contract negotiation, and acceptance test plan.