Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Simulation methods.”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

SU-D-18A-01: Tumor Motion Tracking with a Regional Deformable Registration Model for Four Dimensional Radiation Treatment of Lung Cancer

Purpose: To develop a tumor motion model from four-dimensional computed tomography (4DCT) of thoracic patients and demonstrate its impact on 4D radiation therapy simulation. Methods: A regional deformable image registration algorithm was introduced to extract tumor motion out of patient's breathing cycle. The gross target volume (GTV) was manually delineated on a selected phase of 4DCT and a subregion with 10mm margin supplemented to the GTV was created on the Eclipse treatment planning system (Varian Medical Systems, Palo Alto, CA). Together with 4DCT the structures were exported into an inhouse research platform. A free form B-Spline deformable registration was carried out to map the subregion to other respiratory phases. The displacement vector fields were employed to propagate GTV contours with which the center of mass (CoM) of the GTV was computed for each breathing phase of 4DCT. The resultant GTV motion and its volumetric shape are utilized to facilitate 4D treatment planning. Five lung cancer patients undergoing stereotactic body radiation therapy were enrolled and their 4DCT sets were included in the study. Results: Application of the algorithm to five thoracic patients indicates that clinically satisfactory outcomes were achievable with a spatial accuracy better than 2mm for GTV contour propagation between adjacent phases, and 3mm between opposite phases. The GTV CoM was found to be in the range of 2.0mm through 2.5cm, depending upon the tumor location. Compared to the traditional whole image based registration, the computation of the regional model was found to be an order of magnitude more efficient. Conclusion: A regional deformable registration model was implemented to extract tumor motion. It will have widespread application in 4D radiation treatment planning in the future to maximally utilize the available spatial-tempo information.

60 APPLIED LIFE SCIENCES↗

SU-E-J-137: Incorporating Tumor Regression Into Robust Plan Optimization for Head and Neck Radiotherapy

Purpose: To develop a robust planning paradigm which incorporates a tumor regression model into the optimization process to ensure tumor coverage in head and neck radiotherapy. Methods: Simulation and weekly MR images were acquired for a group of head and neck patients to characterize tumor regression during radiotherapy. For each patient, the tumor and parotid glands were segmented on the MR images and the weekly changes were formulated with an affine transformation, where morphological shrinkage and positional changes are modeled by a scaling factor, and centroid shifts, respectively. The tumor and parotid contours were also transferred to the planning CT via rigid registration. To perform the robust planning, weekly predicted PTV and parotid structures were created by transforming the corresponding simulation structures according to the weekly affine transformation matrix averaged over patients other than him/herself. Next, robust PTV and parotid structures were generated as the union of the simulation and weekly prediction contours. In the subsequent robust optimization process, attainment of the clinical dose objectives was required for the robust PTV and parotids, as well as other organs at risk (OAR). The resulting robust plans were evaluated by looking at the weekly and total accumulated dose to the actual weekly PTV and parotid structures. The robust plan was compared with the original plan based on the planning CT to determine its potential clinical benefit. Results: For four patients, the average weekly change to tumor volume and position was −4% and 1.2 mm laterally-posteriorly. Due to these temporal changes, the robust plans resulted in an accumulated PTV D95 that was, on average, 2.7 Gy higher than the plan created from the planning CT. OAR doses were similar. Conclusion: Integration of a tumor regression model into target delineation and plan robust optimization is feasible and may yield improved tumor coverage. Part of this research is supported by Varian Medical System.

60 APPLIED LIFE SCIENCES↗

TU-A-9A-11: Gold Nanoparticles Enhanced Diffuse Optical Tomography: A Proof of Concept Study

Purpose: To investigate the feasibility and potential of gold nanoparticles (GNP) enhanced diffuse optical tomography (DOT) as a novel imaging strategy for tumor detection. Methods: Simulation was performed on a digital homogeneous cylindrical phantom of 30mm×30mm. Gold nanorods (GNR) with aspect ratio 3.9 and effective radius 21.86nm were used as contrast agent. The peak light absorption for these GNR occurs at 842nm within the near-infrared region, with the absorption cross-section of 1.97×10{sup -14}m{sup -2} and scatter cross-section of 1.07×10{sup -14}m{sup -2}. A 6mmdiameter sphere of GNR solution was positioned inside the tissue-simulating phantom. Simulations were performed at the GNR concentration level of 1nM, 100pM and 10pM, respectively. The points representing laser sources and light detectors were around the phantom with 30o apart tangentially and 1mm apart axially for 9 rows. As one point being source, all the other points within the current row and nearby four rows become detectors. Hence there are 108 source points in total and 55 detector points corresponding to each source. Forward light transport at 842nm wavelength was run on a three-dimensional mesh of 33186 nodes (∼0.5mm resolution) to acquire the light emission data. Reconstruction was performed on a coarse mesh of 19408 nodes (∼1mm resolution) with ∼20minutes on a 2.4GHz CPU and 8GB RAM computer. Results: The position of the GNR solution at 1nM, 100pM and 10pM concentration was reconstructed, respectively, with <1mm error. The GNR concentration was interpreted from the reconstructed absorption coefficient within the enhanced volume. The reconstructed maximum concentrations were 0.3nM, 120.0pM, and 5.3pM, respectively. Conclusion: To the best of our knowledge, this is the first time to apply GNP to enhance DOT. The simulation results showed the high sensitivity of GNP enhanced DOT, which is in pM concentration level, compared to the μM level for MRI agents and nM level for PET agents.

60 APPLIED LIFE SCIENCES↗

TH-A-18C-08: Design of a Small Animal Contrast Enhanced Dual Energy CT

Purpose: Dual energy CT has a variety of uses in a small animal setting including quantification and enhanced visualization of contrast agent. This study aims to determine the best energy combinations for contrast enhanced DECT on the XRAD 225Cx (Precision x-ray), a small animal IGRT system with a nominal energy range of 20 – 225 kVp. Focus was placed on material density accuracy and low contrast detectability. Methods: Simulations of single energy scans of an object containing concentrations of iodine varying from 0.5 to 50 mg/ml were performed using the simulation package ImaSim. Energy spectra from 50 – 220 kVp were calculated using the same software. For approximate Poisson noise modeling, mAs were chosen such that 30% of the total 10cGy dose was assigned to the low energy scan. A calibration involving projections of objects containing different thicknesses of iodine (0–0.5 mm) and water (0–50 mm) was performed for each energy and fit to a cubic equation as the calibration curve for each energy pair. Results: Contrast to noise ratios of the iodine material images and accuracies in iodine density measurements were measured. Gradual improvements in each metric were seen with increasing high energy. Larger improvements in CNR were observed for decreasing the low energy. Errors in iodine density were generally close to 5% for concentrations of iodine above 3 mg/ml but increased to around 15% for 50 kVp, likely due to its proximity to the discontinuity caused by the k-edge of iodine. Conclusion: Based on these simulations, the best energy combination for detecting low concentrations of iodine using a projection space calibration procedure is 50/200 kVp. However, if accuracy is most important 80/220 kVp is ideal, with 60/220 kVp being a good compromise to achieve both goals. Future work is necessary to verify these conclusions with physical data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-J-188: Theoretical Estimation of Margin Necessary for Markerless Motion Tracking

Purpose: To estimate the margin necessary to adequately cover the target using markerless motion tracking (MMT) of lung lesions given the uncertainty in tracking and the size of the target. Methods: Simulations were developed in Matlab to determine the effect of tumor size and tracking uncertainty on the margin necessary to achieve adequate coverage of the target. For simplicity, the lung tumor was approximated by a circle on a 2D radiograph. The tumor was varied in size from a diameter of 0.1 − 30 mm in increments of 0.1 mm. From our previous studies using dual energy markerless motion tracking, we estimated tracking uncertainties in x and y to have a standard deviation of 2 mm. A Gaussian was used to simulate the deviation between the tracked location and true target location. For each size tumor, 100,000 deviations were randomly generated, the margin necessary to achieve at least 95% coverage 95% of the time was recorded. Additional simulations were run for varying uncertainties to demonstrate the effect of the tracking accuracy on the margin size. Results: The simulations showed an inverse relationship between tumor size and margin necessary to achieve 95% coverage 95% of the time using the MMT technique. The margin decreased exponentially with target size. An increase in tracking accuracy expectedly showed a decrease in margin size as well. Conclusion: In our clinic a 5 mm expansion of the internal target volume (ITV) is used to define the planning target volume (PTV). These simulations show that for tracking accuracies in x and y better than 2 mm, the margin required is less than 5 mm. This simple simulation can provide physicians with a guideline estimation for the margin necessary for use of MMT clinically based on the accuracy of their tracking and the size of the tumor.

60 APPLIED LIFE SCIENCES↗

MO-FG-303-06: Evaluation of the Performance of Very High-Energy Electron (VHEE) Beams in Radiotherapy: Five Clinical Cases

Purpose: To evaluate the performance of 100–120 MeV very-high energy electron (VHEE) scanning pencil beams to radiotherapy by means of Monte Carlo (MC) simulations. Methods: We selected five clinical cases with target sizes of 1.2 cm{sup 3} to 990.4 cm{sup 3}. We calculated VHEE treatment plans using the MC EGSnrc code implemented in a MATLAB-based graphical user interface developed by our group. We generated phase space data for beam energies: 100 and 120 MeV and pencil beam spot sizes of 1, 3, and 5 mm at FWHM. The number of equidistant beams considered in this work was 16 or 32. Dose was calculated and then imported into a research version of RayStation where treatment plan optimization was performed. We compared the VHEE plans with the clinically delivered volumetric modulated arc therapy (VMAT) plan to evaluate VHEE plans performance. Results: VHEE plans provided the same PTV coverage and dose homogeneity than VMAT plans for all the cases. In average, the mean dose to organs at risk (OARs) was 24% lower for the VHEE plans. The structures that benefited the most from using VHEE were: large bowel for the esophagus case, chest wall for the liver case, brainstem for the acoustic case, carina for the lung case, and genitalia for the anal case, with 23.7–34.6% lower dose. VHEE dose distributions were more conformal than VMAT solution as confirmed by conformity indices CI100 and CI50. Integral dose to the body was in average 19.6% (9.2%–36.5%) lower for the VHEE plans. Conclusion: We have shown that VHEE plans resulted in similar or superior dose distributions compared to clinical VMAT plans for five different cases and a wide range of target volumes, including a case with a small target (1.2 cm{sup 3}), which represents a challenge for VMAT planning and might require the use of more complex non-coplanar VMAT plans. B Palma: None. M Bazalova: None. B Hardemark: Employee, RaySearch Laboratories AB. E Hynning: Employee, RaySearch Laboratories AB. B Qu: None. B Loo Jr.: Research support, RaySearch, Varian. P Maxim: Research support, RaySearch, Varian.

60 APPLIED LIFE SCIENCES↗

SU-G-IeP4-14: Prostate Brachytherapy Activity Measurement and Source Localization by Using a Dual Photon Emission Computed Tomography System: A Feasibility Study

Purpose: To monitor the activity distribution and needle position during and after implantation in operating rooms. Methods: Simulation studies were conducted to assess the feasibility of measurement activity distribution and seed localization using the DuPECT system. The system consists of a LaBr3-based probe and planar detection heads, a collimation system, and a coincidence circuit. The two heads can be manipulated independently. Simplified Yb-169 brachytherapy seeds were used. A water-filled cylindrical phantom with a 40-mm diameter and 40-mm length was used to model a simplified prostate of the Asian man. Two simplified seeds were placed at a radial distance of 10 mm and tangential distance of 10 mm from the center of the phantom. The probe head was arranged perpendicular to the planar head. Results of various imaging durations were analyzed and the accuracy of the seed localization was assessed by calculating the centroid of the seed. Results: The reconstructed images indicate that the DuPECT can measure the activity distribution and locate the seeds dwelt in different positions intraoperatively. The calculated centroid on average turned out to be accurate within the pixel size of 0.5 mm. The two sources were identified when the duration is longer than 15 s. The sensitivity measured in water was merely 0.07 cps/MBq. Conclusion: Preliminary results show that the measurement of the activity distribution and seed localization are feasible using the DuPECT system intraoperatively. It indicates the DuPECT system has potential to be an approach for dose-distribution-validation. The efficacy of acvtivity distribution measurement and source localization using the DuPECT system will evaluated in more realistic phantom studies (e.g., various attenuation materials and greater number of seeds) in the future investigation.

60 APPLIED LIFE SCIENCES↗

Sci-Thur AM: YIS – 07: Optimizing dual-energy x-ray parameters using a single filter for both high and low-energy images to enhance soft-tissue imaging

Objective: To optimize dual-energy parameters of ExacTrac stereoscopic x-ray imaging system for lung SBRT patients Methods: Simulated spectra and a lung phantom were used to optimize filter material, thickness, kVps, and weighting factors to obtain bone subtracted dual-energy images. Spektr simulations were used to identify material in the atomic number (Z) range [3–83] based on a metric defined to separate spectrums of high and low energies. Both energies used the same filter due to time constraints of image acquisition in lung SBRT imaging. A lung phantom containing bone, soft tissue, and a tumor mimicking material was imaged with filter thicknesses range [0–1] mm and kVp range [60–140]. A cost function based on contrast-to-noise-ratio of bone, soft tissue, and tumor, as well as image noise content, was defined to optimize filter thickness and kVp. Using the optimized parameters, dual-energy images of anthropomorphic Rando phantom were acquired and evaluated for bone subtraction. Imaging dose was measured with dual-energy technique using tin filtering. Results: Tin was the material of choice providing the best energy separation, non-toxicity, and non-reactiveness. The best soft-tissue-only image in the lung phantom was obtained using 0.3 mm tin and [140, 80] kVp pair. Dual-energy images of the Rando phantom had noticeable bone elimination when compared to no filtration. Dose was lower with tin filtering compared to no filtration. Conclusions: Dual-energy soft-tissue imaging is feasible using ExacTrac stereoscopic imaging system utilizing a single tin filter for both high and low energies and optimized acquisition parameters.

60 APPLIED LIFE SCIENCES↗

Atomistic and Ab initio modeling of CaAl{sub 2}O{sub 4} high-pressure polymorphs under Earth’s mantle conditions

Semi-empirical and ab initio theoretical investigation of crystal structure geometry, interatomic distances, phase densities and elastic properties for some CaAl{sub 2}O{sub 4} phases under pressures up to 200 GPa was performed. Two independent simulation methods predicted the appearance of a still unknown super-dense CaAl{sub 2}O{sub 4} modification. In this structure, the Al coordination polyhedron might be described as distorted one with seven vertices. Ca atoms were situated inside polyhedra with ten vertices and Ca–O distances from 1.96 to 2.49 Å. It became the densest modification under pressures of 170 GPa (density functional theory prediction) or 150 GPa (semi-empirical prediction). Both approaches indicated that this super-dense CaAl{sub 2}O{sub 4} modification with a “stuffed α-PbO{sub 2}” type structure could be a probable candidate for mutual accumulation of Ca and Al in the lower mantle. The existence of this phase can be verified experimentally using high pressure techniques.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Relaxation dynamics in type-II superconductors with point-like and correlated disorder

We employ an elastic line model to investigate the steady-state properties and non-equilibrium relaxation kinetics of magnetic vortex lines in disordered type-II superconductors using Langevin molecular dynamics (LMD). Here, we extract the dependence of the mean vortex line velocity and gyration radius as well as the mean-square displacement in the steady state on the driving current, and measure the vortex density and height autocorrelations in the aging regime. We study samples with either randomly distributed pointlike or columnar attractive pinning centers, which allows us to distinguish the complex relaxation features of interacting flux lines subject to extended vs. uncorrelated disorder. Additionally, we find that our new LMD findings match earlier Monte Carlo (MC) simulation data well, verifying that these two microscopically quite distinct simulation methods lead to macroscopically very similar results for non-equilibrium vortex matter.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Latent Variable Network Modeling

lvnm Is a library for fitting latent variable network models within the R programming language. The code focuses on the Stochastic Block Model, Weighted Stochastic Block Model, and Dynamic Stochastic Block Model. Features include simulation methods, estimation methods, diagnostic plots and anomaly detection routines for network data.

Dabbs, Beau↗

Neural Phase Simulation

The Neural Phase Simulation (NPS) is a package of codes for simulating microstructure evolution and accelerated molecular dynamics with deep neural-networks based surrogate models. NPS is designed to offer quantitatively accurate and computationally efficient simulation capabilities by leveraging modern machine-learning techniques. The primary intended use cases of NPS are training neural network surrogate models, though performing simulations on a single node is also supported. The NPS surrogate models can be trained from ground truth simulation methods, which are supposed to be accurate but expensive, such as molecular dynamics, phase field methods, kinetic Monte Carlo and discrete dislocation dynamics.

Zhou, Fei↗

via-wind (A Visual Impact Assessment Tool for Wind Turbines) [SWR-24-87]

Via-wind is an open-source tool for conducting visual impact assessments for wind turbines. It combines geographic information system (GIS) and 3D simulation methods to account for the key factors driving the visual impact of installed wind turbines, including distance, viewing angle, turbine orientation, visual exposure, and the cumulative effects of multiple turbines. This software is optimized for use in high-performance computing environments to enable large scale (e.g., country-wide) analysis, but can also be run on a single server or personal computer. For more information, please see the related journal article: https://www.sciencedirect.com/science/article/pii/S0306261924021846

Lopez, Anthony↗

Inferring small-sample-reactivity worth from oscillation experiment with auto-corrected local flux

To estimate reactivity changes as a function of time from the signal of detectors count rates, one usually uses point kinetic equations. However, when detectors are located inside the core, it is often necessary to compute a correction factor to account for the flux-shape deformation (i.e. the change of detector efficiency that may have been induced by neutron absorbers movements). Various simulation methods have been developed depending on transients observed. They range from the resolution of static equations up to full-time-dependent neutron transport in 3D. However, those methods require high computational-cost calculations of local reaction rates that rely on nuclear data evaluations. Therefore, a 'measured' reactivity is never determined through pure measurements. Taking advantage of the known oscillation movement of a small sample at the center of the MINERVE reactor, the innovative algorithm presented in this paper derives the correction factor needed to get no time drift on reactivity steps. Derived correction factors are in good agreement with those obtained independently with TRIPOLI-4 through sensitivity analysis. Low sensitivity to the sample composition and moderate sensitivity to the detectors position reinforce the reliability of those results. This application paves the way to almost pure nuclear data reactivity measurements. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Self-assembled multifunctional nanostructures for surface passivation and photon management in silicon photovoltaics

This work reports the fabrication and characterization of multifunctional, nanostructured passivation layers formed using a self-assembly process that provide both surface passivation and improved light trapping in crystalline silicon photovoltaic (PV) cells. Scalable block copolymer self-assembly and vapor phase infiltration processes are used to form arrays of aluminum oxide nanostructures (Al 2 O 3 ) on crystalline silicon without substrate etching. The Al 2 O 3 nanostructures are characterized using scanning electron microscopy (SEM), transmission electron microscopy (TEM), and spectroscopic ellipsometry. Injection-level dependent photoconductance measurements are used to determine the effective carrier lifetime of the samples to confirm the nanostructures successfully passivate the Si surface. Finite element method simulations and reflectance measurement show that the nanostructures increase the internal rear reflectance of the PV cell by suppressing the parasitic optical losses in the metal contact. An optimized morphology of the structures is identified for their potential use in PV cells as multifunctional materials providing surface passivation, photon management, and carrier transport pathways.

14 SOLAR ENERGY↗

SiB3 simulations of gross primary productivity(GPP) and carbonyl sulfide (COS) plant flux

This data set contains Simple Biosphere Model (SiB3) simulations of North American carbon dioxide (CO2) gross primary productivity (GPP) and carbonyl sulfide (OCS) plant flux (Fplant). There are two Fplant simulation methods included: a methodologically simpler LRU-based method, and a more mechanistic leaf enzyme kinetic approach. These methods are described in detail in the references included with the dataset.Time span: 1 July 2008 through 31 Aug 2008 Spatial extent: Coterminus USA and most of Canada SpatialResolution: 60 km by 60 km

54 ENVIRONMENTAL SCIENCES↗

Computer Simulation and Experimental Validation on the Oxidation and Sulfate Corrosion Resistance of Novel Chromium Based High Temperature Alloys

This report summarizes our recent works of ab initio molecular dynamics inter-atomic potentials development on dilute rare earth element yttrium (Y) etc. doped chromium (Cr) alloy systems, its applications in oxidation and corrosion resistance simulation, and experiment validation on the candidate systems. The simulation methods, experimental validation techniques, achievements already reached, students training, and future improvement are briefly introduced.

36 MATERIALS SCIENCE↗

Verification and Validation of High-Fidelity Multi-Physics Simulation Codes for Advanced Nuclear Reactors (Year 2)

The project objective is to verify and validate a suite of high-fidelity multi-physics simulation methods and codes developed during the previous I-NERI projects, against Monte Carlo solutions and experimental measurements for LWR and VHTR cores. Using benchmark problems developed during the previous year, ANL and KAERI continued to work on verifying the neutronics code DeCART and associated cross section libraries. Initial progress was also made on validating the code against experimental data. KAERI focused on verifying the DeCART code against numerical benchmark problems such as a PMR200 2-D pin cell/core and a HTTR 2-D block/core as well as improving DeCART capabilities such as the cross-section library group structure optimization, the fundamental and generalized adjoint equation solver, cylindrical boundary treatment, improved ray tracing, and implementing the direct resonance integral table method for resonance treatment. Verification test results for the updated capabilities showed substantial improvements in the estimation of eigenvalue and reaction rates.

Lee, C. H.↗