Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Sim”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

SU-C-18A-05: Registration Accuracy of MR-Based Images to On-Board Megavoltage Cone-Beam CT for Brain Patient Setup

Purpose: To quantify the difference in isocenter shifts when co-registering MR and MR-based pseudo CTs (pCT) with on-board megavoltage conebeam CT (CBCT) images. Methods: Fast Spoiled Gradient Echo MRs were used to generate pCTs (research version of Advantage Sim MD™, GE Healthcare) for ten patients who had prior brain radiotherapy. The planning CT (rCT) for each was co-registered with the MR, and the plan isocenter and two other reference points were transferred to the MR and pCT. CBCT images (with the machine isocenter) from a single treatment day were coregistered with the 3 test images (MR, pCT and rCT), by two observers and by an automated registration algorithm. The reference points were used to calculate patient shifts and rotations from the registrations. The shifts calculated from the test image registrations were compared to each other and to the shifts performed by the therapists who treated the patients on that day. Results: The average difference in absolute value between the isocenter shifts from the MR-, pCT- and rCT-CBCT registrations, and the therapist shifts, were 2.02, 3.01 and 0.89 mm (craniocaudal), 1.14, 1.34 and 0.46 mm (lateral), and 1.37, 3.43 and 1.43 mm (vertical), respectively. The MR- and pCT-CBCT registrations differed by 1.99, and 2.53 mm (craniocaudal), 1.36, and 1.37 mm (lateral), and 0.74 and 2.34 mm (vertical), respectively, from the average rCT-CBCT shifts. On average, differences of 2.39 (craniocaudal), 1.28 (lateral) and 2.84 mm (vertical) were seen between the MR and pCT shifts. Rotations relative to the CBCT coordinate system were on average <2° for the MR and rCT, and <6° for the pCT. Conclusion: In this study, FSPGR MR-CBCT registrations were more precise compared to the pCT-CBCT registrations. For improved accuracy, MR sequences that are optimal for bony anatomy visualization are necessary. GE healthcare has provided a research version of Advantage Sim MD to UCSF. No financial support was provided.

60 APPLIED LIFE SCIENCES↗

SU-E-T-19: A New End-To-End Test Method for ExacTrac for Radiation and Plan Isocenter Congruence

Purpose: To combine and integrate quality assurance (QA) of target localization and radiation isocenter End to End (E2E) test of BrainLAB ExacTrac system, a new QA approach was devised using anthropomorphic head and neck phantom. This test insures the target localization as well as radiation isocenter congruence which is one step ahead the current ExacTrac QA procedures. Methods: The head and neck phantom typically used for CyberKnife E2E test was irradiated to the sphere target that was visible in CT-sim images. The CT-sim was performed using 1 mm thickness slice with helical scanning technique. The size of the sphere was 3-cm diameter and contoured as a target volume using iPlan V.4.5.2. A conformal arc plan was generated using MLC-based with 7 fields, and five of them were include couch rotations. The prescription dose was 5 Gy and 95% coverage to the target volume. For the irradiation, two Gafchromic films were perpendicularly inserted into the cube that hold sphere inside. The linac used for the irradiation was TrueBeam STx equipped with HD120 MLC. In order to use ExacTrac, infra-red head–array was used to correlate orthogonal X-ray images. Results: Using orthogonal X-rays of ExacTrac the phantom was positioned. For each field, phantom was check again with X-rays and re-positioned if necessary. After each setup using ExacTrac, the target was irradiated. The films were analyzed to determine the deviation of the radiation isocenter in all three dimensions: superior-inferior, left-right and anterior-posterior. The total combining error was found to be 0.76 mm ± 0.05 mm which was within sub-millimeter accuracy. Conclusion: Until now, E2E test for ExacTrac was separately implemented to test image localization and radiation isocenter. This new method can be used for periodic QA procedures.

60 APPLIED LIFE SCIENCES↗

TH-A-BRF-12: Assessment of 4D-MRI for Robust Motion and Volume Characterization

Purpose: Precise radiation therapy for abdominal lesions is complicated by respiratory motion and poor soft tissue contrast from 4DCT whereas 4DMRI provides superior tissue discrimination. We evaluated a novel 4D-MRI algorithm for MR-SIM motion management. Methods: Respiratory-triggered, T2-weighted single-shot Turbo Spin Echo 4D-MRI was evaluated for open high-field 1.0T MR-SIM. A programmable platform pulled objects on a trolley ∼2 cm superior-inferior (S-I) for “regular” (sinusoidal, (1-cos{sup 2}), 3-5 second periods) and “irregular” breathing patterns (exaggerated (1-cos{sup 2}) and patient curves), while a respiratory waveform was generated via a pressure sensor device. Coronal 4D-MRIs (2–12;10 phases, TE/TR/α = 35−61/6100 ms/90°, voxel=1×1×4 mm{sup 3}) were acquired for 54 unique phantom cases. Abdominal 4D−MRIs were evaluated for 5 healthy volunteers and 1 liver cancer patient (6–10 phases, TE/TR/α = 30−96/4500−6100 ms/90°, voxel=1×1×5–10 mm{sup 3}) on an IRB-approved protocol. Duty cycle, scan time, and excursion were evaluated between phase acquisitions and compared to coronal cine-MRI (∼1 frame/sec). Maximum intensity projections (MIPs) were analyzed. Results: In phantom, average duty cycle was 42.6 ± 11.4% (range: 23.6–69.1%). Regular, periodic breathing (sinusoidal, (1-cos{sup 2})) yielded higher duty cycles than irregular (48.5% and 35.9%, respectively, p<0.001) and fast periods had higher duty cycles than slow (50.4% for 3s and 39.4% for 5s, p<0.001). ∼4-fold acquisition time increase was measured for 10-phase versus 2-phase. MIP renderings revealed that SI object extent was underestimated a maximum of 4% (3mm) and 8% (6mm) for cine and 2-phase 4D-MRI, respectively, with respect to 10-phases. However, this was waveform dependent. A highly irregular breathing volunteer yielded lowest duty cycle (23%) and longest 10-phase scan time (∼14 minutes), although 6-phase acquisition for a liver cancer patient was reasonable (50% and 7.4 minutes, respectively). Conclusion: 4D-MRI offers potential for excursion characterization, although results suggest the use of adequate phases is important. Further application and clinical validation are warranted. Research supported in part by a grant from Philips HealthCare (Best, Netherlands) and an Internal Mentored Grant from Henry Ford Health System.

60 APPLIED LIFE SCIENCES↗

SU-F-P-03: Management of Time to Treatment Inititation: Case for An Electronic Whiteboard

Purpose: To determine if data mining of an electronic whiteboard improves the management of the Time to Treatment Initiation (TTI) in radiation oncology. Methods: An electronic whiteboard designed to help in managing the planning workflow and improves communication regarding patient planning progress was used to record the dates at which each phase of the planning process began or completed. These are CT Sim date, Plan Start, Physician Review, Physicist Review, Approval for Treatment Delivery, Setup or Verification of Simulation. Results: During clinical implementation, the electronic whiteboard was able to fulfill its primary objective of providing a transparent account of the planning progress of each patient. Peer pressure also meant that individual tasks, such as contouring, were easily brought to the attention of the responsible party and prioritized accordingly. Data mining to analyze the electronic whiteboard per patient (figure 1), per diagnosis (figure 2), per treatment modality (figure 3), per physician (figure 4), per planner (figure 5), etc., added another sophisticated tool in the management of Time to Treatment Initiation without compromising quality of the plans being generated. A longer than necessary time between CT Sim and Plan Start can be discussed among the members of the treatment team as an indication of inadequate/outdated CT Simulator, Contouring Tools, Image Fusion Tools, Other Imaging Studies (MRI, PET/CT) performed, etc. The same for the Plan Start to Physician Review where an extended time than expected may be due unrealistic planning goals, limited planning system features, etc. Conclusion: An Electronic Whiteboard in radiation oncology is not only helping with organizing planning workflow, it is also a potent tool that can be used to reduce the Time to Treatment Initiation by providing the clinic with hard data about the duration of each phase treatment planning as a function of different variable affecting the planning process. The work is supported by the Global Medical Physics Institute.

60 APPLIED LIFE SCIENCES↗

SU-F-T-519: Is Geometry Based Setup Sufficient for All of the Head and Neck Treatment Cases?: A Feasibility Study Towards the Dose Based Setup

Purpose: This study compares the geometric-based setup (GBS) which is currently used in the clinic to a novel concept of dose-based setup (DBS) of head and neck (H&N) patients using cone beam CT (CBCT) of the day; and evaluates the clinical advantages. Methods: Ten H&N patients who underwent re-simulation and re-plan due to noticeable anatomic changes during the course of the treatments were retrospectively reviewed on dosimetric changes in the assumption of no plan modification was performed. RayStation planning system (RaySearch Laboratories AB, Sweden) was used to match (ROI fusion module) between prescribed isodoseline (IDL) in the CBCT imported along with ROIs from re-planned CT and the IDL of original plan (Dose-based setup: DBS). Then, the CBCT plan based on daily setup using the GBS (previously used for a patient) and the DBS CBCT plan recalculated in RayStation compared against the original CT-sim plan. Results: Most of patients’ tumor coverage and OAR doses got generally worsen when the CBCT plans were compared with original CT-sim plan with GBS. However, when DBS intervened, the OAR dose and tumor coverage was better than the GBS. For example, one of patients’ daily average doses of right parotid and oral cavity increased to 26% and 36%, respectively from the original plan to the GBS planning. However, it only increased by 13% and 24%, respectively with DBS. GTV D95 coverage also decreased by 16% with GBS, but only 2% decreased with DBS. Conclusion: DBS method is superior to GBS to prevent any abrupt dose changes to OARs as well as PTV/CTV or GTV at least for some H&N cases. Since it is not known when the DBS is beneficial to the GBS, a system which enables the on-line DBS may be helpful for better treatment of H&N.

60 APPLIED LIFE SCIENCES↗

Study of multilayered SiGe semiconductor structures by X-ray diffractometry, grazing-incidence X-ray reflectometry, and secondary-ion mass spectrometry

In this publication, we report the results of studying a multilayerd nonperiodic SiGe/Si structure by the methods of X-ray diffractometry, grazing-angle X-ray reflectometry, and secondary-ion mass spectrometry (SIMS). Special attention is paid to the processing of the component distribution profile using the SIMS method and to consideration of the most significant experimental distortions introduced by this method. A method for processing the measured composition distribution profile with subsequent consideration of the influence of matrix effects, variation in the etching rate, and remnants of ion sputtering is suggested. The results of such processing are compared with a structure model obtained upon combined analysis of X-ray diffractometry and grazing-angle reflectometry data. Good agreement between the results is established. It is shown that the combined use of independent techniques makes it possible to improve the methods of secondary-ion mass spectrometry and grazing-incidence reflectometry as applied to an analysis of multilayered heteroepitaxial structures (to increase the accuracy and informativity of these methods)

36 MATERIALS SCIENCE↗

Wigner SU(4) symmetry, clustering, and the spectrum of $$^{12}$$C

Abstract We present lattice calculations of the low-lying spectrum of $$^{12}$$ 12 C using a simple nucleon–nucleon interaction that is independent of spin and isospin and therefore invariant under Wigner’s SU(4) symmetry. We find strong signals for all excited states up to $$\sim 15$$ ∼ 15 MeV above the ground state, and explore the structure of each state using a large variety of $$\alpha $$ α cluster and harmonic oscillator trial states, projected onto given irreducible representations of the cubic group. We are able to verify earlier findings for the $$\alpha $$ α clustering in the Hoyle state and the second $$2^+$$ 2 + state of $$^{12}$$ 12 C. The success of these calculations to describe the full low-lying energy spectrum using spin-independent interactions suggest that either the spin-orbit interactions are somewhat weak in the $$^{12}$$ 12 C system, or the effects of $$\alpha $$ α clustering are diminishing their influence. This is in agreement with previous findings from ab initio shell model calculations.

Shen, Shihang (ORCID:0000000280516466)↗

Large $$N_c$$ QCD phase diagram at $$\mu _B=0$$

Abstract Lattice studies suggest that at zero baryon chemical potential and increasing temperature there are three characteristic regimes in QCD that are connected by smooth analytical crossovers: a hadron gas regime at$$T < T_{ch}\sim 155$$ T < T ch ∼ 155 MeV, an intermediate regime, called stringy fluid, at$$T_{ch}< T < \sim 3 T_{ch}$$ T ch < T < ∼ 3 T ch , and a quark-gluon plasma regime at higher temperatures. These regimes have been interpreted to reflect different approximate symmetries and effective degrees of freedom. In the hadron gas the effective degrees of freedom are hadrons and the approximate chiral symmetry of QCD is spontaneously broken. The intermediate regime has been interpreted as lacking spontaneous chiral symmetry breaking along with the emergence of new approximate symmetry, chiral spin symmetry, that is not a symmetry of the Dirac Lagrangian, but is a symmetry of the confining part of the QCD Lagrangian. While the high temperature regime is the usual quark-gluon plasma which is often considered to reflect “deconfinement” in some way. This paper explores the behavior of these regimes of QCD as the number of colors in the theory,$$N_c$$ N c , gets large. In the large$$N_c$$ N c limit the theory is center-symmetric and notions of confinement and deconfinement are unambiguous. The energy density is$$\mathcal{O}(N_c^0)$$ O ( N c 0 ) in the meson gas,$${{\mathcal {O}}}(N_c^1)$$ O ( N c 1 ) in the intermediate regime and$${{\mathcal {O}}}(N_c^2)$$ O ( N c 2 ) in the quark-gluon plasma regime. In the large$$N_c$$ N c limit these regimes may become distinct phases separated by first order phase transitions. The intermediate phase has the peculiar feature that glueballs should exist and have properties that are unchanged from what is seen in the vacuum (up to$$1/N_c $$ 1 / N c corrections), while the ordinary dilute gas of mesons with broken chiral symmetry disappears and approximate chiral spin symmetry should emerge.

Physics↗

Final results on the $$0\nu \beta \beta $$ decay half-life limit of $$^{100}$$Mo from the CUPID-Mo experiment

Abstract The CUPID-Mo experiment to search for 0 $$\nu \beta \beta $$ ν β β decay in $$^{100}$$ 100 Mo has been recently completed after about 1.5 years of operation at Laboratoire Souterrain de Modane (France). It served as a demonstrator for CUPID, a next generation 0 $$\nu \beta \beta $$ ν β β decay experiment. CUPID-Mo was comprised of 20 enriched $$\hbox {Li}_{{2}}$$ Li 2 $$^{100}$$ 100 $$\hbox {MoO}_4$$ MoO 4 scintillating calorimeters, each with a mass of $$\sim 0.2$$ ∼ 0.2 kg, operated at $$\sim 20$$ ∼ 20 mK. We present here the final analysis with the full exposure of CUPID-Mo ( $$^{100}$$ 100 Mo exposure of 1.47 $$\hbox {kg} \times \hbox {year}$$ kg × year ) used to search for lepton number violation via 0 $$\nu \beta \beta $$ ν β β decay. We report on various analysis improvements since the previous result on a subset of data, reprocessing all data with these new techniques. We observe zero events in the region of interest and set a new limit on the $$^{100}$$ 100 Mo 0 $$\nu \beta \beta $$ ν β β decay half-life of $$T_{1/2}^{0\nu }$$ T 1 / 2 0 ν $$> {1.8}\times 10^{24}$$ > 1.8 × 10 24 year (stat. + syst.) at 90% CI. Under the light Majorana neutrino exchange mechanism this corresponds to an effective Majorana neutrino mass of $$\left $$ m β β $$<~{(0.28{-}0.49)} $$ < ( 0.28 - 0.49 ) eV, dependent upon the nuclear matrix element utilized.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Alignment of the Alpha Magnetic Spectrometer (AMS) in space

Abstract The Alpha Magnetic Spectrometer (AMS) is a precision particle physics detector operating at an altitude of $$\sim 410$$ ∼ 410 km aboard the International Space Station. The AMS silicon tracker, together with the permanent magnet, measures the rigidity (momentum/charge) of cosmic rays in the range from $$\sim 0.5$$ ∼ 0.5 GV to several TV. In order to have accurate rigidity measurements, the positions of more than 2000 tracker modules have to be determined at the micron level by an alignment procedure. The tracker was first aligned using the 400 GeV/c proton test beam at CERN and then re-aligned using cosmic-ray events after being launched into space. A unique method to align the permanent magnetic spectrometer for a space experiment is presented. The developed underlying mathematical algorithm is discussed in detail.

47 OTHER INSTRUMENTATION↗

A new benchmark of soft X-ray transition energies of $$\mathrm {Ne}$$, $$\mathrm {CO}_2$$, and $$\mathrm {SF}_6$$: paving a pathway towards ppm accuracy

Abstract A key requirement for the correct interpretation of high-resolution X-ray spectra is that transition energies are known with high accuracy and precision. We investigate the K-shell features of $$\mathrm {Ne}$$ Ne , $$\mathrm {CO}_2$$ CO 2 , and $$\mathrm {SF}_6$$ SF 6 gases, by measuring their photo ion-yield spectra at the BESSY II synchrotron facility simultaneously with the 1s– n p fluorescence emission of He-like ions produced in the Polar-X EBIT. Accurate ab initio calculations of transitions in these ions provide the basis of the calibration. While the $$\mathrm {CO}_2$$ CO 2 result agrees well with previous measurements, the $$\mathrm {SF}_6$$ SF 6 spectrum appears shifted by $$\sim $$ ∼ 0.5 eV, about twice the uncertainty of the earlier results. Our result for $$\mathrm {Ne}$$ Ne shows a large departure from earlier results, but may suffer from larger systematic effects than our other measurements. The molecular spectra agree well with our results of time-dependent density functional theory. We find that the statistical uncertainty allows calibrations in the desired range of 1–10 meV, however, systematic contributions still limit the uncertainty to $${\sim }$$ ∼ 40–100 meV, mainly due to the temporal stability of the monochromator energy scale. Combining our absolute calibration technique with a relative energy calibration technique such as photoelectron energy spectroscopy will be necessary to realize its full potential of achieving uncertainties as low as 1–10 meV. Graphical abstract

74 ATOMIC AND MOLECULAR PHYSICS↗

Electrochemical Performance and Stability of the Cathode for Solid Oxide Fuel Cells: III. Role of volatile boron species on LSM/YSZ and LSCF

Boron oxide is a key component to tailor the softening temperature and viscosity of the sealing glass for solid oxide fuel cells. The primary concern regarding the use of boron containing sealing glasses is the volatility of boron species, which possibly results in cathode degradation. In this paper, we report the role of volatile boron species on the electrochemical performance of LSM/YSZ and LSCF cathodes at various SOFC operation temperatures. The transport rate of boron, ~ 3.24×10-12 g/cm2•sec was measured at 750°C with air saturated with 2.8% moisture. A reduction in power density was observed in cells with LSM/YSZ cathodes after introduction of the boron source to the cathode air stream. Partial recovery of the power density was observed after the boron source was removed. Results from post-test secondary ion mass spectroscopy (SIMS) analysis the partial recovery in power density correlated with partil removal of the deposited boron by the clean air stream. The presence of boron was also observed in LSCF cathodes by SIMS analysis, however the effect of boron on the electrochemical performance of LSCF cathode was negligible. Coverage of triple phase boundaries in LSM/YSZ was postulated as the cause for the observed reduction in electrochemical performance.

30 DIRECT ENERGY CONVERSION↗

Molybdenum Sulfide within a Metal–Organic Framework for Photocatalytic Hydrogen Evolution from Water

A representative metal–organic framework, NU-1000, was functionalized with MoS x . The previously determined crystal structure of the material, named MoS x -SIM, consists of monometallic Mo(IV) ions with two sulfhydryl ligands. The metal ions are anchored to the framework by displacing protons presented by the –OH/–OH 2 groups on the Zr 6 node. As shown previously, the MOF-supported complexes are electrocatalytic for hydrogen evolution from acidified water. The earlier electrocatalysis results, together with the nearly ideal formal potential of the Mo(IV/II) couple (i.e., nearly coincident with that of the hydrogen couple), and the physical proximity of UV-absorbing MOF linkers to the complexes, suggested to us that the linkers might behave photosensitizers for catalyst reduction, and subsequently, for H 2 evolution from water. To our surprise, MoS x -SIM, when UV-illuminated in an aqueous buffer at near-neutral pH, displays a biphasic photocatalytic response: an initially slow rate of reaction, i.e. 0.56 mmol g -1 h -1 , followed by an increase to 4 mmol g -1 h -1 . Ex-situ catalyst examination revealed that nanoparticulate MoSx suspended within the reaction mixture is the actual catalyst. Thus, photo-assisted restructuring and detachment of the catalyst or pre-catalyst from the MOF node appears to be necessary for the catalyst to reduce water at neutral pH.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Energy Exchange Dynamics across L-H Transitions in NSTX

We studied the energy exchange dynamics across the low-to-high-confinement (L-H) in NSTX discharges using the gas-puff imaging (GPI) diagnotic. The investigation focused on the energy exchange between flows and turbulence, to help clarify the mechanism of the L-H transition. We apply this study to three type of heating schemes, including a total of 17 shots from the NSTX 2010 campaign run. Results show that the edge fluctuation characteristics (fluctuation levels, radial and poloidal correlation lengths) measured using GPI do not vary just prior to the H-mode transition, but change after the transition. Using a velocimetry approach (orthogonal-programming decomposition), velocity fields of a 24 $\times$ 30 cm GPI view during the L-H transition were obtained with good spatial ($\sim$1 cm) and temporal ($\sim$2.5 $\mu$s) resolutions. Analysis using these velocity fields shows that the production term is systematically negative just prior to the L-H transition indicating transfer from mean flows to turbulence, which is inconsistent with the predator-prey paradigm. Moreover, using the inferred absolute value of the production term, an estimate of the L-H transition duration is found to be 25 ms, which is much larger than the measured duration. These discrepancies are further reinforced by consideration of the ratio between the kinetic energy in the mean flow to the thermal free energy, which is estimated to be much less than 1, suggesting again that turbulence depletion mechanism may not be playing an important role in the transition to the H-mode. Although the Reynolds work is too small to directly deplete the turbulent free energy reservoir, order-of-magnitude analysis shows that the Reynolds stress may still make a non-negligible contribution to the observed poloidal flows.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Deep convolutional neural networks for multi-scale time-series classification and application to disruption prediction in fusion devices

The multi-scale, mutli-physics nature of fusion plasmas makes predicting plasma events challenging. Recent advances in deep convolutional neural network architectures (CNN) utilizing dilated convolutions enable accurate predictions on sequences which have long-range, multi-scale characteristics, such as the time-series generated by diagnostic instruments observing fusion plasmas. Here we apply this neural network architecture to the popular problem of disruption prediction in fusion tokamaks, utilizing raw data from a single diagnostic, the Electron Cyclotron Emission imaging (ECEi) diagnostic from the DIII-D tokamak. ECEi measures a fundamental plasma quantity (electron temperature) with high temporal resolution over the entire plasma discharge, making it sensitive to a number of potential pre-disruptions markers with different temporal and spatial scales. Promising, initial disruption prediction results are obtained training a deep CNN with large receptive field ({$\sim$}30k), achieving an $F_1$-score of {$\sim$}91\% on individual time-slices using only the ECEi data.

convolutional neural networks↗

Multiphysics Application Coupling Toolkit

This particular consortium implementation of the software integration infrastructure will, in large part, refactor portions of the Rocstar multiphysics infrastructure. Development of this infrastructure originated at the University of Illinois DOE ASCI Center for Simulation of Advanced Rockets (CSAR) to support the center's massively parallel multiphysics simulation application, Rocstar, and has continued at IllinoisRocstar, a small company formed near the end of the University-based program. IllinoisRocstar is now licensing these new developments as free, open source, in hopes to help improve their own and others' access to infrastructure which can be readily utilized in developing coupled or composite software systems; with particular attention to more rapid production and utilization of multiphysics applications in the HPC environment. There are two major pieces to the consortium implementation, the Application Component Toolkit (ACT), and the Multiphysics Application Coupling Toolkit (MPACT). The current development focus is the ACT, which is (will be) the substrate for MPACT. The ACT itself is built up from the components described in the technical approach. In particular, the ACT has the following major components: 1.The Component Object Manager (COM): The COM package provides encapsulation of user applications, and their data. COM also provides the inter-component function call mechanism. 2.The System Integration Manager (SIM): The SIM package provides constructs and mechanisms for orchestrating composite systems of multiply integrated pieces.

Campbell, MichaelT.↗

AbacusSummit Cleaned Halo Catalogs

This is a data release from the AbacusSummit suite of cosmological N-body simulations. It contains dark matter halo catalogs and particle samples from those halos. The halo catalogs have been augmented (cleaned) using halo merger tree information. Descriptions of AbacusSummit, the cleaned halo catalogs, and instructions for manipulating these catalogs can be found at the following URL: abacussummit.readthedocs.io/ The halo catalog cleaning is structured as a set of auxiliary files that are ingested by the reader code at runtime. But this release contains both the original catalogs and the auxiliary files, thus forming a self-contained dataset. The files in this release are aggregated by redshift. We define sets of simulations (like all c000 sims or all hugebase sims), and then store one redshift from all simulations per tarball. This is designed to support the use-case where a user wants to analyze multiple simulations at a certain redshift.

79 ASTRONOMY AND ASTROPHYSICS↗

Total internal reflection enabled wide-field coherent anti-Stokes Raman scattering microscopy

Wide-field coherent anti-Stokes Raman scattering (CARS) microscopy offers an attractive means for the rapid and simultaneous acquisition of vibrationally resolved images across a large field of view. A major challenge in the implementation lies in how to achieve sufficiently strong excitation fields necessary to drive the third-order optical responses over the large focal region. Here, we report a new wide-field CARS microscope enabled by a total internal reflection excitation scheme using a femtosecond Ti:Sapphire oscillator to generate pump and broadband near-infrared Stokes pulses. The spectrally broad Stokes pulse, in combination with its inherent chirp, offers not only access to a wide range of Raman modes spanning ${\sim}{1000}$ to ${\sim}{3500}\;{{\rm cm}^{- 1}}$ but also a straightforward means to select vibrational transitions within this range by simply varying the time delay between the pulses. The unique capabilities of this wide-field CARS microscope were validated by acquiring high-quality CARS images from the model and complex biological samples on conventional microscope coverslips.

36 MATERIALS SCIENCE↗