Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Signal detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

High-sensitivity telecommunication-compatible photoconductive terahertz detection through carrier transit time reduction

We present a telecommunication-compatible photoconductive terahertz detector realized without using any short-carrier-lifetime photoconductor. By utilizing plasmonic contact electrodes on a thin layer of high-mobility photoconductor, the presented detector offers a short transit time for the majority of the photocarriers in the absence of a short-carrier-lifetime photoconductor. Consequently, high-sensitivity terahertz detection is achieved with a record-high signal-to-noise ratio of 122 dB over a 3.6 THz bandwidth under an optical probe power of 10 mW. To achieve such a high sensitivity, the device geometry is chosen to maintain a high resistance and low Johnson Nyquist noise. This design approach can be widely applied for terahertz detection using various semiconductors and optical wavelengths, without being limited by the availability of short-carrier-lifetime photoconductors.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

CTA and SWGO can discover Higgsino dark matter annihilation

Thermal Higgsino dark matter (DM), with a mass near 1.1 TeV, is one of the most well-motivated and untested DM candidates. Leveraging recent hydrodynamic cosmological simulations that give DM density profiles in Milky Way analog galaxies we show that the linelike gamma-ray signal predicted from Higgsino annihilation in the Galactic Center could be detected at high significance with the upcoming Cherenkov Telescope Array (CTA) and Southern Wide-field Gamma-ray Observatory (SWGO) for all but the most pessimistic DM profiles. We perform the most sensitive search to-date for the linelike signal using 15 years of data from the Fermi Large Area Telescope, coming within an order one factor of the necessary sensitivity to detect the Higgsino for some Milky Way analog DM density profiles. We show that H.E.S.S. has subleading sensitivity relative to Fermi for the Higgsino at present. In contrast, we analyze H.E.S.S. inner Galaxy data for the thermal wino model with a mass near 2.8 TeV; we find no evidence for a DM signal and exclude the wino by over a factor of two in cross section for all DM profiles considered. In the process, we identify and attempt to correct what appears to be an inconsistency in previous H.E.S.S. inner Galaxy analyses for DM annihilation related to the analysis effective area, which may weaken the DM cross-section sensitivity claimed in those works by around an order of magnitude.

79 ASTRONOMY AND ASTROPHYSICS↗

A non-canonical fungal peroxisome PTS-1 signal, SYM, and its evolutionary aspects

Abstract Proteins localized to peroxisomes, particularly those expressed under specific conditions or in low abundance, are often undetected by routine proteomics methods due to detection sensitivity limits. In silico identification and experimental validation of peroxisomal targeting signals (PTSs) offer a reliable alternative. We demonstrate that SYM, a non-canonical plant PTS-1 signal, functions similarly inAspergillus nidulans, as GFP tagged with a SYM C-terminal tripeptide localizes to peroxisomes. One of two nativeA. nidulansproteins with C-terminal SYM tripeptide shows weak peroxisomal localization alongside cytoplasmic presence, indicating that only a subset of proteins with non-canonical signals access peroxisomes.In silicoanalysis of 1,010 fungal genomes identified diverse SYM-proteins with variable functions, suggesting that non-canonical PTS-1 signals may evolve spontaneously. Two-thirds of SYM-proteins are predicted to localize to specific intracellular compartments other than the peroxisome. We propose that despite their predicted localization, these proteins possessing SYM as a non-canonical peroxisomal signal might also have peroxisomal presence. Among SYM-proteins, pectinesterases, known plant pathogen virulence factors, were frequent. Notably, 25% of fungal pectinesterases harbor non-canonical PTS-1 signals, suggesting that partial peroxisomal localization of pectinesterases has evolved convergently. This suggests that partial peroxisomal localization may enhance protein functional flexibility, contributing to the organism’s adaptability.

Science & Technology - Other Topics↗

Dwarf galaxy halo masses from spectroscopic and photometric lensing in DESI and DES

We present the most precise and lowest-mass weak lensing measurements of dwarf galaxies to date, enabled by spectroscopic lenses from the Dark Energy Spectroscopic Instrument (DESI) and photometric lenses from the Dark Energy Survey (DES) calibrated with DESI redshifts. Using DESI spectroscopy from the first data release, we construct clean samples of galaxies with median stellar masses $\log_{10}(M_*/M_{\odot})=8.3-10.1$ and measure their weak lensing signals with sources from DES, KiDS, and SDSS, achieving detections with $S/N$ up to 14 for dwarf galaxies ($\log_{10}(M_*/M_{\odot})<$9.25) -- opening up a new regime for lensing measurements of low-mass systems. Leveraging DES photometry calibrated with DESI, we extend to a photometric dwarf sample of over 700,000 galaxies, enabling robust lensing detections of dwarf galaxies with combined $S/N=38$ and a significant measurement down to $\log_{10}(M_*/M_{\odot})=8.0$. We show that the one-halo regime (scales $\lesssim 0.15h^{-1}\rm Mpc$) is insensitive to various systematic and sample selection effects, providing robust halo mass estimates, while the signal in the two-halo regime depends on galaxy color and environment. These results demonstrate that DESI already enables precise dwarf lensing measurements, and that calibrated photometric samples extend this capability. Together, they pave the way for novel constraints on dwarf galaxy formation and dark matter physics with upcoming surveys like the Vera C. Rubin Observatory's LSST.

Treiber, Helena [Princeton U., Astrophys. Sci. Dep↗

Single particle detection system for strong-field QED experiments

Abstract Measuring signatures of strong-field quantum electrodynamics (SF-QED) processes in an intense laser field is an experimental challenge: it requires detectors to be highly sensitive to single electrons and positrons in the presence of the typically very strong x-ray and γ -photon background levels. In this paper, we describe a particle detector capable of diagnosing single leptons from SF-QED interactions and discuss the background level simulations for the upcoming Experiment-320 at FACET-II (SLAC National Accelerator Laboratory). The single particle detection system described here combines pixelated scintillation LYSO screens and a Cherenkov calorimeter. We detail the performance of the system using simulations and a calibration of the Cherenkov detector at the ELBE accelerator. Single 3 GeV leptons are expected to produce approximately 537 detectable photons in a single calorimeter channel. This signal is compared to Monte-Carlo simulations of the experiment. A signal-to-noise ratio of 18 in a single Cherenkov calorimeter detector is expected and a spectral resolution of 2% is achieved using the pixelated LYSO screens.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Optical Biosensor Platforms Display Varying Sensitivity for the Direct Detection of Influenza RNA

Detection methods that do not require nucleic acid amplification are advantageous for viral diagnostics due to their rapid results. These platforms could provide information for both accurate diagnoses and pandemic surveillance. Influenza virus is prone to pandemic-inducing genetic mutations, so there is a need to apply these detection platforms to influenza diagnostics. Here, we analyzed the Fast Evaluation of Viral Emerging Risks (FEVER) pipeline on ultrasensitive detection platforms, including a waveguide-based optical biosensor and a flow cytometry bead-based assay. The pipeline was also evaluated in silico for sequence coverage in comparison to the U.S. Centers for Disease Control and Prevention’s (CDC) influenza A and B diagnostic assays. The influenza FEVER probe design had a higher tolerance for mismatched bases than the CDC’s probes, and the FEVER probes altogether had a higher detection rate for influenza isolate sequences from GenBank. When formatted for use as molecular beacons, the FEVER probes detected influenza RNA as low as 50 nM on the waveguide-based optical biosensor and 1 nM on the flow cytometer. In addition to molecular beacons, which have an inherently high background signal we also developed an exonuclease selection method that could detect 500 pM of RNA. The combination of high-coverage probes developed using the FEVER pipeline coupled with ultrasensitive optical biosensors is a promising approach for future influenza diagnostic and biosurveillance applications.

59 BASIC BIOLOGICAL SCIENCES↗

A Robust Method to Secure Multi-Inverter Grid Tied PV and Battery Energy Storage Systems Against Cyber Intrusions

This paper details a robust method to secure a multi-inverter grid tied system that interfaces photovoltaic (PV) and battery energy storage against potential cyber-attacks. The method can be applied to any third-party inverter systems without a need to modify their internal controls. A small random private excitation signal termed "watermark" is injected into the DC input voltage terminals (via a series transformer) connected to the PV/battery inverter system. An external robust cyber intrusion detector (CID) hardware consisting of a digital signal processor (DSP) generates the "watermark" and also receives the sensor signals that control the setpoints of the PV/battery grid tied system. The CID algorithm is shown to detect all possible cyber intrusions (such as false data injection(FDI)) on external sensor signals such as P and Q measured by a smart meter that control the overall system operation. The proposed CID computes online system ID and two variance tests in real time on each sensor signal and is able pinpoint intrusion location in a multi-inverter system. Results on a hardware in the loop (HIL) of a two-inverter grid connected system demonstrate effectiveness of the proposed CID system for FDI and unobservable FDI. Test results on a laboratory prototype will be discussed in the conference presentation.

Ibrahim, Hasan↗

Detecting boosted dark photons with gaseous detectors

We search for indirect signals of O ( keV ) dark matter annihilating or decaying into O ( eV ) dark photons. These dark photons will be highly boosted, predominantly transversely polarized, have decay lengths larger than the Milky Way, and can be absorbed by neutrino or dark matter experiments at a rate dependent on the photon-dark photon kinetic mixing parameter and the optical properties of the experiment. We show that current experiments cannot probe new parameter space, but future large-scale gaseous detectors with low backgrounds (i.e., CYGNUS, NEXT, PANDAX-III) may be sensitive to this signal when the annihilation cross section is especially large. Published by the American Physical Society 2024

79 ASTRONOMY AND ASTROPHYSICS↗

Total variation vs L1 regularization: a comparison of compressive sensing optimization methods for chemical detection

One of the fundamental assumptions of compressive sensing (CS) is that a signal can be reconstructed from a small number of samples by solving an optimization problem with the appropriate regularization term. Two standard regularization terms are the L1 norm and the total variation (TV) norm. We present a comparison of CS reconstruction results based on these two approaches in the context of chemical detection, and we demonstrate that optimization based on the L1 norm outperforms optimization based on the TV norm. Our comparison is driven by CS sampling, reconstruction, and chemical detection in two real-world datasets: the Physical Sciences Inc. Fabry-Perot interferometer sensor multispectral dataset and the Johns Hopkins Applied Physics Lab FTIR-based longwave infrared sensor hyperspectral dataset. Both datasets contain the release of a chemical simulant such as glacial acetic acid, triethyl phosphate, and sulfur hexafluoride. For chemical detection we use the adaptive coherence estimator (ACE) and bulk coherence, and we propose algorithmic ACE thresholds to define the presence or absence of a chemical of interest in both un-compressed data cubes and reconstructed data cubes. The un-compressed data cubes provide an approximate ground truth. We demonstrate that optimization based on either the L1 norm or TV norm results in successful chemical detection at a compression rate of 90%, but we show that L1 optimization is preferable. We present quantitative comparisons of chemical detection on reconstructions from the two methods, with an emphasis on the number of pixels with an ACE value above the threshold.

Hyperspectral imagery, L1-norm, total variation, A↗

A prototype hybrid mode cavity for heterodyne axion detection

In the heterodyne approach to axion detection, axion dark matter induces transitions between two modes of a microwave cavity, resulting in a parametrically enhanced signal power. We describe the fabrication and characterization of a prototype normal conducting cavity specifically optimized for heterodyne detection. Corrugations on the cavity walls support linearly polarized hybrid modes which maximize the signal power while strongly suppressing noise. We demonstrate tuning mechanisms which allow one mode frequency to be scanned across a 4 MHz range, while suppressing cross-coupling noise by at least 80 dB. A future superconducting cavity with identical geometry to our prototype would have the potential to probe orders of magnitude beyond astrophysical bounds.

Li, Zenghai [SLAC]↗

Data for Selected Ion Monitoring for Orbitrap-Based Metabolomics

Orbitrap mass spectrometry in full scan mode enables the simultaneous detection of hundreds of metabolites and their isotope-labeled forms. Yet, sensitivity remains limiting for many metabolites, including low-concentration species, poor ionizers, and low-fractional-abundance isotope-labeled forms in isotope-tracing studies. Here, we explore selected ion monitoring (SIM) as a means of sensitivity enhancement. The analytes of interest are enriched in the orbitrap analyzer by using the quadrupole as a mass filter to select particular ions. In tissue extracts, SIM significantly enhances the detection of ions of low intensity, as indicated by improved signal-to-noise (S/N) ratios and measurement precision. In addition, SIM improves the accuracy of isotope-ratio measurements. SIM, however, must be deployed with care, as excessive accumulation in the orbitrap of similar m/z ions can lead, via space-charge effects, to decreased performance (signal loss, mass shift, and ion coalescence). Ion accumulation can be controlled by adjusting settings including injection time and target ion quantity. Overall, we suggest using a full scan to ensure broad metabolic coverage, in tandem with SIM, for the accurate quantitation of targeted low-intensity ions, and provide methods deploying this approach to enhance metabolome coverage.f

Mass Spectrometry↗

Attack detection and localization with adaptive thresholding

According to some embodiments, a system, method, and non-transitory computer readable medium are provided comprising a plurality of real-time monitoring nodes to receive streams of monitoring node signal values over time that represent a current operation of the cyber physical system; and a threat detection computer platform, coupled to the plurality of real-time monitoring nodes, to: receive the monitoring node signal values; compute an anomaly score; compare the anomaly score with an adaptive threshold; and detect that one of a particular monitoring node and a system is outside a decision boundary based on the comparison, and classify that particular monitoring node or system as anomalous. Numerous other aspects are provided.

Abbaszadeh, Masoud↗

Arctic Ocean Hydroacoustics

As the Arctic warms and loses its perennial ice cover, it is becoming more attractive for a variety of human uses. Hydroacoustic monitoring of this activity will grow in importance over the coming years and decades. Changes to the physical environment affect acoustic propagation and noise, with ramifications for our ability to detect and locate events and activities of interest. In this report, we use two long-term data sets from the Beaufort Sea, western Arctic Ocean, to determine how acoustic propagation conditions and seismic source detections are impacted by the changing environment: 1) oceanographic observations from ice-tethered profilers, and 2) passive acoustic recordings from a hydrophone. We find that changes to Beaufort Sea thermohaline stratification is stabilizing a subsurface duct, leading to more focused acoustic energy arrivals. Detections of catalogued submarine earthquakes show geographic differences in signal strength between seismic and acoustic waves. Signal strength increases with earthquake magnitude, but relationships to other source and path factors are less clear. Ambient noise also has clear seasonal patterns in the Arctic, with relatively low noise in the spring, higher noise near 1 Hz in summer, and higher noise near 10 Hz in winter. Climate change is expected to modify these seasonal noise patterns, impacting event detection. Future work will further investigate the mechanisms of ice effects on sound and couple acoustic modeling to an Earth System Model.

54 ENVIRONMENTAL SCIENCES↗

A Joint Search for the Electromagnetic Counterpart to the Gravitational-Wave Binary Black-Hole Merger Candidate S250328ae with the Dark Energy Camera and the Prime Focus Spectrograph

The first detection of an optical counterpart to a gravitational wave signal revealed that collaborative efforts between instruments with different specializations provide a unique opportunity to acquire impactful multi-messenger data. We present results of such a joint search with the Dark Energy Camera (DECam) and Prime Focus Spectrograph (PFS) for the optical counterpart of the LIGO-Virgo-KAGRA event S250328ae, a binary black hole merger candidate of high significance detected at a distance of 511$\pm$82 Mpc and localized within an area of 3 (15) square degrees at 50% (90%) confidence. We observed the 90% confidence area with DECam and identified 36 high-confidence transient candidates after image processing, candidate selection, and candidate vetting. We observed with PFS to obtain optical spectra of DECam candidates, Swift-XRT candidates, and potential host galaxies of S250328ae. In total, 3897 targets were observed by seven pointings covering ~50% of the 90% confidence area. After template fitting and visual inspection, we identified 12 SNe, 159 QSOs, 2975 galaxies, and 131 stars. With the joint observations of DECam and PFS, we found variability in 12 SNe, 139 QSOs, 37 galaxies, and 2 stars. We do not identify any confident optical counterparts, though the association is not ruled out for three variable candidates that are not observed by PFS and 6 QSO candidates without clear variability if the optical counterpart of S250328ae is faint. Despite the lack of confident optical counterparts, this paper serves as a framework for future collaborations between wide-field imagers and multi-object spectrographs to maximize multi-messenger analyses.

Zhang, Haibin [Natl. Astron. Observ. of Japan] (OR↗

Travelling wave‐based fault detection and location in a real low‐voltage DC microgrid

Abstract This paper discusses a device‐level implementation of a travelling wave (TW) protection device (PD) designed for a real low‐voltage DC microgrid. The TWPD fault detection and location algorithm is executed on a commercial digital signal processor (DSP) board, involving signal sampling at 1 MHz via the DSP board's analog‐to‐digital converter (ADC). The analogue input card measures positive pole, negative pole and pole‐to‐pole voltages at the TWPD location. Upon a successful fault detection using a second‐order high‐pass filter, the voltage data is normalised and multi‐resolution analysis (MRA) is performed on a 128‐sample buffer around the TW arrival time. MRA employs the discrete wavelet transform (DWT) to capture high‐frequency voltage patterns, and then the Parseval's energy theorem quantifies these TW characteristics by computing the energy of reconstructed wavelet coefficients. These energy values per decomposed frequency band are the basis for training a random forest classifier that predicts fault location and type. The TWPD is fully implemented and connected to a real DC microgrid in Albuquerque, NM, USA, for validation, and results are shown for field tests verifying the performance under faults.

Paruthiyil, Sajay Krishnan [Department of Electric↗

A method for infrared sensing based on oscillating zero power microelectromechanical photoswitches

This paper presents an interesting new method for measuring infrared (IR) radiation using a micromechanical photoswitch (MP). By leveraging the event-driven narrowband IR detection capability of an MP, electrostatic pull-in, and a novel integrated thermomechanical feedback mechanism, we show for the first time a zero-standby power IR sensor that can not only detect above-threshold IR power levels (>600 nW), but also generates an oscillating electromechanical pulse waveform whose frequency is a function of the incident IR power level. The device design, the theoretical model for the proposed idea, and the experimental demonstration of the mechanism are shown. The unique capability of zero-standby power IR detection and frequency-tunable AC waveform generation from a constant input signal (IR radiation) without the need for additional electronics promises to enable new functionalities for such remote wake-up sensors beyond simply detection, with potential uses in microrobotics and low-power computing.

Rajaram, Vageeswar (ORCID:0000000199546844)↗

FORTE Measurements of Global Optical Lightning Waveforms and Implications for Optical Lightning Detection

Lightning processes generate a diverse collection of optical pulses from current traversing the lightning channels. These signals are then broadened spatially and temporally via scattering in the clouds. The resulting waveforms measured from space with instruments like the photodiode detector (PDD) on the Fast On-orbit Recording of Transient Events (FORTE) satellite have a variety of shapes. In this study, we use coincident optical and Radio-Frequency measurements to document the properties of optical PDD waveforms associated with different types of lightning, estimate delays from scattering in the clouds, and comment on how pulse shape impacts optical lightning detection. We find that the attributes of optical pulses recorded by the PDD are consistent with prior studies, but vary globally and with event amplitude. The most powerful lightning tends to be single-peaked with faster rise times (median: ~100 µs) and shorter effective widths (median: ~400 µs) than normal lightning. Particularly dim events, meanwhile, include cases of broad optical waveforms with sustained optical emission throughout the PDD record, which the pixelated FORTE Lightning Location System (LLS) instrument has difficulty detecting. We propose that this is due to the optical signal being divided between individual LLS pixels that are each, individually, not bright enough to trigger. We use PDD waveforms and Monte Carlo radiative transfer modeling to demonstrate that increasing the temporal and spatial resolution of a pixelated lightning imager will make it more difficult to detect these broad/dim pulses as their energy becomes divided between additional pixels/integration frames.

54 ENVIRONMENTAL SCIENCES↗

Full phase space resonant anomaly detection

Physics beyond the Standard Model that is resonant in one or more dimensions has been a longstanding focus of countless searches at colliders and beyond. Recently, many new strategies for have been developed, where sideband information can be used in conjunction with modern machine learning, in order to generate synthetic datasets representing the Standard Model background. Until now, this approach was only able to accommodate a relatively small number of dimensions, limiting the breadth of the search sensitivity. Using recent innovations in point cloud generative models, we show that this strategy can also be applied to the full phase space, using all relevant particles for the anomaly detection. As a proof of principle, we show that the signal from the R&D dataset from the LHC Olympics is findable with this method, opening up the door to future studies that explore the interplay between depth and breadth in the representation of the data for anomaly detection. Published by the American Physical Society 2024

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗