Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Scan”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

H-alpha scans of the intergalactic H I cloud in Leo

Scans of H-alpha were obtained for two fields within the large, intergalactic H I cloud in Leo. The data provide a conservative upper limit of 1.7 x 10 to the -7th ergs/sq cm/s/sr on the H-alpha surface brightness of the cloud. This limit corresponds to an emission measure of less than 2 cm exp -6 pc for gas at a temperature of 10,000 K and implies an ionized hydrogen mass of less than 9 x 10 to the 9th f exp 1/2 solar mass within the cloud, where f is the filling fraction of the gas. This intensity may have important implications for possible sources of the ionization.

Reynolds, R. J.↗

Statistical dependency in visual scanning

A method to identify statistical dependencies in the positions of eye fixations is developed and applied to eye movement data from subjects who viewed dynamic displays of air traffic and judged future relative position of aircraft. Analysis of approximately 23,000 fixations on points of interest on the display identified statistical dependencies in scanning that were independent of the physical placement of the points of interest. Identification of these dependencies is inconsistent with random-sampling-based theories used to model visual search and information seeking.

Ellis, Stephen R.↗

A scanning modulation collimator observation of the high-energy X-ray source in the Crab Nebula

Two-dimensional maps of the 22-64 keV emission from the Crab Nebula with an angular resolution of 15 arcsec has been synthesized. The maps are generated by application of a maximum entropy method operating on a series of one-dimensional scans obtained with a balloon-borne modulation collimator telescope. The two-dimensional size, shape and orientation of the hard X-ray nebula relative to the pulsar have been measured for the first time. The implications of these results for models of electron transport in the Crab are discussed, and the geometry of the observed X-ray nebula is related to other features of the Crab Nebula system.

Pelling, R. M.↗

'Oxide-free' tip for scanning tunneling microscopy

A new tip for scanning tunneling microscopy and a tip repair procedure that allows one to reproducibly obtain atomic images of highly oriented pyrolytic graphite with previously inoperable tips are reported. The tips are shown to be relatively oxide-free and highly resistant to oxidation. The tips are fabricated with graphite by two distinct methods.

Colton, R. J.↗

Quantitative void characterization in structural ceramics by use of scanning laser acoustic microscopy

The ability of scanning laser acoustic microscopy (SLAM) to characterize artificially seeded voids in sintered silicon nitride structural ceramic specimens was investigated. Using trigonometric relationships and Airy's diffraction theory, predictions of internal void depth and size were obtained from acoustic diffraction patterns produced by the voids. Agreement was observed between actual and predicted void depths. However, predicted void diameters were generally much greater than actual diameters. Precise diameter predictions are difficult to obtain due to measurement uncertainty and the limitations of 100 MHz SLAM applied to typical ceramic specimens.

Roth, D. J.↗

High-speed assembly language (80386/80387) programming for laser spectra scan control and data acquisition providing improved resolution water vapor spectroscopy

An assembly language program using the Intel 80386 CPU and 80387 math co-processor chips was written to increase the speed of data gathering and processing, and provide control of a scanning CW ring dye laser system. This laser system is used in high resolution (better than 0.001 cm-1) water vapor spectroscopy experiments. Laser beam power is sensed at the input and output of white cells and the output of a Fabry-Perot. The assembly language subroutine is called from Basic, acquires the data and performs various calculations at rates greater than 150 faster than could be performed by the higher level language. The width of output control pulses generated in assembly language are 3 to 4 microsecs as compared to 2 to 3.7 millisecs for those generated in Basic (about 500 to 1000 times faster). Included are a block diagram and brief description of the spectroscopy experiment, a flow diagram of the Basic and assembly language programs, listing of the programs, scope photographs of the computer generated 5-volt pulses used for control and timing analysis, and representative water spectrum curves obtained using these programs.

Allen, Robert J.↗

Development of an electronically-scanned pressure module for operation at cryogenic temperatures

Pressure and temperature characteristics were measured for a number of multichannel electronically scanned pressure sensors. The tests were made on commercially available units designed to operate in a controlled temperature environment. Measurements of zero shift, sensitivity, and nonlinearity for each transducer were taken over a temperature range from 100 K to 340 K using a computer controlled data acquisition system. The units tested failed to meet accuracy specifications over the complete temperature range, which was expected. However, the sensors showed acceptable and predictable behavior over the temperature range from approximately -40 C (233 K) to 70 C (343 K). It was determined that a combination of local heating and accurate temperature monitoring can result in a device that can be compensated for temperature as well as its other physical properties. The design of a prototype for operation in a cryogenic environment is proposed, and a method for compensation is developed.

Johnson, Preston B.↗

Flaw characterization in structural ceramics using scanning laser acoustic microscopy

The ability of scanning laser acoustic microscopy (SLAM) to characterize artifically seeded voids in sintered silicon nitride structural ceramic specimens was investigated. The voids ranged from 20 to 430 microns in diameter and were embedded up to 2 mm beneath the surface of the specimens. Probability of detection was determined as a function of void depth and size. Trigonometric relationships and Airy's diffraction theory were used to obtain predictions of void depth and size from acoustic diffraction patterns produced by the voids. Agreement was observed between actual and predicted void depths. However, predicted void diameters were generally much greater than actual diameters. Precise diameter predictions are difficult to obtain because of measurement uncertainty and the limitations of the 100 MHz SLAM applied to typical ceramic specimens.

Roth, Don J.↗

In situ fatigue loading stage inside scanning electron microscope

A fatigue loading stage inside a scanning electron microscopy (SEM) was developed. The stage allows dynamic and static high-magnification and high-resolution viewing of the fatigue crack initiation and crack propagation processes. The loading stage is controlled by a closed-loop servohydraulic system. Maximum load is 1000 lb (4450 N) with test frequencies ranging up to 30 Hz. The stage accommodates specimens up to 2 inches (50 mm) in length and tolerates substantial specimen translation to view the propagating crack. At room temperature, acceptable working resolution is obtainable for magnifications ranging up to 10,000X. The system is equipped with a high-temperature setup designed for temperatures up to 2000 F (1100 C). The signal can be videotaped for further analysis of the pertinent fatigue damage mechanisms. The design allows for quick and easy interchange and conversion of the SEM from a loading stage configuration to its normal operational configuration and vice versa. Tests are performed entirely in the in-situ mode. In contrast to other designs, the NASA design has greatly extended the life of the loading stage by not exposing the bellows to cyclic loading. The loading stage was used to investigate the fatigue crack growth mechanisms in the (100)-oriented PWA 1480 single-crystal, nickel-based supperalloy. The high-magnification observations revealed the details of the crack growth processes.

Telesman, Jack↗

Direct control and characterization of a Schottky barrier by scanning tunneling microscopy

Scanning tunneling microscopy (STM) methods are used to directly control the barrier height of a metal tunnel tip-semiconductor tunnel junction. Barrier behavior is measured by tunnel current-voltage spectroscopy and compared to theory. A unique surface preparation method is used to prepare a low surface state density Si surface. Control of band bending with this method enables STM investigation of semiconductor subsurface properties.

Bell, L. D.↗

Multielement mapping of alpha-SiC by scanning Auger microscopy

Fine second-phase particles, numerous in sintered alpha-SiC, were analyzed by scanning Auger microscopy and conventional techniques. The Auger analysis utilized computer-controlled data acquisition, multielement correlation diagrams, and a high spatial resolution of 100 nm. This procedure enabled construction of false color maps and the detection of fine compositional details within these particles. Carbon, silicon oxide, and boron-rich particles (qualitatively as BN or B4C) predominated. The BN particles, sometimes having a carbon core, are believed to result from reaction between B4C additives and nitrogen sintering atmospheres.

Browning, Ray↗

Differential scanning calorimetric survey of brominated PAN, pitch-based and vapor-grown fibers

A differential scanning calorimetric survey of brominated PAN, pitch-based and vapor-grown fibers revealed that only vapor-grown fibers heat-treated to temperatures of 2250 C or above exhibited the phase change at 100 C associated with the two-dimensional melting of bromine, similar to that observed in HOPG. All the pitch-based fibers tested, as well as vapor-grown fibers annealed to 2250 C, showed a substantial decrease in resistivity upon bromination but gave no indication of a phase change, suggesting that the bromine in these fibers does not have the long-range order needed to undergo two-dimensional melting. The brominated PAN fibers and unannealed vapor-grown fibers showed no phase change and no change in resistivity, indicating that these fibers do not intercalate bromine.

Jaworske, D. A.↗

Scanning tunneling microscopy characterization of the geometric and electronic structure of hydrogen-terminated silicon surfaces

Scanning tunneling microscopy (STM) methods are used to characterize hydrogen-terminated Si surfaces prepared by a novel method. The surface preparation method is used to expose the Si-SiO2 interface. STM images directly reveal the topographic structure of the Si-SiO2 interface. The dependence of interface topography on oxide preparation conditions observed by STM is compared to the results of conventional surface characterization methods. Also, the electronic structure of the hydrogen-terminated surface is studied by STM spectroscopy. The near-ideal electronic structure of this surface enables direct tunnel spectroscopy measurements of Schottky barrier phenomena. In addition, this method enables probing of semiconductor subsurface properties by STM.

Kaiser, W. J.↗

The Mariner Mark II high precision scan actuator - Results of an options trade study covering pointing performance and system-wide impacts

Four actuators considered as candidates to meet the requirements of the Mariner Mark II high-precision scan platform are evaluated with respect to such criteria as the net effect on spacecraft mass, required power, cost, expected pointing performance, operational considerations, and necessary control complexity. A direct drive actuator is found to be the most suitable candidate. It is noted that for missions where reactionless actuation results in a lower spacecraft mass due to propellant savings, the option of using a platform mounted or spacecraft mounted reaction wheel for platform momentum compensation and spacecraft attitude control is attractive.

Schier, J. Alan↗

Performance of a scanning pencil-beam spaceborne scatterometer for ocean wind measurements

Simulation results show that a scatterometer design using two pencil beams scanning at different incidence angles measures the near-surface oceanic winds from a satellite better under most conditions than previous designs. The return signals from the ocean surface are much stronger than those from the fan beams used previously. Performance on a polar-orbiting satellite is compared with that of a fan beam spaceborne scatterometer. A wider and continuous swath is covered. The improvement in performance is higher at low wind speeds, so it is particularly suitable for measuring the low-mean-speed tropical wind fields. Performance on a low altitude tropic-orbiting platform such as the Space Station is also shown.

Moore, R. K.↗

A vector scanning processing technique for pulsed laser velocimetry

Pulsed laser sheet velocimetry yields nonintrusive measurements of two-dimensional velocity vectors across an extended planar region of a flow. Current processing techniques offer high precision (1 pct) velocity estimates, but can require several hours of processing time on specialized array processors. Under some circumstances, a simple, fast, less accurate (approx. 5 pct), data reduction technique which also gives unambiguous velocity vector information is acceptable. A direct space domain processing technique was examined. The direct space domain processing technique was found to be far superior to any other techniques known, in achieving the objectives listed above. It employs a new data coding and reduction technique, where the particle time history information is used directly. Further, it has no 180 deg directional ambiguity. A complex convection vortex flow was recorded and completely processed in under 2 minutes on an 80386 based PC, producing a 2-D velocity vector map of the flow field. Hence, using this new space domain vector scanning (VS) technique, pulsed laser velocimetry data can be reduced quickly and reasonably accurately, without specialized array processing hardware.

Wernet, Mark P.↗

Attitude angle effects on Nimbus-7 Scanning Multichannel Microwave Radiometer radiances and geophysical parameter retrievals

The attitude of the Nimbus-7 spacecraft has varied significantly over its lifetime. A summary of the orbital and long-term behavior of the attitude angles and the effects of attitude variations on Scanning Multichannel Microwave Radiometer (SMMR) brightness temperatures is presented. One of the principal effects of these variations is to change the incident angle at which the SMMR views the Earth's surface. The brightness temperatures depend upon the incident angle sensitivities of both the ocean surface emissivity and the atmospheric path length. Ocean surface emissivity is quite sensitive to incident angle variation near the SMMR incident angle, which is about 50 degrees. This sensitivity was estimated theoretically for a smooth ocean surface and no atmosphere. A 1-degree increase in the angle of incidence produces a 2.9 C increase in the retrieved sea surface temperature and a 5.7 m/sec decrease in retrieved sea surface wind speed. An incident angle correction is applied to the SMMR radiances before using them in the geophysical parameter retrieval algorithms. The corrected retrieval data is compared with data obtained without applying the correction.

Macmillan, Daniel S.↗

On the interpretation of integrated water vapor patterns in midlatitude cyclones derived from the Nimbus 7 scanning multichannel microwave radiometer

The present exploration of methods for the interpretation of the Nimbus 7 satellite's Scanning Multichannel Microwave Radiometer (SMMR) vapor patterns and the ways in which they relate to the dynamical structure of individual midlatitude storms employs gridded meteorological data from the First GARP Global Experiment special observing period in order to calculate diagnostic quantities. SMMR patterns for a storm at a weak stage determined from the diagnostic quantities are compared with SMMR patterns for the storm at a stronger stage. A more complete interpretation of the SMMR patterns emerges from these considerations.

Mcmurdie, Lynn A.↗