Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “STOPPING POWER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

Condition Monitoring of Wind Turbine Planetary Gearboxes Under Different Operating Conditions

Digitally enhanced services for wind power could reduce Operations and Maintenance (O&M) costs as well as the Levelised Cost Of Energy (LCOE). Therefore, there is a continuous need for advanced monitoring techniques which can exploit the opportunities of Internet of Things (IoT) and Big Data Analytics, revolutionizing the future of the energy sector. The heart of wind turbines is a rather complex epicyclic gearbox. Among others, extremely critical gearbox components which are often responsible for machinery stops are the rolling element bearings. The vibration signatures of bearings are rather weak compared to other components, such as gears, and as a result an extended number of signal processing techniques and tools have been proposed during the last decades, focusing towards accurate, early, and on time bearing fault detection with limited false alarms and missed detections. Envelope Analysis is one of the most important methodologies, where an envelope of the vibration signal is estimated usually after filtering around a frequency band excited by impacts due to the bearing faults. Different tools, such as Kurtogram, have been proposed in order to accurately select the optimum filter parameters (center frequency and bandwidth). Cyclic Spectral Correlation and Cyclic Spectral Coherence, based on Cyclostationary Analysis, have been proved as very powerful tools for condition monitoring. The monitoring techniques seem to have reached a mature level in case a machinery operates under steady speed and load. On the other hand, in case the operating conditions change, it is still unclear whether the change of the monitoring indicators is due to the change of the health of the machinery or due to the change of the operating parameters. Recently, the authors have proposed a new tool called IESFOgram, which is based on Cyclic Spectral Coherence and can automatically select the filtering band. Furthermore, the Cyclic Spectral Coherence is integrated along the selected frequency band leading to an Improved Envelope Spectrum. In this paper, the performance of the tool is evaluated and further extended on cases operating under different speeds and different loads. The effectiveness of the methodology is tested and validated on the National Renewable Energy Laboratory (NREL) wind turbine gearbox vibration condition monitoring benchmarking data set which includes various faults with different levels of diagnostic complexity as well as various speed and load operating conditions.

17 WIND ENERGY↗

ARE660 Wind Generator: Low Wind Speed Technology for Small Turbine Development

This project is for the design of a wind turbine that can generate most or all of the net energy required for homes and small businesses in moderately windy areas. The purpose is to expand the current market for residential wind generators by providing cost effective power in a lower wind regime than current technology has made available, as well as reduce noise and improve reliability and safety. Robert W. Preus’ experience designing and/or maintaining residential wind generators of many configurations helped identify the need for an improved experience of safety for the consumer. Current small wind products have unreliable or no method of stopping the wind generator in fault or high wind conditions. Consumers and their neighbors do not want to hear their wind generators. In addition, with current technology, only sites with unusually high wind speeds provide payback times that are acceptable for the on-grid user. Abundant Renewable Energy’s (ARE) basic original concept for the ARE660 was a combination of a stall controlled variable speed small wind generator and automatic fail safe furling for shutdown. The stall control for a small wind generator is not novel, but has not been developed for a variable speed application with a permanent magnet alternator (PMA). The fail safe furling approach for shutdown has not been used to our knowledge.

17 WIND ENERGY↗

Laser Wakefield Acceleration Driven by a CO2 Laser (STELLA-LW) - Final Report

The original goals of the Staged Electron Laser Acceleration – Laser Wakefield (STELLA-LW) program were to investigate two new methods for laser wakefield acceleration (LWFA). In pseudo-resonant LWFA (PR-LWFA), a laser pulse experiences nonlinear pulse steepening while traveling through the plasma. This steepening allows the laser pulse to generate wakefields even though the laser pulse length is too long for resonant LWFA to occur. For the conditions of this program, PR-LWFA requires a minimum laser peak power of 3 TW and a low plasma density (10^16 cm^-3). Seeded self-modulated LWFA (seeded SM-LWFA) combines LWFA with plasma wakefield acceleration (PWFA). An ultrashort (~100 fs) electron beam bunch acts as a seed in a plasma to form a wakefield via PWFA. This wakefield is subsequently amplified by the laser pulse through a self-modulated LWFA process. At least 1 TW laser power and, for a ~100-fs bunch, a plasma density ~10^17 cm^-3 are required. STELLA-LW was located on Beamline #1 at the Brookhaven National Laboratory (BNL) Accelerator Test Facility (ATF). The ATF TW CO2 laser served as the driving laser beam for both methods. For PR-LWFA, a single bunch was to probe the wakefield produced by the laser beam. For seeded SM-LWFA, the ATF linac would produce two bunches, where the first would be the seed and the second would be the witness. A chicane would compress the first bunch to enable it to generate wakefields via PWFA. The plasma source was a short-length, gas-filled capillary discharge with the laser beam tightly focused in the center of the capillary, i.e., no laser guiding was used, in order to obtain the needed laser intensity. During the course of the program, several major changes had to be made. First, the ATF could not complete the upgrade of the CO2 laser to the 3 TW peak power needed for the PR-LWFA experiment. Therefore, the PR-LWFA experiment had to be abandoned leaving only the seeded SM-LWFA experiment. Second, the ATF discovered that the chicane bifurcated the incoming bunch into two compressed bunches separated in time and energy. With the available equipment it was not possible to stop the bifurcation. In an attempt to still deliver a single compressed bunch to the experiment, a slit was used to block one of the bunches, but this also blocked any witness bunch. Third, the loss of the witness bunch meant a different method for detecting the effect of the laser beam on the wakefield had to be implemented. Hence, a coherent Thomson scattering (CTS) diagnostic was designed and assembled. Unfortunately, further tests with blocking one of the double-bunches showed that wakefield generation was too unstable and difficult to control for the seeded SM-LWFA experiment. Luckily, it was found that a fast-rising (~50 fs) bunch could be created along Beamline #2 that was capable of generating wakefields, did not use the chicane, and was more stable. Thus, as the fourth major change, the entire STELLA-LW apparatus, including the CTS diagnostic, was moved from Beamline #1 to Beamline #2. Because this move occurred near the end of the program, only a single 2-week run could be performed. During the run it was found the laser beam transmission through the capillary discharge was severely degraded when the plasma was on. This loss of transmission appeared to be due to defocusing of the laser beam probably caused by laser-induced ionization creating a lens effect inside the capillary. Defocusing could also cause laser light to strike the capillary wall, thereby producing ablation and localized changes in the plasma density. Any changes in the plasma density would disrupt the plasma resonance condition for the wakefield. It was also discovered after the run that the ATF laser was producing multiple output pulses. The leading pulse could have caused ionization that interfered with transmission of the following pulses. Worse yet, the peak power in each of the pulses was several times smaller than if all the pulse energy was in a single pulse. This meant each pulse had less than 1 TW power. Wakefield formation with no laser beam present was confirmed by observing energy loss of the fast-raising seed bunch passing through the capillary discharge. When the laser beam was sent into the plasma, no CTS signal was detected, probably due to defocusing of the laser light, changes in the plasma density due to laser-induced ionization, and insufficient peak power in the individual pulses. It is for these reasons we were not able to validate the seeded SM-LWFA predictions. In summary, the STELLA-LW experiment was not able to demonstrate seeded SM-LWFA or PR-LWFA primarily because of limitations of the ATF CO2 laser, both in its deliverable peak power and its ability to provide a single laser pulse.

43 PARTICLE ACCELERATORS↗

Error Analysis of ZFP Compression for Floating-Point Data

Compression of floating-point data will play an important role in high-performance computing as data bandwidth and storage become dominant costs. Lossy compression of floating-point data is powerful, but theoretical results are needed to bound its errors when used to store look-up tables, simulation results, or even the solution state during the computation. In this paper, we analyze the round-off error introduced by ZFP, a lossy compression algorithm. Here, the stopping criteria for ZFP depends on the compression mode specified by the user: fixed rate, fixed accuracy, or fixed precision [P. Lindstrom, ZFP 0.5.3 Documentation, 2018]. While most of our discussion is focused on the fixed precision mode of ZFP, we establish a bound on the error introduced by all three compression modes. In order to tightly capture the error, first we introduce a vector space that allows us to work with binary representations of components. Under this vector space, we define operators that implement each step of the ZFP compression and decompression to establish a bound on the error caused by ZFP. To conclude, numerical tests are provided to demonstrate the accuracy of the established bounds.

97 MATHEMATICS AND COMPUTING↗

Fast Reactor Subassembly Design Modifications for Increasing Electricity Generation Efficiency

Suggested for Track 7: Advances in Reactor Core Design and In-Core Management _____________________________________________________________________________________ Fast Reactor Subassembly Design Modifications for Increasing Electricity Generation Efficiency R. Wigeland and K. Hamman Idaho National Laboratory Given the ability of fast reactors to effectively transmute the transuranic elements as are present in spent nuclear fuel, fast reactors are being considered as one element of future nuclear power systems to enable continued use and growth of nuclear power by limiting high-level waste generation. However, a key issue for fast reactors is higher electricity cost relative to other forms of nuclear energy generation. The economics of the fast reactor are affected by the amount of electric power that can be produced from a reactor, i.e., the thermal efficiency for electricity generation. The present study is examining the potential for fast reactor subassembly design changes to improve the thermal efficiency by increasing the average coolant outlet temperature without increasing peak temperatures within the subassembly, i.e., to make better use of current technology. Sodium-cooled fast reactors operate at temperatures far below the coolant boiling point, so that the maximum coolant outlet temperature is limited by the acceptable peak temperatures for the reactor fuel and cladding. Fast reactor fuel subassemblies have historically been constructed using a large number of small diameter fuel pins contained within a tube of hexagonal cross-section, or hexcan. Due to this design, there is a larger coolant flow area next to the hexcan wall as compared to flow area in the interior of the subassembly. This results in a higher flow rate near the hexcan wall, overcooling the fuel pins next to the wall, and a non-uniform coolant temperature distribution. It has been recognized for many years that this difference in sodium coolant temperature was detrimental to achieving greater thermal efficiency, since it causes the fuel pins in the center of the subassembly to operate at higher temperatures than those near the hexcan walls, and it is the temperature limit(s) for those fuel pins that limits the average coolant outlet temperature. Fuel subassembly design changes are being investigated using computational fluid dynamics (CFD) to quantify the effect that the design changes have on reducing the intra-subassembly coolant flow and temperature distribution. Simulations have been performed for a 19-pin test subassembly geometry using typical fuel pin diameters and wire wrap spacers. The results have shown that it may be possible to increase the average coolant outlet temperature by 20 C or more without changing the peak temperatures within the subassembly. These design changes should also be effective for reactor designs using subassemblies with larger numbers of fuel pins. R. Wigeland, Idaho National Laboratory, P.O. Box 1625, Mail Stop 3860, Idaho Falls, ID, U.S.A., 83415-3860 email – roald.wigeland@inl.gov fax (U.S.) – 208-526-2930

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

SU-E-J-162: Quality Assurance Procedures for MR Guided Focused Ultrasound Treatment of Bone Metastasis

Purpose: The purpose of this work is to develop and verify our quality assurance (QA) procedures to ensure the safety and efficacy of MR-guided focused ultrasound (MRgFUS) treatment of bone metastases. Methods: A practical QA program was developed. Monthly and daily QA (DQA) procedures were performed. The major QA items included the checks of the machine hardware, software and patient safety features. Briefly, these checks/tests include: 1) the cooling system reservoir and treatment table; 2) power to the treatment table; 3) the MR coil; 4) the transducer position with MRI; 5) image display on the treatment work station; 6) the effective focal spot in 3 directions using MR thermometry; and 7) all the safety devices including a sonication lamp, and the emergency stop-sonication switches. In order to avoid patient skin burn, it is important to remove gas bubbles in the interfaces between the treatment table and the gel pad, and the gel pad and patients skin during the patient setup. Our QA procedures have been verified and evaluated through patient treatments. Seven patients with scapula, humeral head, sacrum, ilium, pubic ramus and acetabular bone metastases were treated using MRgFUS. Results: Our study showed that all seven patients tolerated the MRgFUS treatment well. No skin toxicity or other complications were observed. The pain score (0–10) using the visual analog scale (VAS) was significantly reduced from 8.0 ± 1.1 before treatment to 4.7 ± 3.0, 3.0 ± 1.5, 3.2 ± 2.8 and 3.4 ± 1.5 at one day, one month, two months and three months after the MRgFUS treatment, respectively. Conclusion: We demonstrated that with the appropriate QA procedures, MRgFUS is a safe, effective and noninvasive treatment modality for palliation of bone metastases.

60 APPLIED LIFE SCIENCES↗

Circuit Stops Prelasing In A Q-Switched Laser

Protective shutdown circuit stops prelasing in Q-switched laser operating at pulse-repetition rate of about 10 Hz. During normal operation, Q-switch prevents emission of light from laser cavity during application of Q-switch-trigger pulse. When circuit detects prelasing, it triggers relay turning off laser power supply. Circuit integrated into almost any Q-switched-laser system, provided one gains access to laser light, Q-switch-trigger pulse, and safety-interlock line of laser power supply.

Lockard, George E.↗

Plasma Reactor Modeling and Validation Experiments

Plasma processing is a key processing stop in integrated circuit manufacturing. Low pressure, high density plum reactors are widely used for etching and deposition. Inductively coupled plasma (ICP) source has become popular recently in many processing applications. In order to accelerate equipment and process design, an understanding of the physics and chemistry, particularly, plasma power coupling, plasma and processing uniformity and mechanism is important. This understanding is facilitated by comprehensive modeling and simulation as well as plasma diagnostics to provide the necessary data for model validation which are addressed in this presentation. We have developed a complete code for simulating an ICP reactor and the model consists of transport of electrons, ions, and neutrals, Poisson's equation, and Maxwell's equation along with gas flow and energy equations. Results will be presented for chlorine and fluorocarbon plasmas and compared with data from Langmuir probe, mass spectrometry and FTIR.

Meyyappan, M.↗

Floating Potential Probe Deployed on the International Space Station

In the spring and summer of 2000, at the request of the International Space Station (ISS) Program Office, a Plasma Contactor Unit Tiger Team was set up to investigate the threat of the ISS arcing in the event of a plasma contactor outage. Modeling and ground tests done under that effort showed that it is possible for the external structure of the ISS to become electrically charged to as much as -160 V under some conditions. Much of this work was done in anticipation of the deployment of the first large ISS solar array in November 2000. It was recognized that, with this deployment, the power system would be energized to its full voltage and that the predicted charging would pose an immediate threat to crewmembers involved in extravehicular activities (EVA's), as well as long-term damage to the station structure, were the ISS plasma contactors to be turned off or stop functioning. The Floating Potential Probe was conceived, designed, built, and deployed in record time by a crack team of scientists and engineers led by the NASA Glenn Research Center in response to ISS concerns about crew safety.

Ferguson, Dale C.↗

Sub-Seabed Repository for Nuclear Waste - a Strategic Alternative - 13102

It was recognized at the outset of nuclear power generation in the 1950's that the waste products would require isolation away from humans for periods in excess of 10,000 years. After years studying alternatives, the DOE recommended pursuing the development of a SNF/HLW disposal facility within Yucca Mountain in the desert of Nevada. That recommendation became law with passage of the NWPAA, effectively stopping development of other approaches to the waste problem. In the face of political resistance from the state of Nevada, the 2010 decision to withdraw the license application for the geologic repository at Yucca Mountain has delayed further the most mature option for safe, long-term disposal of SNF and HLW. It is time to revisit an alternative option, sub-seabed disposal within the US Exclusive Economic Zone (EEZ), which would permanently sequester waste out of the biosphere, and out of the reach of saboteurs or terrorists. A proposal is made for a full scale pilot project to demonstrate burying radioactive waste in stable, deep ocean sediments. While much of the scientific work on pelagic clays has been done to develop a sub-seabed waste sequestration capability, this proposal introduces technology from non-traditional sources such as riser-less ocean drilling and the Navy's Sound Surveillance System. The political decisions affecting the issue will come down to site selection and a thorough understanding of comparative risks. The sub-seabed sequestration of nuclear waste has the potential to provide a robust solution to a critical problem for this clean and reliable energy source. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Controlling a Four-Quadrant Brushless Three-Phase dc Motor

Control circuit commutates windings of brushless, three-phase, permanent-magnet motor operating from power supply. With single analog command voltage, controller makes motor accelerate, drive steadily, or brake regeneratively, in clockwise or counterclockwise direction. Controller well suited for use with energy-storage flywheels, actuators for aircraft-control surfaces, cranes, industrial robots, and other electromechanical systems requiring bidirectional control or sudden stopping and reversal.

Nola, F. J.↗

Grassy ELM regime at low pedestal collisionality in high-power tokamak plasma

Spontaneous mitigation of giant ELMs and appearance of grassy ELMs have been observed repeatedly at low pedestal collisionality (${\nu }_{\mathrm{e},\mathrm{p}\mathrm{e}\mathrm{d}}^{{\ast}}\sim 0.15$) in the high-power (P inj > 13 MW) hybrid scenario in DIII-D. Higher β p and higher q 95 appear to be beneficial to achieving the grassy ELM regime. The grassy ELM H-mode plasma shows high energy confinement performance (H 98y2 up to over 1.5) under the conditions of high neutral beam torque and high core rotation. The pedestal width appears to exceed the EPED1.0 model prediction by more than 50%. Pedestal stability analysis performed with the ELITE code indicates that the stability against low-n kink/peeling modes is improved with increased auxiliary heating power and the operational point in the grassy ELM regime is located near the ballooning boundary. The pedestal stability characteristics during the grassy ELM crashes have been investigated in comparison with the giant ELM crashes based on plasma profiles experimentally measured with high resolution and accuracy. It has been found that the underlying mechanism for the observed small-amplitude ELM crashes is mainly the expansion of the ballooning stability boundary induced by an initial radially localized collapse in the pedestal, which helps to stop the growth of instabilities and further collapse of the pedestal. The effect of electron density pedestal on mitigating edge localized instabilities has been analyzed by numerical simulation, suggesting that the electron density pedestal characterized by high n e,sep /n e,ped and low density gradient helps to stabilize peeling-ballooning modes because of a low pressure pedestal gradient and to lower the ballooning boundary mainly because of a low ion diamagnetic frequency in the pedestal region, thus triggering ballooning instabilities and producing the intrinsic grassy ELMs. Numerical simulation of the Chinese fusion engineering test reactor (CFETR) with the SOLPS code indicates that the separatrix density might be insensitive to the electron diffusivity in the pedestal region and increase with the power flowing from the core region to the edge region. Furthermore, pedestal stability analysis suggests that the flat density pedestal with high separatrix density obtained in the high-power plasma in CFETR would make the operational point close to the ballooning boundary, which is considered to help destabilize ballooning instabilities and facilitate the access to the grassy ELM regime.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Design of a PIP-II Era Mu2e Experiment

We propose a design of an upgraded Mu2e experiment for the future Fermilab PIP-II era based on the muon collider front end. The consensus is that such an upgrade should provide a factor of 10 increase in the rate of stopping muons in the experimental target. The current Mu2e design is optimized for 8 kW of protons at 8 GeV. The PIP-II upgrade project is a 250-meter-long CW linac capable of accelerating a 2-mA proton beam to a kinetic energy of 800 MeV (total power 1.6 MW). This would significantly improve the Fermilab proton source to enable next-generation intensity frontier experiments. But using this 800 MeV beam poses challenges to the Mu2E experiment. Bright muon beams generated from sources designed for muon collider and neutrino factory facilities have been shown to generate two orders of magnitude more muons per proton than the current Mu2e production target and solenoid. In contrast to the current Mu2e, the muon collider design has forward-production of muons from the target.

43 PARTICLE ACCELERATORS↗

A cryogenically cooled, multidetector spectrometer for infrared astronomy

A liquid helium-cooled, 24 detector grating spectrometer was developed and used for low resolution astronomical observations in the 5 to 14 micron spectral range. The instrument operated on the 91 cm Kuiper Airborne Observatory, the 3 m IRTF (Mauna Kea), the 3 m Shane telescope Observatory, the 3 m Shane telescope (Lick Observatory), and the 152 cm NASA and University of Arizona telescope. The detectors are discrete Si:Bi photoconductors with individual metal oxide semiconductor field effect transistor preamplifiers operating at 4 K. The system uses a liquid helium-cooled slit, order-sorter filter, collimator mirror, grating, and camera mirror arranged in a Czerny-Turner configuration with a cold stop added between the collimator mirror and the grating. The distances between components are chosen so that the collimator mirror images the secondary mirror of the telescope onto the cold stop, thus providing a very effective baffle. Scattered radiation is effectively reduced by using liquid helium-cooled, black baffles to divide the spectrometer into three separate compartments. The system noise-equivalent flux density, when used on the 152 cm telescope from 8 to 13 microns with a resolving power of 50, is 4.4 x 10 to the minus 17th power W/sq cm micron square root of Hz. The main applications are for measuring continuum radiation levels and solid state emission and absorption features in regions of star and planet formation.

Witteborn, F. C.↗

A cryogenically cooled, multidetector spectrometer for infrared astronomy

A liquid helium-cooled, 24 detector grating spectrometer was developed and used for low resolution astronomical observations in the 5 to 14 micron spectral range. The instrument operated on the 91 cm Kuiper Airborne Observatory, the 3 m IRTF (Mauna Kea), the 3 m Shane telescope (Lick Observatory), and the 152 cm NASA and University of Arizona telescope. The detectors are discrete Si:Bi photoconductors with individual metal oxide semiconductor field effect transistor preamplifiers operating at 4 K. The system uses a liquid helium-cooled slit, order-sorter filter, collimator mirror, grating, and camera mirror arranged in a Czerny-Turner configuration with a cold stop added between the collimator mirror and the grating. The distances between components are chosen so that the collimator mirror images the secondary mirror of the telescope onto the cold stop, thus providing a very effective baffle. Scattered radiation is effectively reduced by using liquid helium-cooled, black baffles to divide the spectrometer into three separate compartments. The system noise-equivalent flux density, when used on the 152 cm telescope from 8 to 13 microns with a resolving power of 50, is 4.4 x 10 to the minus 17th power W/sq cm micron square root of Hz. The main applications are for measuring continuum radiation levels and solid state emission and absorption features in regions of star and planet formation.

Witteborn, F. C.↗

The linear polarization of 3C 345 in the ultraviolet

The linear polarization of 3C 345, a superluminal radio source and OVV quasar, was observed in two bandpasses in the ultraviolet (centered at 2160 A and 2770 A) in 1993 April using the High Speed Photometer on the Hubble Space Telescope. The quasar is significantly polarized in the UV (p greater than 5%). Ground-based polarimetry was obtained 11 days later, but a difference in the position angle between the observations in the visible and those in the UV indicate that the magnitude of the polarization of 3C 345 may have changed over that time. If the two observation sets represent the same state of spectral polarization, then the large UV flux implies that either the polarization of the synchrotron continuum must stop decreasing in the UV, or that there is an additional source of polarized flux in the ultraviolet. Only if the UV observations represent a spectral polarization state with the same position angle in the visible seen previously in 3C 345 can the polarized flux be represented by a single power law consistent with the three-component model of Smith et al. This model consists of a polarized synchrotron component, an unpolarized component from the broad-line region, and an unpolarized component attributed to thermal radiation from an optically thick accretion disk. Additional simultaneous polarimetry in the UV and visible will be required to further constrain models of the continuum emission processes in 3C 345 and determine if the UV polarized flux is synchrotron in origin.

Dolan, Joseph F.↗

Circuit for Full Charging of Series Lithium-Ion Cells

An advanced charger has been proposed for a battery that comprises several lithium-ion cells in series. The proposal is directed toward charging the cells in as nearly an optimum manner as possible despite unit-to-unit differences among the nominally identical cells. The particular aspect of the charging problem that motivated the proposal can be summarized as follows: During bulk charging (charging all the cells in series at the same current), the voltages of individual cells increase at different rates. Once one of the cells reaches full charge, bulk charging must be stopped, leaving other cells less than fully charged. To make it possible to bring all cells up to full charge once bulk charging has been completed, the proposed charger would include a number of top-off chargers one for each cell. The top-off chargers would all be powered from the same DC source, but their outputs would be DC-isolated from each other and AC-coupled to their respective cells by means of transformers, as described below. Each top-off charger would include a flyback transformer, an electronic switch, and an output diode. For suppression of undesired electromagnetic emissions, each top-off charger would also include (1) a resistor and capacitor configured to act as a snubber and (2) an inductor and capacitor configured as a filter. The magnetic characteristics of the flyback transformer and the duration of its output pulses determine the energy delivered to the lithium-ion cell. It would be necessary to equip the cell with a precise voltage monitor to determine when the cell reaches full charge. In response to a full-charge reading by this voltage monitor, the electronic switch would be held in the off state. Other cells would continue to be charged similarly by their top-off chargers until their voltage monitors read full charge.

Ott, William E.↗

Improving Single Event Effects Testing Through Software

Radiation encountered in space environments can be damaging to microelectronics and potentially cause spacecraft failure. Single event effects (SEE) are a type of radiation effect that occur when an ion strikes a device. Single event gate rupture (SEGR) is a type of SEE that can cause failure in power transistors. Unlike other SEE rates in which a constant linear energy transfer (LET) can be used, SEGR rates sometimes require a non-uniform LET to be used to be accurate. A recent analysis shows that SEGR rates are most easily calculated when the environment is described as a stopping rate per unit volume for each ion species. Stopping rates in silicon for pertinent ions were calculated using the Stopping and Range of Ions in Matter (SRIM) software and CREME-MC software. A reference table was generated and can be used by others to calculate SEGR rates for a candidate device. Additionally, lasers can be used to simulate SEEs, providing more control and information at lower cost than heavy ion testing. The electron/hole pair generation rate from a laser pulse in a semiconductor can be related to the LET of an ion. MATLAB was used to generate a plot to easily make this comparison.

generation equation↗