Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SCANNING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

Low noise, low heat dissipation, high gain AC-DC front end amplification for scanning probe microscopy.

We report here on the design, construction and testing of a vacuum compatible AC-DC amplification system for low signal measurements with scanning probes. The most important feature of this new amplification system is incorporated within the head of a scanning tunneling microscope (STM). This is achieved with a very low thermal dissipation radio frequency amplifier at the STM head. The amplifier gain is higher than 40 dB and has a 50 dB maximum. Further, the AC noise figure is 0.7 dB between 100 and 1000 MHz. The noise induced in the DC amplifier is less than 2 pA RMS (root mean square), which enables the microscope to scan over soft insulating molecular layers. Thermal drift at the STM tip-sample interface is below 0.1 nm min{sup -1} both in air and in vacuum operation. Atomic resolution on highly oriented pyrolytic graphite surfaces is reliably achieved. Spin noise measurements are provided as an example of an application.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Density functional methods for the magnetism of transition metals: SCAN in relation to other functionals

We report tests of various density functionals for ferromagnetic Fe, Co, and Ni with a focus on characterizing the behavior of the so-called strongly constrained and appropriately normed (SCAN) functional. It is found that SCAN is closer in behavior to functionals that yield localized behavior, such as hybrid functionals, than other semilocal functionals that are tested. The results are understood in terms of a tendency to differentiate orbitals, favoring integer occupation, which is necessary for a correct description of atomic systems, but inappropriate for the open shell metallic ferromagnetic metals studied here. Not only is the exchange splitting for open shells enhanced with SCAN, but also as seen in Ni, there is much more band dependence with significantly more overestimation for bands corresponding to the partially filled orbitals.

36 MATERIALS SCIENCE↗

Three Photon Excited Image Scanning Microscopy for in-Depth Super-Resolution Studies of Biological Samples

Multiphoton laser scanning microscopy is a powerful tool for deep imaging of thick biological samples. Image scanning microscopy (ISM) has demonstrated significant improvements in the signal-to-noise ratio in confocal laser scanning microscopy, while at the same time improving upon the effectively attainable resolution. Two-photon excitation (2PE), combined with ISM, has been shown to allow for deep tissue imaging with enhanced resolution compared to 2PE microscopy. Three-photon excitation (3PE) has enabled record imaging depth and contrast for multiphoton imaging, due to the superior suppression of out-of-focus signal generation. In this paper, we demonstrate super-resolution 3PE ISM. This is achieved using a single-photon avalanche detector array, and 1040-nm pulses for 3PE of blue fluorescence. This method enables subdiffraction limited resolution imaging of biological samples stained with blue fluorescent markers, such as mouse myocardial and spinal cord tissues stained with 4 ′ , 6 -diamidino-2-phenylindole. Deconvolution improves the resolving power further and allows for imaging with better than λ / 8 resolution with respect to the 3PE wavelength λ . With the ISM pixel reassignment procedure, we demonstrate a resolution enhancement of ∼ 1.6 laterally, compared to the resolution attained using a photomultiplier tube in a non-descanned detection arrangement, and a factor of ∼ 1.8 enhancement in axial resolution. The experimentally measured three-dimensional point spread function volume is shrunk ∼ 4.4 -fold, which is close to the theoretically expected enhancement. Published by the American Physical Society 2024

47 OTHER INSTRUMENTATION↗

A new synchrotron rapid-scanning X-ray fluorescence (SRS-XRF) imaging station at SSRL beamline 6-2

This paper describes a new large-range rapid-scan X-ray fluorescence (XRF) imaging station at beamline 6-2 at the Stanford Synchrotron Radiation Lightsource at SLAC National Accelerator Laboratory. This station uses a continuous rapid-scan system with a scan range of 1000 × 600 mm and a load capacity of up to 25 kg, capable of 25–100 µm resolution elemental XRF mapping and X-ray absorption spectroscopy (XAS) of a wide range of objects. XRF is measured using a four-element Hitachi Vortex ME4 silicon drift detector coupled to a Quantum Detectors Xspress3 multi-channel analyzer system. A custom system allows the X-ray spot size to be changed quickly and easily via pinholes ranging from 25 to 100 µm, and the use of a poly-capillary or axially symmetric achromatic optic may achieve a <10 µm resolution in the future. The instrument is located at wiggler beamline 6-2 which has an energy range of 2.1–17 keV, creating K emission for elements up to strontium, and L or M emission for all other elements. XAS can also be performed at selected sample positions within the same experiment, allowing for a more detailed chemical characterization of the elements of interest. Furthermore, sparse excitation energy XRF imaging can be performed over a wide range of incident X-ray energies. User friendliness has been emphasized in all stages of the experiment, including versatile sample mounts, He purged chambers for low- Z analyses, and intuitive visualization hardware and software. The station provides analysis capabilities for a wide range of materials and research fields including biological, chemical, environmental and materials science, paleontology, geology and cultural heritage.

47 OTHER INSTRUMENTATION↗

Spot pattern welding scanning strategy for sensor embedding and residual stress reduction in laser-foil-printing additive manufacturing

Here, this paper aims to present spot pattern welding (SPW) as a scanning strategy for laser-foil-printing (LFP) additive manufacturing (AM) in place of the previously used continuous pattern welding (CPW) (line-raster scanning). The SPW strategy involves generating a sequence of overlapping spot welds on the metal foil, allowing the laser to form dense and uniform weld beads. This in turn reduces thermal gradients, promotes material consolidation and helps mitigate process-related risks such as thermal cracking, porosity, keyholing and Marangoni effects. 304L stainless steel (SS) feedstock is used to fabricate test specimens using the LFP system. Imaging techniques are used to examine the melt pool dimensions and layer bonding. In addition, the parts are evaluated for residual stresses, mechanical strength and grain size. Compared to CPW, SPW provides a more reliable heating/cooling relationship that is less dependent on part geometry. The overlapping spot welds distribute heat more evenly, minimizing the risk of elevated temperatures during the AM process. In addition, the resulting dense and uniform weld beads contribute to lower residual stresses in the printed part. To the best of the authors’ knowledge, this is the first study to thoroughly investigate SPW as a scanning strategy using the LFP process. In general, SPW presents a promising strategy for securing embedded sensors into LFP parts while minimizing residual stresses.

36 MATERIALS SCIENCE↗

A new gamma-ray detector, 3-dimension, fast scanning table for pulse-shape analysis

The state-of-the art gamma-ray spectrometers such as AGATA and GRETA are using position sensitive multi-segmented HPGe crystals. Pulse-shape analysis (PSA) allows to retrieve the localisation of the gamma interactions and to perform gamma-ray tracking within germanium. The precision of the localisation depends on the quality of the pulse-shape database used for comparison. The IPHC laboratory developed a new fast scanning table allowing to measure experimental pulse shapes in the whole volume of any crystal. The results of the scan of an AGATA 36-fold segmented tapered coaxial detector are shown here, 48580 experimental pulse shapes are extracted within 2 weeks of scanning. These data will contribute to AGATA PSA performances, but have also applications for gamma cameras or Compton-suppressed detectors. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Divide and conquer: using RhizoVision Explorer to aggregate data from multiple root scans using image concatenation and statistical methods

Roots are important in agricultural and natural systems for determining plant productivity and soil carbon inputs. Sometimes, the amount of roots in a sample is too much to fit into a single scanned image, so the sample is divided among several scans, and there is no standard method to aggregate the data. Here, we describe and validate two methods for standardizing measurements across multiple scans: image concatenation and statistical aggregation. We developed a Python script that identifies which images belong to the same sample and returns a single, larger concatenated image. These concatenated images and the original images were processed with RhizoVision Explorer, a free and open-source software. An R script was developed, which identifies rows of data belonging to the same sample and applies correct statistical methods to return a single data row for each sample. These two methods were compared using example images from switchgrass, poplar, and various tree and ericaceous shrub species from a northern peatland and the Arctic. Most root measurements were nearly identical between the two methods except median diameter, which cannot be accurately computed by statistical aggregation. We believe the availability of these methods will be useful to the root biology community.

59 BASIC BIOLOGICAL SCIENCES↗

Ultrafast method for scanning tunneling spectroscopy

A scanning tunneling microscope (STM) combines unique capabilities in imaging and spectroscopy with atomic precision, and it can obtain energy-resolved spectroscopic data with atomic resolution. In this paper, we utilize a recently proposed modification to the STM feedback control loop to acquire high quality d 2 I/dV 2 images. We have developed a constant differential conductance imaging method by closing the STM feedback loop with a high precision dI/dV measurement. In this mode, the tip’s vertical position is adjusted so as to keep the differential conductance constant during raster scanning of the surface. Based on this imaging mode, we propose a new technique to acquire fast and reliable scanning tunneling spectroscopy (STS) data simultaneously with the imaging.

47 OTHER INSTRUMENTATION↗

X-Ray Scan Detection for Cargo Integrity

ABSTRACT The increase of terrorism and its global impact has made the determination of the contents of cargo containers a necessity. Existing technology allows non-intrusive inspections to determine the contents of a container rapidly and accurately. However, some cargo shipments are exempt from such inspections. Hence, there is a need for a technology that enables rapid and accurate means of detecting whether such containers were non-intrusively inspected. Non-intrusive inspections are most commonly performed utilizing high powered X-ray equipment. The challenge is creating a device that can detect short duration X-ray scans while maintaining a portable, battery powered, low cost, and easy to use platform. The Pacific Northwest National Laboratory (PNNL) has developed a methodology and prototype device focused on this challenge. The prototype, developed by PNNL, is a battery powered electronic device that continuously measures its X-ray and Gamma exposure, calculates the dose equivalent rate, and makes a determination of whether the device has been exposed to the amount of radiation experienced during an X-ray inspection. Once an inspection is detected, the device will record a timestamp of the event and relay the information to authorized personnel via a visual alert, USB connection, and/or wireless communication. The results of this research demonstrate that PNNL’s prototype device can be effective at determining whether a container was scanned by X-ray equipment typically used for cargo container inspections. This paper focuses on laboratory measurements and test results acquired with the PNNL prototype device using several X-ray radiation levels. Keywords: Radiation, Scan, X-ray, Gamma, Detection, Cargo, Container, Wireless, RF

Valencia, Juan D.↗

A short-scan reconstruction for cone-beam CT using shift-invariant FBP and equal weighting

A 3D reconstruction formula has been derived for a circular cone-beam (CB) short scan using 1D shift-invariant filtering, CB backprojection, and equal weighting. By first converting the divergent projections to parallel projections, we analyze the circular CB data using the classic central slice theorem. The sampling density in Fourier space is investigated and 1D shift-invariant filtering before backprojection can be used to compensate for the nonuniformity. The final formula consists of a conventional FDK reconstruction and a correction term using differential backprojection and the 1D Hilbert transform in the image domain. On a full scan, the approach reduces to the FDK algorithm, while for a short scan, the CB artifacts are suppressed by the second term. This algorithm outperforms the modified FDK algorithm with Parker's weighting, as illustrated by computer simulations and experimental results. Due to its shift-invariant filtered-backprojection structure, the proposed algorithm is implemented efficiently, and requires a simple adaptation of the FDK algorithm.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Radiochromic film dosimetry: Reflection vs transmission scanning

The objective of this study was to compare the transmission and the reflection scanning reading modes of radiochromic MD-55 films of a document scanner. The use of the red channel of the red-green-blue images results in measurement accuracy that did not differ between the two reading modes. On the other hand, the scanner uniformity and temporal stability, the long-term stability of the film readings and the dynamic range is superior using the reflection mode. The dynamic range of dose measurements can be extended up to least 500 Gy using the alternative color channels by both reading techniques. Similar backscattering dose factors close to high Z inhomogeneities were found using both scanning modes. In conclusion, the use of reflection scanning mode of MD55 films was superior to the traditionally used transmission mode.

61 RADIATION PROTECTION AND DOSIMETRY↗

On the uncertainties in effective dose estimates of adult CT head scans

Estimates of the effective dose to adult patients from computed tomography (CT) head scanning can be calculated using a number of different methods. These estimates can be used for a variety of purposes, such as improving scanning protocols, comparing different CT imaging centers, and weighing the benefits of the scan against the risk of radiation-induced cancer. The question arises: What is the uncertainty in these effective dose estimates? This study calculates the uncertainty of effective dose estimates produced by three computer programs (CT-EXPO, CTDosimetry, and ImpactDose) and one method that makes use of dose-length product (DLP) values. Uncertainties were calculated in accordance with an internationally recognized uncertainty analysis guide. For each of the four methods, the smallest and largest overall uncertainties (stated at the 95% confidence interval) were: 20%-31% (CT-EXPO), 15%-28% (CTDosimetry), 20%-36% (ImpactDose), and 22%-32% (DLP), respectively. The overall uncertainties for each method vary due to differences in the uncertainties of factors used in each method. The smallest uncertainties apply when the CT dose index for the scanner has been measured using a calibrated pencil ionization chamber.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Clinical characterization of a proton beam continuous uniform scanning system with dose layer stacking

A proton beam delivery system on a gantry with continuous uniform scanning and dose layer stacking at the Midwest Proton Radiotherapy Institute has been commissioned and accepted for clinical use. This paper was motivated by a lack of guidance on the testing and characterization for clinical uniform scanning systems. As such, it describes how these tasks were performed with a uniform scanning beam delivery system. This paper reports the methods used and important dosimetric characteristics of radiation fields produced by the system. The commissioning data include the transverse and longitudinal dose distributions, penumbra, and absolute dose values. Using a 208 MeV cyclotron's proton beam, the system provides field sizes up to 20 and 30 cm in diameter for proton ranges in water up to 27 and 20 cm, respectively. The dose layer stacking method allows for the flexible construction of spread-out Bragg peaks with uniform modulation of up to 15 cm in water, at typical dose rates of 1-3 Gy/min. For measuring relative dose distributions, multielement ion chamber arrays, small-volume ion chambers, and radiographic films were employed. Measurements during the clinical commissioning of the system have shown that the lateral and longitudinal dose uniformity of 2.5% or better can be achieved for all clinically important field sizes and ranges. The measured transverse penumbra widths offer a slight improvement in comparison to those achieved with a double scattering beam spreading technique at the facility. Absolute dose measurements were done using calibrated ion chambers, thermoluminescent and alanine detectors. Dose intercomparisons conducted using various types of detectors traceable to a national standards laboratory indicate that the measured dosimetry data agree with each other within 5%.

43 PARTICLE ACCELERATORS↗

Commissioning of output factors for uniform scanning proton beams

Purpose: Current commercial treatment planning systems are not able to accurately predict output factors and calculate monitor units for proton fields. Patient-specific field output factors are thus determined by either measurements or empirical modeling based on commissioning data. The objective of this study is to commission output factors for uniform scanning beams utilized at the ProCure proton therapy centers. Methods: Using water phantoms and a plane parallel ionization chamber, the authors first measured output factors with a fixed 10 cm diameter aperture as a function of proton range and modulation width for clinically available proton beams with ranges between 4 and 31.5 cm and modulation widths between 2 and 15 cm. The authors then measured the output factor as a function of collimated field size at various calibration depths for proton beams of various ranges and modulation widths. The authors further examined the dependence of the output factor on the scanning area (i.e., uncollimated proton field), snout position, and phantom material. An empirical model was developed to calculate the output factor for patient-specific fields and the model-predicted output factors were compared to measurements. Results: The output factor increased with proton range and field size, and decreased with modulation width. The scanning area and snout position have a small but non-negligible effect on the output factors. The predicted output factors based on the empirical modeling agreed within 2% of measurements for all prostate treatment fields and within 3% for 98.5% of all treatment fields. Conclusions: Comprehensive measurements at a large subset of available beam conditions are needed to commission output factors for proton therapy beams. The empirical modeling agrees well with the measured output factor data. This investigation indicates that it is possible to accurately predict output factors and thus eliminate or reduce time-consuming patient-specific output measurements for proton treatments.

07 ISOTOPE AND RADIATION SOURCES↗

Beam characteristics in two different proton uniform scanning systems: A side-by-side comparison

Purpose: To compare clinically relevant dosimetric characteristics of proton therapy fields produced by two uniform scanning systems that have a number of similar hardware components but employ different techniques of beam spreading. Methods: This work compares two technologically distinct systems implementing a method of uniform scanning and layer stacking that has been developed independently at Indiana University (IU) and by Ion Beam Applications, S. A. (IBA). Clinically relevant dosimetric characteristics of fields produced by these systems are studied, such as beam range control, peak-to-entrance ratio (PER), lateral penumbra, field flatness, effective source position, precision of dose delivery at different gantry angles, etc. Results: Under comparable conditions, both systems controlled beam range with an accuracy of 0.5 mm and a precision of 0.1 mm. Compared to IBA, the IU system produced pristine peaks with a slightly higher PER (3.23 and 3.45, respectively) and smaller, symmetrical, lateral in-air penumbra of 1 mm compared to about 1.9/2.4 mm in the inplane/crossplane (IP/CP) directions for IBA. Large field flatness results in the IP/CP directions were similar: 3.0/2.4% for IU and 2.9/2.4% for IBA. The IU system featured a longer virtual source-to-isocenter position, which was the same for the IP and CP directions (237 cm), as opposed to 212/192 cm (IP/CP) for IBA. Dose delivery precision at different gantry angles was higher in the IBA system (0.5%) than in the IU system (1%). Conclusions: Each of the two uniform scanning systems considered in this work shows some attractive performance characteristics while having other features that can be further improved. Overall, radiation field characteristics of both systems meet their clinical specifications and show comparable results. Most of the differences observed between the two systems are clinically insignificant.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Commissioning dose computation models for spot scanning proton beams in water for a commercially available treatment planning system

Purpose: To present our method and experience in commissioning dose models in water for spot scanning proton therapy in a commercial treatment planning system (TPS). Methods: The input data required by the TPS included in-air transverse profiles and integral depth doses (IDDs). All input data were obtained from Monte Carlo (MC) simulations that had been validated by measurements. MC-generated IDDs were converted to units of Gy mm{sup 2}/MU using the measured IDDs at a depth of 2 cm employing the largest commercially available parallel-plate ionization chamber. The sensitive area of the chamber was insufficient to fully encompass the entire lateral dose deposited at depth by a pencil beam (spot). To correct for the detector size, correction factors as a function of proton energy were defined and determined using MC. The fluence of individual spots was initially modeled as a single Gaussian (SG) function and later as a double Gaussian (DG) function. The DG fluence model was introduced to account for the spot fluence due to contributions of large angle scattering from the devices within the scanning nozzle, especially from the spot profile monitor. To validate the DG fluence model, we compared calculations and measurements, including doses at the center of spread out Bragg peaks (SOBPs) as a function of nominal field size, range, and SOBP width, lateral dose profiles, and depth doses for different widths of SOBP. Dose models were validated extensively with patient treatment field-specific measurements. Results: We demonstrated that the DG fluence model is necessary for predicting the field size dependence of dose distributions. With this model, the calculated doses at the center of SOBPs as a function of nominal field size, range, and SOBP width, lateral dose profiles and depth doses for rectangular target volumes agreed well with respective measured values. With the DG fluence model for our scanning proton beam line, we successfully treated more than 500 patients from March 2010 through June 2012 with acceptable agreement between TPS calculated and measured dose distributions. However, the current dose model still has limitations in predicting field size dependence of doses at some intermediate depths of proton beams with high energies. Conclusions: We have commissioned a DG fluence model for clinical use. It is demonstrated that the DG fluence model is significantly more accurate than the SG fluence model. However, some deficiencies in modeling the low-dose envelope in the current dose algorithm still exist. Further improvements to the current dose algorithm are needed. The method presented here should be useful for commissioning pencil beam dose algorithms in new versions of TPS in the future.

60 APPLIED LIFE SCIENCES↗

Upgrade and benchmarking of a 4D treatment planning system for scanned ion beam therapy

Purpose: Upgrade and benchmarking of a research 4D treatment planning system (4DTPS) suitable for realistic patient treatment planning and treatment simulations taking into account specific requirements for scanned ion beam therapy, i.e., modeling of dose heterogeneities due to interplay effects and range changes caused by patient motion and dynamic beam delivery. Methods: The 4DTPS integrates data interfaces to 4D computed tomography (4DCT), deformable image registration and clinically used motion monitoring devices. The authors implemented a novel data model for 4D image segmentation using Boolean mask volume datasets and developed an algorithm propagating a manually contoured reference contour dataset to all 4DCT phases. They further included detailed treatment simulation and dose reconstruction functionality, based on the irregular patient motion and the temporal structure of the beam delivery. The treatment simulation functionality was validated against experimental data from irradiation of moving radiographic films in air, 3D moving ionization chambers in a water phantom, and moving cells in a biological phantom with a scanned carbon ion beam. The performance of the program was compared to results obtained with predecessor programs. Results: The measured optical density distributions of the radiographic films were reproduced by the simulations to (-2 {+-} 12)%. Compared to earlier versions of the 4DTPS, the mean agreement improved by 2%, standard deviations were reduced by 7%. The simulated dose to the moving ionization chambers in water showed an agreement with the measured dose of (-1 {+-} 4)% for the typical beam configuration. The mean deviation of the simulated from the measured biologically effective dose determined via cell survival was (617 {+-} 538) mGy relative biological effectiveness corresponding to (10 {+-} 9)%. Conclusions: The authors developed a research 4DTPS suitable for realistic treatment planning on patient data and capable of simulating dose delivery to a moving patient geometry for scanned ion beams. The accuracy and reliability of treatment simulations improved considerably with respect to earlier versions of the 4DTPS.

60 APPLIED LIFE SCIENCES↗

SU-E-T-441: Comparison of Dose Distributions for Spot-Scanned Pencil-Beam and Scattered-Beam Proton Treatments of Ocular Tumors

Purpose: To study the cross-field and depth dose profiles of spot-scanned pencil beam configurations for the treatment of ocular tumors and to compare their performance to a simulated scattered beam. Methods: Dose distributions in a cubic water phantom were compared for beams that passed through a final 24mm diameter aperture to deposit maximum dose at 2.4cm depth. The pencil-beam spots formed a hexagonally-packed ring with a center-to-center spacing of 4mm. The protons exited the nozzle with energy 95.5MeV, traversed a 4.5cm water-equivalent range shifter, and travelled either 42.5cm or 100cm to the phantom surface. The aperture-to-phantom distance (APD) was 5.7cm to allow room for eye-tracking hardware. A configuration with APD=0 was also tested. The scattered beam was generated with energy 159MeV, passed through 127mm of Lexan, exited the final aperture, and travelled 5.7cm to the phantom surface. This latter configuration is comparable to the MGH single scattered beamline. All beams were modelled with TOPAS1.0-beta6 compiled with GEANT4.9.6p2. Results: The modeled scattered beam produced a distal fall-off along the central axis of zd90%-zd10%=3.6mm. For the pencil beam, the zd90%-zd10% was 1.6mm in all configurations. The scattered beam's cross-field penumbra at depth of maximum dose was r90%- r10%=1.9mm. For the spot-scanned configuration with the range-shifter-tophantom distance (RsPD) of 100cm, similar cross-field profiles were achieved with r90%-r10%=2.0mm. At shorter RsPD of 42.5cm, the crossfield penumbras were 5.6mm and 7.7mm for APD=0cm and APD=5.7cm, respectively. Conclusion: For proton treatments employing a range shifter, the cross-field and central axis dose profiles depend on the quality of the original beam, the size of the range shifter, the distance from the range shifter exit to the patient, and the distance from the final aperture to the patient. A spot-scanned pencil beam configuration can achieve cross-field penumbras equal to a scattered beam and superior distal gradients.

60 APPLIED LIFE SCIENCES↗