Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SAMPLING DEVICE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

Defect-induced ferromagnetism in undoped In{sub 2}O{sub 3} nanowires

Highlights: • Undoped In{sub 2}O{sub 3} nanowires were synthesized by a thermal evaporation method. • In{sub 2}O{sub 3} nanowires show d{sup 0} ferromagnetism at room temperature. • Large amount of defects were confirmed by PL, UV/vis, and XPS. • Oxygen deficient surfaces and size effect mediating ferromagnetic ordering. - Abstract: We report the observation of intrinsic room-temperature ferromagnetism in undoped In{sub 2}O{sub 3} nanowires synthesized by a thermal evaporation method. The as-grown sample was characterized by X-ray diffraction (XRD), field emission scanning electron microscopy (FE-SEM), transmission electron microscopy (TEM), temperature-dependent photoluminescence (PL), Ultraviolet–visible spectroscopy (UV/vis), X-ray photoelectron spectroscopy (XPS), and superconducting quantum interference device (SQUID). Structural characterizations show that the as-grown sample is single crystal cubic bixbyite structure with 80–100 nm in diameter and 2–4 μm long. Both PL and UV/vis results reveal that the sample exhibits large amount of oxygen vacancies and indium vacancies (V{sub O} and V{sub In}). XPS results indicate that the In{sub 2}O{sub 3} nanowires are significantly oxygen deficient and non-stoichiometric at surface. Experimentally measured magnetic hysteresis curves for undoped In{sub 2}O{sub 3} nanowires clearly display ferromagnetic behavior at room temperature. We believe the ferromagnetism of undoped In{sub 2}O{sub 3} nanowires is ascribed to the large surface area and intrinsic defects mediating the ferromagnetic ordering.

36 MATERIALS SCIENCE↗

Quartz microbalance device for transfer into ultrahigh vacuum systems

An uncomplicated quartz microbalance device has been developed which is transferable into ultrahigh vacuum (UHV) systems. The device is extremely useful for flux calibration of different kinds of material evaporators. Mounted on a commercial specimen holder, the device allows fast quartz microbalance transfer into the UHV and subsequent positioning exactly to the sample location where subsequent thin film deposition experiments shall be carried out. After backtransfer into an UHV sample stage, the manipulator may be loaded in situ with the specimen suited for the experiment. The microbalance device capability is demonstrated for monolayer and submonolayer vanadium depositions with an achieved calibration sensitivity of less the 0.001 ML coverage.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Polystyrene latex separations by continuous flow electrophoresis on the Space Shuttle

The seventh mission of the Space Shuttle carried two NASA experiments in the McDonnell Douglas Astronautics Corporation continuous flow electrophoresis system. The objectives were to test the operation of continuous flow electrophoresis in a reduced gravity environment using stable particles with established electrokinetic properties and specifically to evaluate the influence of the electrical properties of the sample constituents on the resolution of the continuous flow electrophoretic device. Polystrene latex microspheres dispersed in a solution with three times the electrical conductivity of the curtain buffer separated with a significantly larger band spread compared to the second experiment under matched conductivity conditions. It is proposed that the sample of higher electrical conductivity distorted the electric field near the sample stream so that the polystyrene latex particles migrated toward the chamber walls where electroosmosis retarded and spread the sample.

Snyder, R. S.↗

Interface modulated currents in periodically proton exchanged Mg doped lithium niobate

Conductivity in Mg doped lithium niobate (Mg:LN) plays a key role in the reduction of photorefraction and is therefore widely exploited in optical devices. However, charge transport through Mg:LN and across interfaces such as electrodes also yields potential electronic applications in devices with switchable conductivity states. Furthermore, the introduction of proton exchanged (PE) phases in Mg:LN enhances ionic conductivity, thus providing tailorability of conduction mechanisms and functionality dependent on sample composition. To facilitate the construction and design of such multifunctional electronic devices based on periodically PE Mg:LN or similar ferroelectric semiconductors, fundamental understanding of charge transport in these materials, as well as the impact of internal and external interfaces, is essential. In order to gain insight into polarization and interface dependent conductivity due to band bending, UV illumination, and chemical reactivity, wedge shaped samples consisting of polar oriented Mg:LN and PE phases were investigated using conductive atomic force microscopy. In Mg:LN, three conductivity states (on/off/transient) were observed under UV illumination, controllable by the polarity of the sample and the externally applied electric field. Measurements of currents originating from electrochemical reactions at the metal electrode–PE phase interfaces demonstrate a memresistive and rectifying capability of the PE phase. Furthermore, internal interfaces such as domain walls and Mg:LN–PE phase boundaries were found to play a major role in the accumulation of charge carriers due to polarization gradients, which can lead to increased currents. The insight gained from these findings yield the potential for multifunctional applications such as switchable UV sensitive micro- and nanoelectronic devices and bistable memristors.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Analysis of eye-tracking experiments performed on a Tobii T60

Commercial eye-gaze trackers have the potential to be an important tool for quantifying the benefits of new visualization techniques. The expense of such trackers has made their use relatively infrequent in visualization studies. As such, it is difficult for researchers to compare multiple devices obtaining several demonstration models is impractical in cost and time, and quantitative measures from real-world use are not readily available. In this paper, we present a sample protocol to determine the accuracy of a gaze-tacking device.

47 OTHER INSTRUMENTATION↗

Summary of activities

Four space projects' activities are summarized. Design work on the Mars Penetrator Project, in cooperation with the NASA Ames Research Center, is being continued. Efforts are focused on the drilling mechanism which must penetrate the martian subsurface soil to collect and retrieve an uncontaminated sample. The new design consists of a rotary-percussive drill mechanism. This mechanism is optimum for dry drilling, necessary to avoid contamination of the soil sample, in many different soil types. The need for a small, relatively inexpensive device to study the chemical structure of this martian soil was also established. The egg design was chosen for its low cost compared to other systems and potential for a large number of eggs to be deployed on the martian surface. The design process included analysis of the dynamics of reentry, dissipation of heat during reentry, impact with the surface, access to undisturbed soil samples, and ability to gather samples from the soil at three depths. The egg consists of the reentry systems, soil probe lifting system, soil probe package, gas chromatograph, transmitter, and battery power supply. The egg must function only once, but is designed to withstand one martian year. The Mars Mole is designed as a rover-based device which penetrates the martian soil to a depth of up to 10 m, obtains a sample of soil, and returns it to the surface for analysis. The mole was designed to meet the following specifications: (1) weight less than 10 kg; (2) size less than 20 x 20 x 30 cm; (3) power less than 100 W; (4) ability to obtain a sample of at least 5 cc; (5) ability to penetrate fine, loose sand; and (6) need to obtain at least one sample. The space station umbilical connector project is a device which provides the translational motion of the connectors on the Space Station Freedom to allow engagement for power and data transfer. The design is capable of delivering a 20 lb force within the necessary tolerances and will operate reliably in the space environment.

Source record↗

Assessing a Spectroelectrochemical Sensor's Performance for Detecting [Ru(bpy)3]2+ in Natural and Treated Water

A spectroelectrochemical sensor that combines three modes of selectivity in a single device was evaluated in natural and treated water samples using tris-(2,2’-bipyridyl) ruthenium(II) dichloride hexahydrate, [Ru(bpy)3]2+, as a model analyte. The sensor was an optically transparent indium tin oxide (ITO) electrode coated with a thin film of partially sulfonated polystyrene-block-poly(ethylene-ran-butylene)-block-polystyrene (SSEBS). As the potential of the ITO electrode was cycled from +0.7 to +1.3 V, the analyte changed from the colored [Ru(bpy)3]2+ complex to colorless [Ru(bpy)3]3+ complex and the change in absorbance at 450 nm was used as the optical signal for quantification. Calibration curves were obtained for [Ru(bpy)3]2+ in natural well water, river water and treated tap water with detection limits of 108, 139 and 264 nM, respectively. A standard addition method was developed to determine an *unknown* spike addition concentration of [Ru(bpy)3]2+ in well water. The spectroelectrochemical sensor determined the concentration of [Ru(bpy)3]2+ spiked into a sample of Hanford well water to be 0.39*0.03 mM versus the actual concentration of 0.40 mM.

ITO electrode↗

Measurements of thorium and uranium daughters in radioenvironmental samples using γ γ -coincidence spectrometry

We present the performance of a γ γ -coincidence spectrometer for measuring the activities of thorium and uranium daughters in environmental samples. The spectrometer consists of two NaI(Tl) detectors facing each other inside a low-background passive shield. We present coincidence gating schemes for achieving the best signal-to-noise ratios, coincidence detection efficiencies, background levels, and minimum detectable activities. The spectrometer is simulated using Geant4 to correct sample efficiencies for self-absorption effects. The device is used to measure thorium and uranium daughter activities in Brazil nuts, potting mix, and magazine paper. Our results for Brazil nuts agree with some, but not all, previous measurements. Thorium or uranium daughter activities have previously not been reported for commercial potting mix. For magazine paper, our measured activities are lower than most previously determined values.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Geometric control of magnetic domain morphology in electrodeposited Ni rich NiPt mesoscopic wires

In this paper, we study the electrodeposited Ni—Pt magnetic wires, exploring the mechanisms by which changes in geometry and composition influence the local magnetic structure. The samples were prepared by electrodeposition, their elemental composition was analyzed by energy dispersive X-ray spectroscopy, and phase analysis was carried out by an X-ray diffraction measurement. Magnetic force microscopy measurements, and magnetic force microscopy measurements in magnetic field were carried out to study the domain morphology of the prepared samples. Magnetization characteristics were measured via vibrating sample magnetometry mode of a superconducting quantum interference device. Here, the results were analyzed and compared with micromagnetic simulations. It is shown that a strong perpendicular magnetic anisotropy is responsible for the characteristic checkerboard-like surface magnetization patterns, which can be tuned by geometrical constriction and Ni content. Understanding these relationships provides insights into the design of magnetic materials with tailored properties for advanced applications, like magnetic sensors.

Binary alloy↗

New frontiers in atom probe tomography: a review of research enabled by cryo and/or vacuum transfer systems

There has been a recent surge in the use of cryo and/or vacuum specimen preparation and transfer systems that are broadening the scope of research enabled by the microscopy technique of atom probe tomography. This is driven by the fact that, like for many microscopes, the application of atom probe to air and temperature sensitive materials or wet biological specimens has previously been limited by through-air-transfer and through-vacuum-transfer at room temperature. Here we provide an overview of the critical areas of research that require these new transfer and analysis protocols, as well as a review of current advances in transfer devices, environmental cells and glove boxes for controlled sample manipulation. This includes the study of catalysis and corrosion, the application of atom probe to biological samples, the study of liquid-solid interfaces, natural ageing investigations and the analysis of hydrogen in metals.

36 MATERIALS SCIENCE↗

Differential electron yield imaging with STXM

In this report total electron yield (TEY) imaging is an established scanning transmission X-ray microscopy (STXM) technique that gives varying contrast based on a sample's geometry, elemental composition, and electrical conductivity. However, the TEY-STXM signal is determined solely by the electrons that the beam ejects from the sample. A related technique, X-ray beam-induced current (XBIC) imaging, is sensitive to electrons and holes independently, but requires electric fields in the sample. Here we report that multi-electrode devices can be wired to produce differential electron yield (DEY) contrast, which is also independently sensitive to electrons and holes, but does not require an electric field. Depending on whether the region illuminated by the focused STXM beam is better connected to one electrode or another, the DEY-TXM contrast changes sign. DEY-STXM images thus provide a vivid map of a device's connectivity landscape, which can be key to understanding device function and failure. To demonstrate an application in the area of failure analysis, we image a 100 nm, lithographically-defined aluminum nanowire that has failed after being stressed with a large current density.

47 OTHER INSTRUMENTATION↗

Monitoring of WEEE plastics in regards to brominated flame retardants using handheld XRF

Highlights: • Specification of an empirical factor for conversion from bromine to PBB and PBDE. • The handheld XRF device was validated for this particular application. • A very large number of over 4600 pieces of monitor housings was analysed. • The recyclable fraction mounts up to 85% for TV but only 53% of PC waste plastics. • A high percentage of pieces with bromine contents of over 50,000 ppm was obtained. - Abstract: This contribution is focused on the on-site determination of the bromine content in waste electrical and electronic equipment (WEEE), in particular waste plastics from television sets (TV) and personal computer monitors (PC) using a handheld X-ray fluorescence (XRF) device. The described approach allows the examination of samples in regards to the compliance with legal specifications for polybrominated biphenyls (PBBs) and polybrominated diphenyl ethers (PBDEs) directly after disassembling and facilitates the sorting out of plastics with high contents of brominated flame retardants (BFRs). In all, over 3000 pieces of black (TV) and 1600 pieces of grey (PC) plastic waste were analysed with handheld XRF technique for this study. Especially noticeable was the high percentage of pieces with a bromine content of over 50,000 ppm for TV (7%) and PC (39%) waste plastics. The applied method was validated by comparing the data of handheld XRF with results obtained by GC–MS. The results showed the expected and sufficiently accurate correlation between these two methods. It is shown that handheld XRF technique is an effective tool for fast monitoring of large volumes of WEEE plastics in regards to BFRs for on-site measurements.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Portable x-ray fluorescence spectrometer for coating thickness measurement

A handheld x-ray spectrometer has been realized and tested. The purpose of the device is to measure the thickness of coated samples in the range of 1-1500 nm in an industrial environment. Accuracy of {approx}3% has been achieved in this range with a measurement time of 1 min. Automated software has been implemented to allow utilization by a nonspecialist operator. An automated calibration procedure, based on measurements of reference samples, is used.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fluctuations in induced charge introduced by Te inclusions within CdZnTe radiation detectors

Recently, homogenization theory based on a multiple-scale perturbation of the electron transport equation has been used to derive a mathematical framework for modeling the excess charge lost to Te inclusions within radiation detectors based on semi-insulating cadmium zinc telluride (CdZnTe). In that theory, the heterogeneous material is mathematically replaced by a homogenized CdZnTe crystal whose effective electron attenuation length incorporates the additional uniform electron trapping caused by the inclusions. In this paper, the homogenization theory is extended to incorporate fluctuations in the induced charge (i.e., charge collection nonuniformities) introduced by the random position and size distributions of a noncorrelated population of small (i.e, <20 {mu}m) Te inclusions. Analysis of the effective parameters derived within the homogenized framework is used to develop a probability distribution of effective electron attenuation lengths, and therefore effective mobility-lifetime products, as a function of both the position and size distribution of Te inclusions. Example distributions are detailed for the case of an exponential size distribution at various number densities. Further, it is demonstrated that the inclusion-induced material nonuniformities derived in this paper can be numerically sampled efficiently, making them applicable to Monte Carlo device simulation of realistic CdZnTe detectors. Simulated charge induction maps and pulse-height spectra are presented and compared to recently published measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Formation of non-substitutional β-Sn defects in Ge{sub 1−x}Sn{sub x} alloys

Although group IV semiconductor alloys are expected to form substitutionally, in Ge{sub 1−x}Sn{sub x} this is true only for low concentrations (x < 0.13). The use of these alloys as a narrow gap semiconductor depends on the ability to produce samples with the high quality required for optoelectronic device applications. In a previous paper, we proposed the existence of a non-substitutional complex defect (β-Sn), consisting of a single Sn atom in the center of a Ge divacancy, which may account for the segregation of Sn at large x. Afterwards, the existence of this defect was confirmed experimentally. In this paper we study the local environment and the interactions of the substitutional defect (α-Sn), the vacancy in Ge, and the β-Sn defect by performing extensive numerical ab initio calculations. Our results confirm that a β-Sn defect can be formed by natural diffusion of a vacancy around the substitutional α-Sn defect, since the energy barrier for the process is very small.

36 MATERIALS SCIENCE↗

Mechanism of tailored magnetic anisotropy in amorphous Co{sub 68}Fe{sub 24}Zr{sub 8} thin films

The mechanism of tailored magnetic anisotropy in amorphous Co{sub 68}Fe{sub 24}Zr{sub 8} thin films was investigated by ferromagnetic resonance (FMR) on samples deposited without an applied magnetic field, with an out-of-plane field and an in-plane field. Analysis of FMR spectra profiles, high frequency susceptibility calculations, and statistical simulations using a distribution of local uniaxial magnetic anisotropy reveal the presence of atomic configurations with local uniaxial anisotropy, of which the direction can be tailored while the magnitude remains at an intrinsically constant value of 3.0(2) kJ/m{sup 3}. The in-plane growth field remarkably sharpens the anisotropy distribution and increases the sample homogeneity. The results benefit designing multilayer spintronic devices based on highly homogeneous amorphous layers with tailored magnetic anisotropy.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Accuracy of momentum and gyrodensity transport in global gyrokinetic particle-in-cell simulations

Gyrokinetic Particle-In-Cell (PIC) simulations based on conservative Lagrangian formalisms admit transport equations for conserved quantities such as gyrodensity and toroidal momentum, and these can be derived for arbitrary wavelength, even though previous applications have used the long-wavelength approximation. In control-variate PIC simulations, a consequence of the different treatment of the background (f{sub 0}) and perturbed parts (δf), when a splitting f = f{sub 0} + δf is performed, is that analytical transport relations for the relevant fluxes and moments are only reproduced in the large marker number limit. The transport equations for f can be used to write the inconsistency in the perturbed quantities explicitly in terms of the sampling of the background distribution f{sub 0}. This immediately allows estimates of the error in consistency of momentum transport in control-variate PIC simulations. This inconsistency tends to accumulate secularly and is not directly affected by the sources and noise control in the system. Although physical tokamaks often rotate quite strongly, the standard gyrokinetic formalism assumes weak perpendicular flows, comparable to the drift speed. For systems with such weak flows, maintaining acceptably small relative errors requires that a number of markers scale with the fourth power of the linear system size to consistently resolve long-wavelength evolution. To avoid this unfavourable scaling, an algorithm for exact gyrodensity transport has been developed, and this is shown to allow accurate simulations with an order of magnitude fewer markers.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗