Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Radiation effects on electronics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

Precise Q value determinations for forbidden and low energy $\beta $-decays using Penning trap mass spectrometry

Nuclear β-decay provides a laboratory for investigating weak decays occurring inside the nuclear medium. This provides information on the resulting subtle nuclear and atomic effects, and on the underlying interaction and the properties of the particles that are involved, particularly of the neutrino. The Q value of the decay corresponds to the energy equivalent of the mass difference between parent and daughter atoms, and can be precisely and accurately measured using Penning trap mass spectrometry. In this paper we discuss Penning trap Q value measurements for forbidden β-decays of long-lived primordial nuclides, and for a subset of β-unstable nuclides that could potentially undergo a very low energy decay to an excited state in the daughter nucleus. Here we discuss applications of these measurements to tests of systematics in detectors that perform precise β-spectrum measurements, as inputs for theoretical shape factor, electron branching ratio and half-life calculations, and to identify nuclides that could serve as new candidates in direct neutrino mass determination experiments.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Cooling Design and Thermal Analysis for Thermal Shields of a Cryocooler-Cooled Superconducting ECR Ion Source MARS-D Magnet

Here, a demonstrative NbTi based Mixed Axial and Radial field System (MARS-D) is being developed for a next-Generation Electron Cyclotron Resonance Ion Source (ECRIS) at Lawrence Berkeley National Laboratory (LBL), which employs a novel closed-loop coil design scheme that more efficiently utilizes conductor fields and extend the application of NbTi for high frequency (up to 45 GHz) ECR operation. The NbTi MARS-D magnet consists of a single hexagonally shaped closed-loop coil and a set of auxiliary solenoids. A cryostat for cooling the MARS-D magnet is under design at LBL. The MARS-D magnet working around 4.2 K will be bath-cooled in liquid helium using multiple two-stage cryocoolers. An intermediate temperature thermal radiation shield is adopted to reduce the heat leakage imposed on 4.2 K coil cold mass from room temperature. The thermal shield is conduction-cooled by the first-stage cold heads of four two-stage cryocoolers and the cold head of a single-stage cryocooler shared with nine binary leads. The temperature in the area of the shield that warm ends of HTS leads are mounted on is expected no higher than 60 K, which is limited by maximum allowable working temperature of HTS leads. The paper presents thermal analysis on the thermal radiation shield including heat loads and effects of eddy current induced during quench on its material selection.

ECRIS↗

Inner Belt Electron Decay Timescales: A Comparison of Van Allen Probes and DREAM3D Losses Following the June 2015 Storm

Abstract NASA's Van Allen Probes observed significant, long‐lived fluxes of inner belt electrons up to ∼1 MeV after geomagnetic storms in March and June 2015. Reanalysis of Magnetic Electron Ion Spectrometer (MagEIS) data with improved background correction showed a clearer picture of the relativistic electron population that persisted through 2016 and into 2017 above the Fennell et al. (2015, https://doi.org/10.1002/2014gl062874 ) limit. The intensity and duration of these enhancements allow estimation of decay timescales for comparison with simulated decay rates and theoretical lifetimes. We compare decay timescales from these data and DREAM3D simulations based on them using geomagnetic activity‐dependent pitch angle diffusion coefficients derived from plasmapause‐indexed wave data (Malaspina et al., 2016, https://doi.org/10.1002/2016gl069982 , 2018, https://doi.org/10.1029/2018gl078564 ) and phase space densities derived from MagEIS observations. Simulated decay rates match observed decay rates more closely than the theoretical lifetime due to significantly nonequilibrium pitch angle distributions in simulation and data. We conclude that nonequilibrium effects, rather than a missing diffusion or loss process, account for observed short decay rates.

79 ASTRONOMY AND ASTROPHYSICS↗

Hybrid height and slope figuring method for grazing-incidence reflective optics

Grazing-incidence reflective optics are commonly used in synchrotron radiation and free-electron laser facilities to transport and focus the emitted X-ray beams. To preserve the imaging capability at the diffraction limit, the fabrication of these optics requires precise control of both the residual height and slope errors. However, all the surface figuring methods are height based, lacking the explicit control of surface slopes. Although our preliminary work demonstrated a one-dimensional (1D) slope-based figuring model, its 2D extension is not straightforward. In this study, a novel 2D slope-based figuring method is proposed, which employs an alternating objective optimization on the slopes in the x - and y -directions directly. An analytical simulation revealed that the slope-based method achieved smaller residual slope errors than the height-based method, while the height-based method achieved smaller residual height errors than the slope-based method. Therefore, a hybrid height and slope figuring method was proposed to further enable explicit control of both the height and slopes according to the final mirror specifications. An experiment to finish an elliptical-cylindrical mirror using the hybrid method with ion beam figuring was then performed. Both the residual height and slope errors converged below the specified threshold values, which verified the feasibility and effectiveness of the proposed ideas.

36 MATERIALS SCIENCE↗

Controlling Ion Uptake in Carboxylated Mixed Conductors

Organic mixed ionic‐electronic conductors (OMIECs) have garnered significant attention due to their capacity to transport both ions and electrons, making them ideal for applications in energy storage, neuromorphics, and bioelectronics. However, charge compensation mechanisms during the polymer redox process remain poorly understood, and are often oversimplified as single‐ion injection with little attention to counterion effects. To advance understanding and design strategies toward next‐generation OMIEC systems, a series of p‐channel carboxylated mixed conductors is investigated. Varying side‐chain functionality, distinctive swelling character is uncovered during electrochemical doping/dedoping with model chao‐/kosmotropic electrolytes. Carboxylic acid functionalized polymers demonstrate strong deswelling and mass reduction during doping, indicating cation expulsion, while ethoxycarbonyl counterparts exhibit prominent mass increase, pointing to an anion‐driven doping mechanism. By employing operando grazing incidence X‐ray fluorescence (GIXRF), it is revealed that the carboxyl functionalized polymer engages in robust cation interaction, whereas ester functionalization shifts the mechanism towards no cation involvement. It is demonstrated that cations are pivotal in mitigating swelling by counterbalancing anions, enabling efficient anion uptake without compromising performance. These findings underscore the transformative influence of functionality‐driven factors and side‐chain chemistry in governing ion dynamics and conduction, providing new frameworks for designing OMIECs with enhanced performance and reduced swelling.

carboxylated polythiophenes↗

Application of deep learning methods for beam size control during user operation at the Advanced Light Source

Past research at the Advanced Light Source (ALS) provided a proof-of-principle demonstration that deep learning methods could be effectively employed to compensate for the significant perturbations to the transverse electron beam size induced by user-controlled adjustments of the insertion devices. However, incorporating these methods into the ALS’ daily operations has faced notable challenges. The complexity of the system’s operational requirements and the significant upkeep demands has restricted their sustained application during user operation. Here, we introduce the development of a more robust neural network (NN)-based algorithm that utilizes a novel online fine-tuning approach and its systematic integration into the day-to-day machine operations. Our analysis emphasizes the process of NN model selection, demonstrates the superior performance of the NN-based method over traditional feedback methods, and examines the effectiveness and resilience of the new algorithm during user-operation scenarios. Published by the American Physical Society 2024

43 PARTICLE ACCELERATORS↗

Impact of the Electronic Properties of Chalcogenide Ligands in their Complexation with Uranyl Nitrate Complexes

The idea of covalency being directly correlated with selectivity in f-element separations has gained attention over the years. However, “covalency” as a concept is still under debate as it is not an experimental nor quantum mechanical observable. Regardless, covalency along with ionicity are still the main concepts used to explain the nature of the chemical bond of coordination complexes. Another concept that has gained the attention in the separations community is the hard-soft acid-base (HSAB) theory, which favors soft-donor ligands having the potential to increase selectivity for actinides (An) over the lanthanides (Ln) due to their ability to engage more effectively f-electrons in covalent interactions. However, it has been shown that while using softer donor ligands in fact increased orbital mixing and covalency with the actinides, it compromises the strength of the interaction owing to a decrease in the metal-ligand electrostatic interactions.1 Herein, we study the electronic structure of different types of chalcogenide ligands (LE, E = O, S, Se), their interaction with the uranyl ion, and their complexation free energies. Surprisingly, contrary to the expected order of covalency, i.e. An–LSe > An–LS > An–LO, our results suggest that the degree of covalency and associated complexation free energies depend on the nature of the coordinating moiety rather than solely on the directly coordinated atom. 1) Sadhu, Biswajit, and Michael Dolg. Enhancing actinide (III) over lanthanide (III) selectivity through hard-by-soft donor substitution: exploitation and implication of near-degeneracy-driven covalency. Inorganic Chemistry, 2019, 58, 9738 – 9748.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

α Irradiation Response on the Electronic Transport Properties of p -B 12 P 2

B 12 P 2 , a wide bandgap semiconductor, has been previously reported to self-heal from high-energy electron bombardment as determined from transmission electron microscopy. However, the effect of irradiation on the electronic transport properties of B 12 P 2 has not been studied. We report electrical transport measurements on B 12 P 2 after α irradiation. The temperature-dependent Hall effect was measured on p-type B 12 P 2 after successive α irradiation from 210 Po over a fluence range of 1 × 10 11 –1 × 10 13 α/cm 2 to test for self-healing of B 12 P 2 to α bombardment. Prior to irradiation, B 12 P 2 displayed electrical transport characteristics of both hopping and impurity/defect band conduction due to background impurities and growth-induced defects. Fluences of 5 × 10 12 α/cm 2 or greater caused a decrease in the hole mobility and an increase in defect band conduction, suggesting defect accumulation in B 12 P 2 .

36 MATERIALS SCIENCE↗

Simulation of the spatial shift in detector response for polarized protons within a calorimeter

Measurement of the helicity dependent elastic electron-proton scattering cross section provides a key means of investigating parity violation within the proton. However, such measurements exhibit potential instrumental effects associated with the detection of polarized recoiled protons. In particular, spin-orbit interactions within a massive detector induce a systematic spatial shift in the detector signal. In this study, we determine the size of this shift using the Geant4 simulation toolkit. For a typical hadron calorimeter, we found a polarization dependent shift on the order of 0.01-0.1 mm, multiple orders of magnitude smaller than the typical spatial resolution seen in hadronic calorimeters. Additionally, we provide the custom modifications required of the Geant4 source code to implement the quasi-elastic scattering of polarized protons incident on nuclei in the detector. The modifications are readily extendable to generic matter sources, and can be used for the study of additional spin dependent observables in Geant4.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

New Perspectives on Spectroscopic Factor Quenching from Reactions

The evolution of single-particle strengths as the neutron-to-proton asymmetry changes informs us of the importance of short- and long-range correlations in nuclei and has therefore been extensively studied for the last two decades. Surprisingly, the strong asymmetry dependence of these strengths and their extreme values for highly asymmetric nuclei inferred from knockout reaction measurements on a target nucleus are not consistent with what is extracted from electron-induced, transfer, and quasi-free reaction data, constituting a two-decade old puzzle. This work presents the first consistent analysis of one-nucleon transfer and one-nucleon knockout data, in which theoretical uncertainties associated with the nucleon-nucleus effective interactions considered in the reaction models are quantified using a Bayesian analysis. Here, our results demonstrate that, taking into account these uncertainties, the spectroscopic strengths of loosely bound nucleons extracted from both probes agree with each other and, although there are still discrepancies for deeply bound nucleons, the slope of the asymmetry dependence of the single-particle strengths inferred from transfer and knockout reactions are consistent within 1 σ . Both probes are consistent with a small asymmetry dependence of these strengths. The uncertainties obtained in this work represent a lower bound and are already significantly larger than the original estimates.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Improvements to In-Canal Assay of High Specific Activity 60Co at the ATR

Improvements to the quality of measurements in the assaying of High Specific Activity (HSA) cobalt 60 produced at the Advanced Test Reactor at the Idaho National Laboratory are presented. Such assays are conducted regularly between cycles at the ATR, and due to the radiological safety concerns, they are performed within the ATR canal. A standard ion chamber detector was placed in a collimated assay tube within the canal. Another tube, parallel to the detector, was used to position various cobalt 60 standards and targets. The collimated port between these tubes allows for the targets to be pulled across via a winch system. Previous measurements were performed at discrete 1.5-inch steps using a hand-cranked winch system. Charge was collected and integrated for 10 seconds at each discrete step during a scan. Two substantial improvements to the assay include an electronically controlled, motor-driven winch system and a software controlled continuous charge collection. Combined, these changes improved the quality of measurements as well as streamline the assay process. Further examination of these charge profiles indicated a reasonable amount of photon scattering, or shine, before a line-of-sight is established. This created inaccuracies in the reported activity of the cobalt targets. A series of MCNP-6.3 calculations were performed in an effort to quantify and correct for this shine effect. The results of the calculations and how they were employed to a create shine correction factor for the in-canal cobalt assay at the ATR are presented. The overall bias showed an overestimation of the HSA cobalt 60 activity by around 7-8%.

07 - ISOTOPES AND RADIATION SOURCES↗

Effect of growth dynamics on the structural, photophysical and pseudocapacitance properties of famatinite copper antimony sulphide colloidal nanostructures (including nanosheets)

Facile phase selective synthesis of copper antimony sulphide (CAS) nanostructures is important because of their tunable photoconductive and electrochemical properties. In this study, off-stoichiometric famatinite phase CAS (fCAS) quasi-spherical and quasi-hexagonal colloidal nanostructures (including nanosheets) of sizes, 2.4–18.0 nm were grown under variable conditions of temperature (60–200 °C), time and oleylamine capping ligand concentration using copper(II) acetylacetonate and antimony(III) diethyldithiocarbamate precursors. Data from powder X-ray diffraction, Raman spectroscopy and high-resolution scanning/transmission electron microscopy confirm the tetragonal structure of the famatinite phase. X-ray photoelectron spectroscopy, transmission electron microscopy and scanning electron microscopy-energy dispersive X-ray spectroscopy data suggest a correlation of particle size, morphology and composition of the off-stoichiometric fCAS nanostructures with growth temperature and time, and oleylamine concentration. The off-stoichiometric Cu 3-a Sb 1+b S 4±c (a, b, c – mole fractions) nanostructures being severely copper-deficient and antimony-rich, exhibit shallow-lying acceptor copper vacancy states, deep-lying donor states of antimony interstitials, sulphur vacancies and antimony-copper antisites and shallow-lying acceptor surface trapping states. Further, these electronic states are likely implicated in tunable UV-visible absorption and bandgaps between 2.3 and 2.8 eV, and broad visible-NIR photoluminescence with fast recombination of radiative lifetimes between 0.2 and 6.2 ns, confirmed from absorption, steady-state and time-resolved photoluminescence spectroscopies. Additionally, cyclic voltammetry and electrochemical impedance spectroscopy confirm that electrodes of the fCAS nanostructures display slightly variable pseudocapacitance of charge-storage primarily via possible sodium ion intercalation with a high specific capacitance of ~84 F g -1 obtained at a scan rate of 5 mV s -1 . Overall, these results show the influence of composition, in particular point defects, phase quality and morphology on the optical and pseudocapacitance properties of fCAS nanostructures, suitable as solar absorbers or electrodes for energy storage devices.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Methane Catalytic Pyrolysis by Microwave and Thermal Heating over Carbon Nanotube-Supported Catalysts: Productivity, Kinetics, and Energy Efficiency

Methane catalytic pyrolysis, which is the reaction to produce hydrogen and carbon without emitting CO 2 , represents an approach for decarbonization using natural gas as an energy resource. In this work, the endothermic pyrolysis reaction was carried out under two heating scenarios: convective thermal heating and microwave-driven irradiative heating. The pyrolysis reaction was conducted at 550-600 °C over carbon nanotube-supported Ni-Pd and Ni-Cu catalysts. On both catalysts, an enhanced methane conversion rate was observed under microwave irradiation. The enhanced catalytic activity was hypothetically caused by the presence of free electrons in the carbon atoms within CNT that enabled the CNT support to absorb microwave energy effectively and to be heated efficiently by microwave. The microwave catalytic pyrolysis has shown improvement in kinetics, where the apparent activation energy dropped from 45.5 kJ/mol under conventional convective heating to 24.8 kJ/mol under microwave irradiation. When the methane conversion rate is increased by 37 %, the microwave power consumption only changed by 10.8 %. The research demonstrated the potential of transforming natural gas to clean hydrogen and value-added carbon in a more energy-efficient way. Process simulation and techno-economic analysis showed that potentially hydrogen minimum selling price of about $1 /kg H 2 could be achieved.

03 NATURAL GAS↗

Jet angularities in photoproduction at the Electron-Ion Collider

We consider the one-parameter family of jet substructure observables known as angularities using the specific case of inclusive jets arising from photoproduction events at an Electron-Ion Collider (EIC). We perform numerical calculations at next-to-leading logarithmic accuracy within perturbative QCD and compare our results to PYTHIA 6 predictions. Overall, we find good agreement and conclude that jet substructure observables are feasible at the EIC despite the relatively low jet transverse momentum and particle multiplicities. We investigate the size of subleading power corrections relevant at low energies within the Monte Carlo setup. In order to establish the validity of the Monte Carlo tune, we also perform comparisons to jet shape data at HERA. We further discuss detector requirements necessary for angularity measurements at an EIC, focusing on hadron calorimeter energy and spatial resolutions. Possible applications of precision jet substructure measurements at the EIC include the tuning of Monte Carlo event generators, the extraction of nonperturbative parameters and studies of cold nuclear matter effects.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Transient Photocurrent From High-Voltage Vertical GaN Diodes Irradiated With Electrons: Experiments and Simulations

Radiation-hard high-voltage vertical GaN p-n diodes are being developed for use in power electronics subjected to ionizing radiation. Here, we present a comparison of the measured and simulated photocurrent response of diodes exposed to ionizing irradiation with 70 keV and 20 MeV electrons at dose rates in the range of 1.4x10 7 - 5.0x10 8 rad(GaN)/s. The simulations correctly predict the trend in measured steady-state photocurrent and agree with experimental results within a factor of 2. Furthermore, simulations of the transient photocurrent response to dose rates with uniform and non-uniform ionization depth profiles uncover the physical processes involved that cannot be otherwise experimentally observed due to orders of magnitude larger RC time constant of the test circuit. The simulations were performed using an Exploratory Physics Development code developed at Sandia National Laboratories. The code offers the capability to include defect physics under more general conditions, not included in commercially available software packages, extending the applicability of the simulations to different types of radiation environments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A combined theoretical-experimental investigation of thermal transport in low-dose irradiated thorium dioxide

During reactor operation, nuclear fuels are subject to extreme temperature and irradiation conditions which can significantly degrade the fuel's thermal transport properties. The reduction in thermal conductivity of the fuel as a result of irradiation-induced lattice defects is arguably the most important fuel performance metric in regard to reactor efficiency and safety. Because thorium dioxide (ThO2) is suitable as a model system for more complex materials such as UO2 and its mixed oxides, we present a theoretical investigation of thermal conductivity reduction seen in defect-bearing thorium dioxide and compare directly to experimental measurements. Phonon-mediated thermal transport of the fuel is modeled by a solution to the Boltzmann transport equation (BTE) for phonons. A cluster dynamics (CD) model for lattice defect evolution during irradiation predicts defect densities which are used as input to the BTE for modeling phonon-defect scatterings. Phonon scatterings by lattice defects include those from point defects and vacancy clusters and interstitial clusters of various sizes. The CD model is benchmarked against structural defect characterization of irradiated thorium dioxide using electron microscopy. Thermal conductivity predicted by the BTE model is compared to measured values for irradiated thorium dioxide specimens below room temperature to isolate effects of phonon-defect scattering from intrinsic 3-phonon processes, which dominate at higher temperatures. The computed conductivity values are in partial agreement at temperatures close to room temperature while slight deviations are observed at the lowest measured temperatures, suggesting that implemented phonon-defect scattering cross-section expressions may not be adequate for low temperatures. The presented work provides a necessary investigation of the influence of irradiation induced defects on fuel performance and represents a first step toward a full characterization of phonon mediated thermal transport in irradiated materials with complex defect microstructure.

36 MATERIALS SCIENCE↗

Archival records housed at USTUR support radium dial worker dosimetry

The American radium dial worker (RDW) cohort of over 3200 persons is being revisited as part of the Million Person Study (MPS) to include a modern approach to RDW dosimetry. An exceptional source of data and contextualization in this project is an extensive collection of electronic records (digitized from existing microfilm and microfiche) housed at the United States Transuranium and Uranium Registries (USTUR). Although the type, extent, and quality (e.g. legibility) of record(s) varies between individuals, the remarkable occupational, medical and demographic data include in vivo radiation measurements (e.g. radon breath, whole body counts), autopsy results, medical records (including copies of radiographs), interviews over the years, and correspondence. Of particular dosimetric interest are the details of radiation measurements. For example, there are some instances where hand-written and transcribed values are both available, along with notes providing context for why a particular measurement in a series of measurements was chosen to assign an intake, or if there were concerns about a particular measurement. Born prior to 1935, RDW have nearly all passed away. Thus, the updated dosimetry, especially for the skeletal tissues, will allow the correlation of lifetime cumulative dose with radiation risk. Here we review typical information available in this collection of historical records and highlight some interesting finds. Additionally, we discuss the relevance to current and ongoing work related to updating the dosimetry of the RDW in the MPS, including providing an example of the usefulness of information contained in these records. The RDW cohort provides a unique historical perspective on occupational exposure to radium, making it a valuable dataset for understanding long-term health effects and improving current radiation protection standards.

Million Person Study↗

Two-photon exchange from intermediate state resonances in elastic electron-proton scattering

In this paper, we use a recently developed dispersive approach to compute the two-photon exchange (TPE) correction to elastic electron-proton scattering, including contributions from hadronic $J^P=1/2^\pm$ and $3/2^\pm$ resonant intermediate states below~1.8~GeV. For the transition amplitudes from the proton ground state to the resonant excited states we employ new exclusive meson electroproduction data from CLAS at $Q^2 \lesssim 5$~GeV$^2$, and we explore the effects of both fixed and dynamic widths for the resonances. Among the resonant states, the $N(1520)~\!3/2^-$ becomes dominant for $Q^2 \gtrsim 2$~GeV$^2$, with a sign opposite to the comparably sized $\Delta(1232)~\!3/2^+$ contribution, leading to an overall increase in the size of the TPE correction to the cross section relative to the nucleon only contribution at higher $Q^2$ values. The results are in good overall agreement with recent $e^+ p$ to $e^- p$ cross section ratio and polarization transfer measurements, and provide compelling evidence for a resolution of the electric to magnetic form factor ratio discrepancy.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗