Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Radiation detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

A hierarchical Bayesian model for background variation in radiation source localization

In this paper, we apply a new model to account for varying background radiation in radiological source localization. We present a hierarchical Bayesian model that simultaneously infers background and source location parameters without requiring separate estimation of the background radiation at each detector location. We employ a simplified photon transport model to reduce the computational expense of Bayesian model calibration. Furthermore, we demonstrate the model accuracy by localizing a cesium-137 source in a simulated city block, and we analyze experimental field measurements with varying background. In both cases, the model provides sufficient fidelity that we can locate the source while simultaneously estimating background radiation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Tunable Antireflection Layers for Planar Bolometer Arrays

It remains a challenge to obtain high-efficiency coupling of far-infrared through millimeter radiation to large-format detector arrays. The conventional approach of increasing detector coupling is to use reflective backshorts. However, this approach often results in excessive systematic errors resulting from reflections off the backshort edge. An alternate approach to both increasing quantum efficiency and reducing systematics associated with stray light is to place an antireflective coating near the front surface of the array. When incorporated with a resistive layer and placed behind the detector focal plane, the AR coating can serve to prevent optical ghosting by capturing radiation transmitted through the detector. By etching a hexagonal pattern in silicon, in which the sizes of the hexes are smaller than the wavelength of incident radiation, it is possible to fabricate a material that has a controllable dielectric constant, thereby allowing for simple tunable optical device fabrication. To this end, we have fabricated and tested tunable silicon "honeycomb" AR layers and AR/resistive layer devices. These devices were fabricated entirely out of silicon in order to eliminate problems associated with differential contraction upon detector cooling.

Brown, Ari-David↗

A study of radiation tolerance in optical cements

We study the effect ionizing radiation has on light transmission in the wavelength range 190–1100 nm for a number of optically clear epoxies. We find that the transmittance of traditional, commercially available, optical epoxies show significant degradation for exposures of 1×10 12 MIPs/cm 2 . Degradation of light transmission progresses from the shortest wavelengths at low doses to longer wavelengths as the dose increases. In epoxy joints that are 0.1 mm thick, we observe that more than 5% of the light is lost for wavelengths less than 400 nm for traditional optical epoxies. Our studies have identified an optically clear epoxy that shows little degradation for radiation exposures up to 5.9× 10 14 MIPs/cm 2 (≈ 220 kGy).

Radiation-hard detectors↗

In-flight radiation measurements on STS-60

A joint investigation between the United States and Russia to study the radiation environment inside the Space Shuttle flight STS-60 was carried out as part of the Shuttle-Mir Science Program (Phase 1). This is the first direct comparison of a number of different dosimetric measurement techniques between the two countries. STS-60 was launched on 3 February 1994 in a nearly circular 57 degrees x 353 km orbit with five U.S. astronauts and one Russian cosmonaut for 8.3 days. A variety of instruments provided crew radiation exposure, absorbed doses at fixed locations, neutron fluence and dose equivalent, linear energy transfer (LET) spectra of trapped and galactic cosmic radiation, and energy spectra and angular distribution of trapped protons. In general, there is good agreement between the U.S. and Russian measurements. The AP8 Min trapped proton model predicts an average of 1.8 times the measured absorbed dose. The average quality factor determined from measured lineal energy, y, spectra using a tissue equivalent proportional counter (TEPC), is in good agreement with that derived from the high temperature peak in the 6LiF thermoluminescent detectors (TLDs). The radiation exposure in the mid-deck locker from neutrons below 1 MeV was 2.53 +/- 1.33 microSv/day. The absorbed dose rates measured using a tissue equivalent proportional counter, were 171.1 +/- 0.4 and 127.4 +/- 0.4 microGy/day for trapped particles and galactic cosmic rays, respectively. The combined dose rate of 298.5 +/- 0.82 microGy/day is about a factor of 1.4 higher than that measured using TLDs. The westward longitude drift of the South Atlantic Anomaly (SAA) is estimated to be 0.22 +/- 0.02 degrees/y. We evaluated the effects of spacecraft attitudes on TEPC dose rates due to the highly anisotropic low-earth orbit proton environment. Changes in spacecraft attitude resulted in dose-rate variations by factors of up to 2 at the location of the TEPC.

NASA Discipline Radiation Health↗

Scintillation properties of diamond powders and feasibility of using them in thermal neutron detectors

Diamond offers unique properties for radiation detection, including high radiation hardness, very low gamma sensitivity, and fast response. Conventional diamond detectors rely on charge collection, but this approach requires ultra-pure single crystals and suffers from radiation-induced degradation. Here, in this work, we demonstrate an alternative approach using diamonds as scintillators for detection of charged particles and thermal neutrons. Prototypes were fabricated from commercially available diamond powders bonded to glass substrates and coupled with 6 LiF converters and silicon photomultipliers (SiPMs) and conventional PMTs. We characterized their scintillation properties under alpha particle excitation, x-ray photoluminescence, and thermal neutrons. The tryout detectors exhibit strong scintillation light signals, nanosecond-scale response times, and neutron detection efficiencies up to approximately 14 %, evaluated by comparison to conventional 3 He detector with known efficiency. These results demonstrate the feasibility of cost-effective, lightweight and robust diamond scintillation detectors for applications in space and planetary science, nuclear security, safeguards and environmental monitoring requiring efficient, robust, gamma-blind neutron detectors.

47 OTHER INSTRUMENTATION↗

Design of a Cryogenic Scintillation Neutrino Detector at the Spallation Neutron Source

We successfully verified in the following three aspects the feasibility of using a cryogenic scintillating crystal-based neutrino detector at the Spallation Neutron Source (SNS), Oak Ridge National Laboratory, for the detection of low-mass dark matter particles and non-standard neutrino interactions (NSIs), as part of the detector R&D effort of the COHERENT experiment. First, we demonstrated the possibility of using silicon photomultipliers (SiPMs) at cryogenic temperatures to replace traditional photomultiplier tubes (PMTs) as light sensors. Second, we verified that the high light yield of undoped CsI crystals measured above 13 keVee at 77 K still holds down to 5.9 keVee. Third, we successfully measured nuclear quenching factor of undoped cryogenic CsI at the Triangle Universities Nuclear Laboratory with the help from our Duke collaborators. The first achievement resulted in a publication in European Physics Journal C. The second resulted in an arXiv pre-print, which is under journal review. The last one indicates that the performance of the proposed detector may be better than what was assumed in the literature. The analysis is in the final stage and will result in another journal publication. In addition, two graduate students involved in this project graduated with master’s degrees during the project period. Both decided to continue their research as PhD students. One open-source data analysis code package was created and is publicly available on GitHub. A set of tutorials about Monte Carlo simulation of radiation interacting with detectors were created on YouTube, receiving more than 100,000 views.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Materials for Gamma Radiation Sensors

Sensors used for spectroscopic measurements of gamma radiation are most often scintillator or semiconductor materials. An overview is provided in this chapter on the materials and development techniques used in producing spectroscopic gamma radiation sensors. Challenges that prevent a perfect sensor are discussed along with the reasons why some sensor materials are ubiquitous despite their performance limitations. The types of sensors commonly used as detectors are discussed along with their key physical properties and electronic characteristics. Materials commonly utilized in radiation detectors are then reviewed to highlight how sensor materials have advanced since the earliest gamma detectors were developed

Johns, Paul M.↗

Gravitational Wave Astrophysics: Opening the New Frontier

The gravitational wave window onto the universe is expected to open in ~ 5 years, when ground-based detectors make the first detections in the high-frequency regime. Gravitational waves are ripples in spacetime produced by the motions of massive objects such as black holes and neutron stars. Since the universe is nearly transparent to gravitational waves, these signals carry direct information about their sources such as masses, spins, luminosity distances, and orbital parameters through dense, obscured regions across cosmic time. This article explores gravitational waves as cosmic messengers, highlighting key sources, detection methods, and the astrophysical payoffs across the gravitational wave spectrum. Keywords: Gravitational wave astrophysics; gravitational radiation; gravitational wave detectors; black holes.

Centrella, Joan↗

Instrumentation for gamma-ray astronomy

The current status of gamma-ray-telescope technology for ground, airborne, and space observations is surveyed and illustrated with drawings, diagrams, and graphs and tables of typical data. For the low- and medium-energy ranges, consideration is given to detectors and detector cooling systems, background-rejection methods, radiation damage, large-area detectors, gamma-ray imaging, data analysis, and the Compton-interaction region. Also discussed are the gamma-ray interaction process at high energies; multilevel automated spark-chamber gamma-ray telescopes; the Soviet Gamma-1 telescope; the EGRET instrument for the NASA Gamma-Ray Observatory; and Cerenkov, air-shower, and particle-detector instruments for the TeV and PeV ranges. Significant improvements in resolution and sensitivity are predicted for the near future.

Bertsch, David L.↗

Searching for the Best Protein Crystals: Synchrotron Based Measurements of Protein Crystal Quality

We are developing X-ray diffraction methods to quantitatively evaluate the quality of protein crystals. The ultimate use for these crystal quality will be to optimize crystal growth and freezing conditions to obtain the best diffraction data. We have combined super fine-phi slicing with highly monochromatic, low divergence synchrotron radiation and the ADSC Quantum 4 CCD detector at the Stanford Synchrotron Radiation laboratory beamline 1.5 to accurately measure crystal mosaicity. Comparisons of microgravity versus earth-grown insulin crystals using these methods will be presented.

Borgstahl, Gloria↗

Discriminating Uranium Isotopes Based on Fission Signatures Induced by Delayed Neutrons

The use of active interrogation to induce delayed neutron emission is a well-established technique for the characterization of special nuclear materials. Delayed neutrons have isotope-characteristic spectral and temporal signatures, which provide the basis for isotope identification. However, in bulk materials that contain an appreciable fissile (e.g., 235 U or 233 U) fraction, such as highly enriched uranium (HEU), delayed neutrons have a high probability of inducing additional fissions. As a result, the overall delayed neutron signature consists of two distinct components: the “primary” delayed neutrons (emitted directly by fission fragments) and the “secondary prompt” fission neutrons produced in fission induced by primary delayed neutrons. These prompt products differ from “primary” delayed neutrons both in their energy spectra and in the presence of coincident radiation released by the parent fission event. The presence and relative quantity of prompt products from delayed fission depend on the cross section of the material in the energy range of delayed neutrons, which may differ significantly between isotopes, thus providing an exploitable means for isotope differentiation. Here, we demonstrate two experimental approaches for discriminating between 235 U and 238 U isotopes based on the measurement of delayed neutron-induced fission products. First, HEU and depleted uranium objects are differentiated through the detection of high-energy prompt neutrons from delayed fission using both recoil-based organic liquid scintillators and thermalization spectra from a custom-built capture-gated composite detector. Secondly, coincident radiation measurements are used as the basis for discrimination by comparing the overall rates and time evolution of fission events when delayed neutrons are present.

07 ISOTOPE AND RADIATION SOURCES↗

Detection of DNA Damage by Space Radiation in Human Fibroblasts Flown on the International Space Station

Space radiation consists of energetic charged particles of varying charges and energies. Exposure of astronauts to space radiation on future long duration missions to Mars, or missions back to the Moon, is expected to result in deleterious consequences such as cancer and comprised central nervous system (CNS) functions. Space radiation can also cause mutation in microorganisms, and potentially influence the evolution of life in space. Measurement of the space radiation environment has been conducted since the very beginning of the space program. Compared to the quantification of the space radiation environment using physical detectors, reports on the direct measurement of biological consequences of space radiation exposure have been limited, due primarily to the low dose and low dose rate nature of the environment. Most of the biological assays fail to detect the radiation effects at acute doses that are lower than 5 centiSieverts. In a recent study, we flew cultured confluent human fibroblasts in mostly G1 phase of the cell cycle to the International Space Station (ISS). The cells were fixed in space after arriving on the ISS for 3 and 14 days, respectively. The fixed cells were later returned to the ground and subsequently stained with the gamma-H2AX (Histone family, member X) antibody that are commonly used as a marker for DNA damage, particularly DNA double strand breaks, induced by both low-and high-linear energy transfer radiation. In our present study, the gamma-H2AX (Histone family, member X) foci were captured with a laser confocal microscope. To confirm that some large track-like foci were from space radiation exposure, we also exposed, on the ground, the same type of cells to both low-and high-linear energy transfer protons, and high-linear energy transfer Fe ions. In addition, we exposed the cells to low dose rate gamma rays, in order to rule out the possibility that the large track-like foci can be induced by chronic low-linear energy transfer radiation.

Lu, Tao↗

Neutrino Beam Monitoring

Accelerator facilities produce neutrino beams from meson decays in a decay volume. Experiments measure event rates that depend on flux, cross sections, and detector response, so the flux is predicted using hadron production and beamline modeling and constrained by beam instrumentation, since near detectors alone cannot separate flux from cross section. Proton, hadron, and muon monitors can track the parent particle distributions and beam conditions, providing the inputs needed for flux predictions in long-baseline experiments such as NOvA, T2K, and DUNE. This talk reviews how beam monitors are used in practice to understand neutrino flux. Proton beam monitors tell where the beam hits the target and how stable it is. Farther downstream, hadron and muon monitors sample particles produced in meson decays. Because those muons come from the same parents as the neutrinos, their profiles reveal focusing, alignment shifts, and other changes in the beam, and they are routinely used to detect problems and guide flux predictions. The muon information can be used more quantitatively; for example, to infer the parent meson phase space, and fast radiation-hard timing detectors can add sensitivity to the momentum dependence of the focusing. These developments show both how tightly beam measurements can constrain the flux and where the current limits still lie. These approaches complement monitored-beam concepts, in which the decay region is instrumented to detect charged leptons from meson decays and to measure the neutrino flux directly.

Ganguly, Sudeshna [Fermilab] (ORCID:00000003163482↗

Neutrino Beam Monitoring

Accelerator facilities produce neutrino beams from meson decays in a decay volume. Experiments measure event rates that depend on flux, cross sections, and detector response, so the flux is predicted using hadron production and beamline modeling and constrained by beam instrumentation, since near detectors alone cannot separate flux from cross section. Proton, hadron, and muon monitors can track the parent particle distributions and beam conditions, providing the inputs needed for flux predictions in long-baseline experiments such as NOvA, T2K, and DUNE. This talk reviews how beam monitors are used in practice to understand neutrino flux. Proton beam monitors tell where the beam hits the target and how stable it is. Farther downstream, hadron and muon monitors sample particles produced in meson decays. Because those muons come from the same parents as the neutrinos, their profiles reveal focusing, alignment shifts, and other changes in the beam, and they are routinely used to detect problems and guide flux predictions. The muon information can be used more quantitatively; for example, to infer the parent meson phase space, and fast radiation-hard timing detectors can add sensitivity to the momentum dependence of the focusing. These developments show both how tightly beam measurements can constrain the flux and where the current limits still lie. These approaches complement monitored-beam concepts, in which the decay region is instrumented to detect charged leptons from meson decays and to measure the neutrino flux directly.

Ganguly, Sudeshna [Fermilab] (ORCID:00000003163482↗

Earth radiation budget measurement from a spinning satellite: Conceptual design of detectors

The conceptual design, sensor characteristics, sensor performance and accuracy, and spacecraft and orbital requirements for a spinning wide-field-of-view earth energy budget detector were investigated. The scientific requirements for measurement of the earth's radiative energy budget are presented. Other topics discussed include the observing system concept, solar constant radiometer design, plane flux wide FOV sensor design, fast active cavity theory, fast active cavity design and error analysis, thermopile detectors as an alternative, pre-flight and in-flight calibration plane, system error summary, and interface requirements.

Sromovsky, L. A.↗

Low-energy radiative backgrounds in CCD-based dark-matter detectors

The reach of sub-GeV dark-matter detectors is at present severely affected by low-energy events from various origins. We present the theoretical methods to compute the single- and few-electron events that arise from secondary radiation emitted by high-energy particles as they pass through detector materials and perform a detailed simulation to quantify them at (Skipper) CCD-based experiments, focusing on the SENSEI data collected at Fermilab near the MINOS cavern. The simulations account for the generation of secondaries from Cherenkov and luminescent recombination radiation; photo-absorption in the bulk, backside layer, pitch adapter, and epoxy; the photon reflection and refraction at interfaces; thin-film interference; the roughness of the interfaces; the dynamics of charges produced in the highly doped CCD-backside-layers; and the partial charge collection on the CCD backside. We consider several systematic uncertainties, notably those stemming from the backside modeling, which we estimate with a “fiducial” and an “extreme” charge-diffusion model, with the former model being preferred due to better agreement with partial-charge collection data. We find that Cherenkov photons constitute about 30% of the observed single-electron events for both diffusion models; radiative recombination contributes negligibly to the event rate for the fiducial model, although it can dominate over Cherenkov for the extreme model. We also estimate the fraction of 2-electron events that arise from 1-electron event coincidences in the same pixel, finding that the entire 2-electron rate can be explained by coincidences of radiative events and spurious charge. Accounting for both radiative and non-radiative backgrounds, we project the sensitivity of future Skipper-CCD-based experiments to different dark-matter models. For light-mediator models with dark-matter masses of 1, 5, and 10 MeV, we find that future experiments with 10-kg-year exposures and successful background mitigation could have a sensitivity that is larger by 9, 3, and 2 orders of magnitude, respectively, when compared to an experiment without background improvements.

79 ASTRONOMY AND ASTROPHYSICS↗