Position annihilation radiation from neutron stars

Matter accreted on the surfaces of neutron stars consists of energetic particles of a few tens to a couple hundred MeV/nucleon, depending on the neutron star mass. In addition to heat, such particles produce nuclear reactions with the surface material. It is proposed that the recently observed 473 + or - 30 keV spectral feature from the galactic center is gravitationally red-shifted positron annihilation radiation produced at the surfaces of old neutron stars. The principal observational tests of the model would be the detection of nuclear gamma ray lines from the galactic center and red-shifted positron annihilation radiation from the galactic disk.

Ramaty, R.↗

Non-Targeted Effects and the Dose Response for Heavy Ion Tumorigenesis

BACKGROUND: There is no human epidemiology data available to estimate the heavy ion cancer risks experienced by astronauts in space. Studies of tumor induction in mice are a necessary step to estimate risks to astronauts. Previous experimental data can be better utilized to model dose response for heavy ion tumorigenesis and plan future low dose studies. DOSE RESPONSE MODELS: The Harderian Gland data of Alpen et al.[1-3] was re-analyzed [4] using non-linear least square regression. The data set measured the induction of Harderian gland tumors in mice by high-energy protons, helium, neon, iron, niobium and lanthanum with LET s ranging from 0.4 to 950 keV/micron. We were able to strengthen the individual ion models by combining data for all ions into a model that relates both radiation dose and LET for the ion to tumor prevalence. We compared models based on Targeted Effects (TE) to one motivated by Non-targeted Effects (NTE) that included a bystander term that increased tumor induction at low doses non-linearly. When comparing fitted models to the experimental data, we considered the adjusted R2, the Akaike Information Criteria (AIC), and the Bayesian Information Criteria (BIC) to test for Goodness of fit.In the adjusted R2test, the model with the highest R2values provides a better fit to the available data. In the AIC and BIC tests, the model with the smaller values of the summary value provides the better fit. The non-linear NTE models fit the combined data better than the TE models that are linear at low doses. We evaluated the differences in the relative biological effectiveness (RBE) and found the NTE model provides a higher RBE at low dose compared to the TE model. POWER ANALYSIS: The final NTE model estimates were used to simulate example data to consider the design of new experiments to detect NTE at low dose for validation. Power and sample sizes were calculated for a variety of radiation qualities including some not considered in the Harderian Gland data set and with different background tumor incidences. We considered different experimental designs with varying number of doses and varying low doses dependant on the LET of the radiation. The optimal design to detect a NTE for an individual ion had 4 doses equally spaced below a maximal dose where bending due to cell sterilization was < 2%. For example at 100 keV/micron we would irradiate at 0.03 Gy, 0.065 Gy, 0.13 Gy, and 0.26 Gy and require 850 mice including a control dose for a sensitivity to detect NTE with 80% power. Sample sizes could be improved by combining ions similar to the methods used with the Harderian Gland data.

Chappelli, Lori J.↗

Upper limit set for level of lightning activity on Titan

Because optically thick cloud and haze layers prevent lightning detection at optical wavelength on Titan, a search was conducted for lightning-radiated signals (spherics) at radio wavelengths using the planetary radioastronomy instrument aboard Voyager 1. Given the maximum ionosphere density of about 3000/cu cm, lightning spherics should be detectable above an observing frequency of 500 kHz. Since no evidence for spherics is found, an upper limit to the total energy per flash in Titan lightning of about 10 to the 6th J, or about 1000 times weaker than that of typical terrestrial lightning, is inferred.

Desch, M. D.↗

Rejoining of isochromatid breaks induced by heavy ions in G2-phase normal human fibroblasts

We reported previously that exposure of normal human fibroblasts in G2 phase of the cell cycle to high-LET radiation produces a much higher frequency of isochromatid breaks than exposure to gamma rays. We concluded that an increase in the production of isochromatid breaks is a signature of initial high-LET radiation-induced G2-phase damage. In this paper, we report the repair kinetics of isochromatid breaks induced by high-LET radiation in normal G2-phase human fibroblasts. Exponentially growing human fibroblasts (AG1522) were irradiated with gamma rays or energetic carbon (290 MeV/nucleon), silicon (490 MeV/nucleon), or iron (200 MeV/nucleon) ions. Prematurely condensed chromosomes were induced by calyculin A after different postirradiation incubation times ranging from 0 to 600 min. Chromosomes were stained with Giemsa, and aberrations were scored in cells at G2 phase. G2-phase fragments, the result of the induction of isochromatid breaks, decreased quickly with incubation time. The curve for the kinetics of the rejoining of chromatid-type breaks showed a slight upward curvature with time after exposure to 440 keV/microm iron particles, probably due to isochromatid-isochromatid break rejoining. The formation of chromatid exchanges after exposure to high-LET radiation therefore appears to be underestimated, because isochromatid-isochromatid exchanges cannot be detected. Increased induction of isochromatid breaks and rejoining of isochromatid breaks affect the overall kinetics of chromatid-type break rejoining after exposure to high-LET radiation.

NASA Center JSC↗

ISS Ammonia Leak Detection Through X-Ray Fluorescence

Ammonia leaks are a significant concern for the International Space Station (ISS). The ISS has external transport lines that direct liquid ammonia to radiator panels where the ammonia is cooled and then brought back to thermal control units. These transport lines and radiator panels are subject to stress from micrometeorites and temperature variations, and have developed small leaks. The ISS can accommodate these leaks at their present rate, but if the rate increased by a factor of ten, it could potentially deplete the ammonia supply and impact the proper functioning of the ISS thermal control system, causing a serious safety risk. A proposed ISS astrophysics instrument, the Lobster X-Ray Monitor, can be used to detect and localize ISS ammonia leaks. Based on the optical design of the eye of its namesake crustacean, the Lobster detector gives simultaneously large field of view and good position resolution. The leak detection principle is that the nitrogen in the leaking ammonia will be ionized by X-rays from the Sun, and then emit its own characteristic Xray signal. The Lobster instrument, nominally facing zenith for its astrophysics observations, can be periodically pointed towards the ISS radiator panels and some sections of the transport lines to detect and localize the characteristic X-rays from the ammonia leaks. Another possibility is to use the ISS robot arm to grab the Lobster instrument and scan it across the transport lines and radiator panels. In this case the leak detection can be made more sensitive by including a focused 100-microampere electron beam to stimulate X-ray emission from the leaking nitrogen. Laboratory studies have shown that either approach can be used to locate ammonia leaks at the level of 0.1 kg/day, a threshold rate of concern for the ISS. The Lobster instrument uses two main components: (1) a microchannel plate optic (also known as a Lobster optic) that focuses the X-rays and directs them to the focal plane, and (2) a CCD (charge coupled device) focal plane detector that reads out the position and energy of the X-rays, allowing a determination of the leak location. The effective area of the detection system is approximately 2 cm(exp2) at 1 keV. The Lobster astrophysics instrument, designed for monitoring the sky for Xray transients, gives high sensitivity along with large field of view (30×30deg) and good spatial resolution (1 arc min). This offers a significant benefit for detecting ISS ammonia leaks, since the goal is to localize small leaks as efficiently as possible.

Camp, Jordan↗

Complex Chromosomal Rearrangements Induced in Vivo by Heavy Ions

It has been suggested that the ratio complex/simple exchanges can be used as a biomarker of exposure to high-LET radiation. We tested this hypothesis in vivo, by considering data from several studies that measured complex exchanges in peripheral blood from humans exposed to mixed fields of low- and high-LET radiation. In particular, we studied data from astronauts involved in long-term missions in low-Earth-orbit, and uterus cancer patients treated with accelerated carbon ions. Data from two studies of chromosomal aberrations in astronauts used blood samples obtained before and after space flight, and a third study used blood samples from patients before and after radiotherapy course. Similar methods were used in each study, where lymphocytes were stimulated to grow in vitro, and collected after incubation in either colcemid or calyculin A. Slides were painted with whole-chromosome DNA fluorescent probes (FISH), and complex and simple chromosome exchanges in the painted genome were classified separately. Complex-type exchanges were observed at low frequencies in control subjects, and in our test subjects before the treatment. No statistically significant increase in the yield of complex-type exchanges was induced by the space flight. Radiation therapy induced a high fraction of complex exchanges, but no significant differences could be detected between patients treated with accelerated carbon ions or X-rays. Complex chromosomal rearrangements do not represent a practical biomarker of radiation quality in our test subjects. Copyright 2003 S. Karger AG, Basel.

Ions/adverse effects/therapeutic use↗

Improved gas-pressure transducer

Optically-selective, acoustically-resonant, gas-detecting device is used to measure intensity of radiation-induced pressure variations. Use of diaphragm improves sensitivity and immunity to background noise.

Dimeff, J.↗

Aether drift and the isotropy of the universe

An experiment is proposed which will detect and map the large-angular-scale anisotropies in the 3 deg K primordial black-body radiation with a sensitivity of .0002 deg K and an angular resolution of about 10 deg . It will detect the motion of the earth with respect to the distant matter of the Universe ("Aether Drift"), and will probe the homogeneity and isotropy of the Universe (the "Cosmological Principle"). The experiment will use two Dicke radiometers, one at 33 GHz to detect the cosmic anisotropy, and one at 54 GHz to detect anisotropies in the residual oxygen above the detectors. An upper hatch for the NASA-AMES Earth Survey Aircraft (U-2) is being modified to accept the dual-radiometer system. A few hours of observation should be sufficient to detect an anisotropy.

Muller, R. A.↗

Observations of the Ca/+/ twilight airglow from intermediate layers of ionization

Optical and incoherent scatter radar techniques are applied to detect the presence of Ca(+) in lower thermospheric intermediate layers over Arecibo. The Arecibo 430 MHz radar is used to measure electron densities, and the altitude distribution and density of the calcium ion is inferred from the variation of twilight resonant scattering with solar depression angle. Ca(+) and electron column densities are compared, and results indicate that the composition of low-altitude intermediate layers is 2% Ca(+), which is consistent with rocket mass spectrometer measurements. Fe(+) and Mg(+) ultraviolet resonance lines are not detected from the ground due to ozone absorbing all radiation short of 3000 A, and measurements of the neutral iron resonance line at 3860 A show that an atmospheric continuum may result in overestimations of emission rates at high solar depression angles.

Tepley, C. A.↗

A search for cyclotron maser radiation from substellar and planet-like companions of nearby stars

Several stars within 5 pc have variations in their rectilinear or Keplerian motion that suggest that they have substellar or planetlike companions. However, direct, unambiguous evidence of such companions is difficult to obtain. It is argued that such objects should commonly emit cyclotron maser radiation and that this radiation should be observable with modern radio telescopes. Its detection would confirm the presence of the companions and permit many of the properties of the stars and companions to be derived. A search was made for the cyclotron maser emission from six nearby stars with suspected companions using the VLA at frequencies of 0.33 and 1.4 GHz. None was detected. Typical observing times were 3.5 hr, and typical upper limits were 30 mJy at 0.33 GHz and 0.3 mJy at 1.4 GHz.

Winglee, Robert M.↗

Total solar irradiance measurements by ERB/Nimbus-7 - A review of nine years

The total solar irradiance measurements made by the cavity sensor of the Earth Radiation Budget experiment on the Nimbus-7 spacecraft have detected the sunspot-blocking effect, established the downward trend of the declining solar cycle, and appear to be confirming an upturn in irradiance at the outset of the new cycle. Studies of the measurements' frequency spectra have advanced the interest in helioseismology or mode analysis, and studies of photospheric activity have advanced through the modeling of the sunspot blocking and photospheric brightening vs measured irradiance.

Hickey, John R.↗

Ionized carbon in the Large Magellanic Cloud

The 158 micron 2P3/2-2P1/2 fine-structure transition of C(+) at selected locations in the LMC. The C II emission is most intense toward far-infrared continuum peaks and generally is not seen in positions exhibiting strong CO J = 2-1 radiation. Where both C II and CO emission are detected, the V(LSR) centroids are similar but the C II line is wider. The differences in spatial distribution and spectral shape suggest a more pronounced physical separation between the predominantly neutral atomic and molecular gas regions than is the case in the Galaxy. In the LMC, the intense and extended C II emission near 30 Dor implies a total amount of C(+) several times greater than that of Galactic molecular cloud complexes. An attempt was made to detect the 289 micron J = 9-8 transition of (C-12)O in a few locations. The observed upper intensity limit for N159 implies that moderate density molecular gas fills less than 5 percent of the beam and that most of the low J CO emission comes from lower density gas.

Boreiko, R. T.↗

Surface analysis of anodized aluminum clamps from NASA-LDEF satellite

Surface analysis results of selected anodized aluminum clamps containing black (Z306) and white (A276) paints which received nearly six years of Low Earth Orbit (LEO) exposure on the Long Duration Exposure Facility are reported. Surface analytical techniques, including x-ray photoelectron spectroscopy (XPS), Auger electron spectroscopy (AES), and scanning electron microscopy/energy dispersive analysis by x-ray (SEM/EDAX), showed significant differences in the surface composition of these materials depending upon the position on the LDEF. Differences in the surface composition are attributed to varying amounts of atomic oxygen and vacuum ultraviolet radiation (VUV). Silicon containing compounds were the primary contaminant detected on the materials.

Grammer, H. L.↗