Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Radiation Detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

Calculation of Dose Deposition in 3D Voxels by Heavy Ions

The biological response to high-LET radiation is very different from low-LET radiation, and can be partly attributed to the energy deposition by the radiation. Several experiments, notably detection of gamma-H2AX foci by immunofluorescence, has revealed important differences in the nature and in the spatial distribution of double-strand breaks (DSB) induced by low- and high-LET radiations. Many calculations, most of which are based on amorphous track models with radial dose, have been combined with chromosome models to calculate the number and distribution of DSB within nuclei and chromosome aberrations. In this work, the Monte-Carlo track structure simulation code RITRACKS have been used to calculate directly the energy deposition in voxels (3D pixels). A cubic volume of 5 micrometers of side was irradiated by 1) 450 (1)H+ ions of 300 MeV (LET is approximately 0.3 keV/micrometer) and 2) by 1 (56)Fe26+ ion of 1 GeV/amu (LET is approximately 150 keV/micrometer). In both cases, the dose deposited in the volume is approximately 1 Gy. All energy deposition events are recorded and dose is calculated in voxels of 20 micrometers of side. The voxels are then visualized in 3D by using a color scale to represent the intensity of the dose in a voxel. This simple approach has revealed several important points which may help understand experimental observations. In both simulations, voxels which receive low dose are the most numerous, and those corresponding to electron track ends received a dose which is in the higher range. The dose voxels are distributed randomly and scattered uniformly within the volume irradiated by low-LET radiation. The distribution of the voxels shows major differences for the (56)Fe26+ ion. The track structure can still be seen, and voxels with much higher dose are found in the region corresponding to the track "core". These high-dose voxels are not found in the low-LET irradiation simulation and may be responsible for DSB that are more difficult to repair. By applying a threshold on the dose visualization, voxels corresponding to electron track ends are evidenced and the spatial distribution of voxels is very similar to the distribution of DSB observed in gamma H2AX experiments, even if no chromosomes have been included in the simulation. Furthermore, this work has shown that a significant dose is deposited in voxels corresponding to electron track ends. Since some delta-rays from iron ion can travel several millimeters, they may also be of radiobiological importance.

Plante, Ianik↗

The evaporation of spherical clouds in a hot gas. II - Effects of radiation

The effects of radiation on the evaporation of spherical clouds in a hot medium are considered. The critical cloud radius at which radiative losses balance conductive heating is determined as a function of the external temperature and density. Smaller clouds evaporate, and larger clouds condense. The conditions under which the surfaces of the clouds may be detected are discussed. Net radiative losses for evaporating clouds are calculated, and an effective cooling function for a cloudy medium is obtained. The results may be applied to clouds in supernova remnants, in the interstellar medium, and in clusters of galaxies.

Mckee, C. F.↗

Coronal mass ejections: The long-term variation of their occurrence rate and the solar wind mass flux

Solar Coronal Mass Ejections (CMEs) from the Sun are an important aspect of coronal physics, and a potentially important contributor to the solar wind mass flux. However, despite significant progress in studies of CMEs since their discovery in the early 70's, questions remain about their effects on the interplanetary medium. A study is done of the long-term variations of the occurrence rates of CMEs, of activity tracers related to CMEs, and of the solar wind particle flux. CMEs are most directly detected by scattered electron radiation in white light. To estimate their long-term occurrence frequency and their contributions to the in-ecliptic solar wind mass flux, observed CME rates must be corrected for instrumental duty cycles, detection efficiency out of the plane of the sky, mass detection thresholds, and geometrical considerations. These corrections are evaluated using data on solar CMEs from the spaceborne Skylab, SMM, and SOLWIND coronagraphs and on interplanetary plasma clouds from the HELIOS white light photometers. Variations in the CME rate and the contribution of CMEs to the solar wind mass flux are traced over nearly a complete solar activity cycle.

Webb, David F.↗

Remote Pulsed Laser Raman Spectroscopy System for Detecting Qater, Ice, and Hydrous Minerals

For exploration of planetary surfaces, detection of water and ice is of great interest in supporting existence of life on other planets. Therefore, a remote Raman spectroscopy system was demonstrated at NASA Langley Research Center in collaboration with University of Hawaii for detecting ice-water and hydrous minerals on planetary surfaces. In this study, a 532 nm pulsed laser is utilized as an excitation source to allow detection in high background radiation conditions. The Raman scattered signal is collected by a 4-inch telescope positioned in front of a spectrograph. The Raman spectrum is analyzed using a spectrograph equipped with a holographic super notch filter to eliminate Rayleigh scattering, and a holographic transmission grating that simultaneously disperses two spectral tracks onto the detector for higher spectral range. To view the spectrum, the spectrograph is coupled to an intensified charge-coupled device (ICCD), which allows detection of very weak Stokes line. The ICCD is operated in gated mode to further suppress effects from background radiation and long-lived fluorescence. The sample is placed at 5.6 m from the telescope, and the laser is mounted on the telescope in a coaxial geometry to achieve maximum performance. The system was calibrated using the spectral lines of a Neon lamp source. To evaluate the system, Raman standard samples such as calcite, naphthalene, acetone, and isopropyl alcohol were analyzed. The Raman evaluation technique was used to analyze water, ice and other hydrous minerals and results from these species are presented.

Garcia, Christopher S.↗

Silicate Mineralogy of the Dust in the Inner Coma of Comet C/1995 01 (Hale-Bopp) Pre- and Post-Perihelion

We present 7.6 - 13.3 microns infrared (IR) spectrophotometry (R approx. = 180 - 350) of the 10 microns silicate emission from dust in the inner coma (i.e., within a diameter of 3in.) of comet C/1995 O1 (Hale-Bopp) at four temporal epochs from 1996 October through 1997 June during Hale-Bopp s approach to, arrival at, and recession from perihelion. The HIFOGS spectra at large heliocentric distances exhibit strong emission peaks from 9.9 - 10.1 microns and at 11.2 microns. The HIFOGS spectra of Hale-Bopp taken 1996 October 07 - 14 UT are identical in shape to the ISO SWS spectrum at 2.8 AU obtained on 1996 October 06 UT. Magnesium-rich olivine was unambiguously identified due to presence of the expected 11.2 microns peak along with the matching far-IR 18 microns, 23 microns, and 33 microns peaks in the ISO SWS spectrum. In contrast, to large heliocentric distances, we find that the silicate feature at small heliocentric distances (tau(sub lambda) less than or = 1.7 AU) exhibits strong peaks at 9.3 microns, 9.9 - 10.1 microns, and 11.2 microns, and weak at 10.5 microns and 11.8 microns. We will show that the dramatic increase of the 9.3 microns and 10.0 microns peaks close to perihelion leads to the hypothesis that there are two crystalline grain components with significantly different temperatures. The hotter mineral species (including olivines) radiate over a large range of heliocentric distances at detectable leve!s. The cooler mineral species (pyroxenes) radiate on the Wien side of the blackbody, too faint to detect in the mid-infrared spectra, until close to the sun when this species radiates on the Reyleigh-Jeans tail and becomes apparent. Decomposition of the observed silicate emission features into mineral components through comparison of the height and shape of the silicate feature ("Flux/cont") derived from the cometary spectra, to optical extinctions (Qext) derived from laboratory measurements of terrestrial silicate minerals and interplanetary dust particles (IDPs) is successful for a combination of warm grains (consisting of olivines, amorphous olivines, amorphous pyroxenes, and layer-lattice silicates) and cool grains (crystalline pyroxenes).

Wooden, Diane H.↗

A new water-based scintillator for efficient Cherenkov and scintillation separation

Neutrinos offer a unique window into the world around us, allowing us to probe otherwise unreachable regions like the interior of stars and the depths of the earth, as well as potentially offering a mechanism for monitoring nuclear activity. Both pure-water and organic liquid scintillators have been used as the detection medium of large-scale neutrino detectors. Organic liquid scintillators offer higher sensitivity at lower energies, which is desirable for many applications, but detection of the Cherenkov radiation required for directional sensitivity is very difficult. A possible solution is to use water-based liquid scintillators (WbLSs), where some fraction of the water is replaced with a micellar solution of the liquid scintillator. This can enhance the detection sensitivity beyond that of pure water, without significantly affecting the ability to leverage the topological Cherenkov signature. Very specific scintillation properties are required to achieve this goal: the scintillation decay time should be significantly slower than that of the Cherenkov emission, so timing-based discrimination of Cherenkov light from scintillation can be applied. At the same time, the light yield should be high enough to enhance the overall sensitivity of the detector, but without losing too much of the Cherenkov light. In this study, we report a new water-based liquid scintillation cocktail based on a 9-methylcarbazole fluorescent dye and a linear alkylbenzene solvent. Here, the proposed composition offers 13.8 ns scintillation decay time and 368 nm emission that matches the desired properties.

Wolszczak, Weronika W. [Lawrence Berkeley National↗

Laboratory simulation of Venusian lightning

Evidence of lightning activity in the Venusian atmosphere has been obtained from the Venera 9, 11, and 12 spacecraft, and from the Pioneer Venus Orbiter (PVO). However, a search for optical pulses expected from Venusian lightning using the star sensor on the PVO did not detect any signals. It has been suggested that the star sensor did not detect lightning because Venusian lightning does not radiate in the 500- to 900-nm spectral region detected by the star sensor. In this paper, spectra obtained from a laboratory simulation of Venusian lightning are discussed. Both the laboratory spectrum and the results of a theoretical calculation of line intensities show that Venusian lightning can be expected to radiate strongly in the 600- to 900-nm spectral region. Hence, the failure of the star sensor to detect lightning must be caused by the low flashing rate or by the low intensity of Venusian lightning.

Borucki, W. J.↗

Genetic effects of HZE and cosmic radiation (L-9)

The purpose of our experiment is to detect mutations in Drosophila possibly induced by space radiation during the SL-J mission, so that we will be able to obtain basic information about 'the genetic (mutational) risk of space radiation' which can be used to estimate human risk of cancer induction by space flight. As an example of somatic mutation, we will analyze morphological changes in hair growing on the surface of the wing of an adult fly. A piece of wing consists of about 30 thousand wing cells and in the wild type Drosophila a long single piece of hair is growing on the surface of each wing cell. When Drosophila is exposed to radiation as its early stage of development, such as embryonic stage or larval (maggot) stage, some mutations will appear in the wing hair of the adult fly with a certain low frequency, depending on the radiation dose. Among the mutations, the most frequent one is a change in the number of hairs per cell, that is, usually three or more hairs are coming out from a single wing cell. In the actual SL-J flight, we will install thousands of Drosophila larvae (maggots) into the Space Shuttle Discovery and expose them to space radiation during the 7-day mission. Immediately after the re-entry to the ground, these larvae are expected to develop (emerge) into adult flies. Then the wings will be fixed by ethylalcohol and permanent samples will be prepared. Finally, we will analyze the wing samples microscopically in order to detect mutations.

Ikenaga, Mituo↗

Methods and systems for electromagnetic near-field coherent sensing

The present disclosure may be embodied as methods and/or systems for non-contact measuring of an on-body and/or inside-body motion of an individual. A sensing signal is provided within a near-field coupling range of a motion to be measured. In this way, a measurement signal may be generated as the sensing signal modulated by the motion. The sensing signal may be an ID-modulated signal. In some embodiments, the sensing signal is a backscattered RFID link provided a wireless tag. A downlink signal may be provided to power the wireless tag. The sensing signal may be a harmonic of the downlink signal. The measurement signal is detected. The motion is measured based on the measurement signal. The measurement signal may be detected as far-field radiation after transmission through a source of the motion. The measurement signal may be detected as reflected from a source of the motion as antenna reflection.

Hui, Xiaonan↗

A room-temperature polarization-sensitive CMOS terahertz camera based on quantum-dot-enhanced terahertz-to-visible photon upconversion

Detection of terahertz (THz) radiation has many potential applications, but presently available detectors are limited in many aspects of their performance, including sensitivity, speed, bandwidth and operating temperature. Most do not allow the characterization of THz polarization states. Recent observation of THz-driven luminescence in quantum dots offers a possible detection mechanism via field-driven interdot charge transfer. Here, we demonstrate a room-temperature complementary metal–oxide–semiconductor THz camera and polarimeter based on quantum-dot-enhanced THz-to-visible upconversion mechanism with optimized luminophore geometries and fabrication designs. Besides broadband and fast responses, the nanoslit-based sensor can detect THz pulses with peak fields as low as 10 kV cm–1. A related coaxial nanoaperture-type device shows a to-date-unexplored capability to simultaneously record the THz polarization state and field strength with similar sensitivity.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Ionizing Radiation Sensing with Functionalized and Copper-Coated SWCNT/PMMA Thin Film Nanocomposites

This paper studies the ionizing radiation effects on functionalized single-walled carbon nanotube (SWCNT)/poly(methyl methacrylate) (PMMA) thin-film nanocomposites [SWNT/PMMA]. The functionalized thin-film devices are made of ferrocene-doped SWCNTs, SWCNTs functionalized with carboxylic acid (COOH), and SWCNTs coated/ modified with copper. The nanocomposite was synthesized by the solution blending method and the resulting nanocomposite was spin-cast on interdigitated electrodes (IDEs). A 160 kV X-ray source was used to irradiate the thin film and changes in the electrical resistance of the nanocomposites due to X-rays were measured using a semiconductor device analyzer. Carboxylic acid functionalized and copper-coated SWCNT/PMMA nanocomposite showed a reduced response to X-rays compared to unfunctionalized SWCNT/PMMA nanocomposite. Ferrocene-doped SWCNT showed a higher sensitivity to X-rays at lower dose rates. This is in contrast to a previous study that showed that similar nanocomposites using functionalized multi-walled CNTs (MWCNTs) had demonstrated an improved response to X-rays ionizing radiation compared to unfunctionalized MWCNTs for all dose rates. Electrical measurements were also performed using the Arduino Nano microcontroller. The result showed that a relatively economical, lightweight-designed prototype radiation sensor based on SWCNT/PMMA thin-film devices could be produced by interfacing the devices with a modest microcontroller. This work also shows that by encapsulating the SWCNT/PMMA thin-film device in a plastic container, the effect of ambient humidity can be reduced and the device can still be used to detect X-ray radiation. This study further shows that the sensitivity of SWCNT to X-rays was dependent on both the functionalization of the SWCNT and the dose rate.

36 MATERIALS SCIENCE↗

Microwave Radiation Detector

Direct photon detector responds to microwave frequencies. Method based on trapped-ion frequency-generation standards proposed to detect radio-frequency (RF) radiation at 40.5 GHz. Technique used for directdetection (RF) communication, radar, and radio astronomy.

Lesh, J. R.↗

The First Detection of (O IV) from an Ultraluminous X-Ray Source with Spitzer. 2. Evidence for High Luminosity in Holmberg II ULX

This is the second of two papers examining Spitzer Infrared Spectrograph observations of the ultraluminous X-ray source (ULX) in Holmberg II. Here, we perform detailed photoionization modeling of the infrared lines. Our analysis suggests that the luminosity and morphology of the [Oiv] 25.89 micronmeters emission line is consistent with photoionization by the soft X-ray and far ultraviolet (FUV) radiation from the accretion disk of the binary system and inconsistent with narrow beaming. We show that the emission nebula is matter bounded both in the line-of-sight direction and to the east, and probably radiation-bounded to the west. A bolometric luminosity in excess of 10(exp 40) erg s(exp -1) would be needed to produce the measured [O iv] flux. We use modeling and previously published studies to conclude that shocks likely contribute very little, if at all,to the high-ionization line fluxes observed in the Holmberg II ULX. Additionally, we find that the spectral type of the companion star has a surprisingly strong effect on the predicted strength of the [O iv] emission. This finding could explain the origin of [O iv] in some starburst systems containing black hole binaries.

GALAXIES↗

Depolarization-Measuring Device

Knowledge of radiation in lidar channel enables determination of depolarization ratio. Device rotates lidar return prior to detection, introducing known amount of radiation into perpendicular lidar channel. Knowledge of amount of radiation interpreted in terms of relative optical/electronic gain ratio between data collected by parallel and perpendicular channels and depolarization scattering medium introduced into linearly-parallel-polarized incident beam.

Alvarez, Jose M.↗

Opportunities to Intercalibrate Radiometric Sensors From International Space Station

Highly accurate measurements of Earth's thermal infrared and reflected solar radiation are required for detecting and predicting long-term climate change. We consider the concept of using the International Space Station to test instruments and techniques that would eventually be used on a dedicated mission such as the Climate Absolute Radiance and Refractivity Observatory. In particular, a quantitative investigation is performed to determine whether it is possible to use measurements obtained with a highly accurate reflected solar radiation spectrometer to calibrate similar, less accurate instruments in other low Earth orbits. Estimates of numbers of samples useful for intercalibration are made with the aid of year-long simulations of orbital motion. We conclude that the International Space Station orbit is ideally suited for the purpose of intercalibration.

Roithmayr, C. M.↗

Detection Limits and Near‐Field Ground Motions of Fast and Slow Earthquakes

Abstract We investigate theoretical limits to detection of fast and slow seismic events, and spatial variations of ground motion expected from M 6 earthquakes at short epicentral distances. The analyses are based on synthetic velocity seismograms calculated with the discrete wavenumber method assuming seismic velocities and attenuation properties of the crust in Southern California. The examined source properties include different magnitudes ( M −1.0 to M 6.0), static stress drops (0.1–10 MPa), and slow and fast ruptures (0.1–0.9 of shear wave velocity). For the M 6 events we also consider variations in rise times producing crack‐ and pulse‐type events and different rupture directivities. Slow events produce ground motion with considerably lower amplitude than corresponding regular fast earthquakes with the same magnitude, and hence are significantly more difficult to detect. The static stress drop and slip rise time also affect the maximum radiated seismic motion, and hence event detectability. Apart from geometrical factors, the saturation and depletion of seismic ground motion at short epicentral distances stem from radiation pattern, earthquake size (magnitude, stress drop), and rupture directivity. The rupture velocity, rise time, and directivity affect significantly the spatial pattern of the ground motions. The results can help optimizing detection of slow and fast small earthquakes and understand the spatial distribution of ground motion generated by large events.

58 GEOSCIENCES↗

Signal processing in SETI

It is believed that the Galaxy might contain ten billion potential life sites. In view of the physical inaccessibility of extraterrestrial life on account of the vast distances involved, a logical first step in a search for extraterrestrial intelligence (SETI) appears to be an attempt to detect signals already being radiated. The characteristics of the signals to be expected are discussed together with the search strategy of a NASA program. It is pointed out that all presently planned searches will use existing radio-astronomy antennas. If no extraterrestrial intelligence signals are discovered, society will have to decide whether SETI justifies a dedicated facility of much greater collecting area. Attention is given to a multichannel spectrum analyzer, CW signal detection, pulse detection, the pattern detector, and details of SETI system operation.

Cullers, D. K.↗

Opportunities to Intercalibrate Radiometric Sensors from International Space Station

Highly accurate measurements of Earth's thermal infrared and reflected solar radiation are required for detecting and predicting long-term climate change. Consideration is given to the concept of using the International Space Station to test instruments and techniques that would eventually be used on a dedicated mission, such as the Climate Absolute Radiance and Refractivity Observatory (CLARREO). In particular, a quantitative investigation is performed to determine whether it is possible to use measurements obtained with a highly accurate (0.3%,with 95%confidence) reflected solar radiation spectrometer to calibrate similar, less accurate instruments in other low Earth orbits. Estimates of numbers of samples useful for intercalibration are made with the aid of yearlong simulations of orbital motion. Results of this study support the conclusion that the International Space Station orbit is ideally suited for the purpose of intercalibration between spaceborne sensors.

Intercalibrate↗