Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RADIATION SOURCE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

Beneficial effect of CH foam coating on x-ray emission from laser-irradiated high-Z material

Laser-irradiated Au layer with CH foam coating is investigated numerically. It is found that when coated with under-critical density CH foam more thermal radiation is produced, while less radiation is produced when coated with over-critical density CH foam. The under-critical density CH foam coating, which is heated supersonically and volumetrically by lasers, hampers the expansion of high-Z plasma and helps increase the density and temperature of Au plasma in the radiation zone. It is a practical and simple way to increase the laser x-ray conversion efficiency of hohlraum by coated with low-Z foam of under-critical density. This idea is tested with an experiment in an analogous geometry. The line emission from laser-irradiated Ti layer coated with CH foam was measured, and the increment of x-ray when coated with under-critical density CH foam was found.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Development of X-ray Microscopy at IPOE

In order to meet the different requirements of applications in synchrotron radiation and plasma diagnosis in China, focusing and imaging optics based on Kirkpatrick-Baez (KB) mirrors, compound refractive lenses (CRLs), and multilayer Laue lenses (MLLs) were studied in our lab. A one-dimensional KB microscope using mirrors with a dual-periodic multilayer coating was developed. The multilayer mirror can reflect both 4.75 keV (Ti K-line) and 8.05 keV (Cu K-line) simultaneously, which makes alignment easier. For hard x-ray microscopy, CRL was studied. Using a SU-8 resist planar parabolic CRL, a focal line of 28.8-{mu}m width was obtained. To focus hard x-rays to nanometer levels efficiently, an MLL was fabricated using a WSi{sub 2}/Si multilayer. The MLL consists of 324 alternating WSi{sub 2} and Si layers with a total thickness of 7.9 {mu}m. (Recently, a much thicker multilayer has been deposited with a layer number of n = 1582 and a total thickness of 27 {mu}m.) After deposition, the sample was sliced and polished into an approximate ideal aspect ratio (depth of the zone plate to outmost layer thickness); the measured results show an intact structure remains, and the surface roughness of the cross section is about 0.4 nm after grinding and polishing processes.

43 PARTICLE ACCELERATORS↗

Synchronous (Lock-in) Measurement Techniques for Magnetic Contrast Enhancement in STXM

We have explored the capabilities of synchronous ('lock-in') point detection techniques to enhance the x-ray magnetic circular dichroism (XMCD) contrast in scanning x-ray transmission microscopy (STXM) of magnetic thin-film microstructures. Local absorption contrast, measured synchronously with low-amplitude (<10 Oe) and low-frequency (<200 hz) longitudinal fields perturbing the near-remanent magnetization state, reveal a strong spatial dependence of the response, with a roll-off in frequency response above 200 Hz. In this context, synchronous measurement affords us a basis for imaging the relation between energy loss and the sweeping rate. We speculate that the lock-in approach will be uniquely suited for detailing stochastic and deterministic frequency-dependent events in the process of magnetization reversal.

36 MATERIALS SCIENCE↗

Coherent Cone-Beam X-ray Microscopy

A novel full-field imaging method using the (111) Bragg diffraction of a sub-micron gold crystal as the divergent cone-beam for sample illumination is reported. The divergence of the illumination allows for very high magnification, limited only by the achievable ratio of the crystal-to-sample and sample-to-detector distances. In this case an x-ray magnification of approximately 115 was achieved.

43 PARTICLE ACCELERATORS↗

Controlling the Vapor Transport Crystal Growth of Hg 3 Se 2 I 2 Hard Radiation Detector Using Organic Polymer

The chalcohalide compound Hg 3 Se 2 I 2 with a defect anti-perovskite structure has been demonstrated to be a promising semiconductor for room temperature X- and gamma-ray detection. In this work, we use transport agents during the vapor growth of Hg 3 Se 2 I 2 crystals under gradient temperature profiles to dramatically improve the size and yield of Hg 3 Se 2 I 2 single crystals. Various growth conditions with combinations of organic polymer (polyethylene) with elemental Hg, Se, or 12 are compared. The largest single crystals (with size up to 7 x 5 x 3.5 mm 3 ) were obtained using both polyethylene and excess I-2 as the transport agents. The as-prepared detector devices based on these crystals have excellent photo response to a series of radiation sources, including low flux X-ray source, alpha particles, and gamma-rays. The X-ray induced photocurrent of Hg 3 Se 2 I 2 detectors is 3 orders of magnitude higher than the dark current, indicating excellent X-ray photosensitivity. Under Am-241 alpha particle source (5.5 MeV), the best energy resolution obtained is similar to 8.1%. The Hg 3 Se 2 I 2 device also shows improved detector performance under Co-57 and Cs-137 gamma-ray sources. The improved crystal growth and detector performance using this polymer additive during the vapor transport process further confirms the great potential for the development of Hg 3 Se 2 I 2 for radiation detection.

36 MATERIALS SCIENCE↗

Networked Gamma Radiation System for Tactical Deployment

A networked gamma radiation detection system with directional sensitivity and energy spectral data acquisition capability is being developed by the National Security Technologies, LLC, Remote Sensing Laboratory to support the close and intense tactical engagement of law enforcement who carry out counterterrorism missions. In the proposed design, three clusters of 2" × 4" × 16" sodium iodide crystals (4 each) with digiBASE-E (for list mode data collection) would be placed on the passenger side of a minivan. To enhance localization and facilitate rapid identification of isotopes, advanced smart real-time localization and radioisotope identification algorithms like WAVRAD (wavelet-assisted variance reduction for anomaly detection) and NSCRAD (nuisance-rejection spectral comparison ratio anomaly detection) will be incorporated. We will test a collection of algorithms and analysis that centers on the problem of radiation detection with a distributed sensor network. We will study the basic characteristics of a radiation sensor network and focus on the trade-offs between false positive alarm rates, true positive alarm rates, and time to detect multiple radiation sources in a large area. Empirical and simulation analyses of critical system parameters, such as number of sensors, sensor placement, and sensor response functions, will be examined. This networked system will provide an integrated radiation detection architecture and framework with (i) a large nationally recognized search database equivalent that would help generate a common operational picture in a major radiological crisis; (ii) a robust reach back connectivity for search data to be evaluated by home teams; and, finally, (iii) a possibility of integrating search data from multi-agency responders.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Networked Gamma Radiation Detection System for Rapid Tactical Response

A networked gamma radiation detection system with directional sensitivity and energy spectral data acquisition capability is being developed by the National Security Technologies, LLC, to support the close and intense tactical engagement of law enforcement who carry out counterterrorism missions. In the proposed design, three clusters of 2' × 4' × 16' sodium iodide crystals (4 each) with digiBASE-E (for list mode data collection) would be placed on the passenger side of a minivan. To enhance localization and facilitate rapid identification of isotopes, advanced smart realtime localization and radioisotope identification algorithms like WAVRAD (wavelet-assisted variance reduction for anomaly detection) and NSCRAD (nuisance-rejection spectral comparison ratio anomaly detection) will be incorporated. We are testing a collection of algorithms and analysis on the problem of radiation detection with a distributed sensor network, examining such a network’s associated characteristics, and also the trade-offs between false positive alarm rates, true positive alarm rates, and time to detect multiple radiation sources in a large area. Empirical and simulation analyses of critical system parameters, such as number of sensors, sensor placement, and sensor response functions, are being examined. This networked system will provide an integrated radiation detection architecture and framework with (i) a large nationally recognized search database equivalent that would help generate a common operational picture in a major radiological crisis; (ii) a robust reach back connectivity for search data to be evaluated by home teams; and, finally, (iii) a possibility of integrating search data from multi-agency responders.

false alarm rate↗

Experimental evidence for beta-decay as a source of chirality by enantiomer analysis

Earlier experiments testing the Vester-Ulbricht beta-decay hypothesis for the origin of molecular chirality are reviewed, followed by descriptions of experiments involving attempted asymmetric radiolysis of DL-amino acids using quantitative gas chromotography as a probe for optical activity. The radiation sources included Sr-90-Y-90, C-14, and P-32 Bremsstrahlen, longitudinally polarized electrons from a linear accelerator and longitudinally polarized protons from a cyclotron. With the possible exception of the linear accelerator irradiations, these experiments failed to produce g.c.-detectable enantiomeric excesses, even at 50-70 percent gross radiolysis. Thus no unambiguous support for the Vester-Ulbricht hypothesis is found in any of the attempted asymmetric radiolyses performed to date. Radioracemization, a possible reason for these failures, is discussed.

Bonner, W. A.↗

Multispectral glancing incidence X-ray telescope

A multispectural glancing incidence X-ray telescope is illustrated capable of broadband, high-resolution imaging of solar and stellar X-ray and extreme ultraviolet radiation sources which includes a primary optical system preferably of the Wolter I type having a primary mirror system. The primary optical system further includes an optical axis having a primary focus at which the incoming radiation is focused by the primary mirrors. A plurality of ellipsoidal mirrors are carried at an inclination to the optical axis behind the primary focus. A rotating carrier is provided on which the ellipsoidal mirrors are carried so that a desired one of the ellipsoidal mirrors may be selectively positioned in front of the incoming radiation beam. In the preferred embodiment, each of the ellipsoidal mirrors has an identical concave surface carrying a layered synthetic microstructure coating tailored to reflect a desired wavelength of 1.5A or longer. Each of the identifical ellipsoidal mirrors has a second focus at which a detector is carried. Thus the different wavelength image is focused upon the detector irregardless of which mirror is positioned in front of the radiation beam.

Hoover, R. B.↗

A theory of ionospheric thermal radiation.

Ionosphere as anisotropic dissipative medium where charged particles random thermal motion acts as thermal radiation source, noting relation between driven AC conduction current density and applied AC electric field intensity

IONOSPHERE↗

Total-body irradiation with high-LET particles: acute and chronic effects on the immune system

Although the immune system is highly susceptible to radiation-induced damage, consequences of high linear energy transfer (LET) radiation remain unclear. This study evaluated the effects of 0.1 gray (Gy), 0.5 Gy, and 2.0 Gy iron ion (56Fe(26)) radiation on lymphoid cells and organs of C57BL/6 mice on days 4 and 113 after whole body exposure; a group irradiated with 2.0 Gy silicon ions (28Si) was euthanized on day 113. On day 4 after 56Fe irradiation, dose-dependent decreases were noted in spleen and thymus masses and all major leukocyte populations in blood and spleen. The CD19(+) B lymphocytes were most radiosensitive and NK1.1(+) natural killer (NK) cells were most resistant. CD3(+) T cells were moderately radiosensitive and a greater loss of CD3(+)/CD8(+) T(C) cells than CD3(+)/CD4(+) T(H) cells was noted. Basal DNA synthesis was elevated on day 4, but response to mitogens and secretion of interleukin-2 and tumor necrosis factor-alpha were unaffected. Signs of anemia were noted. By day 113, high B cell numbers and low T(C) cell and monocyte percents were found in the 2.0 Gy 56Fe group; the 2.0 Gy 2)Si mice had low NK cells, decreased basal DNA synthesis, and a somewhat increased response to two mitogens. Collectively, the data show that lymphoid cells and tissues are markedly affected by high linear energy transfer (LET) radiation at relatively low doses, that some aberrations persist long after exposure, and that different consequences may be induced by various densely ionizing particles. Thus simultaneous exposure to multiple radiation sources could lead to a broader spectrum of immune dysfunction than currently anticipated.

NASA Discipline Radiation Health↗

Surface pyrometry in presence of radiation from other sources with application to turbine blade temperature measurement

Surface pyrometry is feasible even when the amount of surface radiation is exceeded by radiation from surrounding sources. To measure and correct for this interfering radiation, several methods that use multiple wavelength pyrometry were compared by an error analysis. For a specific application to turbine blade temperature measurement in a turbofan engine, a two wavelength method was best. Auxiliary measurements at the same wavelengths substantially improve the accuracy of the method.

Buchele, D. R.↗

Application of Partially coherent Wavefront Propagation Calculations for Design of Coherence-Preserving Synchrotron Radiation Beamlines

Ultra-low emittance third-generation synchrotron radiation (SR) sources, such as NSLS-II and MAX-IV, will offer excellent opportunities for further development of experimental techniques exploiting X-ray coherence. However, even in these new SR sources, the radiation produced by relativistic electrons (in undulators, wigglers and bending magnets) will remain only partially coherent in the X-ray spectral range. 'Extraction' of 'coherent portion' of the radiation flux and its transport to sample without loss of coherence must be performed by dedicated SR beamlines, optimized for particular types of experiments. Detailed quantitative prediction of partially coherent X-ray beam properties at propagation through optical elements, which is required for the optimization of such beamlines, can only be obtained from accurate and efficient physical-optics based numerical simulations. Examples of such simulations, made for NSLS-II beamlines, using 'Synchrotron Radiation Workshop' (SRW) computer code, are presented. Special attention is paid to the numerical analysis of the basic properties of partially coherent undulator radiation beam and its distinctions from the Gaussian beam. Performance characteristics of importance for particular beamlines, such as radiation spot size and flux at sample vs size of secondary source aperture for high-resolution microscopy beamlines, are predicted by the simulations.

43 PARTICLE ACCELERATORS↗

Application of partially coherent wavefront propagation calculations for design of coherence-preserving synchrotron radiation beamlines

Ultra-low emittance third-generation synchrotron radiation (SR) sources, such as NSLS-II and MAX-IV, will offer excellent opportunities for further development of experimental techniques exploiting X-ray coherence. However, even in these new SR sources, the radiation produced by relativistic electrons (in undulators, wigglers and bending magnets) will remain only partiallycoherent in the X-ray spectral range. 'Extraction' of 'coherent portion' of the radiation flux and its transport to sample without loss of coherence must be performed by dedicated SR beamlines, optimized for particular types of experiments. Detailed quantitative prediction of partially coherent X-ray beam properties at propagation through optical elements, which is required for the optimization of such beamlines, can only be obtained from accurate and efficient physical-optics based numerical simulations. Examples of such simulations, made for NSLS-II beamlines, using 'Synchrotron Radiation Workshop' (SRW) computer code, are presented. Special attention is paid to the numerical analysis of the basic properties of partially coherent undulator radiation beam and its distinctions from the Gaussian beam. Performance characteristics of importance for particular beamlines, such as radiation spot size and flux at sample vs size of secondary source aperture for high-resolution microscopy beamlines, are predicted by the simulations.

43 PARTICLE ACCELERATORS↗

Fabrication and Testing of 18-mm-Period, 0.5-m-Long Nb 3 Sn Superconducting Undulator

The Advanced Photon Source at Argonne National Laboratory, in collaboration with FNAL and LBNL, is developing a Nb 3 Sn superconducting undulator with the goal of installing this device on the APS storage ring and providing APS users with the novel radiation source. A series of short, similar to ~ 8-cm-long, 18-mm-period undulator prototype magnets have been designed, fabricated, and tested. The same design was scaled to fabricate a 0.5-m-long undulator prototype. Tests of this prototype showed that the designed peak magnetic field of 1.2 T at 850 A was successfully achieved. It represents at least a 20% improvement in comparison with a NbTi SCU having the same period and magnetic gap. Test results and lessons learned from the design process are reported here.

43 PARTICLE ACCELERATORS↗

Polymorphism and structure of Nd{sub 2}MоO{sub 6} single crystals

The tetragonal and monoclinic modifications of Nd{sub 2}MoO{sub 6} single crystals have been investigated by X-ray diffraction. The analysis has been on laboratory sources (2D CCD diffractometers: Xcalibur S (Shared Research Center, Institute of Crystallography, Russian Academy of Sciences) and BRUKER Smart APEX 2 (Shared Research Center, Institute of General and Inorganic Chemistry, Russian Academy of Sciences)) and on a synchrotron radiation source (ESRF, Grenoble, PILATUS@SNBL diffractometer). Local displacements of all atoms in the oxymolybdate structure have been revealed for the first time using electron density difference maps. Possible violation of the translational periodicity in the distribution of Mo and Nd atoms over types is indirectly confirmed, and statistical disorder of oxygen atoms is revealed. The results of the study confirm the previous suggestion that polymorphic transformations occur in oxymolybdates at a very low rate and, apparently, continuously in a wide temperature range. With an increase in temperature, layers undergo ordering according to the cation type as a result of the phase transition from the monoclinic to the tetragonal phase.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Humming Trains in Seismology: An Opportune Source for Probing the Shallow Crust

Abstract Seismologists are eagerly seeking new and preferably low-cost ways to map and track changes in the complex structure of the top few kilometers of the crust. By understanding it better, they can build on what is known regarding important, practical issues. These include telling us whether imminent earthquakes and volcanic eruptions are generating telltale underground signs of hazard, about mitigation of induced seismicity such as from deep injection of wastewater, how the Earth and its atmosphere couple, and where accessible natural resources are. Passive seismic imaging usually relies on blind correlations within extended recordings of Earth’s ceaseless “hum” or coda of well-mixed, small vibrations. In this article, we propose a complementary approach. It is seismic interferometry using opportune sources—specifically ones not stationary in time and moving in a well-understood configuration. Its interpretation relies on an accurate understanding of how these sources radiate seismic waves, precise timing, careful placement of pairs of listening stations, and seismic phase differentiation (surface and body waves). Massive freight trains were only recently recognized as such a persistent, powerful cultural (human activity-caused) seismic source. One train passage may generate a tremor with an energy output of a magnitude 1 earthquake and be detectable for up to 100 km from the track. We discuss the source mechanisms of train tremors and review the basic theory on sources. Finally, we present case studies of body- and surface-wave retrieval as an aid to mineral exploration in Canada and to monitoring of a southern California fault zone. We believe noise recovery from this new signal source, together with dense data acquisition technologies such as nodes or distributed acoustic sensing, will deeply transform our ability to monitor activity in the shallow crust at sharpened resolution in time and space.

Geochemistry & Geophysics↗

Radiobiological Studies Using Cs-137 Gamma or 320 kV X Rays

There are numerous self-shielded research irradiators used in various facilities throughout the United States. The irradiators employ radioactive sources containing either 137 Cs or 60 Co and the irradiators are used for a variety of radiobiological investigations involving cellular and/or animal models. A report from the National Academy of Sciences described security issues associated with particular radiation sources and the desire for their replacement with suitable X-ray irradiators. One possible replacement would be a 320 kV X-ray irradiator. The participants in this research successfully performed in vivo radiobiological studies involving mice exposed to filtered (HVL ≈ 4 mm Cu) 320 kV X rays. Two publications (one published and one submitted at the publishing of this report) documenting key findings are provided in Appendices A and B of this report. The 320 kV X rays were found suitable for in vivo (in mice) cell survival studies and are expected to be suitable for bone marrow transplantation studies using mice but this needs to be experimentally validated.

62 RADIOLOGY AND NUCLEAR MEDICINE↗