Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Proportional counters”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

Performance of NICER Flight X-Ray Concentrator

Neutron star Interior Composition ExploreR (NICER) is a NASA instrument to be onboard International Space Station, which is equipped with 56 pairs of an X-ray concentrator (XRC) and a silicon drift detector for high timing observations. The XRC is based on an epoxy replicated thin aluminum foil X-ray mirror, similar to those of Suzaku and ASTRO-H (Hitomi), but only a single stage parabolic grazing incidence optic. Each has a focal length of 1.085 m and a diameter of 105 mm, with 24 confocally aligned parabolic shells. Grazing incident angles to individual shells range from 0.4 to 1.4 deg. The flight 56 XRCs have been completed and successfully delivered to the payload integration. All the XRC was characterized at the NASA/GSFC 100-m X-ray beamline using 1.5 keV X-rays (some of them are also at 4.5 keV). The XRC performance, effective area and point spread function, was measured by a CCD camera and a proportional counter. The average effective area is about 44 sq cm at 1.5 keV and about 18 sq cm at 4.5 keV, which is consistent with a micro-roughness of 0.5 nm from individual shell reflectivity measurements. The XRC focuses about 91% of X-rays into a 2mm aperture at the focal plane, which is the NICER detector window size. Each XRC weighs only 325 g. These performance met the project requirement. In this paper, we will present summary of the flight XRC performance as well as co-alignment results of the 56 XRCs on the flight payload as it is important to estimate the total effective for astronomical observations.

X-ray concentrator↗

Recent Developments in the Code RITRACKS (Relativistic Ion Tracks)

The code RITRACKS (Relativistic Ion Tracks) was developed to simulate detailed stochastic radiation track structures of ions of different types and energies. Many new capabilities were added to the code during the recent years. Several options were added to specify the times at which the tracks appear in the irradiated volume, allowing the simulation of dose-rate effects. The code has been used to simulate energy deposition in several targets: spherical, ellipsoidal and cylindrical. More recently, density changes as well as a spherical shell were implemented for spherical targets, in order to simulate energy deposition in walled tissue equivalent proportional counters. RITRACKS is used as a part of the new program BDSTracks (Biological Damage by Stochastic Tracks) to simulate several types of chromosome aberrations in various irradiation conditions. The simulation of damage to various DNA structures (linear and chromatin fiber) by direct and indirect effects has been improved and is ongoing. Many improvements were also made to the graphic user interface (GUI), including the addition of several labels allowing changes of units. A new GUI has been added to display the electron ejection vectors. The parallel calculation capabilities, notably the pre- and post-simulation processing on Windows and Linux machines have been reviewed to make them more portable between different systems. The calculation part is currently maintained in an Atlassian Stash® repository for code tracking and possibly future collaboration.

Plante, Ianik↗

Discovery and Modelling of a Flattening of the Positive Cyclotron Line/luminosity Relation in GX 304-1 with RXTE

The Rossi X-ray Timing Explorer (RXTE) observed four outbursts of the accreting Xray binary transient source, GX 304−1 in 2010 and 2011. We present results of detailed 3-100 keV spectral analysis of 69 separate observations, and report a positive correlation between cyclotron line parameters, as well as other spectral parameters, with power-law flux. The cyclotron line energy, width and depth versus flux, and thus luminosity, correlations show a flattening of the relationships with increasing luminosity, which are well described by quasi-spherical or disc accretion that yield the surface magnetic field to be ∼5 × 1012 Gauss. Since HEXTE (High Energy X-ray Timing Experiment) cluster A was fixed aligned with the Proportional Counter Array field of view and cluster B was fixed viewing a background region 1. ◦ 5 off of the source direction during these observations near the end of the RXTE mission, the cluster A background was estimated from cluster B events using HEXTEBACKEST. This made possible the detection of the ∼55 keV cyclotron line and an accurate measurement of the continuum. Correlations of all spectral parameters with the primary 2-10 keV power-law flux reveal it to be the primary driver of the spectral shape. The accretion is found to be in the collisionless shock braking regime.

Rothschild, Richard E.↗

A Precessing Be Disc as a Possible Model for Occultation Events in GX 304-1

We report on the RXTE detection of a sudden increase in the absorption column density, NH, during the 2011 May outburst of GX 304−1. The NH increased up to ∼16 × 10(exp 22) atoms cm(exp −2), which is a factor of 3–4 larger than what is usually measured during the outbursts of GX 304−1 as covered by RXTE. Additionally, an increase in the variability of the hardness ratio as calculated from the energy resolved RXTE-Proportional Counter Array light curves is measured during this time range. We interpret these facts as an occultation event of the neutron star by material in the line of sight. Using a simple 3D model of an inclined and precessing Be disc around the Be-type companion, we are able to qualitatively explain the NH evolution over time. We are able to constrain the Be disc density to be of the order of 10(exp −11)g cm(exp −3). Our model strengthens the idea of inclined Be discs as origin of double-peaked outbursts as the derived geometry allows accretion twice per orbit under certain conditions.

Kühnel, M.↗

X-Ray Spectral and Flux Variability of the Microquasar GRS 1758-258 on Timescales from Weeks to Years

We present the spectral and timing evolution of the persistent black hole X-ray binary GRS 1758-258 based on almost 12 years of observations using the Rossi X-ray Timing Explorer Proportional Counter Array. While the source was predominantly found in the hard state during this time, it entered the thermally dominated soft state seven times. In the soft state GRS 1758-258 shows a strong decline in flux above 3 keV rather than the pivoting flux around 10 keV more commonly shown by black hole transients. In its 3-20 keV hardness intensity diagram, GRS 1758-258 shows a hysteresis of hard and soft state fluxes typical for transient sources in outburst. The RXTE-PCA and RXTE-ASM long-term light curves do not show any orbital modulations in the range of 2 to 30 d. However, in the dynamic power spectra significant peaks drift between 18.47d and 18.04d for the PCA data, while less significant signatures between 19d and 20d are seen for the ASM data as well as for the Swift/BAT data. We discuss different models for the hysteresis behavior during state transitions as well as possibilities for the origin of the long term variation in the context of a warped accretion disk.

Maria Hirsch↗

Long-term Neutron Background Environment Measured by the Dynamic Albedo of Neutrons (DAN) Instrument onboard Mars Science Laboratory (MSL)

The Dynamic Albedo of Neutrons (DAN) instrument onboard Mars Science Laboratory (MSL) consists of a pulsed neutron generator (PNG) and the neutron detector/electronics (DE) module. There are two 3He-proportional counters used in the DE module. One counter is surrounded with a Cd shell enclosure and measures epi-thermal neutrons with >0.4 eV. The second detector does not have a Cd shell enclosure and measures both thermal and epi-thermal neutrons. The main scientific objectives of DAN are two-fold: (1) the primary objective is to measure the bulk hydrogen abundance (in forms of water or hydrated minerals) of the sub-surface and (2) the secondary objective is to measure the background neutron environment at the surface. DAN achieves the first objective by using a pulsed 14 MeV neutron source (ACTIVE mode). Emitted neutrons undergo a series of nuclear interactions with the regolith and lose energy. The DAN DE module then measures the time profile of the neutrons returned from the regolith. Even a small amount of hydrogen, as low as 0.1 weight % in the regolith, can effectively moderate the high energy neutrons [Mitrofanov, et al., ]. The less-moderated (or epi-thermal) neutrons arrive at the detector earlier than the more-moderated (or thermal) neutrons. The shape and magnitude of neutron time profile curves after pulses can be used to estimate the depth distribution of the hydrogen content. When no neutron pulse is used (PASSIVE mode) DAN measures the neutron background environment at the Mars surface. There are two sources of the background neutrons which DAN would measure: one is secondary neutrons generated by galactic cosmic ray (GCR) interactions with atmospheric and surface materials and the other is neutrons from the Multi-Mission Radioisotope Thermoelectric Generator (MMRTG) onboard MSL as a power source. The passive mode data for the first 1300 sols of the MSL mission are presented in this paper. A summary of the DAN surface operation is described by [Mitrofanov et al., 2012; Jun et al., 2013.

Tate, C.↗

Comparison of Approach-to-Critical Results in Current and Pulse Mode for Systems with High Starter Neutron Rates

Reactors and critical assemblies use a variety of detection systems to monitor the neutron population. The count rate is proportional to the neutron flux present at the location of the detector. When such systems are placed external to an assembly, it is often assumed that the relative leakage multiplication will be proportional to the detector count rate (assuming that the source term, system geometry, and detector placement have not changed). Such systems are often used in an approach-to-critical during reactor startup to ensure that the critical configuration is well predicted. Various types of detectors have been used during an approach-to-critical. These include 3 He, BF 3 , ion chambers, fission chambers, and fission foils. Any of these types of systems (or others) should work well when adequate counting statistics are available. These detector systems can be operated in either pulse or current mode. The National Criticality Experiments Research Center (NCERC) has two detection systems that are commonly used in critical assembly operations. The start-up (referred to as "SU" in this work) system is made up of 3 He proportional counters in pulse mode and the linear counter system (referred to as "LC" in this work) consists of compensated ion-chambers in current mode. Typically the SU system is used for approach-to-critical operations and the LC system is only used at/above delayed critical ( k eff = 1). This work investigates the use of the LC system for an approach-to-critical. It has been long hypothesized that such an approach would be feasible for systems with high starter neutron rates.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Rossi-alpha measurements of fast plutonium metal assemblies using organic scintillators

The reactivity and the k-effective multiplication factor (k eff ) of a fissionable assembly are quantities of widespread interest. These values can be inferred from Rossi-alpha measurements of the prompt neutron decay constant (or the inverse:α -1 ). It has been shown that 3 He-gas proportional counter-based detection systems are insensitive to α -1 of fast assemblies (much faster than tens of microseconds). Therefore, it is of interest to investigate fast detection systems such as those based on organic scintillation detectors. In this work, an array of 12 cylindrical, 5.08 cm x 5.08 cm diameter trans-stilbene organic scintillators was used to measure five subcritical assemblies. One assembly was a sphere of approximately 4.5 kg of alpha-phase, weapons-grade plutonium (k eff = 0.773, α -1 = 11.84 ns) known as the BeRP ball encased in a thin stainless-steel clad. The other assemblies used the same encased sphere and 7.62 cm of iron, nickel, copper, or tungsten reflectors (k eff = 0.884, 0.916, 0.924, 0.939, respectively and α -1 = 36.60, 41.56, 49.60, 70.32 ns, respectively). Finally, this work (1) validates Rossi-alpha measurements with organic scintillators by demonstrating good agreement between measurements and simulations; and (2), demonstrates that organic scintillator-based systems are sensitive to α -1 on the order of 10–100 ns.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The S π RIT time projection chamber

The SAMURAI Pion Reconstruction and Ion-Tracker Time Projection Chamber (SπRIT TPC) was designed to enable measurements of heavy ion collisions with the SAMURAI spectrometer at the RIKEN Radioactive Isotope Beam Factory and provide constraints on the Equation of State of neutron-rich nuclear matter. The SπRIT TPC has a 50.5 cm drift length and an 86.4 cm × 134.4 cm 2 pad plane with 12,096 pads that are equipped with the Generic Electronics for TPCs. The SπRIT TPC allows excellent reconstruction of particles and provides isotopic resolution for pions and other light charged particles across a wide range of energy losses and momenta. Here, details of the SπRIT TPC are presented, along with discussion of the TPC performance based on cosmic ray and charged particles emitted in heavy ion collisions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cosmic ray radiography of a human phantom

Cosmic ray muons that reach the earth's surface provide a natural source of radiation that is used for radiography. In this paper, we show that radiography using the cosmic radiation background provides a method that can be used to monitor bulk aspects of human anatomy. We describe a method that can be used to measure changes in patients as a function of time by cosmic ray muon radiography. Modeling shows muon tomography could provide hourly readouts of parameters such as lung density with sufficient sensitivity to detect the time changes in the inflammation of the lungs in, e.g., COVID patients.

60 APPLIED LIFE SCIENCES↗

New precise half-life measurement for the superallowed β+ emitter Ar34

We have measured the half-life of 34 Ar, the parent of a superallowed 0 + → 0 + β transition, to be 0.84646(35) s. With a precision of 0.04%, this result is an essential ingredient needed to complete a third pair of mirror superallowed transitions, 34 Ar → 34 Cl and 34 Cl → 34 S, the ratio of whose ft values would provide the most sensitive test yet of the isospin-symmetry-breaking corrections used to obtain V ud . In a sequence repeated thousands of times, we implanted a very pure 34 Ar beam into tape for 0.7 s, and then rapidly transported the collected source to a shielded 4π proportional gas counter, which detected the decay positrons from the combined decays of 34 Ar and its daughter 34 Cl. The data were analyzed as a linked parent-daughter pair. Our new result replaces one we published 13 years ago.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Instrumental technique in X-ray astronomy

A detailed review of the development of instruments for X-ray astronomy is given with major emphasis on nonfocusing high-sensitivity counter techniques used to detect cosmic photons in the energy range between 0.20 and 300 keV. The present status of X-ray astronomy is summarized together with significant results of the Uhuru observations, and photon interactions of importance for the detection of X-rays in space are noted. The three principal devices used in X-ray astronomy (proportional, scintillation, and solid-state counters) are described in detail, data-processing systems for these devices are briefly discussed, and the statistics of nuclear counting as applied to X-ray astronomy is outlined analytically. Effects of the near-earth X-ray environment and atmospheric gamma-ray production on X-ray detection by low-orbit satellites are considered. Several contemporary instruments are described (proportional-counter systems, scintillation-counter telescopes, modulation collimators), and X-ray astronomical satellite missions are tabulated.

Peterson, L. E.↗

RF to digital converter

Converter can be used for automatic spectrum analysis. Automatic gain amplifier digitizes RF amplitude, and amplifier gain is measured by binary counter. Amount of gain corresponds to signal level and is proportional to count in counter. System can be used to calculate AM and FM modulation index and other parameters of pulse-modulated FM waves.

Flanders, T. E.↗

A European X-ray astrophysics mission

Five instruments (Bragg Spectrometer, Large Area Proportional and Scintillation Counter Detectors, Wide Field X-ray Cameras and a Gamma-Ray Burst Monitor) are discussed and estimates of their performance are given. Their scientific aims are summarized and sample observing programmes are discussed.

Culhane, J. L.↗

Extreme ultraviolet emissions from an aurora.

Two ultraviolet photometers were flown on a Javelin sounding rocket launched from Fort Churchill, Canada, on February 18, 1970, into a weak auroral breakup. The photometers covered the wavelength bands 300-1000 A and 1050-1500 A and observed the aurora while the rocket was above the emitting regions. The observed radiations were found to originate from the visible and X-ray auroral forms recorded by ground-based all-sky cameras and onboard gas proportional X-ray counters. The intensities in the 1050- to 1500-A band were compatible with previous experimental data and available theoretical intensity calculations.

Paresce, F.↗

Method of measuring the thickness of radioactive thin films

Thickness monitor consists of proportional X-ray counter coupled to pulse counting system, copper filter over face of counter, rotatable collimator containing radioactive source, and rotatable shutter. Monitor can be used as integral part of neutron generator. It has been used to measure titanium tritide film thicknesses from 0.1 to 30 micrometers.

Alger, D. L.↗