Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Probes”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

Achieving atomic resolution magnetic dichroism by controlling the phase symmetry of an electron probe

The calculations presented here reveal that an electron probe carrying orbital angular momentum is just a particular case of a wider class of electron beams that can be used to measure electron magnetic circular dichroism (EMCD) with atomic resolution. It is possible to obtain an EMCD signal with atomic resolution by simply breaking the symmetry of the electron probe phase front using the aberration-corrected optics of a scanning transmission electron microscope. The probe’s required phase distribution depends on the sample’s magnetic symmetry and crystal structure. The calculations indicate that EMCD signals that use the electron probe’s phase are as strong as those obtained by nanodiffraction methods.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

WE-G-BRF-09: Force- and Image-Adaptive Strategies for Robotised Placement of 4D Ultrasound Probes

Purpose: To allow continuous acquisition of high quality 4D ultrasound images for non-invasive live tracking of tumours for IGRT, image- and force-adaptive strategies for robotised placement of 4D ultrasound probes are developed and evaluated. Methods: The developed robotised ultrasound system is based on a 6-axes industrial robot (adept Viper s850) carrying a 4D ultrasound transducer with a mounted force-torque sensor. The force-adaptive placement strategies include probe position control using artificial potential fields and contact pressure regulation by a PD controller strategy. The basis for live target tracking is a continuous minimum contact pressure to ensure good image quality and high patient comfort. This contact pressure can be significantly disturbed by respiratory movements and has to be compensated. All measurements were performed on human subjects under realistic conditions. When performing cardiac ultrasound, rib- and lung shadows are a common source of interference and can disrupt the tracking. To ensure continuous tracking, these artefacts had to be detected to automatically realign the probe. The detection is realised by multiple algorithms based on entropy calculations as well as a determination of the image quality. Results: Through active contact pressure regulation it was possible to reduce the variance of the contact pressure by 89.79% despite respiratory motion of the chest. The results regarding the image processing clearly demonstrate the feasibility to detect image artefacts like rib shadows in real-time. Conclusion: In all cases, it was possible to stabilise the image quality by active contact pressure control and automatically detected image artefacts. This fact enables the possibility to compensate for such interferences by realigning the probe and thus continuously optimising the ultrasound images. This is a huge step towards fully automated transducer positioning and opens the possibility for stable target tracking in ultrasoundguided radiation therapy requiring contact pressure of 5–10 N. This work was supported by the Graduate School for Computing in Medicine and Life Sciences funded by Germany's Excellence Initiative [DFG GSC 235/1].

60 APPLIED LIFE SCIENCES↗

Resonant ultrasound spectroscopy probe for in-situ neutron scattering measurements

Resonant ultrasound spectroscopy (RUS) is an efficient, nondestructive technique to study the elastic properties of solids. A low-temperature (2-300 K) probe has been assembled and tested at the NOMAD beamline at the Spallation Neutron Source at Oak Ridge National Laboratory to assess the probe's neutronic properties, data acquisition system, and compatibility with existing sample environment. A case study on a bulk metallic glass, La 65 Cu 20 Al 10 Co 5, served to benchmark both hardware and software developments. The elastic constants of the metallic glass were determined as a function of temperature between 4 and 300 K and were used to guide neutron diffraction measurements at NOMAD. Tracking of a specific RUS peak center frequency and width enabled live monitoring of the sample temperature evolution that lagged thermometry by upwards of 40 K near room temperature. Assembly of a high-temperature (300-875 K) probe is underway and both probes are scheduled to be available to users by late-2021. Our aim is to provide users with live monitoring of an intrinsic variable at the neutron scattering beamlines, in addition to existing controls, to monitor the state of their samples and its elastic moduli and make informed decisions in real time.

Torres, James↗

Anisotropy and probe-medium interactions in the microrheology of nematic fluids.

A theoretical formalism is presented to analyze and interpret microrheology experiments in anisotropic fluids with nematic order. The predictions of that approach are examined in the context of a simple coarse-grained molecular model which is simulated using nonequilibrium molecular dynamics calculations. The proposed formalism is used to study the effect of confinement, the type of anchoring at the probe-particle surface, and the strength of the nematic field on the rheological response functions obtained from probe-particle active microrheology. As expected, a stronger nematic field leads to increased anisotropy in the rheological response of the material. It is also found that the defect structures that arise around the probe particle, which are determined by the type of anchoring and the particle size, have a significant effect on the rheological response observed in microrheology simulations. Independent estimates of the bulk dynamic modulus of the model nematic fluid considered here are obtained from small-amplitude oscillatory shear simulations with Lees Edwards boundary conditions. The results of simulations indicate that the dynamic modulus extracted from particle-probe microrheology is different from that obtained in the absence of the particle, but that the differences decrease as the size of the defect also decreases. Importantly, the results of the nematic microrheology theory proposed here are in much closer agreement with simulations than those from earlier formalisms conceived for isotropic fluids. As such, it is anticipated that the theoretical framework advanced in this study could provide a useful tool for interpretation of microrheology experiments in systems such as liquid crystals and confined macromolecular solutions or gels.

Cordoba, Andres↗

Processing of Ice Cloud In Situ Data Collected by Bulk Water, Scattering, and Imaging Probes: Fundamentals, Uncertainties, and Efforts toward Consistency

Abstract In situ observations of cloud properties made by airborne probes play a critical role in ice cloud research through their role in process studies, parameterization development, and evaluation of simulations and remote sensing retrievals. To determine how cloud properties vary with environmental conditions, in situ data collected during different field projects processed by different groups must be used. However, because of the diverse algorithms and codes that are used to process measurements, it can be challenging to compare the results. Therefore it is vital to understand both the limitations of specific probes and uncertainties introduced by processing algorithms. Since there is currently no universally accepted framework regarding how in situ measurements should be processed, there is a need for a general reference that describes the most commonly applied algorithms along with their strengths and weaknesses. Methods used to process data from bulk water probes, single-particle light-scattering spectrometers and cloud-imaging probes are reviewed herein, with emphasis on measurements of the ice phase. Particular attention is paid to how uncertainties, caveats, and assumptions in processing algorithms affect derived products since there is currently no consensus on the optimal way of analyzing data. Recommendations for improving the analysis and interpretation of in situ data include the following: establishment of a common reference library of individual processing algorithms, better documentation of assumptions used in these algorithms, development and maintenance of sustainable community software for processing in situ observations, and more studies that compare different algorithms with the same benchmark datasets.

54 ENVIRONMENTAL SCIENCES↗

Oxygen torus and its coincidence with EMIC wave in the deep inner magnetosphere: Van Allen Probe B and Arase observations

We investigate the longitudinal structure of the oxygen torus in the inner magnetosphere for a specific event found on 12 September 2017, using simultaneous observations from the Van Allen Probe B and Arase satellites. It is found that Probe B observed a clear enhancement in the average plasma mass (M) up to 3–4 amu at L = 3.3–3.6 and magnetic local time (MLT) = 9.0 h. In the afternoon sector at MLT ~ 16.0 h, both Probe B and Arase found no clear enhancements in M. This result suggests that the oxygen torus does not extend over all MLT but is skewed toward the dawn. Since a similar result has been reported for another event of the oxygen torus in a previous study, a crescent-shaped torus or a pinched torus centered around dawn may be a general feature of the O + density enhancement in the inner magnetosphere. We newly find that an electromagnetic ion cyclotron (EMIC) wave in the H + band appeared coincidently with the oxygen torus. From the lower cutoff frequency of the EMIC wave, the ion composition of the oxygen torus is estimated to be 80.6% H + , 3.4% He + , and 16.0% O + . According to the linearized dispersion relation for EMIC waves, both He + and O + ions inhibit EMIC wave growth and the stabilizing effect is stronger for He + than O + . Therefore, when the H + fraction or M is constant, the denser O + ions are naturally accompanied by the more tenuous He + ions, resulting in a weaker stabilizing effect (i.e., larger growth rate). From the Probe B observations, we find that the growth rate becomes larger in the oxygen torus than in the adjacent regions in the plasma trough and the plasmasphere.

79 ASTRONOMY AND ASTROPHYSICS↗

Rotation-as-fast-axis scanning-probe x-ray tomography: the importance of angular diversity for fly-scan modes

Here, we investigate the effects of angular diversity on image-reconstruction quality of scanning-probe x-ray tomography for both fly- and step-mode data collection. We propose probe-coverage maps as a tool for both visualizing and quantifying the distribution of probe interactions with the object. We show that data sampling with more angular diversity yields better tomographic image reconstruction as long as it does not come at the cost of not covering some voxels in the object. Therefore, for fly-mode data collection, rotation-as-fast-axis (RAFA) trajectories are superior to raster or other non-RAFA trajectories because they allow for the increasing of angular diversity without sacrificing spatial coverage uniformity. In contrast, for step-mode data collection and a fixed measurement budget, increasing angular diversity can come at the cost of not covering some voxels, and may not be desired. This study has implications for how scanning-probe microscopes should be collecting data in order to make the most of limited resources.

47 OTHER INSTRUMENTATION↗

Development of time-domain differential Raman for transient thermal probing of materials

A novel transient thermal characterization technology is developed based on the principles of transient optical heating and Raman probing: time-domain differential Raman. It employs a square-wave modulated laser of varying duty cycle to realize controlled heating and transient thermal probing. Very well defined extension of the heating time in each measurement changes the temperature evolution profile and the probed temperature field at μs resolution. Using this new technique, the transient thermal response of a tipless Si cantilever is investigated along the length direction. A physical model is developed to reconstruct the Raman spectrum considering the temperature evolution, while taking into account the temperature dependence of the Raman emission. By fitting the variation of the normalized Raman peak intensity, wavenumber, and peak area against the heating time, the thermal diffusivity is determined as 9.17 × 10⁻⁵, 8.14 × 10⁻⁵, and 9.51 × 10⁻⁵ m²/s. These results agree well with the reference value of 8.66 × 10⁻⁵ m²/s considering the 10% fitting uncertainty. The time-domain differential Raman provides a novel way to introduce transient thermal excitation of materials, probe the thermal response, and measure the thermal diffusivity, all with high accuracy.

36 MATERIALS SCIENCE↗

X-ray nano-holotomography reconstruction with simultaneous probe retrieval

In conventional tomographic reconstruction, the pre-processing step includes flat-field correction, where each sample projection on the detector is divided by a reference image taken without the sample. When using coherent X-rays as a probe, this approach overlooks the phase component of the illumination field (probe), leading to artifacts in phase-retrieved projection images, which are then propagated to the reconstructed 3D sample representation. The problem intensifies in nano-holotomography with focusing optics, which, due to various imperfections creates high-frequency components in the probe function. Here, we present a new iterative reconstruction scheme for holotomography, simultaneously retrieving the complex-valued probe function. Implemented on GPUs, this algorithm results in 3D reconstruction resolving twice thinner layers in a 3D ALD standard sample measured using nano-holotomography.

Nikitin, Viktor↗

High-energy, low-jitter, narrowband ps probe laser for kHz-rate fs/ps coherent anti-Stokes Raman scattering

Hybrid fs/ps coherent anti-Stokes Raman scattering (CARS) thermometry often utilizes ps probe pulses derived from pulse shaping or spectrally filtering the primary laser source or by synchronization with a low repetition rate external laser. This results in limited energy, spectral resolution, and/or repetition rate of the ps probe. In this work, a master-oscillator power-amplifier (MOPA) laser was synchronized to the oscillator of a Ti:sapphire regenerative amplifier to achieve high-energy (600 µJ), narrowband (58 ps) probe pulses at kHz repetition rates. Furthermore, temporal filtering allows the pulse characteristics to be adjusted for each application. At 25 Torr, relevant to high-speed flows, the kHz-rate MOPA system generated signal-to-noise ratios 3× higher in nitrogen and had improved precision relative to a 10 ps probe derived from spectral filtering and the power-amplifier. The MOPA system also enabled single-shot ro-vibrational hybrid fs/ps CARS thermometry in 650 K heated air.

47 OTHER INSTRUMENTATION↗

Should the Standard Count Be Excluded from Neutron Probe Calibration?

About 6 decades after its introduction, the neutron probe remains one of the most accurate methods for indirect measurement of soil moisture content. Traditionally, the calibration of a neutron probe involves the ratio of the neutron count in the soil to a standard count, which is the neutron count in the fixed environment such as the probe shield or a specially-designed calibration tank. The drawback of this count-ratio-based calibration is that the error in the standard count is carried through to all the measurements. An alternative calibration is to use the neutron counts only, not the ratio, with proper correction for radioactive decay and counting time. To evaluate both approaches, the shield counts of a neutron probe used for three decades were analyzed. The results show that the surrounding conditions have a substantial effect on the standard count. The error in the standard count also impacts the calculation of water storage and could indicate false consistency among replicates. The analysis of the shield counts indicates negligible aging effect of the instrument over a period of 26 years. It is concluded that, by excluding the standard count, the use of the count-based calibration is appropriate and sometimes even better than ratio-based calibration. The count-based calibration is especially useful for historical data when the standard count was questionable or absent

54 ENVIRONMENTAL SCIENCES↗

Department of Energy Project DE-SC0012198: Probing Electron-Molecule Scattering with HHG: Theory and Experiment (Final Report)

The study of the motion of atoms in molecules is important to understanding many areas of physical and life sciences. Such motion occurs on many different times scales, with electronic motion occurring on a sub-femtosecond time scale, and simple vibrational motion in tens to hundreds of femtoseconds. One way to follow such processes in real time is by the use of shortpulsed lasers, and in particular by studying time-resolved photoionization and the related process of high-harmonic generation (HHG). Thus there has been much effort to develop the tools necessary to probe molecular systems using short pulse lasers and understanding the sensitivity of the different possible probes to the time dependent geometric structure as well as the electronic structure of molecules. Our research has particularly focused on the connection between high-field processes and the more traditional weak field photoionization processes. Strong field and weak field processes can be connected through models that involve the same matrix elements. We have demonstrated in our study of HHG from SF 6 that the spectrum is sensitive to the interplay between the angular dependence of the ionization step and recombination step. In our study of rescattering spectroscopy, we have shown that with a combination of experiment and theory, we can use this high-field spectroscopy to determine molecular structure in molecules such as C 2 H 4 . We have also developed new computational tools based on overset grids to enable studies on larger molecular systems which use much more robust numerical approaches so that the resulting code can be a tool that non-specialists can use to study related systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Final report: Mapping Interactions in Hybrid Systems with Active Scanning Probes

This project aimed to study and map interactions between components of hybrid nanodevices using a novel scanning probe approach. To enable this work, we initially constructed a flexible experimental apparatus allowing for simultaneous scanning probe and confocal optical microscopy measurements. This setup was first used for all-optical measurements of nanostructures, with the focus then shifting to hybrid devices in which single coherent electron spins are coupled to micron-scale ferromagnetic elements, which may prove useful for addressing single spins, enhanced sensing, or spin-wave-mediated coupling of spins for quantum information applications. A significant breakthrough was the realization that it is not necessary to fabricate a magnetic structure on a scanning probe – instead a ferromagnetic vortex core can act as an integrated, solid state, scanning probe. The core of the vortex produces a very strong, localized fringe field which can be used analogously to an MFM tip. Unlike a traditional MFM tip, however, the vortex core is scanned within an integrated device (eliminating drift), and can be moved on vastly faster timescales. This approach allows the detailed investigation of interactions between single spins and complex driven ferromagnetic dynamics.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Cross Correlating Cosmological Probes for Stage-IV Surveys

The next few years will be populated with Stage-IV cosmological surveys. This paper forecasts the cosmological information we expect to constrain using probes from the Rubin Observatory Legacy Survey of Space and Time (LSST) and CMB Stage-4 surveys. We explore the effectiveness of different large-scale-structure probes, including the power spectra of galaxy weak lensing, galaxy positions, Cosmic Microwave Background (CMB) lensing, and their cross-correlation. We use correlated lognormal simulations with the expected redshift distribution, number density of galaxies, and noise levels of the LSST survey, as well as CMB-S4 lensing simulations with anticipated noise levels, to obtain the expected error bars of each of the probes. We investigate the constraining power of the cosmological parameters for the individual probes and their combinations in an idealized scenario, where we do not account for astrophysical and observational parameters such as galaxy bias variations and photometric redshift uncertainties.

Gibbins, Grace↗

Globally optimal interferometry with lossy twin Fock probes

Parity or quadratic spin (e.g., J z 2 ) readouts of a Mach–Zehnder (MZ) interferometer probed with a twin Fock (TF) input state allow saturating the optimal sensitivity attainable among all mode-separable states with a fixed total number of particles but only when the interferometer phase θ is near zero. When more general Dicke state probes are used, the parity readout saturates the quantum Fisher information (QFI) at θ = 0, whereas better-than-standard quantum limit performance of the J z 2 readout is restricted to an o ( N ) occupation imbalance. We show that a method of moments readout of two quadratic spin observables J z 2 and J + 2 + J − 2 is globally optimal for Dicke state probes; i.e., the error saturates the QFI for all θ . In the lossy setting, we derive the time-inhomogeneous Markov process describing the effect of particle loss on TF states, showing that the method of moments readout of four at-most-quadratic spin observables is sufficient for globally optimal estimation of θ when two or more particles are lost. The analysis culminates in a numerical calculation of the QFI matrix for distributed MZ interferometry on the four-mode state | N 4 , N 4 , N 4 , N 4 〉 and its lossy counterparts, showing that an advantage for the estimation of any linear function of the local MZ phases θ 1 and θ 2 (compared to independent probing of the MZ phases by two copies of | N 4 , N 4 〉 ) appears when more than one particle is lost.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Focused Electron Beam-Based 3D Nanoprinting for Scanning Probe Microscopy: A Review

Scanning probe microscopy (SPM) has become an essential surface characterization technique in research and development. By concept, SPM performance crucially depends on the quality of the nano-probe element, in particular, the apex radius. Now, with the development of advanced SPM modes beyond morphology mapping, new challenges have emerged regarding the design, morphology, function, and reliability of nano-probes. To tackle these challenges, versatile fabrication methods for precise nano-fabrication are needed. Aside from well-established technologies for SPM nano-probe fabrication, focused electron beam-induced deposition (FEBID) has become increasingly relevant in recent years, with the demonstration of controlled 3D nanoscale deposition and tailored deposit chemistry. Moreover, FEBID is compatible with practically any given surface morphology. In this review article, we introduce the technology, with a focus on the most relevant demands (shapes, feature size, materials and functionalities, substrate demands, and scalability), discuss the opportunities and challenges, and rationalize how those can be useful for advanced SPM applications. As will be shown, FEBID is an ideal tool for fabrication/modification and rapid prototyping of SPM-tipswith the potential to scale up industrially relevant manufacturing.

36 MATERIALS SCIENCE↗

Kelvin Probe Force Microscopy in liquid using Electrochemical Force Microscopy

Conventional closed loop-Kelvin probe force microscopy (KPFM) has emerged as a powerful technique for probing electric and transport phenomena at the solid-gas interface. The extension of KPFM capabilities to probe electrostatic and electrochemical phenomena at the solid–liquid interface is of interest for a broad range of applications from energy storage to biological systems. However, the operation of KPFM implicitly relies on the presence of a linear lossless dielectric in the probe-sample gap, a condition which is violated for ionically-active liquids (e.g., when diffuse charge dynamics are present). Here, electrostatic and electrochemical measurements are demonstrated in ionically-active (polar isopropanol, milli-Q water and aqueous NaCl) and ionically-inactive (non-polar decane) liquids by electrochemical force microscopy (EcFM), a multidimensional (i.e., bias- and time-resolved) spectroscopy method. In the absence of mobile charges (ambient and non-polar liquids), KPFM and EcFM are both feasible, yielding comparable contact potential difference (CPD) values. In ionically-active liquids, KPFM is not possible and EcFM can be used to measure the dynamic CPD and a rich spectrum of information pertaining to charge screening, ion diffusion, and electrochemical processes (e.g., Faradaic reactions). EcFM measurements conducted in isopropanol and milli-Q water over Au and highly ordered pyrolytic graphite electrodes demonstrate both sample- and solvent-dependent features. Finally, the feasibility of using EcFM as a local force-based mapping technique of material-dependent electrostatic and electrochemical response is investigated. The resultant high dimensional dataset is visualized using a purely statistical approach that does not require a priori physical models, allowing for qualitative mapping of electrostatic and electrochemical material properties at the solid–liquid interface.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Van Allen Probes observation of plasmaspheric hiss modulated by injected energetic electrons

Plasmaspheric hiss was observed by Van Allen Probe B in association with energetic electron injections in the outer plasmasphere. The energy of injected electrons coincides with the minimum resonant energy calculated for the observed hiss wave frequency. Interestingly, the variations in hiss wave intensity, electron flux and ultra low frequency (ULF) wave intensity exhibit remarkable correlations, while plasma density is not correlated with any of these parameters. Our study provides direct evidence for the first time that the injected anisotropic electron population, which is modulated by ULF waves, modulates the hiss intensity in the outer plasmasphere. This also implies that the plasmaspheric hiss observed by Van Allen Probe B in the outer plasmasphere ( L > ~5.5) is locally amplified. Meanwhile, Van Allen Probe A observed hiss emission at lower L shells ( < 5), which was not associated with electron injections but primarily modulated by the plasma density. The features observed by Van Allen Probe A suggest that the observed hiss deep inside the plasmasphere may have propagated from higher L shells.

79 ASTRONOMY AND ASTROPHYSICS↗