Physics basis for the reference flat-top plasma scenario in the ST–E1 fusion power plant

As part of the U.S. Department of Energy’s Milestone-Based Fusion Energy Development Program, Tokamak Energy has completed the pre-concept design of the ST–E1 fusion power plant. ST–E1 is envisaged to operate in two phases: a pilot plant phase, targeting sustained net power production of 300 - 500 MWe for a duration >1 hr, followed by a commercial power plant phase targeting steady-state operations and a normalised overnight capital cost of ⩽12 000 $\$$/kWe. The design process adopted was highly iterative, integrating all major plant systems and progressing in a phased fidelity approach. At the pre-conceptual stage, the emphasis has been on exploring the design space, identifying the main system-level trade-offs, and making the key decisions that define the overall plant concept, rather than optimising a single operating point. This paper, part of a focused collection detailing the ST–E1 pre-concept design, addresses the development of a series of reference flat-top plasma operating points for the pilot plant phase. A modelling workflow was established to develop and assess candidate plasma design points and explore key dependencies. The workflow includes integrated core plasma modelling, magnetohydrodynamic (MHD) stability assessment, equilibrium generation, scrape-off-layer and exhaust modelling, heating & current drive design and optimisation, and turbulent transport modelling. Using this framework, the impact of several key parameters on the flat-top operating space was investigated, including the density limit, core radiation fraction and divertor power loading, level of external heating and curent drive power and assumed pedestal characteristics. The MHD stability, controllability and micro-stability characteristics of these plasmas were also analysed. These investigations informed the definition of a set of fully non-inductive, flat-top reference operating points that satisfy the high-level ST–E1 mission, including a low and high density case, a case that is stable to resistive wall modes and a case with reduced divertor power loading.

ST–E1↗

Unraveling small-scale defects in irradiated ThO 2 using kinetic Monte Carlo simulations

Point defects and their clusters generated through irradiation can have significant impact on the physical and mechanical properties of materials. However, direct experimental visualization of these small-scale defects using high-resolution scanning transmission electron microscopy remains a challenging task. In this study, using thorium dioxide (ThO 2 ) with the fluorite structure as a model system, we demonstrate the use of ab initio basin-hopping simulations in synergy with object kinetic Monte Carlo simulations as a powerful tool for identifying small defect complexes in irradiated materials. In addition to providing quantitative insights into defect evolution in ThO 2 under irradiation, our study reveals an unexpected role of bound anti-Schottky defect clusters in mediating defect transport. Remarkably, despite their poor thermal stability against dissociation at high temperatures, the transient formation of bound anti-Schottky defects under irradiation and their subsequent migration provide the dominant mechanism for the growth of large interstitial loops that have been experimentally observed in ThO 2 .

36 MATERIALS SCIENCE↗

Modifying Ionogel Solid-Electrolytes for Complex Electrochemical Systems

The solution processability of ionogel solid electrolytes has recently garnered attention in the Li-ion battery community as a means to address the interface and fabrication issues commonly associated with most solid electrolytes. However, the trapped ionic liquid (ILE) component has hindered the electrochemical performance. In this report we present a process to tune the properties by replacing the ILE in a silica-based ionogel after fabrication with a liquid component befitting the desired application. Electrochemical cycling under various conditions showcases gels containing different liquid components incorporated into LiFePO4 (LFP)/gel/Li cells: high power (455 W kg –1 at a 1 C discharge) systems using carbonates, low temperatures (-40 °C) using ethers, or high temperatures (100 °C) using ionic liquids. Fabrication of additive-manufactured cells utilizing the exchanged carbonate-based system is demonstrated in a planar LFP/Li 4 Ti 5 O 12 (LTO) system, where a marked improvement over an ionogel is found in terms of rate capability, capacity, and cycle stability (118 vs 41 mA h g –1 at C/4). This process represents a promising route to create a separator-less cell, potentially in complex architectures, where the electrolyte properties can be facilely tuned to meet the required conditions for a wide range of battery chemistries while maintaining a uniform electrolyte access throughout cast electrodes.

25 ENERGY STORAGE↗

Implementation of extreme ultraviolet spectroscopy on a sheared-flow-stabilized Z pinch

A diagnostic for extreme ultraviolet spectroscopy was fielded on the sheared-flow-stabilized (SFS) fusion Z-pinch experiment (FuZE-Q) for the first time. The spectrometer collected time-gated plasma emission spectra in the 5–40 nm wavelength (30–250 eV) range for impurity identification, radiative power studies, and for plasma temperature and density measurements. The unique implementation of the diagnostic included fast (10 ns risetime) pulsed high voltage electronics and a multi-stage differential pumping system that allowed the vacuum-coupled spectrometer to collect three independently timed spectra per FuZE-Q shot while also protecting sensitive internal components. Analysis of line emission identifies oxygen (N-, C-, B-, Be-, Li-, and He-like O), peaking in intensity shortly after maximum current (>500 kA). This work provides a foundation for future high energy spectroscopy experiments on SFS Z-pinch devices.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Measuring dynamics of differentially rotating, unmagnetized, free-boundary plasma produced by soft x-ray irradiation

We present results from a new experiment, fielded on the MAGPIE pulsed power generator, producing a rotating, boundary-free plasma with no pre-imposed magnetic field. Angular momentum is introduced to the rotating system by the oblique collision of multiple plasma flows, which are driven by x-ray ablation of solid targets using the soft x-rays emitted from the implosion of wire array z-pinches. This produces a hydrodynamically stable plasma which undergoes ~2-3 rotations over the duration of the experiment, significantly more than previous pulsed-power platforms. Estimating the angular frequency from the electron density profile in the inner part of the rotating plasma shows that it has a quasi-Keplerian rotation profile. The system also allows for the addition of a controllable magnetic field. This, combined with the sufficiently large Reynolds (~10 5 ) and magnetic Reynolds (~10) numbers, will enable investigation of the effect of magnetic field on the structure and stability of the rotating plasma.

Physics - Plasma physics↗

PLEXUS: A Pattern-Oriented Runtime System Architecture for Resilient Extreme-Scale High-Performance Computing Systems

For high-performance computing (HPC) system designers and users, meeting the myriad challenges of next-generation exascale supercomputing systems requires rethinking their approach to application and system software design. Among these challenges, providing resiliency and stability to the scientific applications in the presence of high fault rates requires new approaches to software architecture and design. As HPC systems become increasingly complex, they require intricate solutions for detection and mitigation for various modes of faults and errors that occur in these large-scale systems, as well as solutions for failure recovery. These resiliency solutions often interact with and affect other system properties, including application scalability, power and energy efficiency. Therefore, resilience solutions for HPC systems must be thoughtfully engineered and deployed.In previous work, we developed the concept of resilience design patterns, which consist of templated solutions based on well-established techniques for detection, mitigation and recovery. In this paper, we use these patterns as the foundation to propose new approaches to designing runtime systems for HPC systems. The instantiation of these patterns within a runtime system enables flexible and adaptable end-to-end resiliency solutions for HPC environments. The paper describes the architecture of the runtime system, named Plexus, and the strategies for dynamically composing and adapting pattern instances under runtime control. This runtime-based approach enables actively balancing the cost-benefit trade-off between performance overhead and protection coverage of the resilience solutions. Based on a prototype implementation of PLEXUS, we demonstrate the resiliency and performance gains achieved by the pattern-based runtime system for a parallel linear solver application.

Hukerikar, Saurabh↗

Dynamic land use implications of rapidly expanding and evolving wind power deployment

Abstract The expansion of wind power poses distinct and varied geographic challenges to a sustainable energy transition. However, current knowledge of its land use impacts and synergies is limited by reliance on static characterizations that overlook the role of turbine technology and plant design in mediating interactions with the environment. Here, we investigate how wind technology development and innovation have shaped landscape interactions with social and ecological systems within the United States and contribute to evolving land area requirements. This work assesses trends in key land use facets of wind power using a holistic set of metrics to establish an evidence base that researchers, technology designers, land use managers, and policymakers can use in envisioning how future wind-intensive energy systems may be jointly optimized for clean energy, social, and environmental objectives. Since 2000, we find dynamic land occupancy patterns and regional trends that are driven by advancing technology and geographic factors. Though most historical U.S. wind deployment has been confined to the temperate grassland biome in the nation’s interior, regional expansion has implicated diverse land use and cover types. A large percentage of the typical wind plant footprint (∼96% to > 99%) is not directly impacted by permanent physical infrastructure, allowing for multiple uses in the spaces between turbines. Surprisingly, turbines are commonly close to built structures. Moreover, rangeland and cropland have supported 93.4% of deployment, highlighting potential synergies with agricultural lands. Despite broadly decreasing capacity densities, offsetting technology improvements have stabilized power densities. Land use intensity, defined as the ratio of direct land usage to lifetime power generation of wind facilities, has also trended downwards. Although continued deployment on disturbed lands, and in close proximity to existing wind facilities and other infrastructure, could minimize the extent of impacts, ambitious decarbonization trajectories may predispose particular biomes to cumulative effects and risks from regional wind power saturation. Increased land-use and sustainability feedback in technology and plant design will be critical to sustainable management of wind power.

17 WIND ENERGY↗

PID-Regulated Heating System for PIP-II Reference Line

The Proton Improvement Plan 2 (PIP-II) centers on building a new superconducting linear particle accelerator (Linac) at Fermilab. At the heart of the accelerator is the reference line. It is a critical system that defines the ideal path for the beam as it passes through magnets, RF cavities, and other beamline elements. Temperature stability is crucial for the reliable operation of RF components, such as mixers and filters. Fluctuations affect key performance parameters like conversion loss, isolation, and linearity. To mitigate any drift caused by ambient temperature changes, a heating plate assembly is utilized to maintain key components at a controlled temperature of 40 C. Utilizing an actively regulated heating system, a metal-oxide-semiconductor field-effect transistor (MOSFET) based power control circuit which provides input to a controller; forming a closed-loop system that maintains the desired setpoints with high precision.

Mosher, Alexander [U. Illinois, Chicago]↗

First-Principles Studies on Sc 2 RuZ (Z = Si, Ge, Sn) Inverse Heusler Alloys: Structural, Electronic, and Transport Properties

The continuous demand for efficient, nontoxic, and thermally stable materials for room-temperature energy conversion motivates the exploration of novel thermoelectric systems beyond the traditional magnetic Heusler alloys. While full and half-Heusler compounds, especially Co-, Ni-, and Mn-based systems, have demonstrated promising thermoelectric properties, their typically high operating temperatures and magnetic complexities limit their applicability in ambient thermal management. In this context, we investigate whether Sc-based inverse Heusler alloys can offer a viable nonmagnetic alternative with competitive thermoelectric performance. In this work, we perform a systematic first-principles study of the inverse Heusler compounds Sc 2 RuZ (Z = Si, Ge, Sn), focusing on their structural, electronic, mechanical, and thermodynamic-thermoelectric properties. Density Functional Theory (DFT) was employed to compute optimized lattice structures and band dispersion, while dynamical stability was assessed via phonon calculations. Thermoelectric transport coefficients, including Seebeck coefficient, electrical conductivity, and thermal conductivity, were estimated using the semiclassical Boltzmann transport theory within the constant relaxation time approximation. Our results show that all Sc 2 RuZ compounds are thermodynamically stable semiconductors with indirect band gaps of 0.12–0.16 eV and exhibit high elastic moduli, especially Sc 2 RuSn, which demonstrates superior stiffness and incompressibility. Importantly, all compounds display promising room-temperature thermoelectric characteristics, including high Seebeck coefficients and power factors. These findings reveal that Sc 2 RuZ alloys represent a rare class of stable, nonmagnetic inverse Heusler semiconductors with intrinsic thermoelectric potential at room temperature, unlike many existing Heusler systems optimized for spintronics or high-temperature operation. This work expands the known design space for Heusler-based thermoelectrics and offers a theoretical basis for experimental realization of efficient, low-temperature, nonmagnetic thermoelectric materials.

alloys↗

Evaluating Grid Strength under Uncertain Renewable Generation

The increasing displacement of synchronous generators with renewable resources such as wind and solar via power electronic interfaces causes a reduction in short-circuit strength and weak grid issues. The variation and uncertainty of renewable energy increase challenges for identifying weak grid conditions. This paper proposes an efficient method to analyze the impact of uncertain renewable energy on grid strength. The proposed method uses the probabilistic collocation method (PCM) to approximate the results of grid strength assessment under uncertain renewable generation, in order to reduce computational burden without compromising result accuracy when compared with traditional Monte Carlo simulation (MCS). To improve the accuracy of the approximation results, the proposed method integrates the K-means clustering technique with PCM to select the approximation samples of input variables. The efficacy of the proposed method is demonstrated by comparison with MCS on the modified IEEE 9-bus system and modified IEEE 39-bus system with multiple renewable generators.

grid strength↗

Red-Ox Robust SOFC Stacks for Affordable, Reliable Distributed Generation Power Systems

While SOFC systems are expected to operate reliably and with limited degradation in steady state or transient performance, SOFC stacks may ultimately fail due to the loss of structural integrity of one or several of the cells as a result of the weakening of the materials and interfaces due to physico-chemical changes that occur during continuous operation as a result of plastic and creep deformations, modification of the temperature profile, and/or degradation of the electrochemical performance of the cells. Degradation mechanisms originating from the cell components include coarsening of the microstructure over time; decomposition of materials; chemical reaction of electrode materials with electrolyte at the interface; delamination from each other; and for the anode, coking and sulfur poisoning. Of all the reliability issues that may occur for SOFCs, the main limitation for Ni-based cermet anodes (e.g., NiO-YSZ) is the poor stability during reduction-oxidation (red-ox) cycling. This project was aimed at the development of ceramic anode SOFCs based on SFCM (SrFe0.2Co0.4Mo0.4O3), which is a conductive perovskite that is red-ox stable. Additionally, the project involved the development of a red-ox robust stack. Scale up of SFCM-based cells to a large format (10 cm by 10 cm) cell size was achieved as well as a maximum power density of 0.9 W/cm 2 at 600 °C (>0.6 W/cm 2 at 0.6 V). Up to a 10-cell stack was successfully assembled and demonstrated, and cells showed similar performance in reformed, pipeline natural gas as in hydrogen. Finally, a 3-cell stack was red-ox cycled without degradation for 40 cycles at ~600 °C.

03 NATURAL GAS↗

Data-Driven Linear Parameter-Varying Modeling and Control of Flexible Loads for Grid Services: Preprint

Flexible loads have great potential to improve the power grid's flexibility and stability. To effectively control large ensembles of heterogeneous loads, reliable models thereof are required. The paper presents a data-driven modeling and control approach to manage flexible loads for providing grid services. We leverage a linear parameter-varying autoregressive moving average (LPV-ARMA) model to describe the aggregate load response, where the parameters in the model are used to capture external environment impacts (e.g., weather). A gain-scheduling feedback controller is then developed to adapt to environmental variations. This data-driven approach can be easily applied to different types of loads in various environmental conditions. In addition to the ensemble controller, distributed load controllers are designed to deliver grid services, while maintaining the quality of service of inherent load tasks. We demonstrate the work on the IEEE 37-node distribution system for real-time power regulation services through control of thermostatically controlled loads.

control↗

Bounded Universal Droop Control to Enable the Operation of Power Inverters Under Some Abnormal Conditions and Maintain Voltage and Frequency Within Predetermined Ranges

The universal droop control (UDC) can be applied to power inverters having an impedance angle between -pi/2 rad and pi/2 rad to achieve voltage and frequency regulation and accurate proportional power sharing without the need of knowing the type or value of impedance. However, there is an increasing need for voltage and frequency regulation within predetermined ranges even under some abnormal conditions, such as overloading, sensor faults, and large set-point changes, etc. In this paper, a bounded nonlinear dynamics is introduced into the UDC to ensure that the voltage and frequency can always stay within predetermined ranges under normal and some abnormal conditions, up to hardware limits when current protection needs to be triggered. As a result, the proposed controller can extend the operational range of power inverters in terms of voltage and frequency regulation to cover different scenarios. More importantly, the ranges for both voltage and frequency can be chosen independently from each other. Since the original structure of the UDC is kept in the proposed controller, the properties of the UDC, such as without the need of knowing the type or value of impedance, are well maintained. Furthermore, the closed-loop stability of the system is established via the Lyapunov method. Extensive simulation and experimental results are presented to validate the effectiveness of the proposed controller.

14 SOLAR ENERGY↗

Grid stabilization using adjusted voltage regulator response to grid characteristics

Apparatus and methods are disclosed for control systems for improving stability of electrical grids by temporarily reducing voltage output of electrical generators responsive to transient events on an electrical grid. In one example of the disclosed technology, a controller is coupled is to an automatic voltage regulator, which in turn adjusts excitation current of an electrical generator responsive to changes in frequency detected for the electrical grid. Reducing the output voltage temporarily allows for smaller generators to provide power to the microgrid. Methods for selecting parameters determining how the controller generates a regulation signal used to adjust the excitation current are further disclosed.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Providencia Island White Papers: Hawaii, USA: A Grid Planning Case Study for Providencia Island, Colombia

Special considerations exist for island grids seeking to smoothly integrate distributed energy resources (DERs), such as rooftop photovoltaics (PV), with an existing fossil fuel-based grid without compromising system stability and reliability. Hawaii, having successfully integrated nonconventional renewable energy sources for a hybrid electricity grid, may serve as a guide for technical specifications and interconnection policy. Island grid planners may seek to follow Hawaii's example by standardizing technical specifications of generators, particularly for advanced inverter components.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Cybersecurity Enhancement in Digital Substations: Hidden Markov Model-Based Smart Cyber Switching and Threat Response

The rising incidence of cyber-attacks on critical infrastructure and power grids poses significant threats to the stability and reliability of electrical substations, with potentially devastating consequences such as extended blackouts. This paper introduces an advanced cybersecurity framework aimed at safeguarding IEC 61850-based substations through the integration of software-defined networking (SDN) and digital twin (DT) technologies. The proposed DT-based framework employs smart cyber switching (SCS) for proactive threat mitigation and concurrent intelligent electronic device (CIED) for swift system restoration, thereby maintaining continuous operational integrity and robust cybersecurity defenses. Central to this framework is the adaptive port controller (APC), which enables dynamic port management to adapt to evolving threats, and an intrusion detection system (IDS) designed to detect and neutralize malicious attacks on IEC 61850-based sampled value (SV) and generic object-oriented substation event (GOOSE) messages within the substation’s communication network. Further, novel predictive intrusion detection and response (PIDR) algorithm is implemented on a digital substation (DS) to predict the best route to be taken by the attacker. The efficacy of these comprehensive cybersecurity frameworks is validated through rigorous simulations and a hardware-in-the-loop (HIL) testbed, showcasing the system’s ability to sustain substation operations amidst cyber-attacks.

Digital substation↗

Advancing Grid Resilience through Smart Charge Management: Findings from Maryland’s Pilot

This report presents research findings from a four-year Smart Charge Management (SCM) pilot program conducted by Maryland’s largest electric utilities—Baltimore Gas and Electric (BGE), Potomac Electric Power Company (Pepco), and Delmarva Power & Light (DPL)—to evaluate strategies for optimizing electric vehicle (EV) charging loads and enhancing grid stability. Supported by the U.S. Department of Energy (DOE), Argonne National Laboratory collaborated with all project partners and examined the effectiveness of Time-of-Use (TOU) and Load Balancing (LB) strategies in managing peak demand, deferring costly infrastructure upgrades, and reducing grid constraints at the feeder level. Using charging data from over 4,600 EV drivers, the study analyzed SCM’s impact on the distribution systems of BGE and Pepco, which consists of over 2000 feeders. Unlike prior research that focused on system-wide trends or synthetic feeders, this analysis offers granular, feeder-level insights based on real-world operational data. It highlights how transformer density, load profiles, and infrastructure constraints influence smart charging performance. Results show feeder-level conditions play a crucial role in SCM effectiveness, with most feeders benefiting more from LB, while TOU-based SCM may be sufficient for others. By 2035, LB reduced peak charging loads by 27% on average, compared to 23% under TOU-based SCM, though some feeders saw reductions exceeding 35%, while others experienced minimal impact. Feeders with higher transformer utilization and limited capacity benefited more from LB, which more effectively distributed charging demand during off-peak hours. Beyond reducing grid constraints, SCM offers long-term operational and financial benefits. By shifting EV charging demand strategically, utilities can optimize asset utilization, delay infrastructure investments, and enhance grid performance. In terms of infrastructure upgrade deferrals, at the feeder level, LB consistently reduced peak charging loads and resulting infrastructure upgrade costs, particularly in high EV enrollment areas, decreasing the number of overloaded transformers by up to 35%, while TOU-based SCM achieved 20-30% reductions depending on feeder characteristics. At the system level, LB has the potential to defer total upgrade costs by $\$$186 million for BGE, compared to $\$$159 million under TOU-based SCM. For Pepco, TOU-based SCM performed slightly better, deferring upgrade costs by $\$$30 million, compared to $\$$29 million under LB. Section 4.5 reviews some of the system differences between BGE and Pepco. However, as EV adoption scales, TOU-based SCM will introduce secondary peak charging loads, reinforcing the need for more advanced, adaptive SCM approaches to prevent new grid challenges. As EV adoption continues to grow, feeder-level managed charging strategies will be essential for mitigating grid stress, improving infrastructure efficiency, and maintaining energy affordability for consumers. This report provides critical insights for utilities, Public Utility Commissions (PUCs), and state agencies on the role of feeder-specific smart charging in infrastructure planning, policy development, and grid modernization. The findings underscore the importance of tailored, data-driven SCM solutions that align with local grid conditions, ensuring a resilient, cost-effective transition to increasing EV adoption while safeguarding distribution system performance.

24 POWER TRANSMISSION AND DISTRIBUTION↗