Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Power distribution system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

Performance of a Dynamically Controlled Inverter in a Photovoltaic System Interconnected with a Secondary Network Distribution System

In 2008, a 300 kW{sub peak} photovoltaic (PV) system was installed on the rooftop of the Colorado Convention Center (CCC). The installation was unique for the electric utility, Xcel Energy, as it had not previously permitted a PV system to be interconnected on a building served by the local secondary network distribution system (network). The PV system was installed with several provisions; one to prevent reverse power flow, another called a dynamically controlled inverter (DCI), that curtails the output of the PV inverters to maintain an amount of load supplied by Xcel Energy at the CCC. The DCI system utilizes current transformers (CTs) to sense power flow to insure that a minimum threshold is maintained from Xcel Energy through the network transformers. The inverters are set to track the load on each of the three phases and curtail power from the PV system when the generated PV system current reaches 95% of the current on any phase. This is achieved by the DCI, which gathers inputs from current transformers measuring the current from the PV array, Xcel, and the spot network load. Preventing reverse power flow is a critical technical requirement for the spot network which serve this part of the CCC. The PV system was designed with the expectation that the DCI system would not curtail the PV system, as the expected minimum load consumption was historically higher than the designed PV system size. However, the DCI system has operated many days during the course of a year, and the performance has been excellent. The DCI system at the CCC was installed as a secondary measure to insure that a minimum level of power flows to the CCC from the Xcel Energy network. While this DCI system was intended for localized control, the system could also reduce output percent if an external smart grid control signal was employed. This paper specifically focuses on the performance of the innovative design at this installation; however, the DCI system could also be used for new s- art grid-enabled distribution systems where renewables power contributions at certain conditions or times may need to be curtailed.

14 SOLAR ENERGY↗

Incentive-Based Voltage Regulation in Distribution Networks

This paper considers distribution networks fea- turing distributed energy resources, and designs incentive-based mechanisms that allow the network operator and end-customers to pursue given operational and economic objectives, while concurrently ensuring that voltages are within prescribed limits. Two different network-customer coordination mechanisms that require different amounts of information shared between the network operator and end-customers are developed to identify a solution of a well-defined social-welfare maximization prob- lem. Notably, the signals broadcast by the network operator assume the connotation of prices/incentives that induce the end- customers to adjust the generated/consumed powers in order to avoid the violation of the voltage constraints. Stability of the proposed schemes is analytically established and numerically corroborated.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Enhancing the US Power Infrastructure

The primary motivation for this set of research activities was to develop a foundation in several aspects of power in order to position Cleveland State University to lead a multiuniversity effort to secure funding for enhanced power system projects and to be able to eventually secure a NASA Space Power Systems Center status through the competitive bidding process. This was accomplished by focusing on these major project areas, (1) the design of the next generation nuclear-electric power generation system, (2) the design of a distributed, fault-tolerant, and modular power system, and (3) the development of the dynamics and control of active magnetic bearings for flywheel energy storage without using conventional sensors.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Coupled Reactor Multiphysics and Mass Scalability Assessment for Crewed Megawatt-Class NEP System Architectures

Nuclear Electric Propulsion (NEP) is an in-space propulsion technology capable of enabling opposition and conjunction class crewed Mars missions. NEP subsystems include the reactor for heat generation, a power conversion system (PCS), power management and distribution, electric propulsion system, and heat rejection system. Specific mass, or α (kg/kWe), is a key performance parameter (KPP) of the propulsion system which is directly scalable with the performance and mass predictions for each individual component. To inform technology maturation planning activities, full system and component level parametric modeling is ongoing to explore the design trade space and illustrate the effect of subsystem design choices on the system KPPs. In this study, scaling of high-assay, low-enriched uranium reactor designs is assessed through coupled reactor physics and thermal hydraulics analyses. Scaling analyses evaluate the impact of system performance parameters (power level, interface temperatures) on mass for direct gas cooled, pumped liquid metal, and passively-cooled heat pipe reactor concepts. Each concept requires specific geometries, fluids, and power conversion interface conditions (temperature, pressure, flow rate) to meet desired performance and mass. The reactor assembly includes the active core (fuel, moderator, cladding, working fluid), axial and radial neutron reflectors, control drums, structural support / pressure vessel, and external radiation shielding. Each of these components are parametrically sized based on performance parameters for a megawatt-class power cycle. Results of this scaling analysis increase NEP propulsion system modeling fidelity and ultimately aim to support concept down-selection along with related technology development planning. The reactor and shield α are a function of several PCS and heat rejection system design choices, and reactor scaling with these parameters must be considered to enable an informed decision on an optimal reactor geometry and working fluid combination.

Nuclear Electric Propulsion↗

More / All Electric Vertical Take-Off and Landing (VTOL) Vehicle Sensitivities to Propulsion and Power Performance

Battery power and energy density are important parameters for the emerging concepts for more / all-electric vehicles. Electric propulsion and power system performance is also important. To better understand how electric propulsion and power systems component performance influences overall vehicle design, a sensitivity assessment was performed noting changes in vehicle gross weight and energy usage. Updated versions of the Revolutionary Vertical lift Technology (RVLT) Project vertical take-off and landing (VTOL) urban air mobility (UAM) reference vehicles and missions were used. NASA electric vehicle studies are discussed which were used to help select the range of electric propulsion and power system performance parameters used in this assessment. Thermal management systems (TMS) considerations are also important; new and innovative power management and distribution systems can reduce electric system weight and losses, reducing thermal management constraints often imposed by electric systems modest maximum use temperatures. Vehicles with higher disk loadings (smaller rotors) require higher power levels per unit weight for VTOL operations, which make them more sensitive to electric system weights and efficiencies. Battery, all-electric vehicles show different sensitivities to component performance than turboelectric or hybrids systems. Battery, all-electric propulsion systems may increase vehicle weight and size, but still results in lower mission energy usage than their hydrocarbon-fueled versions. Significant vehicle weight growth to electric propulsion and power system power-to-weight reductions also occurs at different levels among the various concepts. From these results, one can more readily identify required component performance levels, potential component choices or, research and development paths.

Electric Propulsion Systems (Aircraft)↗

More / All Electric Vertical Take-Off and Landing (VTOL) Vehicle Sensitivities to Propulsion and Power Performance

Battery power and energy density are important parameters for the emerging concepts for more / all-electric vehicles. Electric propulsion and power system performance is also important. To better understand how electric propulsion and power systems component performance influences overall vehicle design, a sensitivity assessment was performed noting changes in vehicle gross weight and energy usage. Updated versions of the Revolutionary Vertical lift Technology (RVLT) Project vertical take-off and landing (VTOL) urban air mobility (UAM) reference vehicles and missions were used. NASA electric vehicle studies are discussed which were used to help select the range of electric propulsion and power system performance parameters used in this assessment. Thermal management systems (TMS) considerations are also important; new and innovative power management and distribution systems can reduce electric system weight and losses, reducing thermal management constraints often imposed by electric systems modest maximum use temperatures. Vehicles with higher disk loadings (smaller rotors) require higher power levels per unit weight for VTOL operations, which make them more sensitive to electric system weights and efficiencies. Battery, all-electric vehicles show different sensitivities to component performance than turboelectric or hybrids systems. Battery, all-electric propulsion systems may increase vehicle weight and size, but still results in lower mission energy usage than their hydrocarbon-fueled versions. Significant vehicle weight growth to electric propulsion and power system power-to-weight reductions also occurs at different levels among the various concepts. From these results, one can more readily identify required component performance levels, potential component choices or, research and development paths.

electric propulsion systems (aircraft) mission ana↗

Paschen Considerations for High Altitude Airships

Recently, there have been several proposals submitted to funding agencies for long-lived high altitude (about 70,000 feet) airships for communications, surveillance, etc. In order for these airships to remain at altitude, high power, high efficiency, lightweight solar arrays must be used, and high efficiency power management and distribution systems must be employed. The needs for high power and high efficiency imply high voltage systems. However, the air pressure at these extreme altitudes is such that electrical power systems will be near the Paschen discharge minimum over a wide range of electrode separations. In this paper, preliminary calculations are made for acceptable high voltage design practices under ambient, hydrogen and helium gas atmospheres.

Ferguson, D. C.↗

Distribution Operations: The Evolution of Distributed Energy Resources [Guest Editorial]

Utilities around the world are experiencing change with the increasing digitalization of their systems and those of their customers. Efforts to decarbonize the electric power system have led to growth in renewable energy resources, particularly distributed energy resources (DERs), such as generation, storage, and flexible load, both in front of and behind the meter. As this change occurs in any given utility service area, new tools, such as advanced distribution management systems (ADMSs), are needed to manage utility operations, planning, and business issues, some of which are discussed here.

distributed energy resources, DER, decarbonize, re↗

Resonant AC power system proof-of-concept test program

Proof-of-concept testing was performed on a 20-kHz, resonant power system breadboard from 1981 through 1985. The testing began with the evaluation of a single, 1.0-kW resonant inverter and progressed to the testing of breadboard systems with higher power levels and more capability. The final breadboard configuration tested was a 25.0-kW breadboard with six inverters providing power to three user-interface modules over a 50-meter, 20-kHz bus. The breadboard demonstrated the ability to synchronize multiple resonant inverters to power a common bus. Single-phase and three-phase 20-kHz power distribution was demonstrated. Simple conversion of 20-kHz to dc and variable-frequency ac was demonstrated as was bidirectional power flow between 20-kHz and dc. Steady state measurements of efficiency, power-factor tolerance, and conducted emissions and conducted susceptibility were made. In addition, transient responses were recorded for such conditions as start up, shut down, load changes. The results showed the 20-kHz resonant system to be a desirable technology for a spacecraft power management and distribution system with multiple users and a utility-type bus.

Wappes, Loran J.↗

Using an Advanced Distribution Management System Test Bed to Evaluate the Impact of Model Quality on Volt/VAR Optimization: Preprint

In this paper, we present a test bed for evaluating existing and future advanced distribution management system (ADMS) applications in a realistic laboratory setting, including other utility management systems and field equipment. We present an example of using it to evaluate the impact of the ADMS network model quality on a Volt/VAR optimization (VVO) application. The test bed integrates a commercial ADMS with a real-time simulation model of a utility distribution feeder. Representative power and controller hardware are integrated through hardware-in-the-loop (HIL) techniques. The performance of the ADMS VVO application is also evaluated for different levels of measurement density. Initial results indicate that a higher model quality achieves the highest possible energy savings while avoiding voltage violations, whereas a lower model quality results in increased energy savings but at the expense of more voltage violations.

ADMS↗

Robust metal-ceramic coaxial cable sensors for distributed temperature monitoring in fossil energy power systems

The project aims to develop a new type of low cost, robust metal-ceramic coaxial cable (MCCC) Fabry-Pérot interferometer (FPI) sensor and demonstrate the capability of cascading a series of FPI sensing points in a single MCCC for real-time distributed monitoring of temperature up to 1000°C. The technical accomplishments of this project include: (i) development of metal and ceramic materials for fabricating the MCCC suitable for use in high temperature (up to 1000oC) fossil fuel, (ii) design, construction and test of single point MCCC-FPI sensors for high temperature measurement at deviation within ±2.7%, (iv) demonstration of the MCCC-FPI sensors for real-time distributed temperature measurement with desired sensitivity, spatial resolution, stability, and response speed that are important to practical applications, and (v) development of a novel MCCC-FPI sensor platform for measuring high frequency dielectric constants for solids and liquids as function of temperature. Single point MCCC-FPI sensors are fabricated based on the FPI parameters, including the relationship between reflector width and reflectance as well as the inter-reflector distance for a FPI, estimated by model calculations. MCCC-FPI sensors have been made using insulators of packed ceramic powders, ceramic tubes, and air or inert gases; outer conductors of various metal tubes; inner conductors of wires of the same metal materials as the tubes used; and reflectors of dense ceramic discs, casted ceramic discs and air gaps. The insulator, conductor and reflector materials are investigated for their thermal, chemical, and structural stabilities under temperatures up to 1000°C in simulated coal-derived syngas. Based on the experimental findings, alumina tube and discs, and stainless steel tube and wire are selected for reflector, insulator and outer and inner conductors, respectively. Air or inert gases are found to be useful for reflectors (in the form of narrow groves) or insulators (in the form of empty chamber cavity between ceramic discs) in construction of MCCC-FPI sensors. Single point MCCC-FPI sensors have been fabricated using stainless steel as conductors, dense α-alumina tubes as dielectric insulators, and two air gaps in the insulator as reflectors. The MCCC-FPI sensor with air gap reflectors has been demonstrated for measuring temperature between 200 and 500°C using microwave as sensing signal in a frequency range of 2 – 8 GHz. The temperature measurement is achieved by monitoring the frequency shift (Δƒ) of a selected resonant peak of the microwave interferogram reflected from the pair of air gap reflectors. The MCCC-FPI sensor exhibited excellent linear temperature-dependence for Δƒ, good accuracy (deviation ±2.7%), and reasonable response speed (<180 s for stabilization). Thermal drifting of the sensing signal was also rather minimal for the MCCC-FPI sensors after operating for more than one week at around 500oC. MCCC-FPI sensors with each containing 2 or 3 pairs of reflectors (i.e. 2 or 3 FPIs in a single cable) have been fabricated and demonstrated for distributed temperature measurement between 250 and 550°C in a microwave frequency range of 3-6 GHz. The measurement is achieved by monitoring the frequency shift of a selected resonant peak of the reflected microwave interferogram, which is obtained by the join-time-domain signal processing method. The results demonstrate that the FPI sensing points in both the three-point and two-point MCCC sensors can measure distributed high temperature with good reproducibility and consistency in multiple runs of measurement tests. The sensor signal displays excellent linear dependence between temperature and the corresponding frequency shift. The 2-point and 3-point MCCC-FPI sensors also exhibit fast response to environmental temperature changes. A three-point MCCC-FPI sensor has been further examined for temperature measurement up to 1000°C for multiple heating-cooling cycles and the results prove that the sensor is suitable for distributed temperature measurement up to 1000°C. MCCC-FPI sensors with more than 4 FPIs point in a single line are made in two structures: the first uses alumina tube as insulation and air gaps as reflectors; and the second uses air chamber as insulation and complete circular alumina discs (2 mm-thick) as reflectors. MCCC-FPIs in neither of the two structures are able to exceed four FPIs in a cable because the reflections from the FPIs are too strong for the microwave to transmit through >4 FPIs over a long distance. Specially shaped alumina discs made by removing parts of the circular discs are found to decrease the microwave reflectance because of reduced reflection areas. However, the smallest reflectance (in terms of percentage of the incident signal) obtained in this work is as high as 7.5%, which is still too large to construct more than 10 FPIs in a single MCCC. Nevertheless, the feasibility of the proposed multipoint MCCC-FPI has been demonstrated using air insulation and 2 mm-thick low-ε r Teflon discs as reflectors on a 2 m-long cable containing 10 FPIs (with reflectance <5% on each FPI). These results indicate that the contrast of dielectric constant between the insulation and reflector has a more significant impact on the reflectance. Thus, future research efforts should also be directed to developing ceramic materials (dense or porous) with low dielectric constant values which, when used as insulation or reflector, can realize large numbers of FPIs in a single cable over a long distance. To assist the development of high temperature dielectric materials, a novel MCCC-FPI sensor platform is developed and successfully demonstrated for measuring high frequency dielectric constants for fluids, packed dielectric solids, and ceramic tube materials and determining ε r dependencies on temperature and chemical composition, etc..

36 MATERIALS SCIENCE↗

Fiber-Optic Distribution Of Pulsed Power To Multiple Sensors

Optoelectronic systems designed according to time-sharing scheme distribute optical power to multiple integrated-circuit-based sensors in fiber-optic networks. Networks combine flexibility of electronic sensing circuits with advantage of electrical isolation afforded by use of optical fibers instead of electrical conductors to transmit both signals and power. Fiber optics resist corrosion and immune to electromagnetic interference. Sensor networks of this type useful in variety of applications; for example, in monitoring strains in aircraft, buildings, and bridges, and in monitoring and controlling shapes of flexible structures.

Kirkham, Harold↗

Data Management for Digital Twin Implementation: Enhancing Existing SCADA Architecture for INL's CITRC Test Distribution System

The United States power grid will continue to experience stress from aging infrastructure, extreme weather, and increasing loads. In order to strengthen resiliency, researchers need to run tests and simulations that model real-life infrastructure. Idaho National Laboratory (INL) is creating a digital twin of its Critical Infrastructure Test Range Complex (CITRC). CITRC is an at-scale grid testbed which can be configured in utility-realistic distribution scenarios for a variety of tests, such as advanced grid protection and control. A digital twin of this infrastructure would support in-depth tests/simulations without risking physical consequences, before trialing devices under test at-scale. This project focuses on the data acquisition part of constructing a digital twin. It investigates the Supervisory Data Acquisition and Control (SCADA) system of CITRC and explores ways to utilize this system for the twin. Future “ideal” at-scale implementations such as upgraded equipment, modern communication protocols, and automation applications are also explored.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

Energy and Cost Optimized Technology Options to Meet Energy Needs of Food Processors

Full Paper Submission for: Combined cooling, heating and electric power (CCHP) distributed generation (DG) systems can provide electric power and, heating and cooling capability to commercial and industrial facilities directly onsite, while increasing energy efficiency, security of energy supply, grid independence and enhancing the environmental and economic situation for the site. Food processing industries often have simultaneous requirements for heat, steam, chilling and electricity making them well suited for the use of such systems to supply base-load or as peak reducing generators enabling reduction of overall energy use intensity. This paper documents analysis from a project evaluating opportunities enabled by CCHPDG for emission and cost reductions and energy storage systems installed onsite at food processing facilities. In addition, this distributed generation coupled with energy storage demonstrates a non-wires solution to delay or eliminate the need for upgrades to electric distribution systems. It was found that a dairy processing plant in the Pacific Northwest currently purchasing 15,000 MWh/yr of electricity and 190,000 MMBtu/yr of gas could be provided with a 1.1 MW CCHP system reducing the amount of electric power purchased to 450 MWh/yr while increasing the gas demand to 255,000 MMBtu/yr. The high percentage of hydro-power in this region resulted in CO2 emissions from CCHP to be higher than that attributed to the electric utility/regional energy mix. The value of this work is in documenting a real-world example demonstrating the value of CCHP to facility owners and financial decision makers to encourage them to more seriously consider CCHP systems when building or upgrading facilities.

Makhmalbaf, Atefe↗

2022 Component Innovation Awardee: Pecos Wind Power

Distributed wind energy systems supply electricity for nearby homes and businesses, often in remote and rural regions. Systems capable of capturing energy in areas with low wind speeds make it possible to deploy these clean energy systems in many geographic locations. Pecos Wind Power's 85-kilowatt (kW) horizontal-axis PW85 wind turbine shows potential to reduce the levelized cost of energy by approximately 55% when compared to typical small wind systems while achieving utility-scale capacity factors of more than 40% in areas with lower wind speeds. To maximize cost competitiveness, the Pecos Wind Power turbine needs a blade optimized for low wind speeds. Through its 2022 Competitiveness Improvement Project (CIP) award, Pecos Wind Power and partner Wetzel Wind Energy Services will model, optimize, fabricate, and validate a 14.5-meter wind turbine blade made specifically for these applications. Three prior CIP awards supported Pecos Wind Power's initial development of the PW85 turbine.

CIP↗

Space station automation of common module power management and distribution

The purpose is to automate a breadboard level Power Management and Distribution (PMAD) system which possesses many functional characteristics of a specified Space Station power system. The automation system was built upon 20 kHz ac source with redundancy of the power buses. There are two power distribution control units which furnish power to six load centers which in turn enable load circuits based upon a system generated schedule. The progress in building this specified autonomous system is described. Automation of Space Station Module PMAD was accomplished by segmenting the complete task in the following four independent tasks: (1) develop a detailed approach for PMAD automation; (2) define the software and hardware elements of automation; (3) develop the automation system for the PMAD breadboard; and (4) select an appropriate host processing environment.

Miller, W.↗

Model-centric distribution automation: Capacity, reliability, and efficiency

A series of analyses along with field validations that evaluate efficiency, reliability, and capacity improvements of model-centric distribution automation are presented. With model-centric distribution automation, the same model is used from design to real-time control calculations. A 14-feeder system with 7 substations is considered. The analyses involve hourly time-varying loads and annual load growth factors. Phase balancing and capacitor redesign modifications are used to better prepare the system for distribution automation, where the designs are performed considering time-varying loads. Coordinated control of load tap changing transformers, line regulators, and switched capacitor banks is considered. In evaluating distribution automation versus traditional system design and operation, quasi-steady-state power flow analysis is used. In evaluating distribution automation performance for substation transformer failures, reconfiguration for restoration analysis is performed. In evaluating distribution automation for storm conditions, Monte Carlo simulations coupled with reconfiguration for restoration calculations are used. As a result, the evaluations demonstrate that model-centric distribution automation has positive effects on system efficiency, capacity, and reliability.

25 ENERGY STORAGE↗