Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Power Performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

Cost and Performance Baseline for Fossil Energy Plants Volume 3: Low Rank Coal and Natural Gas to Electricity

This report presents an independent assessment of the cost and performance of select fossil energy power systems—pulverized coal (PC), circulating fluidized bed (CFB), and natural gas combined cycle (NGCC) plants—using a systematic, transparent technical and economic approach. This is Volume 3 of a five-volume series, which comprise the following reports: Volume 1: Bituminous Coal and Natural Gas to Electricity; Volume 2: Coal to Synthetic Natural Gas and Ammonia (Various Coal Ranks); Volume 3: Low Rank Coal and Natural Gas to Electricity; Volume 4: Bituminous Coal to Liquid Fuels; and Volume 5: Natural Gas Electricity Generating Units for Flexible Operation. The cost and performance of fossil fuel-based generation technologies represented in this report (and the series at large) are important inputs to assessments and determinations of technology combinations to be utilized to meet the projected demands of future power markets. In addition to informing technology comparisons, the reference plant configurations found in this report provide perspective for regulators and policy makers. From a research and development perspective, this report is used to assess goals and metrics and to provide a consistent basis for comparing developing technologies.

20 FOSSIL-FUELED POWER PLANTS↗

Optics Enabled Networks and Architectures for Data Center Cost and Power Efficiency

Bandwidth demand for datacenter networks continues as performance increases and is further fueled by the exploding demand for AI and new HPC workloads. Managing power and costs will require a range of solutions including new networking and workload specialized architectures, composable systems and optical circuit switching. In this study we focus primarily on two topics, examining the benefits of flatter networks (enabled mainly by means of co-packaged-optics-enabled switches) and the utilization improvement potential for composable (disaggregated) systems, while discussing specialized hardware and networks, and optical circuit switching more briefly.

99 GENERAL AND MISCELLANEOUS↗

Small Hydro Power Plants with Integrated BESS for Enhance Resiliency

Battery energy storage systems (BESS) are an important asset for power systems with high integration levels of renewable energy, and they can be controlled to provide various services to the grid. This paper presents the hardware demonstration and characterization of using a utility-scale BESS with grid-following (GFL) and grid-forming (GFM) controls and a run-of-river (ROR) hydropower plant to perform a bottom-up power system black start that enhances power systems' resiliency. ROR hydropower plants are generally not used for power system restoration due to their frequency instability during islanded operation; however, BESS with droop control can provide critical damping to convert a ROR hydropower generator into a black start- capable unit. To demonstrate this, we carry out hardware experiments at the megawatt-scale integrating a synchronous generator driven by a dynamometer, an actual GFL/GFM BESS, a medium-voltage impedance network, and a load bank. The demonstration shows the different roles of BESS with GFL and GFM control in power system restoration. GFL BESS can suffer from high-frequency oscillations, even instability, depending on the droop control gain and loading condition. The results provide further insights for system operators on how GFL- or GFM controlled BESS can enhance grid stability and how hydro-BESS hybrids can operate as a black-start-capable unit. The presented experimental results are also a valuable resource to understand the different stability characteristics of real-world BESS with different control modes.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Demonstration of Power System Black Start with Hydropower Generator and Battery Energy Storage: Preprint

Battery energy storage systems (BESS) are an important asset for power systems with high integration levels of renewable energy, and they can be controlled to provide various services to the grid. This paper presents the hardware demonstration and characterization of using a utility-scale BESS with grid-following (GFL) and grid-forming (GFM) controls and a run-of-river (ROR) hydropower plant to perform a bottom-up power system black start that enhances power systems' resiliency. ROR hydropower plants are generally not used for power system restoration due to their frequency instability during islanded operation; however, BESS with droop control can provide critical damping to convert a ROR hydropower generator into a blackstart- capable unit. To demonstrate this, we carry out hardware experiments at the megawatt-scale integrating a synchronous generator driven by a dynamometer, an actual GFL/GFM BESS, a medium-voltage impedance network, and a load bank. The demonstration shows the different roles of BESS with GFL and GFM control in power system restoration. GFL BESS can suffer from high-frequency oscillations, even instability, depending on the droop control gain and loading condition. The results provide further insights for system operators on how GFL- or GFMcontrolled BESS can enhance grid stability and how hydro-BESS hybrids can operate as a black-start-capable unit. The presented experimental results are also a valuable resource to understand the different stability characteristics of real-world BESS with different control modes.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Advancing Cyber-Attack Detection in Power Systems: A Comparative Study of Machine Learning and Graph Neural Network Approaches

This paper explores the detection and localization of cyber-attacks on power systems, focusing on comparing conventional machine learning (ML) and deep learning methods, and graph neural network (GNN)-based techniques. We assess the detection accuracy of these approaches and their potential to pinpoint the locations of specific buses under attack. Given the demonstrated success of GNNs in other time series anomaly detection applications, we aim to evaluate their performance within the context of power systems cyber-attack. Utilizing the IEEE 68-bus system, we simulated four types of attacks to test the selected approaches. Our results indicate that GNN-based methods outperform conventional machine learning and deep learning models in detection. Additionally, GNNs show promise in accurately localizing attacks for simple scenarios, although they still face challenges in more complex cases.

artificial intelligence↗

Fast External Quantum Efficiency Measurements of Photovoltaic Modules

The external quantum efficiency (EQE) or associated spectral response is widely used to evaluate the performance of photovoltaics, light emitting diodes, photodetectors, photodiodes, semiconductor lasers, laser-induced refrigeration of solids etc. For photovoltaic (PV) devices, The EQE is used to determine the spectral mismatch correction that is used to convert a performance measurement from a non-ideal simulator spectrum to a standard spectrum in PV device calibrations. Moreover, EQE can provide important insight into the physics of a PV device. For instance, the EQE shape can be used to infer mechanisms limiting the performance of the device. However, EQE measurements of full-size PV modules remain a challenge in the PV community due to rare availability of reliable module QE measurement tools worldwide and the size and complexity of module architecture that comprises several cells connected in strings (series or/and parallel). Here, we use a customized nondestructive tool made of high-power light emitting diodes to perform high-throughput EQE measurements on PV modules. Circuit simulations show that the measurement system can safely be used to measure both crystalline silicon and thin film-based PV modules with series connected cells without the risk of damage through reverse bias. In addition, EQE mapping combined with electroluminescence show a strong correlation and provide a way to determine both spatial non-uniformity of the spectral response and defects/degradation effects across the module.

PV module↗

Deployment and performance of a Low-Energy-Threshold Skipper-CCD inside a nuclear reactor

Charge Coupled Devices (CCD) are being used for reactor neutrino experiments and have already demonstrated their potential in constraining new physics models. The prospect of a Skipper-CCD experiment looking for standard and beyond standard model (BSM) physics in a nuclear reactor has been evaluated for different benchmark scenarios. Here, we report the first installation of a 2-g Skipper-CCD inside the containment building of a 2 GW th nuclear power plant and analyze its performance throughout its first 18 months of operation. The sensor was successfully deployed at Atucha II, in Argentina, 12 meters away from the center of the reactor core. We discuss the challenges involved in the commissioning of the detector and present data acquired during reactor ON and reactor OFF periods, with the sensor functioning with a sub-electron readout noise of 0.17 e - . Based on an exposure of 56.8 g day reactor ON and two reactor OFF data sets with a total exposure of 118.1 g day we characterize the system and evaluate the sensitivity to CEvNS. We achieved a background rate of 33 kdru and a low threshold of 45 eV ee . The ongoing efforts to improve sensitivities to CEvNS and BSM interaction are also discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Assessing parallel path cooling tower performance via artificial neural networks

Real-time monitoring of a research nuclear reactor, a system in which all generated power is dissipated to the environment, can be performed via analysis of the heat rejection from the cooling system. Given an inlet water temperature and flow rate, the reactor power can be well-approximated from the outlet water temperature; however, the instrumentation to measure outlet conditions may not be robust or accurate. If we know how a cooling tower performs from historical data, but cannot measure the outlet temperature, a mathematical representation of the system can be inverted to obtain the outlet water temperature that describes the cooling capacity. Unfortunately, model inversion processes are computationally expensive. To address this, an artificial neural network (ANN) is implemented to assess the performance of a multi-cell cooling tower for a nuclear reactor. This approach leverages the Merkel model to obtain an extensive data set describing performance of the cooling tower cells throughout a wide array of potential operating conditions. The Merkel model is expressed as a function of four parameters: the inlet and outlet water temperatures, inlet air wet bulb temperature, and ratio of liquid-to-gas mass flow rates (L/G), which together provide a non-dimensional number indicative of cooling tower performance, called the Merkel integral. Computing a 4-dimensional data structure that describes finite combinations of the Merkel integral, an inverse model is then generated using an ANN to determine the cell outlet water temperature from the other three model parameters along with the computed Merkel integral. Compared to traditional model inversion methods, the ANN reduces the computational time by approximately 4 orders of magnitude, with effectively no sacrifice to solution accuracy, and could be applied for different cooling towers in the event the performance curve is known. Finally, three use cases of the ANN are then reviewed: (1) determining the cell outlet water temperatures when gas flow at rated conditions (GFRC) is known, (2) performing the prior case without knowledge of the GRFC, and (3) assessing performance differences between the individual tower cells.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

AN OVERVIEW OF THE DESIGN AND PERFORMANCE TESTING OF A 275 BAR INTEGRALLY GEARED SUPERCRITICAL CO2 COMPRESSOR FOR POWER GENERATION

An integrally geared compressor-expander (compander) for supercritical CO2 (sCO2) was developed to convert thermal energy to electricity. With operating pressures of 275 bar, this turbomachine represents the state of the art in integrally geared machine architecture, hitting compressor inlet densities of 600 kg/m3 and discharge pressures of 275 bar. The product development was funded by the Department of Energy’s Energy Efficiency and Renewable Energy Office under EE0007114 to advance the state of the art in concentrated solar power applications; however, the technology itself is agnostic to heat source, and is predicted to achieve a thermal-to-electric conversion efficiency of 50% for any indirect heat source capable of providing turbine inlet temperatures of 700°C or greater. While the program encompassed the design and testing for the compressor and turbine elements, this paper will focus on the compressor design and operation. The paper will begin with an introduction to the cycle design and analysis of an indirectly heated integrally geared sCO2 compander, a discussion of the mechanical and aerodynamic design of the compressor that is a two stage radial compressor operating subcritically at 27,512 rpm, and will then proceed to describe the test facility and measured data to characterize the performance and robustness of the machine. The paper will conclude with a discussion on lessons learned throughout the course of commissioning and testing. Practical aspects of testing a compressor operating near the dome including complications relating to obtaining an accurate compressor flow map, efficiency calculations, flow unsteadiness, and associated measurement uncertainties will be discussed.

wilkes, jason↗

Coupled Multiphysics Simulations of Heat Pipe Microreactors Using DireWolf

DireWolf is a multiphysics software driver application designed to simulate heat pipe–cooled nuclear microreactors. Developed under the U.S. Department of Energy, Office of Nuclear Energy Nuclear Energy Advanced Modeling and Simulation (NEAMS) program, the DireWolf software application’s objective is to provide the nuclear community with a design and safety analysis simulation capability. Based upon the NEAMS program Multiphysics Object-Oriented Simulation Environment (MOOSE) computational framework, DireWolf tightly couples nuclear microreactor physics, reactor physics, radiation transport, nuclear fuel performance, heat pipe thermal hydraulics, power generation, and structural mechanics to resolve the interdependent nonlinearities. DireWolf is capable of simulating both steady and transient normal reactor operation and several postulated failure scenarios. We will present the fundamental physics of heat pipe–cooled nuclear microreactors and the MOOSE-based software employed in DireWolf. Both steady and transient results for coupled reactor physics, radiation transport, and nuclear fuel performance are demonstrated.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

A Simple Data-Centric Methodology for Producible Geothermal Well Determinations: Preprint

The Bureau of Land Management (BLM) has traditionally lacked a standardized methodology for determining if a newly drilled geothermal well is "producible," a designation essential for deciding whether a lease should be "held by production." This is a straightforward problem to solve in oil and gas: Demonstrate that a well is economically viable, meaning it produces sufficient oil or gas to exceed direct operating costs and lease-related expenses, such as rentals or minimum royalties. In geothermal, the problem is more complex: Geothermal wells are tightly coupled with the downstream infrastructure - specifically, the power plant, which is often not designed until well after a lease is deemed as "held by production." Although this designation is critical for advancing geothermal power plant development on BLM-managed lands, current geothermal well assessments often rely on ad hoc approaches that can be complex, operator-biased, and heavy in assumptions related to economic viability. To address this, we have developed two complementary methodologies: a minimum power requirement-based approach and a productivity index (PI)-based approach. These methods leverage key flow test data - pressure, temperature, flow rate, and specific enthalpy - to provide reliable and standardized producible well determinations. The minimum power requirement-based approach evaluates wells against specific power output thresholds informed by reservoir experts and the associated temperature requirements. The PI-based approach assesses well productivity using widely accepted reservoir engineering metrics, proposing a threshold of 2.5 kg/s/bar. Both methods are data-driven and grounded in empirical production data from operational geothermal wells, avoiding uncertain economic assumptions while maintaining decision-making accuracy. Wells falling below key performance thresholds (i.e., PI, specific power) are deemed non-producible. These methodologies aim to streamline BLM's decision-making process, reduce nontechnical barriers to geothermal energy adoption, and enable regulatory expansion into states lacking geothermal expertise. Preliminary results indicate clear trends and thresholds in production data that provide actionable insights for evaluating well producibility. Validation using well completion report (WCR) data is ongoing, with promising results demonstrating the potential for these standardized methodologies to impact geothermal development significantly.

15 GEOTHERMAL ENERGY↗

Dynamometer Facts

The National Renewable Energy Laboratory's (NREL's) Flatirons Campus features two dynamometers in the Water Power Systems Laboratory that can perform research validation on marine and hydrokinetic energy devices as well as wind turbine systems from 100 watts to 15 kilowatts (kW) in size. These capabilities can also be combined with programmable loads, blue economy (nrel.gov/water/powering-blue- economy.html) application simulators, and microgrid emulators to test an extensive range of system operation and technology integration. The dynamometers replicate realistic operational conditions to assess power take-of systems and advance the technical readiness of innovations.

dynomometer↗

A Hot‐Swappable, Fault‐Tolerant, Modular Power Converter System for Solar Photovoltaic Plants

The performance metrics of the state-of-the-art commercial solar inverters, such as system cost, operation and maintenance (O&M) cost, service life, reliability, maintainability, and power density are much lower than the target metrics needed to achieve SunShot’s 2030 levelized cost of energy (LCOE) goals. To overcome the shortcomings of the existing solar inverters, this project proposed a novel Hot-Swappable, Fault-Tolerant, Modular Power Converter (HSFT-MPC) concept for solar photovoltaic (PV) plants and proved the concept through the design, fabrication, and laboratory test validation of a single-phase HSFT-MPC prototype. The HSFT-MPC has the following distinct advantages over the state-of-the-art: 1) elimination of harmonic/ electromagnetic interference (EMI) filter in the inverter stage due to the novel topology, 2) lower system cost and higher power density due to the modular design, elimination of harmonic/EMI filter, and lower cooling requirement, 3) higher efficiency due to lower switching frequencies, 4) higher reliability and longer (50 years) service life due to simpler cooling and fault tolerance capability, 5) easier installation, lower O&M cost, and improved maintainability due to the modular design and hot-swappable power electronic building blocks (PEBBs), and 6) improved manufacturability due to the modular design. This project developed a single-phase HSFT-MPC prototype with 25kW nominal output power, 2.4kV, 60Hz nominal AC output, lower than 5% AC output voltage total harmonic distortion, over 5 kW/L inverter power density, and 99.4% inverter peak efficiency, being tolerant to failure of single and multiple PEBBs, and capable of hot swapping of the failed PEBB(s). The HSFT-MPC enables uninterruptable operation of the solar PV plant when failure of single or multiple PEBBs or PV modules occurs. Compared with the existing solar inverters in the market, the HSFT-MPC is expected to reduce the inverter failure-caused downtime and energy losses of solar PV plants by more than 60% and 50%, respectively. Project findings have been presented at major conferences in the field and published in peer-reviewed papers, which added new knowledge to the field of power electronics for solar PV systems. A minicourse on Solar PV Systems was developed for outreach activities. The minicourse will help attract young individuals to the renewable energy profession which has a significant talent shortage. The HSFT-MPC is expected to overcome all of the shortcomings of the state-of-the-art solar inverters in terms of cost, efficiency, service life, reliability, maintainability, and manufacturability targets needed to achieve SunShot’s 2030 LCOE goals. Therefore, the proposed HSFT-MPC concept has the great potential to disrupt the current solar inverter market. This project created a pathway towards industry adoption of the HSFT-MPC to help achieve 50-year service life solar PV systems. Since the solar PV plants using the HSFT-MPC will feature with higher reliability, longer service life, and easier maintenance, they are particularly useful for the rural areas with underserved populations that demand reliable and affordable clean electricity. The outcomes of the project have the strong potential to address national needs in the field of renewable energy to reduce CO 2 emissions from the electricity sector, reduce imports of energy from foreign sources, and improve energy security, efficiency, and sustainability. Since electricity is used in almost all of society’s sectors, the outcomes of the project will benefit various sectors of society and economy.

14 SOLAR ENERGY↗

From TPL assessment to design optimization: Wave energy converter control co-design applied to the RM3

The Reference Model (RM) project developed six marine energy converter concepts using a sequential design methodology, which, while widely adopted in the industry, often overlooks interactions between system components, resulting in suboptimal designs. One such example is the Reference Model 3 (RM3), a two-body point absorber wave energy converter (WEC). An assessment using the Technology Performance Level (TPL) revealed that RM3’s low power-to-cost ratio, partly due to expensive steel construction, limits its techno-economic performance. Here, this study aims to redesign RM3 by reducing its scale and employing control co-design to integrate WEC and Power Take-Off (PTO) dynamics, constraints, and cost considerations within an optimization framework. We demonstrate the limitations of RM3’s current PTO design and explore the benefits of scaling down to enhance techno-economic viability by lowering material costs. Using WecOptTool, we conduct a parameter sweep over gear ratios and spring stiffnesses for various Commercial Off-The-Shelf generators in irregular wave conditions. Our findings emphasize the importance of aligning PTO components with WEC dynamics, showing that control co-design and strategic scaling can improve RM3’s power-to-cost ratio. This study presents a transferable example of applied control co-design for other WECs, supporting early-stage developers in their design decisions.

Off the shelf components↗

ByzSec — A Multi-layered Byzantine Resilient Architecture for Bulk Power System Protective Relays

Reliability, selectivity, and sensitivity are the fundamental attributes of any protection system, acting as the main drivers in the selection of schemes, and equipment. In high-voltage systems, microprocessor-based relays represent the industry’s preferred solution, providing engineers with a vast array of benefits. However, they remain vulnerable to cybersecurity events that may compromise their functionality. To help mitigate against potential cybersecurity risks, this paper presents a fault-tolerant, Byzantine Resilient (BR) architecture that significantly increases the cybersecurity attributes of a protection system while minimizing the amount of performance impacts and integration overheads introduced. The solution relies on an array of independent relays that utilize robust consensus methods (based on Spire [1], [2]) to ensure correct system behavior is achieved even when a relay has been compromised. Furthermore, the solution has been complemented with a custom-built Situational Awareness engine that can be used to detect and identify potential threats. The implemented solution has been developed in consultation with three hardware vendors and has been tested to comply with the performance requirements of a 345kV differential protection scheme (87T). The results indicate that the proposed architecture is a comprehensive solution that: supports the strict correctness and performance requirements of the bulk power grid while providing a cost-effective alternative that offers a seamless, long-term solution.

byzantine security, Fault Tolerant Application Sof↗

Current Source Inverter Based Large Constant Power Speed Ratio SPM Machine Drive for Traction Applications

A high-performance surface permanent magnet (SPM) machine drive with an extended constant power speed ratio is proposed using a current source inverter (CSI) for a traction application. The constant-power operation regions of an SPM machine can be extended in an appealing fashion by taking advantage of the output voltage boost capability of the CSI. The CSI is naturally a boost-type converter, in contrast to the voltage source inverter (VSI) which has buck-type characteristics. To investigate the value of the CSI voltage boost feature, a new traction motor with higher rated voltage and lower rated current has been designed and compared to the motor that would be used with a VSI. The lower CSI current makes it possible to reduce the mass of the inverter and output power cable, benefiting power density and cost reduction. The SPM machine is modeled in the synchronous reference frame including the effect of the ac filter capacitors at the CSI output terminals. The capability of extending the speed range of the proposed motor is verified via closed-form analysis and FEA simulation, and its performance characteristics are compared with those of a VSI-based SPM motor of the same type.

42 ENGINEERING↗

Iodine’s Wild Ride Leading to Photoinstability in Halide Perovskite Solar Cells

Understanding processes that contribute to efficiency losses during long-term operation of perovskite solar cells is crucial for achieving operational stability. Although maximum power point tracking optimizes outdoor performance, it is not uncommon that devices are kept under open-circuit conditions during sunny hours. Under these conditions, charge carriers accumulate at the interfaces rather than flowing through the circuit. In the case of the MAPbI 3 /spiro-OMeTAD interface studied here, hole accumulation leads to formation of I2 and subsequent oxidation of spiro-OMeTAD. By employing in situ absorption measurements, we show that the decrease in power conversion efficiency follows the spiro-OMeTAD oxidation while operating the device under open-circuit conditions. In short-circuit conditions, where photogenerated charge carriers are extracted in the external circuit, the I 2 -induced oxidation of spiro-OMeTAD and the device instability are minimized. The photoinduced expulsion of iodine from MAPbI 3 into spiro-OMeTAD discussed in this work provides new insight into the photoinstability of perovskite solar cells.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Identifying Regimes During Plasma Catalytic Ammonia Synthesis

Herein, we demonstrate that the performance of mesoporous silica SBA-15 and SBA-15-Ag during plasma ammonia synthesis depends on the plasma conditions. At high power, the mesoporous silica SBA-15 without Ag produces the largest amount of ammonia, but the addition of Ag provides a minor benefit at lower powers. Plasma conditions were analyzed through optical emission spectroscopy using N 2 , N 2 + , and NH molecular bands and H α line. Stark broadening of H α line was used to find electron density, and N 2 molecular bands were used to assess N 2 vibrational excitation, important for plasma nitrogen decomposition. At similar input conditions, reactors with SBA-15 have higher electron density and higher N 2 vibrational temperature. Consistent with higher electron density, SBA-15 reactors have stronger N 2 + emission intensity relative to the neutral N 2 . The addition of Ag results in higher N 2 rotational temperature, possibly due to localized heating. From the materials point of view, SBA-15 is a more robust catalyst with good surface area retention after plasma exposure due to the lack of local heating generated when a metal is in the structure. Furthermore, we identify two possible regimes during ammonia synthesis, a metal and a surface-plasma driven. At lower plasma densities, the addition of metal is beneficial, while at higher power and plasma density, the best performance is achieved without the aid of a metal catalyst.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗