Detection of gas leakage

A method of detecting leaks and measuring volumes as well as an apparatus, the Power-free Pump Module (PPM), that is a self-contained leak test and volume measurement apparatus that requires no external sources of electrical power during leak testing or volume measurement, where the invention is a portable, pneumatically-controlled instrument capable of generating a vacuum, calibrating volumes, and performing quantitative leak tests on a closed test system or device, all without the use of alternating current (AC) power. Capabilities include the ability is to provide a modest vacuum (less than 10 Torr), perform a pressure rise leak test, measure the gas's absolute pressure, and perform volume measurements. All operations are performed through a simple rotary control valve which controls pneumatically-operated manifold valves.

47 OTHER INSTRUMENTATION↗

Detection of gas leakage

A method of detecting leaks and measuring volumes as well as a device, the Power-free Pump Module (PPM), provides a self-contained leak test and volume measurement apparatus that requires no external sources of electrical power during leak testing or volume measurement. The PPM is a portable, pneumatically-controlled instrument capable of generating a vacuum, calibrating volumes, and performing quantitative leak tests on a closed test system or device, all without the use of alternating current (AC) power. Capabilities include the ability is to provide a modest vacuum (less than 10 Torr) using a venturi pump, perform a pressure rise leak test, measure the gas's absolute pressure, and perform volume measurements. All operations are performed through a simple rotary control valve which controls pneumatically-operated manifold valves.

47 OTHER INSTRUMENTATION↗

Designing a High Performance OpenSHMEM Implementation using Universal Common Communication Substrate as a Communication Middleware

OpenSHMEM is an effort to standardize the well-known SHMEM parallel programming library. The project aims to produce an open-source and portable SHMEM API and is led by ORNL and UH. In this paper, we optimize the current OpenSHMEM reference implementa- tion, based on GASNet, to achieve higher performance characteristics. To achieve these desired performance characteristics, we have redesigned an important component of the OpenSHMEM implementation, the network layer, to leverage a low-level communication library designed for imple- menting parallel programming models called UCCS. In particular, UCCS provides an interface and semantics such as native atomic operations and remote memory operations to better support PGAS programming models, including OpenSHMEM. Through the use of microbenchmarks, we evaluate this new OpenSHMEM implementation on various network metrics, including the latency of point-to-point and collective operations. Furthermore, we compare the performance of our OpenSHMEM imple- mentation with the state-of-the-art SGI SHMEM. Our results show that the atomic operations of our OpenSHMEM implementation outperform SGI s SHMEM implementation by 3%. Its RMA operations outperform both SGI s SHMEM and the original OpenSHMEM reference implemen- tation by as much as 18% and 12% for gets, and as much as 83% and 53% for puts.

Welch, Donald A↗

Utilizing many-core accelerators for halo and center finding within a cosmology simulation

Efficiently finding and computing statistics about “halos” (regions of high density) are essential analysis steps for N-body cosmology simulations. However, in state-of-the-art simulation codes, these analysis operators do not currently take advantage of the shared-memory data-parallelism available on multi-core and many-core architectures. The Hybrid / Hardware Accelerated Cosmology Code (HACC) is designed as an MPI+X code, but the analysis operators are parallelized only among MPI ranks, because of the difficulty in porting different X implementations (e.g., OpenMP, CUDA) across all architectures on which it is run. In this paper, we present portable data-parallel algorithms for several variations of halo finding and halo center finding algorithms. These are implemented with the PISTON component of the VTK-m framework, which uses Nvidia's Thrust library to construct data-parallel algorithms that allow a single implementation to be compiled to multiple backends to target a variety of multi-core and many-core architectures. Finally, we compare the performance of our halo and center finding algorithms against the original HACC implementations on the Moonlight, Stampede, and Titan supercomputers. The portability of Thrust allowed the same code to run efficiently on each of these architectures. On Titan, the performance improvements using our code have enabled halo analysis to be performed on a very large data set (81923 particles across 16,384 nodes of Titan) for which analysis using only the existing CPU algorithms was not feasible.

Sewell, Christopher↗

Portable Distortion Free Large Solid Angle Coverage Detector

Neutron single crystal diffractometers require large solid angle coverage for optimum performance. This can be achieved by tiling flat detectors in a cylindrical or spherical geometry, but results in large gaps in detector coverage and parallax distortion. The detector edges exhibit degraded resolution, distortion, and gamma rejection. Since the detector edge regions are a significant fraction of the detector active area, they must be removed from the experimental data set, requiring extra beam time to collect enough analysis data. A spherical detector with a continuous surface would effectively address this issue while eliminating most boundary ‘dead’ areas. Here we report on the development of a novel hemispherical shaped neutron detector using seamlessly tiled readout modules to form the desired shape. The heart of the detector is a specially developed curved neutron scintillator coupled to high resolution silicon photomultiplier (SiPM) Anger cameras via custom made fiber optic tapers (FOTs). The detector has been assembled and initial tests have been conducted at the High Flux Isotope Reactor (HFIR) beamlines at Oak Ridge National Laboratory (ORNL). Here, in this work, we describe details of the scintillator design, fabrication and characterization, evaluation of individual detector modules, the details of the detector design implementation, and evaluation of the assembled detector at ORNL beamlines.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Generic Discretization Library

The GenDiL library is a collection of C++ software abstractions designed to discretize and solve partial differential equations (PDEs) for high-performance computing (HPC) applications. Its primary focus is on modern C++ generic programming, which helps ensure portability across various hardware architectures. The central idea behind the library is to provide building blocks for numerical algorithms-such as discretization methods and iteration patterns-so that domain experts can focus on the math, rather than the low-level details of hardware or implementation. By defining abstractions for data types, iteration over computational grids, and scheduling of operations, the library isolates the high-level PDE algorithms from the platform-specific optimizations needed to achieve efficient performance.

Dudouit, Yohann [Lawrence Livermore National Labor↗

Implementing High Performance Remote Method Invocation in CCA

We report our effort in engineering a high performance remote method invocation (RMI) mechanism for the Common Component Architecture (CCA). This mechanism provides a highly efficient and easy-to-use mechanism for distributed computing in CCA, enabling CCA applications to effectively leverage parallel systems to accelerate computations. This work is built on the previous work of Babel RMI. Babel is a high performance language interoperability tool that is used in CCA for scientific application writers to share, reuse, and compose applications from software components written in different programming languages. Babel provides a transparent and flexible RMI framework for distributed computing. However, the existing Babel RMI implementation is built on top of TCP and does not provide the level of performance required to distribute fine-grained tasks. We observed that the main reason the TCP based RMI does not perform well is because it does not utilize the high performance interconnect hardware on a cluster efficiently. We have implemented a high performance RMI protocol, HPCRMI. HPCRMI achieves low latency by building on top of a low-level portable communication library, Aggregated Remote Message Copy Interface (ARMCI), and minimizing communication for each RMI call. Our design allows a RMI operation to be completed by only two RDMA operations. We also aggressively optimize our system to reduce copying. In this paper, we discuss the design and our experimental evaluation of this protocol. Our experimental results show that our protocol can improve RMI performance by an order of magnitude.

99 GENERAL AND MISCELLANEOUS↗

Luminescent Materials for the Detection of Economically Critical Metals in Harsh Environments

Renewable energy technologies used for electric vehicles and wind turbines are heavily reliant upon metals, such as rare earth elements, cobalt, lithium, and nickel. Indeed, there are 50 minerals that are currently considered “economically critical” by the 2022 United States Geological Survey. With anticipated global adoption of renewable energy technologies, producing sufficient metals to meet this demand presents a significant challenge, particularly due to the current monopolistic market for many of these metals. The production of metals from unconventional sources, such as coal utilization byproducts, is one of many promising strategies to boost domestic supply. However, sensitive, rapid, and inexpensive characterization technologies are needed to minimize production costs associated with metals prospecting and processing. Photoluminescence-based sensing techniques are particularly intriguing due to their potential for low cost and portability, coupled with high sensitivity and selectivity. This presentation focuses on the development of high-performance sensing materials for a range of critical metals, including metal-organic frameworks capable of sensitizing detection of parts-per-billion concentrations of six different rare earth elements, nanoparticles that can detect down to 600 parts-per-billion levels of cobalt, and thin films that sense aluminum down to 120 parts-per-billion. These materials are highly selective, capable of withstanding low pH conditions, and provide a response within minutes. Importantly, each sensing material is integrated with a custom-built, fully portable fiber-optic spectrometer for potential field deployment, providing significant cost savings over commercial instruments, along with potential advantages such as material regeneration for use across multiple sensing cycles and solvent removal for enhanced emission signal. These results highlight the exciting potential of luminescence platforms as cost-effective alternatives for metals characterization.

Crawford, Scott↗

Materials and Modules for Low Cost, High Performance Fuel Cell Humidifiers

The objective of this program was to demonstrate a durable, high performance water transport membrane; and a compact, low-cost, membrane-based module utilizing that membrane for use in an automotive, stationary and/or portable fuel cell water transport exchangers. Over the past 20 years, great technical progress has been made in improving power density and durability of fuel cell stacks. Yet, operating durably at high performance levels under very dry conditions, e.g., < 20% RH at 80°C or above, remains beyond even the best fuel cell membrane electrode assemblies. Thus, today it is essential to humidify the gases supplied to the fuel cell inlets. In this work, we have produced a new, inexpensive, composite membrane capable of very high water vapor transport and low air cross-over. The composite structure consists of a very thin ionomer layer (e.g., < 5 μm) sandwiched between two microporous polymer layers. The thin ionomer layer facilitates the rapid water transport and provides an impermeable layer to prevent gas cross-over. Such an approach reduces cost, but maintains performance. The microporous layer protects the thin ionomer layer from mechanical damage during handling; confers strength to the thin layer allowing it to be more durable during use; and allows it to withstand higher automotive pressures and temperatures. The composite structure will therefore allow lower total cost while still meeting automotive humidifier water transport and durability targets. Because the transport rates of these new materials are so high, existing planar membrane humidifier module designs available at the start of the program were incapable of efficiently utilizing the high rates. Therefore, the assembled team designed, tested and demonstrated an innovative, low-cost humidifier module with customized channel geometries that can take advantage of the high the water transport rates. The objectives of the program have been fully met. The optimized membrane produced in the program has very high transport rates, nearly twice that of the closest competitive option, a homogeneous perfluorosulfonic acid (PFSA) membrane. Furthermore, the composite structure imparts significant durability advantages, allowing the membrane to remain gas impermeable during 20,000 relative humidity (RH) cycles, unlike the closest competitive options that fail very rapidly. It does suffer from a loss of performance with time at temperature because of inherent properties of the PFSA polymer, but this degradation is manageable through relatively simple system design changes. The final membrane of this program has been produced on manufacturing level equipment in a roll to roll form in the scale of hundreds of square meters. The process is readily scalable to automotive level volumes to allow production of a low-cost membrane required for this application. A full scale automotive air-to-air humidifier module has been designed, tested and built. The final module meets the design specifications required for automotive fuel cell use, and exceeds all the DOE 2017 targets for a cathode humidification module as determined in independent testing at Ford Motor Company. It has a small volume, less than 5 liters; a high water transfer rate, significantly greater than 5 g/s at the DOE specified conditions; acceptably low pressure drop; and is projected to maintain these properties over 5000 hours. Additionally, high volume cost projections suggest that the module can be produced for less than $\$$100 per unit in a scale of 500,000 units per year.

08 HYDROGEN↗

Radiometric Testing of Germicidal UV Products, Round 1: UV-C Towers and Whole-Room Luminaires (CALiPER Full Report)

This report analyzes the independently tested performance of 13 germicidal ultraviolet (GUV) products purchased between February and July 2022. The products were of three different types: • Seven portable, consumer-oriented GUV towers designed to be placed on the floor or a desk of an unoccupied room to disinfect air and surfaces. Five of these products used LED sources and two products used low-pressure mercury (LPM) sources. • One non-portable GUV whole-room luminaire designed to be installed on a ceiling to disinfect air when a room is occupied. This product used an LED source. • Five non-portable GUV troffer or high-bay style whole-room luminaires designed to be installed in or suspended from a ceiling to disinfect air and surfaces when a room is unoccupied. All five used LPM sources. Radiometric and electrical performance was evaluated for all 13 products. Photobiological safety was also assessed for two of the products because their documentation included testable claims. The test results were compared across products and to manufacturer or vendor claims. The testing identified many issues related to the accuracy of reported GUV product performance. Claims were often untestable, contradictory, ambiguous, or used incorrect units and/or terminology. And when claims were testable, they often did not match test results. For example, three products that claimed to emit UV-C emitted only UV-A. These product claim issues were more numerous with consumer-oriented tower products, but problems with accurate performance claims were found across all products. The UV-C radiant efficiency of the products varied widely, even among similar products using the same source technologies. For example, the UV-C radiant efficiency of LPM products varied by greater than a factor of three for the same product type, indicating a large potential energy savings opportunity for products that are better designed for efficiency. LED products had orders-of-magnitude lower UV-C radiant efficiency than LPM products. Several testing challenges and limitations were identified. Most significant among these is the capability to accurately test and report the performance of larger GUV products. Integrating spheres require a specialized and costly coating to test UV, and the testing laboratory for this round of products had only a 20-inch diameter hemisphere with this capability. Only 2 of the 10 UV-C emitting products could be tested in this sphere. Goniometer testing had a different size limitation in that mirrors typically used to increase goniometer test distance to the far field are not reflective of UV and therefore could not be used to increase test distance. As a result, 7 of 13 products could not be tested far field. The implication is that electronic files of UV-C intensity data typically imported into design software for designing GUV applications may not be reliable for predicting irradiance at arbitrary far-field distances. It is currently unclear if these are industry-wide testing laboratory limitations, and what solutions may exist to address them. Specifiers and buyers of GUV products will need accurate performance claims and data to safely and effectively deploy GUV technology to reduce the transmission of diseases in buildings. This CALiPER GUV Round 1 report demonstrates the significant education and training that is needed for manufacturers and vendors to accurately test and report the performance of their GUV products. Further standards and guidelines are needed to improve test methods, address testing limitations, and improve reporting of product performance. Additionally, the wide range in UV-C radiant efficiency of GUV products means there is a large energy-savings opportunity for more energy efficient GUV products.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ERDE: The Earth-Field Resonance Detection and Evaluation Devices

Researchers at Los Alamos have developed the Earth-field Resonance Detection and Evaluation devices, or ERDE (German for “Earth”) which brings portable chemical analysis and identification into the field. ERDE uses the Earth’s magnetic field to perform nuclear magnetic resonance measurements without the need for sample preparation, costly cryogens, or calibration procedures, meaning it is extremely user-friendly. In fact, using the Earth’s magnetic field allows detection and identification of chemical species through non-magnetic pipes without sampling, reducing the likelihood of costly biofouling. This innovative new device brings together these outstanding benefits to improve processes in the detection of noxious chemicals in water supplies as well as the identification of toxic materials anywhere. There are two fully-functional ERDE prototypes and efforts are underway to miniaturize the system further for improved portability, increased sensitivity, and expanded capabilities. The Laboratory is seeking qualified licensing or CRADA partners to finalize development of this system.

47 OTHER INSTRUMENTATION↗

Design and Performance Characterization of RADICAL-Pilot on Leadership-Class Platforms

Many extreme scale scientific applications have workloads comprised of a large number of individual highperformance tasks. The Pilot abstraction decouples workload specification, resource management, and task execution via job placeholders and late-binding. As such, suitable implementations of the Pilot abstraction can support the collective execution of large number of tasks on supercomputers. We introduce RADICAL-Pilot (RP) as a portable, modular and extensible Pilot enabled runtime system. We describe RP's design, architecture and implementation. We characterize its performance and show its ability to scalably execute workloads comprised of tens of thousands heterogeneous tasks on DOE and NSF leadership-class HPC platforms. Specifically, we investigate RP's weak/strong scaling with CPU/GPU, single/multi core, (non)MPI tasks and python functions when using most of ORNL Summit and TACC Frontera. RADICAL-Pilot can be used stand-alone, as well as the runtime for third-party workflow systems.

97 MATHEMATICS AND COMPUTING↗

Effective Source-to-Source Outlining to Support Whole Program Empirical Optimization

Although automated empirical performance optimization and tuning is well-studied for kernels and domain-specific libraries, a current research grand challenge is how to extend these methodologies and tools to significantly larger sequential and parallel applications. In this context, we present the ROSE source-to-source outliner, which addresses the problem of extracting tunable kernels out of whole programs, thereby helping to convert the challenging whole-program tuning problem into a set of more manageable kernel tuning tasks. Our outliner aims to handle large scale C/C++, Fortran and OpenMP applications. A set of program analysis and transformation techniques are utilized to enhance the portability, scalability, and interoperability of source-to-source outlining. More importantly, the generated kernels preserve performance characteristics of tuning targets and can be easily handled by other tools. Preliminary evaluations have shown that the ROSE outliner serves as a key component within an end-to-end empirical optimization system and enables a wide range of sequential and parallel optimization opportunities.

99 GENERAL AND MISCELLANEOUS↗

A Segregated Approach for Modeling the Electrochemistry in the 3-D Microstructure of Li-Ion Batteries and Its Acceleration Using Block Preconditioners

Abstract Battery performance is strongly correlated with electrode microstructure. Electrode materials for lithium-ion batteries have complex microstructure geometries that require millions of degrees of freedom to solve the electrochemical system at the microstructure scale. A fast-iterative solver with an appropriate preconditioner is then required to simulate large representative volume in a reasonable time. In this work, a finite element electrochemical model is developed to resolve the concentration and potential within the electrode active materials and the electrolyte domains at the microstructure scale, with an emphasis on numerical stability and scaling performances. The block Gauss-Seidel (BGS) numerical method is implemented because the system of equations within the electrodes is coupled only through the nonlinear Butler–Volmer equation, which governs the electrochemical reaction at the interface between the domains. The best solution strategy found in this work consists of splitting the system into two blocks—one for the concentration and one for the potential field—and then performing block generalized minimal residual preconditioned with algebraic multigrid, using the FEniCS and the Portable, Extensible Toolkit for Scientific Computation libraries. Significant improvements in terms of time to solution (six times faster) and memory usage (halving) are achieved compared with the MUltifrontal Massively Parallel sparse direct Solver. Additionally, BGS experiences decent strong parallel scaling within the electrode domains. Last, the system of equations is modified to specifically address numerical instability induced by electrolyte depletion, which is particularly valuable for simulating fast-charge scenarios relevant for automotive application.

25 ENERGY STORAGE↗

Development of a new radiometer for the thermodynamic measurement of high temperature fixed points

The National Physical Laboratory (NPL) has developed a new radiometer to measure the thermodynamic melting point temperatures of high temperature fixed points with ultra-low uncertainties. In comparison with the NPL's Absolute Radiation Thermometer (ART), the 'THermodynamic Optical Radiometer' (THOR) is more portable and compact, with a much lower size-of-source effect and improved performance in other parameters such as temperature sensitivity. It has been designed for calibration as a whole instrument via the radiance method, removing the need to calibrate the individual subcomponents, as required by ART, and thereby reducing uncertainties. In addition, the calibration approach has been improved through a new integrating sphere that has been designed to have greater uniformity.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Methods for Specifying Scientific Data Standards and Modeling Relationships with Applications to Neuroscience [Plus Supplementary Data]

Neuroscience continues to experience a tremendous growth in data; in terms of the volume and variety of data, the velocity at which data is acquired, and in turn the veracity of data. These challenges are a serious impediment to sharing of data, analyses, and tools within and across labs. Here, we introduce BRAINformat, a novel data standardization framework for the design and management of scientific data formats. The BRAINformat library defines application-independent design concepts and modules that together create a general framework for standardization of scientific data. We describe the formal specification of scientific data standards, which facilitates sharing and verification of data and formats. We introduce the concept of Managed Objects, enabling semantic components of data formats to be specified as self-contained units, supporting modular and reusable design of data format components and file storage. We also introduce the novel concept of Relationship Attributes for modeling and use of semantic relationships between data objects. Based on these concepts we demonstrate the application of our framework to design and implement a standard format for electrophysiology data and show how data standardization and relationship-modeling facilitate data analysis and sharing. The format uses HDF5, enabling portable, scalable, and self-describing data storage and integration with modern high-performance computing for data-driven discovery. The BRAINformat library is open source, easy-to-use, and provides detailed user and developer documentation and is freely available at: https://bitbucket.org/oruebel/brainformat.

60 APPLIED LIFE SCIENCES↗

USE OF PORTABLE GAMMA SPECTROMETERS FOR IDENTIFYING PERSONS EXPOSED IN A NUCLEAR CRITICALITY

At Y-12 triage-style assessments are used to identify persons potentially exposed to high doses from criticality accident radiations using portable instruments by assessing the presence of activated sodium atoms in a person's blood. Historically, simple hand-held Geiger-Mueller (G-M) probes were used for these purposes although it was recognized that, since these instruments contain no information on incident photon energy, it was impossible to differentiate between photons emitted by contamination on the potentially exposed worker from activation of sodium in the person s blood. This works examines the use of a portable gamma spectrometer for assessing blood sodium activation. Irradiations of a representative phantom were performed using two neutron source configurations (unmoderated and polyethylene-moderated 252Cf) and measurements were made using the spectrometer and a G-M detector following irradiation. Detection limits in terms of personnel neutron dose are given for two neutron fields representing metaland solution criticality spectra. Both Geiger-Mueller and spectrometer results indicate a low minimum detectable neutron dose indicating that both instrument are useful as an emergency response instrument. The spectrometer has the added benefit of discriminating between surface contamination and blood sodium activation.