Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Photon counting”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

A loophole-free Bell's inequality experiment

The proof of Nature's nonlocality through Bell-type experiments is a topic of longstanding interest. Nevertheless, no experiments performed thus far have avoided the so-called 'detection loophole,' arising from low detector efficiencies and angular-correlation difficulties. In fact, most, if not all, of the systems employed to date can never close this loophole, even with perfect detectors. In addition, another loophole involving the non-rapid, non-random switching of various parameter settings exists in all past experiments. We discuss a proposal for a potentially loophole-free Bell's inequality experiment. The source of the EPR-correlated pairs consists of two simultaneously-pumped type-2 phase-matched nonlinear crystals and a polarizing beam splitter. The feasibility of such a scheme with current detector technology seems high, and will be discussed. We also present a single-crystal version, motivated by other work presented at this conference. In a separate experiment, we have measured the absolute detection efficiency and time response of four single-photon detectors. The highest observed efficiencies were 70.7 plus or minus 1.9 percent (at 633 nm, with a device from Rockwell International) and 76.4 plus or minus 2.3 percent (at 702 nm, with an EG&G counting module). Possible efficiencies as high as 90 percent were implied. The EG&G devices displayed sub-nanosecond time resolution.

Kwiat, Paul G.↗

High-Performance X-ray Detection in a New Analytical Electron Microscope

X-ray detection by energy-dispersive spectrometry in the analytical electron microscope (AEM) is often limited by low collected X-ray intensity (P), modest peak-to-background (P/B) ratios, and limitations on total counting time (tau) due to specimen drift and contamination. A new AFM has been designed with maximization of P. P/B, and tau as the primary considerations. Maximization of P has been accomplished by employing a field-emission electron gun, X-ray detectors with high collection angles, high-speed beam blanking to allow only one photon into the detector at a time, and simultaneous collection from two detectors. P/B has been maximized by reducing extraneous background signals generated at the specimen holder, the polepieces and the detector collimator. The maximum practical tau has been increased by reducing specimen contamination and employing electronic drift correction. Performance improvments have been measured using the NIST standard Cr thin film. The 0-3 steradian solid angle of X-ray collection is the highest value available. The beam blanking scheme for X-ray detection provides 3-4 times greater throughput of X-rays at high count rates into a recorded spectrum than normal systems employing pulse-pileup rejection circuits. Simultaneous X-ray collection from two detectors allows the highest X-ray intensity yet recorded to be collected from the NIST Cr thin film. The measured P/B of 6300 is the highest level recorded for an AEM. In addition to collected X-ray intensity (cps/nA) and P/B measured on the standard Cr film, the product of these can be used as a figure-of-merit to evaluate instruments. Estimated minimum mass fraction (MMF) for Cr measured on the standard NIST Cr thin film is also proposed as a figure-of-merit for comparing X-ray detection in AEMs. Determinations here of the MMF of Cr detectable show at least a threefold improvement over previous instruments.

Lyman, C. E.↗

Hematological and TGF-beta variations after whole-body proton irradiation

The acute effects of proton whole-body irradiation on five bone-marrow-derived cell types and transforming growth factor-beta 1 (TGF-beta 1) were examined and compared to the effects of photons (60Co). C57BL/6 mice were exposed to 3 Gy (0.4 Gy/min) protons at spread-out Bragg peak (SOBP), protons at entry (E), or 60Co and euthanized on days 0.5-17 thereafter. 60Co-irradiated animals had decreased erythrocytes, hemoglobin and hematocrit at 12 hours post-exposure; depression was not noted in proton (SOBP or E)-irradiated groups until day 4. Significantly decreased leukocyte counts were observed at this same time in all irradiated groups, with lymphocyte loss being greater than that of monocytes, and the depression was generally maintained. In contrast, the levels of neutrophils and thrombocytes fluctuated, especially during the first week; significant differences were noted among irradiated groups in neutrophil levels. Plasma TGF-beta 1 was elevated on day 7 in the 60Co, but not proton, irradiated mice. Collectively, the data show that dramatic and persistent changes occurred in all irradiated groups. However, few differences in assay results were seen between animals exposed to protons (SOBP or E) or photons, as well as between the groups irradiated with either of the two regions of the proton Bragg curve.

Non-NASA Center↗

Spatial distribution of Compton-produced X-ray flux from rich and regular clusters of galaxies

The spatial distribution of radio and X-ray fluxes from rich and regular clusters of galaxies is discussed. A diffusion model is investigated in which high-energy electrons are ejected from a point source at the center of the cluster. While diffusing out, the electrons lose energy by Compton scattering with the universal blackbody photons, thus producing the X-ray emission. Traversing intracluster magnetic fields, the electrons emit synchrotron radio emission. For the Coma cluster of galaxies good agreement is found between the observed and predicted X-ray counting-rate distribution for the Compton model. From the observed radio data a value of about 3 by 10 to the -8th power gauss is deduced for the average magnetic-field strength in the central region of Coma.

Rephaeli, Y.↗

A direct observation of solar neutrons following the 0118 UT flare on 1980 June 21

The Gamma Ray Spectrometer on the Solar Maximum Mission satellite has observed energetic solar neutrons (greater than 50 MeV) at the earth following a solar flare that occurred on the west limb on June 21, 1980 at 01:18:20 UT. Impulsive photon emission from 10 keV to greater than 65 MeV lasting over a period of about 66 s was followed by a transient flux of 50-600 MeV neutrons incident over a 17 minute period. The peak counting rate corresponds to an average flux at the earth of (3.8 + or - 0.6) x 10 to the -2nd neutrons/sq cm s at 130 MeV. These observations indicate the emission of 3 x 10 to the 28th neutrons/sr with energies greater than 50 MeV, requiring the rapid acceleration (much less than 60 s) of protons to GeV energies during the impulsive phase of the flare.

Chupp, E. L.↗

A balloon-borne Ge/Li/ spectrometer for gamma-ray astronomy

On June 10, 1974, a new high-resolution gamma ray spectrometer operating in the energy range of 0.05 to 10 MeV was successfully balloon-flight tested. This system uses four 40 cu cm Ge(Li) crystals in a single cryostat as prime sensors. A 6.35 cm thick CsI (Na) shield provides background rejection and collimation, defining a solid angle of 0.095 sr. Cooling is provided by a liquid-nitrogen dewar. The system was highly stable with spectral resolution of better than 2.5 keV at 1 MeV for the flight duration. The background total count rate was about 20 counts/sec. Numerous lines were observed, most of which originated from secondary neutron interactions in the spectrometer. The sensitivity of the system to line emissions originating in cosmic point sources is 0.0001 to 0.001 photons per sq cm s over the energy range.

Jacobson, A. S.↗

Extracting the Galactic Center excess’ source-count distribution with neural nets

The two leading hypotheses for the Galactic Center excess (GCE) in the Fermi data are an unresolved population of faint millisecond pulsars (MSPs) and dark-matter (DM) annihilation. The dichotomy between these explanations is typically reflected by modeling them as two separate emission components. However, point sources (PSs) such as MSPs become statistically degenerate with smooth Poisson emission in the ultrafaint limit (formally where each source is expected to contribute much less than one photon on average), leading to an ambiguity that can render questions such as whether the emission is PS-like or Poissonian in nature ill defined. We present a conceptually new approach that describes the PS and Poisson emission in a unified manner and only afterwards derives constraints on the Poissonian component from the so obtained results. For the implementation of this approach, we leverage deep learning techniques, centered around a neural network-based method for histogram regression that expresses uncertainties in terms of quantiles. We demonstrate that our method is robust against a number of systematics that have plagued previous approaches, in particular DM/PS misattribution. In the Fermi data, we find a faint GCE described by a median source-count distribution (SCD) peaked at a flux of ~ 4 x 10 -11 counts cm -2 s -1 (corresponding to ~ 3-4 expected counts per PS), which would require N ~ $\mathscr{O}$(10 4 ) sources to explain the entire excess (median value N = 29,300 across the sky). Although faint, this SCD allows us to derive the constraint η ρ ≤ 66% for the Poissonian fraction of the GCE flux η ρ at 95% confidence, suggesting that a substantial amount of the GCE flux is due to PSs.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Prompt Photofission Neutron Detection in Depleted Uranium

The detection of prompt photofission neutrons during active interrogation is a strong indication of the presence of special nuclear materials. However, the high-energy photons used for interrogation create a very challenging radiation environment for the detection of prompt fission signatures. These challenges include detector saturation and pulse pile-up. Additionally, there is an elevated neutron background that further challenges the detection of prompt fission neutrons. This background is produced because of (γ, Xn) photonuclear reactions in the surrounding high-Z materials. Here, we demonstrate the detection of prompt photofission neutrons in these challenging environments. Depleted uranium (DU) and lead targets are interrogated with bremsstrahlung photons produced by a 9-MV electron linear accelerator. Fast neutrons are detected with trans-stilbene organic detectors, and scintillation pulses are analyzed using a previously developed and demonstrated artificial neural network system. We observe a 5 times higher photoneutron count rate when the lead target is replaced with the DU target. Additionally, we observe a difference in the photoneutron light-output distributions of lead and DU. Here, this difference in the measured distributions is due to the difference in the photoneutron-energy spectra; DU photoneutrons are emitted with (γ, n) and watt-energy spectra, whereas lead photoneutrons are emitted with only the (γ, n) spectrum.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Statistical performance of the intensified charged coupled device

The first analysis of the statistical performance of the intensified charge coupled device (CCD) is presented. The Poisson statistics of the arriving photons, the exponential pulse height distribution of the microchannel plate in the image intensifier, and the effects of discrete digitization of the charge in reading the CCD are included. A range of intensifier gains from the high levels that permit pulse counting to the low levels that can be used with the accumulation of charge on the CCD is considered. As a tool for this analysis, an analytical model of the performance of the detector system that is generally useful for predicting many aspects of system performance under a wide range of conditions is developed. The statistical penalty for operating the intensified CCD in the charge accumulation mode is not severe, and in some applications it may be desirable to accept this penalty to gain the advantages of increased dynamic range through charge accumulation. This investigation has revealed no pathological aspects of the operation of the detector system.

Sandel, B. R.↗

A rare gas optics-free absolute photon flux and energy analyzer to provide absolute photoionization rates of inflowing interstellar neutrals

A prototype spectrometer has been developed for space applications requiring long term absolute EUV photon flux measurements. The energy spectrum of the incoming photons is transformed directly into an electron energy spectrum by taking advantage of the photoelectric effect in one of several rare gases at low pressures. Using an electron energy spectrometer, followed by an electron multiplier detector, pulses due to individual electrons are counted. The overall efficiency of this process can be made essentially independent of gain drifts in the signal path, and the secular degradation of optical components which is often a problem in other techniques is avoided. A very important feature of this approach is its freedom from the problem of overlapping spectral orders that plagues grating EUV spectrometers. An instrument with these features has not been flown before, but is essential to further advances in our understanding of solar EUV flux dynamics, and the coupled dynamics of terrestrial and planetary atmospheres. The detailed characteristics of this optics-free spectrometer are presented in the publications section.

Judge, Darrell L.↗

A rare gas optics-free absolute photon flux and energy analyzer for solar and planetary observations

We have developed a prototype spectrometer for space applications requiring long term absolute EUV photon flux measurements. In this recently developed spectrometer, the energy spectrum of the incoming photons is transformed directly into an electron energy spectrum by taking advantage of the photoelectric effect in one of several rare gases at low pressures. Using an electron energy spectrometer, followed by an electron multiplier detector, pulses due to individual electrons are counted. The overall efficiency of this process can be made essentially independent of gain drifts in the signal path, and the secular degradation of optical components which is often a problem in other techniques is avoided. A very important feature of this approach is its freedom from the problem of overlapping spectral orders that plagues grating EUV spectrometers. An instrument with these features has not been flown before, but is essential to further advances in our understanding of solar EUV flux dynamics, and the coupled dynamics of terrestrial and planetary atmospheres. The detailed characteristics of this optics-free spectrometer are presented in the publications section.

Judge, Darrell L.↗

Dose and dose rate effects of whole-body gamma-irradiation: II. Hematological variables and cytokines

The goal of part II of this study was to evaluate the effects of gamma-radiation on circulating blood cells, functional characteristics of splenocytes, and cytokine expression after whole-body irradiation at varying total doses and at low- and high-dose-rates (LDR, HDR). Young adult C57BL/6 mice (n = 75) were irradiated with either 1 cGy/min or 80 cGy/min photons from a 60Co source to cumulative doses of 0.5, 1.5, and 3.0 Gy. The animals were euthanized at 4 days post-exposure for in vitro assays. Significant dose- (but not dose-rate-) dependent decreases were observed in erythrocyte and blood leukocyte counts, hemoglobin, hematocrit, lipopolysaccharide (LPS)-induced 3H-thymidine incorporation, and interleukin-2 (IL-2) secretion by activated spleen cells when compared to sham-irradiated controls (p < 0.05). Basal proliferation of leukocytes in the blood and spleen increased significantly with increasing dose (p < 0.05). Significant dose rate effects were observed only in thrombocyte counts. Plasma levels of transforming growth factor-beta 1 (TGF-beta 1) and splenocyte secretion of tumor necrosis factor-alpha (TNF-alpha) were not affected by either the dose or dose rate of radiation. The data demonstrate that the responses of blood and spleen were largely dependent upon the total dose of radiation employed and that an 80-fold difference in the dose rate was not a significant factor in the great majority of measurements.

NASA Discipline Radiation Health↗

High-resolution pulse-counting array detectors for imaging and spectroscopy at ultraviolet wavelengths

The performance characteristics of multianode microchannel array (MAMA) detector systems which have formats as large as 256 x 1024 pixels and which have application to imaging and spectroscopy at UV wavelengths are evaluated. Sealed and open-structure MAMA detector tubes with opaque CsI photocathodes can determine the arrival time of the detected photon to an accuracy of 100 ns or better. Very large format MAMA detectors with CsI and Cs2Te photocathodes and active areas of 52 x 52 mm (2048 x 2048 pixels) will be used as the UV solar blind detectors for the NASA STIS.

Timothy, J. Gethyn↗

Analysis strategy for ultrafast X-ray photon correlation spectroscopy

We explain an analysis strategy for ultrafast X-ray photon correlation spectroscopy, a technique enabled by X-ray free electron lasers to probe nano- and atomic-scale dynamics in complex systems on nanosecond timescales or faster. Central to the technique is the methodology for extracting contrast in coherent X-ray diffraction patterns, known as speckle patterns. Guided by simulations, we analyze common challenges and examine errors encountered in contrast extraction. A method for accurately determining contrast amid shot noise across a wide range of count rates is presented.

36 MATERIALS SCIENCE↗

Ultrasoft x ray bursts: A clue to the origin of gamma ray bursts?

A search was conducted for short timescale (less than or approx. 10 s) faint X ray bursts in the complete 201,000,000 photon Einstein Observatory imaging proportional counter (IPC) data base. Some 73,000,000 events were extracted which were distributed among 11,230 observing intervals with an average observing time of approx. 1400 seconds. To exclude all sources, only those spatial pixels were searched with a count rate less than 6 x 10(exp -4) counts/sec sq arcmin. The mean count rate was much less. All files with less than 400 secs of observing time were excluded. The data was then binned into overlapping cells 4'.3 by 4'.3 by 10 secs in volume, and all the space-time cells were searched to locate cells with more than 5 counts in a 10 sec interval; i.e., a minimum flux enhancement of 50 over the mean rate for that point in space. Some 52 such events were found. An annulus was inspected around the event to see if it coincided with a general rise in the counter's event rate. Ten events did coincide with counter phenomena; these were associated with sunrise, sunset, or the approach of the South Atlantic Anomaly and were excluded. The remaining 42 events were then examined in an attempt to associate them with instrumental or environmental artifacts. The event occurrence times are uniformly distributed over the course of the mission and show no correlation with local solar time; their positions are randomly distributed in geographic, Galactic, and celestial coordinates. Their summed radial distribution is consistent with the point response function of the IPC for a soft source, indicating that the events are focused by the Observatory's mirror system. The integrated spectrum is, indeed, quite soft and is very similar to that of the cataclysmic variable star U Gem in outburst. Most of the events have risetimes of less than or approx. 1 sec and decay times ranging from 1 to 20 sec. Their positions are not associated with any class of catalogued objects. Several possible origins are discussed for the events; if they are associated with gamma ray bursters, they provide interesting constraints on the space density and repetition rate of the underlying source population.

Helfand, D. J.↗

Detection of a long-duration solar gamma-ray flare on June 11, 1991 with EGRET on COMPTON-GRO

The detection of high energy photon emission from a long-duration solar gamma-ray flare on June 11, 1991 is reported. Gamma rays were detected up to energies above 1 GeV. The solar origin of this emission is assured by the time profile of the gamma-ray count rate and by time-resolved sky maps, which show a clear maximum at the position of the sun. There are indications for a spectral evolution with time, such that the emission below 100 MeV fades away earlier than the 100-300 MeV radiation, roughly on the time scale of the fast component. The spectrum of the flare can be well fitted with a composite of a proton generated pi exp 0 spectrum and an electron bremsstrahlung component. The latter can be identified with the fast decaying component of the lightcurve.

Kanbach, G.↗

The Ever Changing X-ray Sky: X-ray Transients Observed With BATSE

X-ray transients are typically sources in our own galaxy. They are called "transient" because they usually spend more time in quiescence than in outburst. These transients consist of a compact object and a "normal" star in a binary system. The compact objects in some of these systems are known to be neutron stars because they exhibit X-ray bursts or periodic pulsations, Other systems are believed to contain black holes based upon their outburst behavior and in some cases, optical measurements of their masses. The Burst and Transient Source Experiment (BATSE), one of 4 instruments on the Compton Gamma Ray Observatory, was an all-sky instrument sensitive to photons from about 20 keV to 2 MeV, designed primarily to detect gamma-ray bursts. Transient and persistent hard X-ray point sources were extracted from the data using the Earth occultation method to measure source intensities. In this method, the change in count rate in a BATSE detector was measured just before and just after a source location was occulted by the Earth. For long period pulsars (>1 second) Fourier transforms and epoch-folded searches were used to measure pulse frequency and pulsed flux. Using these methods, 3 black hole candidates and 6 X-ray pulsars were discovered with BATSE during its 9 years in orbit. BATSE provided unprecedented temporal coverage in the 20 keV - 2 MeV band, allowing detection of numerous new outbursts of X-ray transients. In this talk, I will describe the BATSE instrument, discuss methods we use to detect hard X-ray sources, and describe observations of X-ray transients.

Wilson-Hodge, Colleen A.↗

Erratum: Monoenergetic photon-induced fission cross-section ratio measurements for U 235 , U 238 , and Pu 239 from 9.0 to 17.0 MeV

In this erratum we report a correction to the previously published photofission cross-section ratio data. The actinide fission-chamber foils utilized in this work were extensively characterized during a new campaign using α- and γ-ray spectroscopy, and 2π alpha counting. These three techniques agreed, resulting in an improved accuracy of the fission-chamber foil masses used in the original experiment. The foil masses measured by α spectroscopy are detailed in Table I. All foils were counted on the same α spectrometer, using an identical geometry, which reduces the systematic uncertainty in the calculated mass ratios since the α spectrometer efficiency cancels out in the ratio. This results in a relative uncertainty on the mass ratio of 1.0% for 235 U/ 238 U, 0.62% for 239 Pu/ 235 U, and 1.1% for 239 Pu/ 238 U. The published cross-section ratio data are re-calculated to reflect the updated target masses and uncertainties. The new mass values cause a 2.40% decrease for the σ( 235 U(γ, f)/ 238 U(γ, f)) ratio, a 5.10% decrease for the σ( 235 U(γ, f)/ 239 Pu(γ, f)) ratio, and a 2.77% decrease for the σ( 238 U(γ, f)/ 239 Pu(γ, f)) ratio. The updated cross-section ratios are presented in Tables II, III, and IV, which are corrected versions of Tables III, IV, and V in Ref. [1]

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗