Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Phase detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

Very high resolution radiometer

A primary sensor used in environmental and earth-resource observation, the Very High Resolution Radiometer (VHRR) was designed for use on the ITOS D series spacecraft. The VHRR provides a 0.47 mile resolution made possible with a mercury-cadmium-telluride detector cooled to approximately 105 K by a passive radiator cooler. The components of this system are described. The optical subsystem of the VHRR consists of a scanning mirror, a Dall-Kirkham telescope, a dichroic beam splitter, relay lenses, spectral filters, and an IR detector. Signal electronics amplify and condition the signals from the infrared and visible light detector. Sync generator electronics provides the necessary time signals. Scan-drive electronics is used for commutation of the motor winding, velocity, and phase control. A table lists the performance parameters of the VHRR.

Aronson, A. I.↗

Manned Mars mission solar physics: Solar energetic particle prediction and warning

There are specific risks to the crew of the manned Mars mission from energetic particles generated by solar activity. Therefore, mission planning must provide for solar monitoring and solar activity forecasts. The main need is to be able to anticipate the energetic particle events associated with some solar flares and, occasionally, with erupting filaments. A second need may be for forecasts of solar interference with radio communication between the manned Mars mission (during any of its three phases) and Earth. These two tasks are compatible with a small solar observatory that would be used during the transit and orbital phases of the mission. Images of the Sun would be made several times per hour and, together with a solar X-ray detector, used to monitor for the occurrence of solar activity. The data would also provide a basis for research studies of the interplanetary medium utilizing observations covering more of the surface of the Sun than just the portion facing Earth.

Suess, S. T.↗

IXPE - The Imaging X-Ray Polarimetry Explorer

The Imaging X-ray Polarimetry Explorer (IXPE) is a Small Explorer Mission that will be proposed in response to NASA's upcoming Announcement of Opportunity. IXPE will transform our understanding of the most energetic and exotic astrophysical objects, especially neutron stars and black holes, by measuring the linear polarization of astronomical objects as a function of energy, time and, where relevant, position. As the first dedicated polarimetry observatory IXPE will add a new dimension to the study of cosmic sources, enlarging the observational phase space and providing answers to fundamental questions. IXPE will feature x-ray optics fabricated at NASA/MSFC and gas pixel focal plane detectors provided by team members in Italy (INAF and INFN). This presentation will give an overview of the proposed IXPE mission, detailing the payload configuration, the expected sensitivity, and a typical observing program.

Ramsey, Brian↗

Snowmass2021 Cosmic Frontier White Paper: Future Gravitational-Wave Detector Facilities

The next generation of gravitational-wave observatories can explore a wide range of fundamental physics phenomena throughout the history of the universe. These phenomena include access to the universe's binary black hole population throughout cosmic time, to the universe's expansion history independent of the cosmic distance ladders, to stochastic gravitational-waves from early-universe phase transitions, to warped space-time in the strong-field and high-velocity limit, to the equation of state of nuclear matter at neutron star and post-merger densities, and to dark matter candidates through their interaction in extreme astrophysical environments or their interaction with the detector itself. We present the gravitational-wave detector concepts than can drive the future of gravitational-wave astrophysics. We summarize the status of the necessary technology, and the research needed to be able to build these observatories in the 2030s.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Sensitivity projections for a dual-phase argon TPC optimized for light dark matter searches through the ionization channel

Dark matter lighter than 10 GeV / c 2 encompasses a promising range of candidates. A conceptual design for a new detector, DarkSide-LowMass, is presented, based on the DarkSide-50 detector and progress toward DarkSide-20k, optimized for a low-threshold electron-counting measurement. Sensitivity to light dark matter is explored for various potential energy thresholds and background rates. These studies show that DarkSide-LowMass can achieve sensitivity to light dark matter down to the solar neutrino fog for GeV-scale masses and significant sensitivity down to 10 MeV / c 2 considering the Migdal effect or interactions with electrons. Requirements for optimizing the detector’s sensitivity are explored, as are potential sensitivity gains from modeling and mitigating spurious electron backgrounds that may dominate the signal at the lowest energies.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Solid state photomultiplier for astronomy, phase 2

Epitaxial layers with varying donor concentration profiles were grown on silicon substrate wafers using chemical vapor deposition (CVD) techniques, and solid state photomultiplier (SSPM) devices were fabricated from the wafers. Representative detectors were tested in a low background photon flux, low temperature environment to determine the device characteristics for comparison to NASA goals for astronomical applications. The SSPM temperatures varied between 6 and 11 K with background fluxes in the range from less than 5 x 10 to the 6th power to 10 to the 13th power photons/square cm per second at wavelengths of 3.2 and 20 cm. Measured parameters included quantum efficiency, dark count rate and bias current. Temperature for optimal performance is 10 K, the highest ever obtained for SSPMs. The devices exhibit a combination of the lowest dark current and highest quantum efficiency yet achieved. Experimental data were reduced, analyzed and used to generate recommendations for future studies. The background and present status of the microscopic theory of SSPM operation were reviewed and summarized. Present emphasis is on modeling of the avalanche process which is the basis for SSPM operation. Approaches to the solution of the Boltzmann transport equation are described and the treatment of electron scattering mechanisms is presented. The microscopic single-electron transport theory is ready to be implemented for large-scale computations.

Besser, P. J.↗

Development of doped-germanium photoconductors for astronomical observations at wavelengths from 30 to 120 micrometers

Technology was developed for production of doped-germanium detectors which have optimized performance in the 30- to 120-micrometer wavelength range and are capable of achieving the objectives of the Infrared Astronomy Satellite space mission. The work of this phase was divided into the following major tasks: (1) growth of Ge:Ga crystals from high-purity starting material with Ga concentrations different from that previously produced, and development of a zone leveling method to produce a uniform Ga doping concentration; (2) growth of uncompensated Ge:Be crystals from high-purity starting material with a range of Be concentrations between 10 to the 14th power and 10 to the 16th power atoms/cubic cm; (3) evaluation of crystals by means of Hall effect and resistance measurements as a function of temperature; (4) fabrication and test of detectors made from both Ge:Be and Ge:Ga crystals to determine the relative performance between different crystals. Correlation of detector test data with material evaluation data and analysis of how to further optimize detector performance.

Bratt, P. R.↗

Latest Results from the ICARUS experiment at the Short-Baseline Neutrino Program

The ICARUS Collaboration is now entering its fifth year of continuing operations of the 760-ton liquid argon T600 detector. The T600 was overhauled at CERN after operations at the LNGS underground laboratory in Italy and moved to its present location at FNAL - as part of the Short-Baseline Neutrino (SBN) program - where it successfully completed its commissioning phase in June 2022. At FNAL ICARUS collects neutrino interactions from both the Booster Neutrino Beam (BNB) and off-axis from the Main Injector Neutrino beam (NuMI). Within the SBN program ICARUS will search for evidence of short-baseline oscillations, potentially explained by eV-scale sterile neutrinos, jointly with the Short-Baseline Near Detector (SBND). In addition, ICARUS is performing stand-along oscillation searches in disappearance mode and measuring neutrino cross sections on argon with both the BNB and NuMI beams. It is also performing searches for additional Beyond the Standard Model signatures. Preliminary results from the ICARUS experiment, using data from the BNB and NuMI neutrino beams, will be presented.

Farnese, Christian [Fermilab]↗

Design and construction of a new detector to measure ultra-low radioactive-isotope contamination of argon

Large liquid argon detectors offer one of the best avenues for the detection of galactic weakly interacting massive particles (WIMPs) via their scattering on atomic nuclei. The liquid argon target allows exquisite discrimination between nuclear and electron recoil signals via pulse-shape discrimination of the scintillation signals. Atmospheric argon (AAr), however, has a naturally occurring radioactive isotope, 39Ar, a ß emitter of cosmogenic origin. For large detectors, the atmospheric 39Ar activity poses pile-up concerns. The use of argon extracted from underground wells, deprived of 39Ar, is key to the physics potential of these experiments. The DarkSide-20k dark matter search experiment will operate a dual-phase time projection chamber with 50 tonnes of radio-pure underground argon (UAr), that was shown to be depleted of 39Ar with respect to AAr by a factor larger than 1400. Assessing the 39Ar content of the UAr during extraction is crucial for the success of DarkSide-20k, as well as for future experiments of the Global Argon Dark Matter Collaboration (GADMC). This will be carried out by the DArT in ArDM experiment, a small chamber made with extremely radio-pure materials that will be placed at the centre of the ArDM detector, in the Canfranc Underground Laboratory (LSC) in Spain. The ArDM LAr volume acts as an active veto for background radioactivity, mostly ?-rays from the ArDM detector materials and the surrounding rock. This article describes the DArT in ArDM project, including the chamber design and construction, and reviews the background required to achieve the expected performance of the detector.

Noble liquid detectors, Dark Matter detectors, Cry↗

A method for correcting aspect solution errors in ROSAT HRI observations of compact sources

X-ray point sources observed with the ROSAT High Resolution Imager (HRI) often appear elongated over scales of approximately 5 sec-10 sec from the image core. This elongation has been attributed to errors in the attitude correction as the satellite is wobbled during the observations, and affects sources with both soft and hard X-ray spectra. In this paper, I report the results of an attempt to rid a high signal-to-noise observation of the soft X-ray point source HZ 43 of its characteristic elongation. I divided the observation into 181 separate images, each containing photons from only a small region on the detector through which the source passed during the satellite's wobble. By measuring the positions of the individual image centroids, I found clear evidence for systematic offsets from a common mean by up to approximately +/- 3 sec in both right ascension and declination as a function of phase in the satellite wobble. Shifting the subimages to a common center and then restacking them into a single image measurably improved the symmetry of the point-spread function. HRI observations are wobbled primarily to smooth out variations in the pixel-to-pixel sensitivity of the detector and also to extend the lifetime of the microchannel plates in the detector since these decay at a given location as a function of the number of photons detected. However, the elongations introduced by the aspect errors inhibit the identification of possible extended X-ray emission associated with sources such as pulsars and active galactic nuclei. In light of these results, I suggest that until the aspect errors are understood, observations of compact sources, where this effect may be important, should not be wobbled.

Morse, Jon A.↗

Advanced methods for preparation and characterization of infrared detector materials

Differential thermal analysis data were obtained on mercury cadmium telluride alloys in order to establish the liquidus temperatures for the various alloy compositions. Preliminary theoretical analyses was performed to establish the ternary phase equilibrium parameters for the metal rich region of the phase diagram. Liquid-solid equilibrium parameters were determined for the pseudobinary alloy system. Phase equilibrium was calculated and Hg(l-x) Cd(x) Te alloys were directionally solidified from pseudobinary melts. Electrical resistivity and Hall coefficient measurements were obtained.

Lehoczky, S. L.↗

Three-Flavor Neutrino Oscillations at NOvA

NOvA, is a two-detector, long-baseline neutrino oscillation experiment located at Fermilab, Batavia, IL, USA. It is designed primarily to constrain neutrino oscillation parameters such as the atmospheric mass squared splitting, $\Delta m^2_{32}$, the mixing angle, $\theta_{23}$, neutrino mass hierachy, and the CP-violating phase, $\delta_{CP}$, using $\nu_\mu \ (\bar{\nu}_\mu)$ disappearance and $\nu_e \ (\bar{\nu}_e)$ appearance data. NOvA receives a high purity 900 KW instense beam of neutrinos and anti-neutrinos from Fermilab's Neutrinos at Main Injector (NuMI) beamline. NOvA used functionally identical finely granulated liquid scintillation detectors, both situated 14.6 mrad off-axis to the beam direction. The NOvA near detector observes un-oscillated $\nu_\mu \ (\bar{\nu}_\mu)$ and beam $\nu_e \ (\bar{\nu}_e)$ events, while the far detector, which is situated 809 km away from the near detector, records un-oscillated $\nu_\mu \ (\bar{\nu}_\mu)$ and oscillated $\nu_e \ (\bar{\nu}_e)$ events. We will discuss the neutrino oscillation analysis strategy at NOvA and the latest three-flavor oscillation results from 10 years of NOvA data in this talk.

43 PARTICLE ACCELERATORS↗

Air quality impacts from the development of unconventional oil and gas well pads: Air toxics and other volatile organic compounds

Unconventional oil and natural gas development (UOGD) has expanded rapidly across the United States in recent decades and raised concerns about associated air quality impacts. While significant effort has been made to quantify methane emissions, relatively few observations have been made of Volatile Organic Compounds (VOCs), especially during drilling and completion of new wells. Extensive air monitoring during development of several large, multi-well pads in Broomfield, Colorado, in the Denver-Julesburg Basin, provides a novel opportunity to examine changes in local air toxics and other VOC concentrations during well drilling and completions and production. These operations offer an especially useful case to study as several management practices were implemented to reduce emissions (e.g., electrified, grid-powered drill rigs and closed loop fluid handling systems to reduce truck traffic and limit fluid handling on the pad). With simultaneous measurements of methane and 50 VOCs from October 2018 to December 2022 at as many as 19 sites near well pads, in adjacent neighborhoods, and at a more distant reference location, we identify impacts from each phase of well development and production. Use of weekly, time-integrated canisters, a Proton Transfer Reaction Mass Spectrometer (PTR-MS), continuous photoionization detectors (PID) to trigger canister collection upon detection of VOC-rich plumes, and an instrumented vehicle, provided a powerful suite of measurements to characterize both transient plumes and longer-term changes in air quality. Prior to the start of well development, VOC gradients were small across Broomfield. Once drilling commenced, concentrations of oil and gas (O&G) related VOCs, including alkanes and aromatics, increased around active well pads. Concentration increases were clearly apparent during certain operations, including drilling, coil tubing/millout operations, and production tubing installation. Emissions of C 8 –C 10 n-alkanes during drilling operations highlighted the importance of VOC emissions from synthetic drilling mud chosen to reduce odor impacts. More than 90 samples were collected of transient plumes. Using composition measurements, meteorological data, and information about well pad activities, these plumes were connected with specific UOGD operations including drilling, flowback, and production equipment maintenance. The chemical signatures of these plumes differed by operation type (e.g., C 8 –C 10 n-alkanes constituted a larger fraction of measured VOCs in drilling-related plumes). Concentrations of individual, oil and gas-related VOCs in these plumes were often several orders of magnitude higher than in background air, with maximum ethane and benzene concentrations of 79,600 and 819 ppbv, respectively. Because these plumes typically impact a monitoring site for just several minutes, they are easily missed by slower-responding instruments. Study measurements highlight future emission mitigation opportunities during UOGD operations, including better control of emissions from shakers that separate drill cuttings from drilling mud, production separator maintenance operations, and periodic emptying of sand cans during flowback operations.

54 ENVIRONMENTAL SCIENCES↗

X-ray nano-holotomography reconstruction with simultaneous probe retrieval

In conventional tomographic reconstruction, the pre-processing step includes flat-field correction, where each sample projection on the detector is divided by a reference image taken without the sample. When using coherent X-rays as a probe, this approach overlooks the phase component of the illumination field (probe), leading to artifacts in phase-retrieved projection images, which are then propagated to the reconstructed 3D sample representation. The problem intensifies in nano-holotomography with focusing optics, which, due to various imperfections creates high-frequency components in the probe function. Here, we present a new iterative reconstruction scheme for holotomography, simultaneously retrieving the complex-valued probe function. Implemented on GPUs, this algorithm results in 3D reconstruction resolving twice thinner layers in a 3D ALD standard sample measured using nano-holotomography.

Nikitin, Viktor↗

Recent progress in laser wire-based H- beam diagnostics at the SNS linac

Laser wire has been used for nonintrusive profile and emittance measurements of operational hydrogen ion (H-) beam at the SNS linac. In this talk, we will describe the following recent developments in the laser wire system. 1) An upgraded light source and laser transport line which enables novel measurement capabilities including longitudinal profile measurement and high-energy proton beam extraction over potentially an entire macropulse. 2) A dual-detector emittance measurement scheme that boosted the dynamic range by an order of magnitude. 3) Design and implementation laser-wire-based nonintrusive longitudinal phase space measurement system.

Liu, Yun↗

Bayesian Exploration and Surrogate Emulation of Nonlinear Beam-Response Geometry in the LBNF Beamline

Next-generation long-baseline neutrino experiments aim to achieve multi-MW proton beam power while reducing accelerator-induced systematic uncertainties. At Fermilab, the LBNF beamline is designed for 1.2 MW operation with PIP-II and is upgradeable to 2.4 MW. DUNE will probe the three-flavor neutrino paradigm and search for CP violation, requiring precise neutrino-flux normalization and improved control of accelerator-related uncertainties. Within the LBNF beamline, the System for On-Axis Neutrino Detection (SAND) will constrain flux uncertainties using precision near-detector measurements, while the Muon Monitor System (MuMS) will provide beamline diagnostics sensitive to the proton beam, target, and horn configuration. However, the pion phase space relevant for DUNE depends simultaneously on many correlated parameters, including beam centroid, beam width, horn current and alignment, target position, optics shifts, and radiation-induced changes. Consequently, MuMS observables exhibit nonlinear and coupled responses that are difficult to characterize using traditional one-parameter scans. To address this challenge, we are developing a Bayesian Exploration framework coupled to physics-informed surrogate emulators trained on Geant4 beamline simulations. Gaussian-process emulators provide both fast predictions and uncertainty estimates, enabling adaptive selection of new simulation points in beam-parameter space. As an initial demonstration, we construct surrogate emulators for MuMS response observables using a verified simulation campaign spanning proton-beam steering conditions. The emulators reproduce the simulated dependence of MuMS centroid and gradient observables while providing predictive uncertainties, and serve as the foundation for future multidimensional exploration including beam width, horn current, and additional beamline parameters. This work establishes a framework for uncertainty-aware beam monitoring, adaptive simulation campaigns, and rapid beam-response inference for future DUNE operations.

Ganguly, Sudeshna [Fermilab] (ORCID:00000003163482↗

Muon to electron conversion search in the presence of Al nuclei at the Fermilab Mu2e experiment: Motivation, Design and Progress

The Mu2e experiment aims to find charged lepton flavor violation(CLFV) by measuring the monochromatic electrons from $\mu^- N\rightarrow e^- N$ conversion with an unprecedented single event sensitivity of $3 \times 10^{-17}$. When completed the experiment will improve the current limit by four orders of magnitude and make a previously unexplored phase space available for the search for beyond the standard model physics. Physics motivation for the experiment is discussed and design choices for the detectors and various sub systems are explained in this document. The construction of the Mu2e experiment is well underway and commissioning will begin in late 2022 with first data taking in late 2025 and 4-5 years of data taking thereafter to reach our goal.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗