Solid amine development program

A regenerable solid amine material to perform the functions of humidity control and CO2 removal for space shuttle type vehicle is reported. Both small scale and large scale testing have shown this material to be competitive, especially for the longer shuttle missions. However, it had been observed that the material off-gasses ammonia under certain conditions. This presents two concerns. The first, that the ammonia would contaminate the cabin atmosphere, and second, that the material is degrading with time. An extensive test program has shown HS-C to produce only trace quantities of atmospheric contaminants, and under normal extremes, to have no practical life limitation.

Lovell, J. S.↗

Improved hybrid rocket fuel

McDonnell Douglas Aerospace, as part of its Independent R&D, has initiated development of a clean burning, high performance hybrid fuel for consideration as an alternative to the solid rocket thrust augmentation currently utilized by American space launch systems including Atlas, Delta, Pegasus, Space Shuttle, and Titan. It could also be used in single stage to orbit or as the only propulsion system in a new launch vehicle. Compared to solid propellants based on aluminum and ammonium perchlorate, this fuel is more environmentally benign in that it totally eliminates hydrogen chloride and aluminum oxide by products, producing only water, hydrogen, nitrogen, carbon oxides, and trace amounts of nitrogen oxides. Compared to other hybrid fuel formulations under development, this fuel is cheaper, denser, and faster burning. The specific impulse of this fuel is comparable to other hybrid fuels and is between that of solids and liquids. The fuel also requires less oxygen than similar hybrid fuels to produce maximum specific impulse, thus reducing oxygen delivery system requirements.

Dean, David L.↗

Research on high Tc superconducting compounds

Mossbauer research using the 21.54 kev resonance radiation of Eu-151 on the high temperature superconductors Bi(2)Ca(0.5)Eu(0.5)Sr(2)CU2O(x), and EuBa(2)CU(3)O(7-x) is performed. For the Bismuth compound the Mossbauer measurements gave a weak signal at room temperature but improved at lower temperatures. Experimental data indicated that europium is located at only one crystallographic site. Isomer shift measurements were .69 + 0.02 mm/s with respect to EuF(3). The linewidth at room temperature was found to be 2.54 mm/s. This value falls within the values observed by other researchers on Eu based 1,2,3 high-Tc compounds. Our results also show the Eu to be trivalent with no trace of divalent europium present. Superconducting europium based 1,2,3 compounds were prepared and measurements completed. Our results show the Eu to be trivalent with no trace of divalent europium present. These compounds had an average isomer shift of .73 mm/s +/- O.02 for all samples made. One of these was irradiated with 3.5 X 10(exp 16) neutrons and a comparison made of the Mossbauer parameters for the irradiated and non-irradiated samples. Experimental results showed no difference between linewidths but a measurable effect was seen for the isomer shift.

Oliver, Frederick W.↗

Crew Exploration Vehicle (CEV) (Orion) Occupant Protection

The purpose of this study was to determine the similarity between the response of the THUMS model and the Hybrid III Anthropometric Test Device (ATD) given existing Wright-Patterson (WP) sled tests. There were four tests selected for this comparison with frontal, spinal, rear, and lateral loading. The THUMS was placed in a sled configuration that replicated the WP configuration and the recorded seat acceleration for each test was applied to model seat. Once the modeling simulations were complete, they were compared to the WP results using two methods. The first was a visual inspection of the sled test videos compared to the THUMS d3plot files. This comparison resulted in an assessment of the overall kinematics of the two results. The other comparison was a comparison of the plotted data recorded for both tests. The metrics selected for comparison were seat acceleration, belt forces, head acceleration and chest acceleration. These metrics were recorded in all WP tests and were outputs of the THUMS model. Once the comparison of the THUMS to the WP tests was complete, the THUMS model output was also examined for possible injuries in these scenarios. These outputs included metrics for injury risk to the head, neck, thorax, lumbar spine and lower extremities. The metrics to evaluate head response were peak head acceleration, HIC15, and HIC36. For the neck, N (sub ij) was calculated. The thorax response was evaluated with peak chest acceleration, the Combined Thoracic Index (CTI), sternal deflection, chest deflection, and chest acceleration- 3 ms clip. The lumbar spine response was evaluated with lumbar spine force. Finally the lower extremity response was evaluated by femur and tibia force. The results of the simulation comparisons indicate the THUMS model had a similar response to the Hybrid III dummy given the same input. The primary difference seen between the two was a more flexible response of the THUMS compared to the Hybrid III. This flexibility was most pronounced in the neck flexion, shoulder deflection and chest deflection. Due to the flexibility of the THUMS, the resulting head and chest accelerations tended to lag the Hybrid III acceleration trace and have a lower peak value. The results of the injury metric comparison identified possible injury trends between simulations. Risk of head injury was highest for the lateral simulations. The risk of chest injury was highest for the rear impact. However, neck injury risk was approximately the same for all simulations. The injury metric value for lumbar spine force was highest for the spinal impact. The leg forces were highest for the rear and lateral impacts. The results of this comparison indicate the THUMS model performs in a similar manner as the Hybrid III ATD. The differences in the responses of model and the ATD are primarily due to the flexibility of the THUMS. This flexibility of the THUMS would be a more human like response. Based on the similarity between the two models, the THUMS should be used in further testing to assess risk of injury to the occupant.

Currie-Gregg, Nancy J.↗

Assessing the Added Value of Miniature X-Ray in the Setting of Portable Ultrasound in Spaceflight

INTRODUCTION: Point-of-care ultrasound (POCUS) has become the standard of care for imaging diagnosis and management in low-Earth Orbit (LEO) spaceflight and it has long been hypothesized that POCUS will also be the standard of care for exploration spaceflight. However, like the trajectory for which ultrasound became more portable and user-friendly, the mass, volume, and power requirements of radiography devices for both diagnostic and therapeutic applications have also been dramatically reduced. This study seeks to determine the clinical utility and added value of miniature x-ray (XR) for the diagnosis and management of each of the 119 conditions within NASA Exploration Medical Capability’s IMPACT Condition List (ICL) given that the medical system is presumed to already be carrying a handheld portable POCUS device. METHODS: For each condition, a team of reviewers performed a rapid systematic literature review seeking sensitivity and specificity data for both handheld portable ultrasound and miniature XR. When there was a paucity of data, subject matter expertise and clinical experience was added to semi-quantitatively score the added value of miniature XR, given an US was already available for both diagnosis and management. Diagnostic utility of a modality for a condition was evaluated in the setting of both the best- and worst-case scenario definitions included and defined by the ICL. Evidence tracing and quality of evidence scores were also recorded. RESULTS/DISCUSSION: Conditions for which it was determined that miniature XR added diagnostic or therapeutic value are provided in this presentation. Previously presented work by our team has demonstrated that XR provides diagnostic and management capabilities that are hypothesized to complement or surpass ultrasound for over one-third of medical conditions that may arise during exploration spaceflight (i.e., diagnosis of injuries to the axial skeleton, teeth, and lungs as well as management of orthopedic reductions, endotracheal tube placement, and drain placement confirmation). In the setting of known inclusion of a handheld portable POCUS device, there remains significant added value of portable miniature XR. Whether or not this added clinical benefit is worth the mass, volume, and power requirements of the radiography system remains yet unknown and is the focus of future work. LEARNING OBJECTIVES: 1) Understand the value of ultrasound and radiography in the diagnosis and management of medical comorbidities that may arise in exploration spaceflight; 2) Understand the medical conditions of highest concern on exploration class missions for which miniature x-ray may provide added value to portable ultrasound.

J G Steller↗

Assessing the Added Value of Miniature X-Ray in the Setting of US in Spaceflight

INTRODUCTION: Point-of-care ultrasound (POCUS) has become the standard of care for imaging diagnosis and management in lowEarth Orbit (LEO) spaceflight and it has long been hypothesized that POCUS will also be the standard of care for exploration spaceflight. However, like the trajectory for which ultrasound became more portable and user-friendly, the mass, volume, and power requirements of radiography devices for both diagnostic and therapeutic applications have also been dramatically reduced. This study seeks to determine the clinical utility and added value of miniature x-ray (XR) for the diagnosis and management of each of the 119 conditions within NASA Exploration Medical Capability’s IMPACT Condition List (ICL) given that the medical system is presumed to already be carrying a handheld portable POCUS device. METHODS: For each condition, a team of reviewers performed a rapid systematic literature review seeking sensitivity and specificity data for both handheld portable ultrasound and miniature XR. When there was a paucity of data, subject matter expertise and clinical experience was added to semi-quantitatively score the added value of miniature XR, given an US was already available for both diagnosis and management. Diagnostic utility of a modality for a condition was evaluated in the setting of both the best- and worst-case scenario definitions included and defined by the ICL. Evidence tracing and quality of evidence scores were also recorded. RESULTS/DISCUSSION: Conditions for which it was determined that miniature XR added diagnostic or therapeutic value are provided in this presentation. Previously presented work by our team has demonstrated that XR provides diagnostic and management capabilities that are hypothesized to complement or surpass ultrasound for over one-third of medical conditions that may arise during exploration spaceflight (i.e., diagnosis of injuries to the axial skeleton, teeth, and lungs as well as management of orthopedic reductions, endotracheal tube placement, and drain placement confirmation). In the setting of known inclusion of a handheld portable POCUS device, there remains significant added value of portable miniature XR. Whether or not this added clinical benefit is worth the mass, volume, and power requirements of the radiography system remains yet unknown and is the focus of future work. LEARNING OBJECTIVES: 1) Understand the value of ultrasound and radiography in the diagnosis and management of medical comorbidities that may arise in exploration spaceflight; 2) Understand the medical conditions of highest concern on exploration class missions for which miniature x-ray may provide added value to portable ultrasound.

Jon Steller↗

Trace Gas Analyzer (TGA) program

The design, fabrication, and test of a breadboard trace gas analyzer (TGA) is documented. The TGA is a gas chromatograph/mass spectrometer system. The gas chromatograph subsystem employs a recirculating hydrogen carrier gas. The recirculation feature minimizes the requirement for transport and storage of large volumes of carrier gas during a mission. The silver-palladium hydrogen separator which permits the removal of the carrier gas and its reuse also decreases vacuum requirements for the mass spectrometer since the mass spectrometer vacuum system need handle only the very low sample pressure, not sample plus carrier. System performance was evaluated with a representative group of compounds.

Source record↗

Soret diffusion: A possible cause of compositional heterogeneity within tektites

Although a terrestrial origin for tektites is well-established on geochemical evidence, the physical processes involved in tektite formation have been largely ignored by geochemists and petrologists. For example, two observations that potentially bear on the physics of their origin are the following: (1) The flange of an australite is often more heterogeneous than its core; and (2) microtektites are compositionally more diverse than tektites. The first observation contradicts the traditional view of flange formation since a second heating to super-liquidus temperatures during atmospheric re-entry should, by chemical diffusion and mixing, have tended to homogenize the melt as it flowed off the leading edge of the core to form the flange. Analyses of an australite flange have been performed by electron microprobe. The results of those analyses emphasize the magnitude of the heterogeneity, as well as the well-defined elemental correlations that may constrain the process responsible for it. The second observation that the bulk compositions of microtektites are more divers than the tektites within the same strewnfield is a well-known characteristic, for which no quantitative explanation has been offered. The current investigation has involved the analysis of 43 Australasian microtektites from the Wharton Basin by electron microprobe, as well as trace-element abundances on fifteen of these microtecktites by INAA.

Delano, J. W.↗

The MSP 2001 Mars Environmental Compatibility Assessment (MECA)

The Mars Environmental Compatibility Assessment (MECA) will evaluate the Martian environment for soil and dust-related hazards to human exploration as part of the Mars Surveyor Program 2001 Lander. Sponsored by the Human Exploration and Development of Space (HEDS) enterprise, MECA's goal is to evaluate potential geochemical and environmental hazards that may confront future Martian explorers, and to guide HEDS scientists in the development of high fidelity Mars soil simulants. The integrated MECA payload contains a wet-chemistry laboratory, a microscopy station, an electrometer to characterize the electrostatics of the soil and its environment, and arrays of material patches to study the abrasive and adhesive properties of soil grains. The instrument will acquire soil samples with a robotic arm equipped with a camera. MECA will examine surface and subsurface soil and dust in order to characterize particle size, shape, hardness, and also physical characteristics that may provide clues to mineralogy. MECA will characterize soil/water mixtures with respect to pH, redox potential, total dissolved ions, and trace toxins. MECA will determine the nature of electrostatic charging associated with excavation of soil, and the influence of ionizing radiation on material properties. It will also observe natural dust accumulation on engineering materials. To accomplish these objectives, MECA is allocated a mass of 10 kg within an enclosure of 35 x 25 x 15 cm. The Wet Chemistry Laboratory (WCL) consists of four identical cells that will accept samples from surface and subsurface regions accessible to the Lander's robotic arm, mix them with water, and perform extensive analysis of the solution. Ion-selective electrodes and related sensors will evaluate total dissolved solids, redox potential, pH, and the concentration of many soluble ions and gases in wet Martian soil. These electrodes can detect potentially dangerous heavy-metal ions, emitted pathogenic gases, and the soil's corrosive potential. Experiments will include cyclic voltammetry and anodic stripping voltammetry. Complementary to the Viking experiments, the chemical laboratory will characterize the water-soil solution rather than emitted gases. Nonetheless, through analysis of dissolved gases it will be able to replicate many of the Viking observations related to oxidants. MECA's microscopy station combines optical and atomic-force microscopy (AFM) in an actively focused, controlled illumination environment to image particles from millimeters to nanometers in size. Careful selection of substrates allows controlled experiments in adhesion, abrasion, hardness, aggregation, magnetic and other properties. Special tools allow primitive manipulation (brushing and scraping) of samples. Soil particle properties including size, shape, color, hardness, adhesive potential (electrostatic and magnetic), will be determined using an array of sample receptacles and collection substrates. The simple, rugged atomic-force microscope will image in the submicron size range and has the capability of performing a particle-by-particle analysis of the dust and soil. On Earth, the earliest forms of life are preserved as microfossils. The atomic-force microscope will have the required resolution to image down to the scale of terrestrial microfossils and beyond. Mounted on the end of the robot arm, MECA's electrometer actually consists of four types of sensors: an electric field meter, several triboelectricity monitors, an ion gauge, and a thermometer. Tempered only by ultraviolet-light-induced ions and a low-voltage breakdown threshold, the dry, cold, dusty martian environment presents an imposing electrostatic hazard to both robots and humans. The field meter will measure the ambient field on nearby objects while the triboelectric sensors, using identical circuitry, will measure the charge accumulated on test substances as they are dragged through the soil by the arm. The ion chamber, open to the environment, will sense both charged dust and free ions in the air. Over and above the potential threat to electronics, the electrostatic environment holds one of the keys to transport of dust and, consequently, Martian meteorology. Viewed with the robot arm camera, the abrasion and adhesion plates are strategically placed to allow direct observation of the interaction between materials and soils on a macroscopic scale. Materials of graded hardness are placed directly under the robot arm scoop to sense wear and soil hardness. A second array, placed on the lander deck, is deployed after the dust plume of landing has settled. It can be manipulated in a primitive fashion by the arm, first having dirt deposited on it from the scoop and subsequently shaken clean. A third array will passively collect dust from the atmosphere. In addition to objectives related to human exploration, the MECA data set will be rich in information relevant to basic geology, paleoclimate, and exobiology issues. To understand both contemporaneous and ancient processes on Mars, the mineralogy, petrology, and reactivity of Martian surface materials should be constrained. The MECA experiment will shed light on these quantities through its combination of chemistry and microscopy. MECA will be capable of measuring the composition of ancient surface water environments, observing microscopic evidence of geological (and biological?) processes, inferring soil and dust transport, comminution and weathering mechanisms, and characterizing soil horizons that might be encountered during excavation.

Hecht, M. H.↗

Automatic Locking of Laser Frequency to an Absorption Peak

An electronic system adjusts the frequency of a tunable laser, eventually locking the frequency to a peak in the optical absorption spectrum of a gas (or of a Fabry-Perot cavity that has an absorption peak like that of a gas). This system was developed to enable precise locking of the frequency of a laser used in differential absorption LIDAR measurements of trace atmospheric gases. This system also has great commercial potential as a prototype of means for precise control of frequencies of lasers in future dense wavelength-division-multiplexing optical communications systems. The operation of this system is completely automatic: Unlike in the operation of some prior laser-frequency-locking systems, there is ordinarily no need for a human operator to adjust the frequency manually to an initial value close enough to the peak to enable automatic locking to take over. Instead, this system also automatically performs the initial adjustment. The system (see Figure 1) is based on a concept of (1) initially modulating the laser frequency to sweep it through a spectral range that includes the desired absorption peak, (2) determining the derivative of the absorption peak with respect to the laser frequency for use as an error signal, (3) identifying the desired frequency [at the very top (which is also the middle) of the peak] as the frequency where the derivative goes to zero, and (4) thereafter keeping the frequency within a locking range and adjusting the frequency as needed to keep the derivative (the error signal) as close as possible to zero. More specifically, the system utilizes the fact that in addition to a zero crossing at the top of the absorption peak, the error signal also closely approximates a straight line in the vicinity of the zero crossing (see Figure 2). This vicinity is the locking range because the linearity of the error signal in this range makes it useful as a source of feedback for a proportional + integral + derivative control scheme that constantly adjusts the frequency in an effort to drive the error to zero. When the laser frequency deviates from the midpeak value but remains within the locking range, the magnitude and sign of the error signal indicate the amount of detuning and the control circuitry adjusts the frequency by what it estimates to be the negative of this amount in an effort to bring the error to zero.

Koch, Grady J.↗

Thermal and Kinetic Properties of Motions in a Prominence Activation and Nearby Loop

We perform a quantitative analysis of the thermal properties of a prominence activation and motions in a nearby loop. In order to make measurements of the quickly moving features seen in prominences in the UV we use the SOHO/SUMER spectrograph to take a time series of exposures from a single pointing position, providing a measurement of spectral line properties as a function of time and position along the slit. The lines observed cover a broad range of temperatures from 80,000 - 1.6 million K. These measurements are combined with TRACE movies in transition region and coronal temperature bands to obtain more complete information concerning prominence structure and motions. The resulting observations allow us to analyze the thermal and kinetic energy of the moving sources as functions of time. The loop and prominence are most apparent in lines formed at temperatures below 250,000 K. We find that in most cases the temperature distribution of plasma in a moving feature changes relatively little over time periods of about 20 minutes.

Kucera, Therese↗

Comparison of observed and modeled longwave radiances

Calculated LW radiances based on NMC profiles of temperature and humidities for the month of July 1985 are obtained using standard procedures for performing radiative transfer calculations, and are within 3 percent (against a standard deviation of 4 percent) for global daytime land comparsions and within 1 percent (against a standard deviation of 1.5 percent) for a case study located over North America. The calculated values over the global data set show a slight trend with the surface temperature, and since there is no obvious trend with the column amount of water vapor, it is argued that the trend with temperature is evidence that absorption by other components (i.e., CO2O3 and other trace gases not included in these calculations) in the model could be improved.

Stone, Kenneth↗

Comparison of Environmentally Friendly Space Compatible Grease to its Predecessor in a Space Mechanism Bearing Test Rig

Perfluoroakylpolyether (PFPE) greases are used extensively in critical flight hardware in a space environment. In the past, these greases have been processed using chlorofluorocarbon (CFC) based solvents. In response to the recent ban of CFC's, new formulations of environmentally friendly PFPE greases that are not processed with CFC based solvents were developed. The purpose of this study was to compare the performance of a new environmentally friendly formulation PFPE grease to a previously proven space compatible formulation PFPE grease. A one year test using 20 small electrical motors (two bearings per motor) was conducted in a high vacuum environment(2.0 x 10(exp 4)) Torr at a temperature of 90 C. Twenty bearings were lubricated with a new environmentally friendly formulation, and twenty bearings were lubricated with an old formulation. The mass of each lubricated bearing was measured both pre and post test. Along with mass loss measurements a profilometer trace was taken to measure post test wear of the bearings. In addition the bearings were visually examined and analyzed using an optical microscope.

T R Jett↗

Trace gas emissions to the atmosphere by biomass burning in the west African savannas

Savanna fires and atmospheric carbon dioxide (CO2) detection and estimating burned area using Advanced Very High Resolution Radiometer_(AVHRR) reflectance data are investigated in this two part research project. The first part involves carbon dioxide flux estimates and a three-dimensional transport model to quantify the effect of north African savanna fires on atmospheric CO2 concentration, including CO2 spatial and temporal variability patterns and their significance to global emissions. The second article describes two methods used to determine burned area from AVHRR data. The article discusses the relationship between the percentage of burned area and AVHRR channel 2 reflectance (the linear method) and Normalized Difference Vegetation Index (NDVI) (the nonlinear method). A comparative performance analysis of each method is described.

Frouin, Robert J.↗

Coupling Processes Between Atmospheric Chemistry and Climate

This is the first semi-annual report for NAS5-97039 summarizing work performed for January 1997 through June 1997. Work in this project is related to NAS1-20666, also funded by NASA ACMAP. The work funded in this project also benefits from work at AER associated with the AER three-dimensional isentropic transport model funded by NASA AEAP and the AER two-dimensional climate-chemistry model (co-funded by Department of Energy). The overall objective of this project is to improve the understanding of coupling processes between atmospheric chemistry and climate. Model predictions of the future distributions of trace gases in the atmosphere constitute an important component of the input necessary for quantitative assessments of global change. We will concentrate on the changes in ozone and stratospheric sulfate aerosol, with emphasis on how ozone in the lower stratosphere would respond to natural or anthropogenic changes. The key modeling tools for this work are the AER two-dimensional chemistry-transport model, the AER two-dimensional stratospheric sulfate model, and the AER three-wave interactive model with full chemistry.

Ko, M. K. W.↗

Adaptive optics and optical structures; Proceedings of the Meeting, European Congress on Optics, 3rd, The Hague, Netherlands, Mar. 12-14, 1990

The present conference on adaptive optics (AO) and optical structures addresses AO systems and controls, AO components, nonlinear optics applications to AO, astronomical applications of AO, large telescopes and optical alignment, as well as the wavefront control experiment for the use of AO in beam propagation. Specific references are made to applications of electromagnetic theory in optics, theoretical studies of system performance and design parameters, Hartmann-Shack wavefront sensing, the use of ray-based techniques in cophasing segmented mirrors, the use of a phase-conjugating mirror for real-time phase visualization, and the absolute instability of oppositely directed waves with respect to a high-reflectivity phase-conjugate mirror. Also addressed are automatic control systems, precision segmented reflectors, AO system creation, the VLT's 8.2-m primary mirrors, an optical 12-m telescope, alignment optimization via the Talbot effect, and a combination of interferometry and ray-tracing analysis.

Tyson, Robert K.↗

Optimization of Instrument Requirements for NASAs GEO-CAPE Coastal Mission Concept Based On Sensor Capability And Cost Studies

NASA's GEOstationary Coastal and Air Pollution Events (GEOCAPE) mission concept recommended by the U.S. National Research Council (2007) focuses on measurements of atmospheric trace gases and aerosols and aquatic coastal ecology and biogeochemistry from geostationary orbit (35,786 km altitude). GEO-CAPE is currently in pre-formulation (pre- Phase) A with no established launch date. NASA continues to support science and engineering studies to reduce mission risk. Instrument design lab (IDL) studies were commissioned in 2014 to design and cost two implementations for geostationary ocean color instruments (1) Wide-Angle Spectrometer (WAS) and (2) Filter Radiometer (FR) and (3) a cost scaling study to compare the costs for implementing different science performance requirements.

Geo-CAPE↗

Digital Lunar Exploration Sites (DLES)

It has been almost 50 years since humans last set foot on the Moon. With NASA’s Artemis program, the United States and its international and commercial partners are embarking on a new endeavor to explore the lunar surface. Before we return, we will have simulated every aspect of these future missions. Many of these models and simulations (M&S) will rely on well-known and commonly-used technologies, some of which trace their origins back to the Apollo program. However, M&S has advanced significantly, as have the underlying computational capabilities. As a result, we are able to model many more aspects of the Artemis vehicles and support systems with significantly improved detail and confidence. Accurately and efficiently modeling the lunar environment will be critical to simulating the Artemis elements and mission activities. This includes characterizing and modeling lunar topography, smaller craters, exposed surface rocks, lunar regolith, surface lighting, and ambient thermal environment. These are all necessary for understanding fundamental behaviors and performance of vehicles and support systems in the lunar environment and are often determining factors in the selection of exploration sites and defining mission profiles. The Astromaterials Research and Exploration Sciences (ARES) team in the Exploration Integration and Science Directorate at NASA’s Johnson Space Center (JSC) and the NASA Exploration Systems Simulations (NExSyS) team in the Simulation and Graphics Branch at JSC are developing and maintaining the Digital Lunar Exploration Sites (DLES) data, documentation, and software packages. This data is being fed directly into a diverse collection of graphics and simulation environments, where it is used to construct the closest known truth for numerous potential Lunar South Pole landing sites. DLES is available to projects across NASA and particularly the Artemis program to support coordinated digital representations of the lunar environment. This paper describes the fundamental need for DLES, the science data sets that are going into DLES, some of the processes used to integrate this data into DLES products, the basic products that constitute DLES, and some examples of DLES in use.