Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Passivation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

Passive solar array orientation devices for terrestrial application.

A passive solar array orientation device, called a thermal heliotrope, is described, and several terrestrial applications are illustrated. The thermal heliotrope consists of a bimetallic helical coil that serves as the motor element, producing torque and angular displacement. A control mechanism in the form of one or more shades completes the basic device. In comparison with electromechanical tracking systems, the thermal heliotrope is electrically passive, has relatively few parts, and is low cost. After describing the principle of operation and several models built for space applications, the design considerations for several terrestrial thermal heliotrope units are presented. It is suggested that the use of the thermal heliotrope for solar array orientation could significantly reduce array cost, thereby increasing the competitive economic posture of solar arrays for terrestrial applications. The thermal heliotrope modified for terrestrial use is readily adaptable to orient solar energy concentrators, such as furnaces and stills.

Fairbanks, J. W.↗

Passive suppression of pogo on the space shuttle

A qualitative assessment of the tendency for pogo instability of the shuttle vehicle in the absence of suppression devices, and the effectiveness of two passive suppressors (the compliant accumulator and the resistive accumulator) in counteracting any tendency toward instability is provided. In addition, the relative effectiveness of three suppressor locations (the low pressure pump (LWOP) inlet and discharge and the high pressure pump (HPOP) inlet) is also evaluated. The primary conclusion of the study is that effective pogo suppression, with passive devices, can be accomplished at the HPOP inlet location but not at the LPOP locations. Other conclusions are drawn regarding the relative effectiveness of the two accumulator types and with respect to tentative accumulator design requirements. Finally, a number of recommendations are made regarding future studies.

Lock, M. H.↗

The 4-8 GHz Microwave Active and Passive Spectrometer (MAPS). Volume 1: Radar section

The performance characteristics of the radar section of the prototype 4-8 GHz Microwave Active and Passive Spectrometer system are reported. Active and passive spectral responses were measured of natural, cultivated, and human-made surfaces over the 4-18 GHz region of frequencies for look angles between zero and 70 degrees and for all possible linear polarization combinations. Soil and plant samples were collected to measure their dielectric properties and moisture content. The FORTRAN program for area calculation is provided.

Ulaby, F. T.↗

The surface geometry of inherited joint and fracture trace patterns resulting from active and passive deformation

Hypothetical models are considered for detecting subsurface structure from the fracture or joint pattern, which may be influenced by the structure and propagated to the surface. Various patterns of an initially orthogonal fracture grid are modeled according to active and passive deformation mechanisms. In the active periclinal structure with a vertical axis, fracture frequency increased both over the dome and basin, and remained constant with decreasing depth to the structure. For passive periclinal features such as a reef or sand body, fracture frequency is determined by the arc of curvature and showed a reduction over the reefmound and increased over the basin.

Podwysocki, M. H.↗

Passivation of pigment particles for thermal control coatings

Various redox couple surface additives are studied which increase the photostability of coprecipitated zinc orthotitanate pigment. The electron spin resonance technique was used to examine the characteristic photodamage centers. Results indicate that cerium surface redox additive completely passivates the pigment at the surface concentrations studied. Less passivation occurs with the iridium chloride and the iron cyanide redox couples.

Sancier, K. M.↗

On the determination of atmospheric path length by passive microwave radiometer

Microwave radiometer techniques were evaluated for use in atmospheric path length correction of Pacific Plate Motion Experiment interferometer measurements. It is shown that passive microwave radiometry allows precise measurement of the brightness temperature of the sky. It is also noted that the technological requirements of radiometers are very different from the requirements of radio astronomy. The technology was used in the construction of radiometers which are sufficient for use in the path length correction problem. A simulation study shows that, when combined with surface meteorology data, passive microwave radiometer data would allow a determination of the path length correction to better than 2 cm at the zenith. By a careful choice of frequencies, a dual frequency system would allow a measurement of the path length correction to better than 4 cm at zenith angles as great as 60 deg. Because of the wide range of weather conditions to be expected for the PPME sites (which include Alaska, Hawaii and Massachusetts), it will probably be necessary to use a separate correction algorithm for each site.

Webster, W. J., Jr.↗

Simultaneous active and passive microwave response of the earth - The Skylab radscat experiment

The Skylab microwave radiometer-scatterometer experiment S-193 was designed to collect simultaneous information on the radiometric emission and the backscatter from the earth from orbital altitude for the first time. A primary driving force was ascertaining the response from the oceans of both active and passive systems to variations in wind, and the ability of the passive system to aid in calibrating the active system. Numerous overland applications were also explored. Preliminary results of backscatter and emission from sea and atmosphere are shown for hurricane Ava and for two flights across the Gulf of Mexico. The results tend to confirm the most recent theoretical prediction of an approximately square-law relation between scattering coefficient for horizontal polarization and windspeed, with a somewhat smaller dependence for vertical polarization. Overland measurements show that scatterometer signals at 30 deg increase and radiometer signals decrease for terrain that has recently experienced rainfall.

Moore, R. K.↗

The scientific justification of a radar scatterometer and a passive microwave system on Seasat-A

The purpose of these two systems is to determine the winds over the ocean. The passive system may also provide data on precipitation over the ocean and sea surface temperature through clouds. They complement each other. The radar scatterometer will sense those sea surface properties that define the winds over the ocean through clouds so thick and so wet that the passive microwave system will have detected only the cloud properties. Both wind speed and direction can be found from the combined data to be obtained.

Pierson, W. J.↗

Frequency allocations for passive use of the radio spectrum to make scientific studies

The paper examines the legal implications of frequency allocations for passive use of the radio spectrum, which refer to receive-only radio services. Such receive-only services refer to the reception of radio signals generated by nonhuman agencies as in radio astronomy or in the search for extraterrestrial intelligence. Juridical interpretations of the public interest and of necessity are applied to these passive services.

Stull, M. A.↗

Active and passive multispectral scanner for earth resources applications: An advanced applications flight experiment

The development of an experimental airborne multispectral scanner to provide both active (laser illuminated) and passive (solar illuminated) data from a commonly registered surface scene is discussed. The system was constructed according to specifications derived in an initial programs design study. The system was installed in an aircraft and test flown to produce illustrative active and passive multi-spectral imagery. However, data was not collected nor analyzed for any specific application.

Hasell, P. G., Jr.↗

Adaptation to visual and proprioceptive rearrangement - Origin of the differential effectiveness of active and passive movements

Experiments were conducted to measure and compare the accuracy with which subjects pointed to visual targets before and after an exposure period in which they received systematic proprioceptive misinformation about the locations of visual targets. The crucial factor determining whether adaptation will be elicited is shown to be the presence of a discordance in the positional information being conveyed over two different sensory modalities. Another experiment was carried out to study the effectiveness of active and passive movements in eliciting adaptation when the subjects were exposed to a systematic discordance between the visual and proprioceptive locations of external targets without being permitted sight of their hands. Superiority of active over passive movements in producing adaptation to visual rearrangement is due to the greater accuracy of position sense information about voluntarily moved limbs, partly derived from the contribution of muscle afferent signals.

Lackner, J. R.↗

Passive microwave radiometric observations of the atmosphere

Passive microwave sensing techniques can be used to obtain the temperature of the atmosphere, and to infer liquid water, water vapor and other molecular species over ocean or above the troposphere. The use of satellite-borne passive microwave radiometers is discussed along with the future use of the instrument on Nimbus-G and on the space shuttle.

Cassel, A. L.↗

Photonitride passivating coating for IC's

Increased reliability and simplified fabrication result from postassembly preencapsulation passivation process. Photonitride reaction chamber receives silane, ammonia, and mercury from mixing manifold to form passivating coating on IC's. Photonitride layer is barrier to moisture and penetration by mobile ions, and helps to protect IC devices subjected to severe mechanical handling or circuit repair procedures. Process is compatible with variety of wire-bonded lead frame assemblies. Advantages over plasma and sputtering deposition processes are low deposition temperature and zero stray radiation and ion levels.

Hall, T. C.↗

Arctic sea-ice variations from time-lapse passive microwave imagery

This paper presents: (1) a short historical review of the passive microwave research on sea ice, which established the observational and theoretical base permitting the interpretation of the first passive microwave images of earth obtained by the Nimbus-5 ESMR; (2) the construction of a time-lapse motion picture film of a 16-month set of serial ESMR images to aid in the formidable data analysis task; and (3) a few of the most significant findings resulting from an early analysis of these data, using selected ESMR images to illustrate these findings.

Campbell, W. J.↗

A small, passively operated hydrogen maser

The paper describes a compact passive hydrogen maser with unique features including a reduction in size. It uses a passive operation mode, permitting the use of a small microwave TE(011) cavity dielectrically loaded by a low loss alumina. The Teflon coated quartz bulb common in other masers has been replaced by a Teflon coating on the inside wall of the cavity producing a simpler designed and a more rugged H-maser package. The cavity and the attached endcaps comprise the vacuum envelope, allowing the use of a single vacuum system. The dimensional stability of the ceramic cavity under barometric changes is sufficiently within the range of the electronic cavity servo so that a second vacuum system is not required. For temperature control, a single oven is located in the magnetic shield nest.

Howe, D. A.↗

Passive control of wing/store flutter

This paper presents results for a passive flutter suppression approach known as the decoupler pylon. The decoupler pylon dynamically isolates the wing from store pitch inertia effects by means of soft-spring/damper elements assisted by a low-frequency feedback-control system which minimizes static pitch deflections of the store due to maneuvers and changing flight conditions. Wind-tunnel tests and analyses show that this relatively simple pylon suspension system provides substantial increases in flutter speed and reduces the sensitivity of flutter to changes in store inertia and center-of-gravity location. Flutter characteristics of F-16 and YF-17 flutter models equipped with decoupler pylon-mount stores are presented and compared with results obtained on the same model configurations using active flutter suppression systems. These studies show both passive and active concepts to be effective in suppressing wing/store flutter. Also presented are data showing the influence of pylon stiffness nonlinearities on wing/store flutter.

Reed, W. H., III↗

Passive control of wing/store flutter

Results are presented for a passive flutter suppression approach known as the decoupler pylon. The decoupler pylon dynamically isolates the wing from store pitch inertia effects by means of soft spring/damper elements assisted by a low frequency feedback control system which minimizes static pitch deflections of the store because of maneuvers and changing flight conditions. Wind tunnel tests and analyses show that this relatively simple pylon suspension system provides substantial increases in flutter speed and reduces the sensitivity of flutter to changes in store inertia and center of gravity. Flutter characteristics of F-16 and YF-17 flutter models equipped with decoupler pylon mounted stores are presented and compared with results obtained on the same model configuration with active flutter suppression systems. These studies show both passive and active concepts to be effective in suppressing wing/store flutter. Also presented are data showing the influence of pylon stiffness nonlinearities on wing/store flutter.

Reed, W. H., III↗

The Passive Optical Sample Assembly (POSA) on STS-1

The passive optical sample assembly (POSA) hardware, scheduled for the flight on orbital flight test 1 is described. The function of the instrument is aid in the assessment contamination hazards to sensitive payloads in the shuttle cargo bay. It consists of an array of passively deployed samples mounted on the development flight instrumentation pallet in the shuttle cargo bay. The directory of samples together with their intended measurements are presented. The plan for POSA data analysis is also given.

Linton, R. C.↗