Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PV performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

Generic Photovoltaic Inverter Model in an Electromagnetic Transients Simulator for Transmission Connected Plants

This report proposes a generic model specification of a photovoltaic inverter applied in transmission-connected plants for implementation in an electromagnetic transients simulator. The model specification contains the necessary control loops to meet the fault ride-through performance requirements in the IEEE 2800-2022 standard. The report details the implementation and example parameterization of the model in PSCAD™. Simulation results verify the model meets the performance requirements. Comparisons of the model’s response to laboratory test measurements of a commercial 2.2 MVA storage inverter show the model can reasonably predict the response of commercial equipment.

14 SOLAR ENERGY↗

EMT Model Validation of a 2 MVA PV Inverter Using Transient and Frequency-Domain Hardware Testing: Preprint

This paper presents results and new insights gained from a hardware test campaign on a 2 MVA PV inverter for validating its vendor-supplied EMT model. The test campaign was conducted using a 7 MVA grid simulator and a 2 MW PV emulator. It considered both time-domain transient tests and frequency-domain impedance scan tests. The paper highlights the inadequacy of transient tests in capturing all critical resonance modes of the inverter, and the effectiveness of the frequency scan testing in addressing this problem. The paper shows the frequency scan testing as an effective tool for EMT model validation of IBR units which can highlight inaccuracies in the EMT models that are easy to overlook when model validation is performed using only the time-domain transient tests such as voltage ride-through and phase jump tests.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Laboratory evaluation of cyclic underground hydrogen storage in the Temblor sandstone of the San Joaquin Basin, California

Underground Hydrogen Storage (UHS) in depleted oil and gas reservoirs could provide a cost-effective solution to balance seasonal fluctuations in renewable energy generation. However, data and knowledge on UHS at subsurface conditions are limited so it is difficult to estimate how effective this type of storage could be. In this study, we perform high pressure experiment to measure the effectiveness of cyclic hydrogen (H 2 ) storage in a specimen of Temblor sandstone retrieved from the San Joaquin Basin of California. Our experiment mimics reservoir pressure conditions to measure H 2 -brine relative permeability and fluid-rock interactions over the course of ten charging and discharging cycles. Initial gas breakthrough occurred at 15 % to 25 % H2 saturation in the specimen with 3 % NaCl brine as the resident fluid. Continuing injecting to 4 pore volumes (PV) of H 2 yielded an asymptotic H 2 saturation of 38 % to 41 %, a level often referred to as the irreducible gas saturation based on two-phase flow. The boundary condition in this study mimics the near wellbore region, which experiences bi-directional H 2 flow. This bi-directional flow led to evaporative drying of the specimen resulting in 94 % H 2 saturation at the end of 10th cycle. This indicates that cyclic flow and evaporative drying can lead to more efficient reservoir storage where a larger fraction of the reservoir porosity is usable to store H 2 . The produced gas stream consisted of H 2 mixed with 8 % to 22 % H 2 O, indicating formation dry-out by evaporation. Meanwhile, produced water chemistry indicated calcite and silicate dissolution, with calcite sourced from fossil fragments. This led to a loss of cementation and weakened the rock sample. Combined, our results indicate dry-out, compaction, increased H 2 saturation, rock weakening, and permeability loss during cyclic UHS. Overall, we anticipate that the combined effects should lead to higher than anticipated UHS storage efficiency per volume of sandstone reservoir rock.

08 HYDROGEN↗

Recommendations for Data-in-Transit Requirements for Securing DER Communications

With the adoption of Distributed Energy Resource (DER) interoperability standards, common communication protocols are now being deployed between power system operators and DER devices. In 2018, a revision to the US interconnection and interoperability standard, Institute of Electrical and Electronics Engineers (IEEE) Std. 1547, required DER equipment to have an IEEE 2030.5, IEEE 1815, or SunSpec Modbus communication exchange interface. This change supports the future transition to secure connection and exchange of information between the DER equipment and implementing parties, such as grid operators. Adoption of standardized communication protocols and associated information models is a critical step toward interoperability between power system operators and DER, such as photovoltaic (PV) and energy storage systems. However, security requirements for these standardized communication protocols are not comprehensive, resulting in non-standard and vendor-specific implementation that may leave DER equipment susceptible to cyberattacks. This paper examines the data-in-flight security requirements for standardized DER communication protocols, per IEEE 1547-2018 revision, as it relates to device authentication, key management, and encryption. The state of the art for these security features is also explored, addressing their impact on communication and performance of low-cost single board computers, which are typical of DER devices. In conclusion, a recommendation is provided to adopt a common set of communication requirements, which are intended to achieve interoperability and implement data security over DER network pathways, while ensuring reliable, secure, and real-time information delivery.

42 ENGINEERING↗

Alternating Current Photovoltaic Effect

It is well known that the photovoltaic effect produces a direct current (DC) under solar illumination owing to the directional separation of light-excited charge carriers at the p–n junction, with holes flowing to the p-side and electrons flowing to the n-side. In this study, we found that apart from the DC generated by the conventional p–n photovoltaic effect, there is another new type of photovoltaic effect that generates alternating current (AC) in the nonequilibrium states when the illumination light periodically shines at the junction/interface of materials. The peak current of AC at high switching frequency can be much higher than that from DC. The AC cannot be explained by the established mechanisms for conventional photovoltaics; instead, it is suggested to be a result of the relative shift and realignment between the quasi-Fermi levels of the semiconductors adjacent to the junction/interface under the nonequilibrium conditions, which results in electron flow in the external circuit back and forth to balance the potential difference between two electrodes. By virtue of this effect, the device can work as a high-performance broadband photodetector with extremely high sensitivity under zero bias; it can also work as a remote power source providing extra power output in addition to the conventional photovoltaic effect.

36 MATERIALS SCIENCE↗

Fabrication of flexible perovskite solar cells via rapid thermal annealing

Adaptability, lightweight, and low cost of materials make flexible perovskite solar cells essential for the perovskite technology to breach commercial photovoltaic markets. Roll-to-roll manufacturing has great potential for high-throughput perovskite manufacturing; however, conventional annealing methods are not capable of producing flexible perovskite solar cells at scale. Conventional methods are time consuming and may compromise functionality of flexible substrates under tension. Here, we introduce a bladecoated perovskite thin film on flexible ITO-coated PET annealed via rapid thermal annealing (RTA) that reduces post-deposition processing time from ~150 s to ~14 s. As a result, performance was not sacrificed for scalability as a perovskite solar cell was produced with a power conversion efficiency (PCE) of 14.58%.

14 SOLAR ENERGY↗

Techno-Economic Analysis of Green Hydrogen Energy Storage in a Cryogenic Flux Capacitor

Abstract The Cryogenic Flux Capacitor (CFC) is a cold, dense energy storage core that is being studied in the cryo-compressed, about 300 bar and 80K, region of gaseous hydrogen (GH2) storage and liquid hydrogen (LH2) region near the normal boiling point. Hydrogen storage is improved by physically bonding the molecules within the nanoscale pores of the aerogel composite blanket material. The process of bonding or debonding is governed by principles of physical adsorption (physisorption) and thermodynamics. The large surface area afforded by the nanoporous aerogel (∼1,000 m2/g) allows its storage performance to easily exceed capacities of high-pressure GH2 storage for an equivalent volume. With the integrated aerogel, subscale tests have shown that storage is increased by about 36% over a simple tank filled with GH2 at the same operating temperature and pressure. For LH2 conditions, the CFC is shown to operate at improved densities, but testing is ongoing. For the techno-economic analysis (TEA), the source of hydrogen is compared between onsite steam methane reforming (SMR) and onsite solar photovoltaic (PV) panels providing power to electrolyzers to produce green GH2. The TEA compares pure hydrogen produced at a small scale for a 25 MW power system and at a large scale in a 500 MW power system. The system allowed for hydrogen imports and exports at a set price with a tank sized for 10 hours of power production. The two power producing technologies are a combined cycle gas turbine (CCGT) and hydrogen fuel cells. The SMR system uses natural gas as an input and includes a carbon capture and storage (CCS) system. The levelized cost of electricity (LCOE), levelized cost of hydrogen (LCOH), and levelized cost of storage (LCOS) are developed based on the capital cost and operating cost of the systems. The results are shown for current costs using a 2021 benchmark and DOE projections for cost improvements by 2030. The TEA showed that onsite hydrogen generation from SMR has an LCOH of about 1.4 to 2 USD per kg over the life of the plant and the PV hydrogen production LCOH is about 5.2 to 5.5 USD per kg. The LCOS of conventional GH2 systems is estimated to be $210/MWh and cost of storage for LH2 systems is $205/MWh for fuel cell systems and $249/MWh for CCGT systems. CFC improved the LCOS of all these systems to $198/MWh, $191/MWh and $233/MWh respectively. The LCOE also improved with conventional systems between $171/MWh and $228/MWh improved by CFC to between $167/MWh and $212/MWh. Using projections for improvement in costs following DOE’s goals by 2030, green hydrogen improved to as low as $78/MWh LCOS and LCOE for conventional cases. CFC improved over conventional storage with the lowest LCOS being $62/MWh and the lowest LCOE being $73/MWh. These results correspond to an LCOH of $2/kg. Finally, the TEA shows how LCOE is improved for hydrogen conditioning and storage over conventional systems and caverns in the 10 to 50 hour range.

08 HYDROGEN↗

PV Window Building Study

Data associated with the paper “Photovoltaic Windows to Offset the Intensive Energy and Carbon Footprints of Highly Glazed Buildings” by Vincent M. Wheeler, Janghyun Kim, Tom Daligault, Bryan Rosales, Chaiwat Engtrakul, Robert C. Tenent, and Lance M. Wheeler

14 SOLAR ENERGY↗

Adaptive Internal Model Based Current Control with Embedded Active Damping of a Three-Phase Grid-Connected Inverter with LCL Filter for PV Application

This paper presents an internal model based controller with embedded active damping for a three-phase grid-connected inverter with LCL filter. A strategy to control the grid current based on the internal model principle is presented in this paper. It is known that a third-order LCL filter apart from providing better attenuation also poses the problem of initiating unwanted resonance oscillations especially during transients. To address this problem, an active damping strategy based on virtual resistance emulation on the grid side filter is implemented. Also, to ensure effective active damping, an online parameter update strategy is implemented for the filter parameters. The proposed method provides better attenuation to oscillation damping and achieves good tracking performance without adversely affecting the bandwidth. The architecture is verified based on computer simulations via MATLAB/Simulink and PLECS domain and various important case study results are presented.

grid-connected inverter↗

GaAs solar cells grown on acoustically spalled GaAs substrates with 27% efficiency

Acoustic spalling presents a potentially low-cost reuse pathway for III–V epitaxial growth substrates via exfoliation of device layers with recovery and reuse of the substrate. However, surface features formed during spalling can reduce the performance of subsequently grown devices. Here, we develop an understanding of how the surface morphology of acoustically spalled substrates affects GaAs solar cell performance and develop strategies to mitigate these impacts. We demonstrate that minor planarization of the surface by wet chemical etching and/or epitaxial growth, or the redesign of the device structure to thicken critical layers, prevents performance degradation. Using these strategies, we demonstrate a 0.25 cm 2 single-junction GaAs device with 26.9% ± 0.2% photovoltaic conversion efficiency under the AM1.5G spectrum grown on an acoustically spalled substrate. These results enable the growth of high-performance III–V devices on non-traditional substrates with the potential for significantly reduced device costs.

14 SOLAR ENERGY↗

Defect Characterization of Monocrystalline Silicon Solar Cells with Polysilicon Passivated Contact Using Electrically-Detected Magnetic Resonance (EDMR) Spectroscopy

As the c-Si based solar cell efficiencies are approaching over 26%, it is becoming critical to characterize the low concentrations of the defects – as low as 10^10-10^11 cm-3 (for e.g., iron contamination in high-lifetime Ga-doped wafers3 and n-type wafers), and further reduce them. Also, atomistic level understanding of the mechanisms of the low concentration process-induced-defects and reliability limiting defects (such as light and elevated temperature induced degradation, surface passivation degradation) is needed to design the mitigation strategies. The conventional characterization techniques are limited due to their detection limitations. Some of the techniques based on lifetime spectroscopies can still be used for low concentration characterization however, they are based on estimations and theoretical models and hence, indirect and cannot fully reveal information about the microscopic mechanism of the defects. Thus, we present the application of an ultrasensitive magnetic resonance-based technique for the direct spectroscopic detection of the defects in Si PV - electrically detected magnetic resonance (EDMR). In this work, we aim to focus on establishing a process flow for fabrication of minicells with (miniature replica of the larger-area cells) and setting up the routine for EDMR measurements on them with the EDMR instrumentation capability at NREL. For the EDMR measurements, sample size is limited by the dimensions of sample holder tube (width less than 3.2 mm, active area - 20 mm). Thus, we have designed c-Si based minicells with polysilicon (poly-Si) passivated contacts same as the larger-area cells that we fabricate in our group at NREL. We also modified our minicell process flow for fabricating the textured minicells for preserving the texture during processing and taking care of the laser-ablation edge damage which can significantly affect the performance of such small devices. We have achieved comparable performance on these newly fabricated minicells as that of our 4 cm2 devices with same structure (comparable VOC, JSC, FF). We also conducted EDMR measurements on the minicells and observed a distinct EDMR signal at g-value ~2.005 at temperatures 30K and above, as shown in Fig. 2. We associate this signal to the presence of silicon dangling bonds based on the g-value. We also observed an EDMR signal at g-value ~1.998 at temperature ~5K. The origin of this signal is still being investigated. Thus, we show the proof of concept of minicells and EDMR measurements with which we now aim to study some of the unknown defects in silicon solar cell devices.

EDMR↗

Performance of III–V Solar Cells Grown on Reformed Mesoporous Ge Templates

We demonstrate a solar cell on reformed porous Ge with an efficiency of 7.7%. We generate mesopores in (100) Ge by bipolar electrochemical etching and anneal them at high temperature. The pores coalesce deep in the structure rather than at the surface as desired, although resulting in coarse superficial morphology unsuitable for device growth. To combat this issue, we developed a surface treatment involving an HBr dip, annealing at 415 degrees C, and a postannealing ultrasonic De-ionized water dip to improve the surface structure, resulting in a smoother reformed surface on which we grow a GaInAs solar cell. The structure retains embedded pores after growth and the transitions between Ge and III-V layers are distinct. The solar cell fabricated using the improved coalescence has an efficiency of 4.5%. The efficiency improves to 7.7% by isolating the rest of the device from three limiting localized shunt areas. Protruding defects in the porous Ge and III-V layers still limit the performance, but this work establishes a step toward the technical viability of this exfoliation approach, showing decent efficiency if protruding defects can be removed or reduced.

14 SOLAR ENERGY↗

Effective Dielectric Passivation Scheme in Area-Selective Front/Back Poly-Si/SiOx Passivating Contact Solar Cells

Despite the high efficiencies reached by heavily doped poly-Si/SiO x passivating contact solar cells, challenges like the high front parasitic absorption still limit their performance. Previously, we showed a wet etching technique using self-aligned metal grids to remove the front poly-Si in the non-metallized region. Here, we focus on the effective dielectric passivation on this tunneling oxide/n + in-diffused region. The effect of poly-Si thickness was studied to balance between the passivation quality and the current gain. We then compared various dielectric passivation schemes using SiN x , Al 2 O 3 , and stacks thereof via injection-level dependent lifetime and the transfer length method. We demonstrate a SiN x /Al 2 O 3 stack yielded the best passivation performance within device process limitation and obtained an improved front/back poly-Si/SiO x passivating contact device, with a short circuit current density of 41.8 mA/cm 2 and an efficiency of 21.8%.

anisotropic wet etching↗

PV O&M Cost Model [SWR-21-14]

This tool presents a method for calculating costs associated with the operation and maintenance (O&M) of photovoltaic (PV) systems. The tool compiles details regarding the cost and frequency of multiple O&M services to estimate annual O&M costs ($/year) for each year of an analysis period, the net present value ($) of life cycle costs accumulated over the analysis period, and the reserve account amount ($) that might be required to fund unexpected repairs. The reserve account includes parts inventory and is important for providing a source of funds to make repairs quickly and avoid lost production. This method allows a detailed selection of services to perform based on system size, market served (e.g., residential, commercial, or utility), type and configuration of system components (e.g., micro-, string, or central inverter), and site and environmental conditions (e.g., pollen, bird populations) which is an improvement over simple per unit valuations of O&M costs ($/kW/year). This model also distinguishes costs that vary from year to year and increase at different rates over time as modeled by heuristic failure distributions (e.g., Weibull or Lognormal distribution) based on actuarial data for many of the services.

Walker, Andy↗

Flexible Perovskite-Perovskite PV for Mobile Power Applications (Final Technical Report)

This is the final report for the referenced TCF award which ran from Oct. 2019 through Jan. 2024 in conjunction with the industry partner Swift Solar. The long duration of the program was due to several factors including the pandemic and a technical work stoppage due to changes in the scope. Additionally, Swift’s business focus shifted during the course of the program. As a result of these factors, this program underwent two distinct modifications that dramatically changed the work scope. The following report is organized into three separate sections, each of which addresses a distinct work scope. Those scope changes, what necessitated them, and any new tasks/milestones are given, briefly, at the top of each section. The work performed was research on the hybrid halide perovskites (HHP), both the absorber material itself as well as other material layers that are required in a full device stack. At the start of the period of performance, there were two distinct challenges that we sought to address: (1) a wide band gap absorber (>1.6 eV), and (2) a recombination layer for tandem devices that provided good sequestration of the individual cell absorber materials in their respective device layers. NREL had previously published, and patented, advancements in both of these areas and they were the focus of much of the work throughout the program.

14 SOLAR ENERGY↗

Hydrogen Production System Scaling Using a High-Fidelity Simulation-Optimization Framework

Proton exchange membrane (PEM) electrolyzers are widely used for hydrogen production, yet few validated, high-fidelity tools can reliably guide scale-up. Using measured performance from a 50-hour hardware-in-the-loop pilot test, a physics-based, plant-level model of a 1.25 MW PEM electrolyzer and its balance-of-plant (BoP) subsystems is developed and validated. The model couples electrochemistry and thermal/flow submodels and is calibrated against pilot test data via a genetic algorithm (GA) workflow. Validation yields a mean absolute percentage error (APE) of 0.43% for cell voltage and stack power. Two scale-out strategies are then benchmarked under a common 7-day wind-and-photovoltaic (PV) profile: (i) linear duplication of 1.25 MW blocks and (ii) shared-BoP architectures. Sharing BoP between stacks reduces BoP energy by 27% at 10 MW and 34% at 100 MW (vs. linear duplication) and improves system specific energy consumption (SEC) to 52.9 and 52.6 kWh/kg, respectively (from 54.0 kWh/kg with linear duplication). Partial-load studies (25-100% set-point) show that cumulative hydrogen production remains nearly constant down to 50% load because all cases use the same weekly renewable-energy input. Below 50%, the power cap limits how much energy can be used within 168 h, which reduces hydrogen output. The model further indicates that the practical operating optimum lies between 50% and 85% load, where efficiency gains begin to appear without significant loss in hydrogen output. Moreover, the efficiency gains at lower loads are offset by reduced production. The validated framework supports scenario-based engineering trade-off studies for large configurations (10-100 MW) and for operating policies under variable renewables.

08 HYDROGEN↗

Extended Accelerated Stress Testing (EAST) of Glass/Glass, Glass/Backsheet and Glass/Transparent Backsheet PV Modules: Influence of EVA and POE Encapsulants: Preprint

This paper presents the indoor extended accelerated stress testing (EAST) results of glass/glass (GG), glass/backsheet (GB) and glass/transparent backsheet (GT) modules having identical cells and two different encapsulant types, ethyl-vinyl-acetate (EVA) and polyolefin-elastomer (POE). Six 4-cell modules having the above-mentioned construction combinations were subjected to extended ultraviolet (UV; 600 kWh/m2), damp-heat (DH; 2000 hours) and thermal-cycling (TC; 600 cycles) tests. The post-stress UV fluorescent imaging, electroluminescent imaging, reflectance spectrophotometry and colorimetry results indicated that the grid finger degradation and encapsulant browning are slightly higher in the GG modules compared to the GB modules. The post-stress IV test results indicated, in general, that the GG/EVA modules tend to perform inferior to the GG/POE modules with the EAST evaluation.

EVA↗