Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PROBE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

DNA Probe Pooling for Rapid Delineation of Chromosomal Breakpoints

Structural chromosome aberrations are hallmarks of many human genetic diseases. The precise mapping of translocation breakpoints in tumors is important for identification of genes with altered levels of expression, prediction of tumor progression, therapy response, or length of disease-free survival as well as the preparation of probes for detection of tumor cells in peripheral blood. Similarly, in vitro fertilization (IVF) and preimplantation genetic diagnosis (PGD) for carriers of balanced, reciprocal translocations benefit from accurate breakpoint maps in the preparation of patient-specific DNA probes followed by a selection of normal or balanced oocytes or embryos. We expedited the process of breakpoint mapping and preparation of case-specific probes by utilizing physically mapped bacterial artificial chromosome (BAC) clones. Historically, breakpoint mapping is based on the definition of the smallest interval between proximal and distal probes. Thus, many of the DNA probes prepared for multi-clone and multi-color mapping experiments do not generate additional information. Our pooling protocol described here with examples from thyroid cancer research and PGD accelerates the delineation of translocation breakpoints without sacrificing resolution. The turnaround time from clone selection to mapping results using tumor or IVF patient samples can be as short as three to four days.

60 APPLIED LIFE SCIENCES↗

STANDING WAVE PROBES FOR DIMENSIONAL METROLOGY OF LOW DENSITY FOAMS

Typically, parts and geometries of interest to LLNL are made from a combination of complex geometries and a wide array of different materials ranging from metals and ceramics to low density foams and plastic foils. These parts are combined to develop physics experiments for studying material properties, equation of state (EOS) and radiation transport. Understanding the dimensional uncertainty of the parts contained within an experiment is critical to the physical understanding of the phenomena being observed and represents the motivation for developing probe metrology capability that can address LLNL's unique problems. Standing wave probes were developed for measuring high aspect ratio, micrometer scaled features with nanometer resolution. Originally conceived of for the use in the automotive industry for characterizing fuel injector bores and similar geometries, this concept was investigated and improved for use on geometries and materials important to LLNL needs within target fabrication. As part of the original project, detailed understanding of the probe dynamics and interactions with the surface of the sample was investigated. In addition, the upgraded system was utilized for measuring fuel injector bores and micro-lenses as a means of demonstrating capability. This report discusses the use of the standing wave probe for measuring features in low density foams, 55 mg/cc SiO{sub 2} and 982 mg/cc (%6 relative density) copper foam respectively. These two foam materials represent a difficult metrology challenge because of their material properties and surface topography. Traditional non-contact metrology systems such as normal incident interferometry and/or confocal microscopy have difficulty obtaining a signal from the relatively absorptive characteristics of these materials. In addition to the foam samples, a solid copper and plastic (Rexolite{trademark}) sample of similar geometry was measured with the standing wave probe as a reference for both conductive and dielectric materials.

42 ENGINEERING↗

Indirect Validation of Probe Speed Data on Arterial Corridors

This study aimed to estimate the accuracy of probe speed data on arterial corridors on the basis of roadway geometric attributes and functional classification. It was assumed that functional class (medium and low) along with other road characteristics (such as weighted average of the annual average daily traffic, average signal density, average access point density, and average speed) were available as correlation factors to estimate the accuracy of probe traffic data. This study tested these factors as predictors of the fidelity of probe traffic data by using the results of an extensive validation exercise. This study showed strong correlations between these geometric attributes and the accuracy of probe data when they were assessed by using average absolute speed error. Linear models were regressed to existing data to estimate appropriate models for medium- and low-type arterial corridors. The proposed models for medium- and low-type arterials were validated further on the basis of the results of a slowdown analysis. These models can be used to predict the accuracy of probe data indirectly in medium and low types of arterial corridors.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

X-ray Pump–Probe Investigation of Charge and Dissociation Dynamics in Methyl Iodine Molecule

Molecular dynamics is of fundamental interest in natural science research. The capability of investigating molecular dynamics is one of the various motivations for ultrafast optics. Here, we present our investigation of photoionization and nuclear dynamics in methyl iodine (CH 3 I) molecule with an X-ray pump X-ray probe scheme. The pump–probe experiment was realized with a two-mirror X-ray split and delay apparatus. Time-of-flight mass spectra at various pump–probe delay times were recorded to obtain the time profile for the creation of high charge states via sequential ionization and for molecular dissociation. We observed high charge states of atomic iodine up to 29+, and visualized the evolution of creating these high atomic ion charge states, including their population suppression and enhancement as the arrival time of the second X-ray pulse was varied. We also show the evolution of the kinetics of the high charge states upon the timing of their creation during the ionization-dissociation coupled dynamics. We demonstrate the implementation of X-ray pump–probe methodology for investigating X-ray induced molecular dynamics with femtosecond temporal resolution. The results indicate the footprints of ionization that lead to high charge states, probing the long-range potential curves of the high charge states.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

SISGR: Atom chip microscopy: A novel probe for strongly correlated materials

Microscopy techniques co-opted from nonlinear optics and high energy physics have complemented solid-state probes in elucidating the order manifest in condensed matter materials. Up until now, however, no attempts have been made to use modern techniques of ultracold atomic physics to directly explore properties of strongly correlated or topologically protected materials. Our current program is focused on introducing a novel magnetic field microscopy technique into the toolbox of imaging probes. Our prior DOE ESPM program funded the development of a novel instrument using a dilute gas Bose-Einstein condensate (BEC) as a scanning probe capable of measuring tiny magnetic (and electric) DC and AC fields above materials. We successfully built the world's first “scanning cryogenic atom chip microscope”, and we now are in the process of characterizing its performance before using the instrument to take the first wide-area images of transport flow within unconventional superconductors, pnictides and oxide interfaces (LAO/STO), topological insulators, and colossal magnetoresistive manganites. We will do so at temperatures outside the capability of scanning SQUIDs, with ~10x better resolution and without 1/f-noise. A notable goal will be to measure the surface-to-bulk conductivity ratio in topological insulators in a relatively model-independent fashion. We have completed the construction of this magnetic microscope. The instrument uses atom chips—substrates supporting micron-sized current-carrying wires that create magnetic microtraps near surfaces for ultracold thermal gases and BECs—to enable single-shot and raster-scanned large-field-of-view detection of magnetic fields. The fields emanating from electronic transport may be detected at the 10 -7 flux quantum (Φ0) level and below; that is, few to sub-micron resolution of sub-nanotesla fields over single-shot, millimeter-long detection lengths. By harnessing the extreme sensitivity of atomic clocks and BECs to external perturbations, we are now in a position to use atom chips for imaging transport in new regimes. Scanning quantum gas atom chip microscopy introduces three very important features to the toolbox of high-resolution scanning microscopy of strongly correlated or topological materials: simultaneous detection of magnetic and electric fields (down to the sub-single electron charge level; no invasive large magnetic fields or gradients; simultaneous micro- and macroscopic spatial resolution; DC to MHz detection bandwidth; freedom from 1/ƒ flicker noise at low frequencies; and, perhaps most importantly, the complete decoupling of probe and sample temperatures. The atom chip microscope can operate at maximum sensitivity and resolution without regard to the substrate temperature. While the BEC is among the coldest objects realizable (100 nK temperatures are typical), the atom chip substrate can be positioned 1 μm away from the BEC and be as hot as 400 K or as cold as the cryostat can cool. This is because unlike superconducting probes, whose temperature is closely coupled to nearby materials, quantum gases are immune to radiative heating. The energy gap between a Rb atom’s ground state and first excited state far exceeds the typical energy of room-temperature blackbody radiation; such atoms are therefore transparent to radiation heating by materials at room temperature or below. We experimentally demonstrated a new atom chip trapping system that allows the placement and high-resolution imaging of ultracold atoms within microns from any ≤100 μm-thin, UHV-compatible material, while also allowing sample exchange with minimal experimental downtime. The sample is not connected to the atom chip, allowing rapid exchange without perturbing the atom chip or laser cooling apparatus. Exchange of the sample and retrapping of atoms has been performed within a week turnaround, limited only by chamber baking. Moreover, the decoupling of sample and atom chip provides the ability to independently tune the sample temperature and its position with respect to the trapped ultracold gas, which itself may remain in the focus of a high-resolution imaging system. We confine 100-nK BECs of 104 87Rb atoms near a gold-mirrored 100-μm-thick silicon substrate. The substrate can be cooled to 35 K without use of a heat shield, while the atom chip, 120-μm away, remains at room temperature. Atoms may be imaged with 1-μm resolution and retrapped every 16 s, allowing rapid data collection. Straightforward improvements will allow us to push sample temperatures close to 4 K, and improve imaging resolution from 1 μm down to a few-100 nm, thereby providing 10 -9 Φ0 detection sensitivity. We will test the utility of this technique by imaging the magnetic fields emanating from electronic transport and domain percolation in several interesting examples of strongly correlated or topologically protected materials. STM, transport, and x-ray scattering experiments have, among others, revealed the existence of a quantum liquid crystal state in iron (pnictide) and cuprate superconductors. This strongly correlated state of matter could also be detected by imaging the fluctuating transport (spatially and in time) of electrons as the phase/regime boundary is crossed between the pnictide non-Fermi liquid (cuprate strange metal) and the pnictide magnetic phase (cuprate pseudogap regime). Our ability to image wide-area inhomogeneous current flow from room-temperature to <10 K will allow us to study the developing domain structure and transport near twin boundary interfaces through the T N ≈50–150 K nematic transition recently identified in bulk transport experiments by Ian Fisher's group in underdoped Fe-arsinide superconductors. Again, this highlights a main feature of our cryogenic atom chip microscope: the ability to image transport regardless of the sample temperature since the BEC, at nK temperatures, is transparent to blackbody radiation, even when held a microns from the surface.

36 MATERIALS SCIENCE↗

INVESTIGATING SCALING LIMITS OF A FIBER BASED RESONANT PROBE FOR METROLOGY APPLICATIONS

Currently, Inertial Confinement Fusion (ICF) and High Energy Density Science (HEDS) targets comprise components with dimensions in the millimeter range, while having micrometerscale, high aspect ratio functional features, including fill-tube holes and counterbores, slotted patterns, and step-joint geometry on hemispherical targets. Representative geometry is shown in Figure 1. Future target designs will likely have additional challenging features. The dimensional metrology of these features is important for a number of reasons, including quantifying geometrical tolerances of as-built components prior to delivery, qualification of sub-components prior to assembly, and as a feedback mechanism for fabrication process development. Variations in geometry from part to part can lead to functional limitations, such as limited flow rates during target filling, unpredictable instabilities during an experiment, and the inability to assemble a target from poorly matched sub-components. Adding to the complexity are the large number and variety of materials, components, and shapes that render any single metrology technique difficult to use with low uncertainty. Adapting standing wave probe technology [i] for micrometer sized features requires the understanding of the physical interaction between the oscillating, slender rod (probe) and the sample as a means of transferring information about the surface, such as topography and material properties, analogous to tapping mode atomic force microscopy (AFM) and/or instrumented indentation machines. By utilizing the variation in dynamic response of the probe as the tip interacts with a surface, information about the sample may be obtained and used for mapping surface topography, and potentially characterizing material properties. The novel long aspect ratio geometry of the probe enables the characterization of features such as small holes, slots, and corners, which typically cannot be accessed using AFM and instrumented indentation technology. Uncertainty of the surface location is a combination of near surface effects such as van der Waals and electrostatic forces combined with contact force such adhesion and meniscus contributions. In addition, environmental effects, such as thermal gradients and air turbulence, will influence probe performance and repeatability. A combination of complex nonlinear models of the tuning fork driver/sensor mechanics, fiber dynamics, circuit response and contact interactions have been developed for the current scale system in an effort to predict scaling limitations of this technology for characterizing micrometer sized features with nanometer sensitivity.

42 ENGINEERING↗

Parametric study of expanding plasma plume formed by laser-blow-off of thin film using triple Langmuir probe

The triple probe technique has been used to study the parameters of flowing plasma plume formed by laser-blow-off (LBO) of a multicomponent LiF-C target. The advantages of triple Langmuir probe over the single probe have been discussed with regard to the present study. Our results show that triple probe is better suited for parametric measurements close to the target. The spatiotemporal evolutions of electron density and temperature were measured in different ambient environments and for various laser fluences. The angular distribution of electron density and temperature was also measured. It was found that the presence of ambient gas drastically affects the electron density and temperature of the LBO plume. Large enhancement in n{sub e} and T{sub e} at intermediate pressures (10{sup -2} Torr) is expected due to increase in collisional processes. On the other hand, laser fluence does not affect the observed n{sub e} and T{sub e} significantly. In vacuum, a new phenomenon, i.e., an oscillation in the trailing portion of the plasma plume at a closer distance from the target, is also reported.

36 MATERIALS SCIENCE↗

A Photoactivatable BODIPY Probe for Localization‐Based Super‐Resolution Cellular Imaging

Abstract The synthesis and application of a photoactivatable boron‐alkylated BODIPY probe for localization‐based super‐resolution microscopy is reported. Photoactivation and excitation of the probe is achieved by a previously unknown boron‐photodealkylation reaction with a single low‐power visible laser and without requiring the addition of reducing agents or oxygen scavengers in the imaging buffer. These features lead to a versatile probe for localization‐based microscopy of biological systems. The probe can be easily linked to nucleophile‐containing molecules to target specific cellular organelles. By attaching paclitaxel to the photoactivatable BODIPY, in vitro and in vivo super‐resolution imaging of microtubules is demonstrated. This is the first example of single‐molecule localization‐based super‐resolution microscopy using a visible‐light‐activated BODIPY compound as a fluorescent probe.

Wijesooriya, Chamari S.↗

A Photoactivatable BODIPY Probe for Localization-based Super-Resolution Cellular Imaging

Here, the synthesis and application of a photoactivatable boron–alkylated BODIPY probe for localization–based super–resolution microscopy is reported. Photoactivation and excitation of the probe is achieved by a previously–unknown boron–photodealkylation reaction with a single low–power visible laser and without requiring the addition of reducing agents or oxygen scavengers in the imaging buffer. These features lead to a versatile probe for localization–based microscopy of biological systems. The probe can be easily linked to nucleophile–containing molecules to target specific cellular organelles. By attaching paclitaxel to the photoactivatable BODIPY, in vitro and in vivo super–resolution imaging of microtubules is demonstrated. This is the first example of single molecule localization–based super–resolution microscopy using a visible–light activated BODIPY compound as a fluorescent probe.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Metabolic Incorporation of N ‐Acetyl Muramic Acid Probes into Bacterial Peptidoglycan

Abstract Bacterial cells utilize small carbohydrate building blocks to construct peptidoglycan (PG), a highly conserved mesh‐like polymer that serves as a protective coat for the cell. PG production has long been a target for antibiotics, and its breakdown is a source for human immune recognition. A key component of bacterial PG, N ‐acetyl muramic acid (NAM), is a vital element in many synthetically derived immunostimulatory compounds. However, the exact molecular details of these structures and how they are generated remain unknown due to a lack of chemical probes surrounding the NAM core. A robust synthetic strategy to generate bioorthogonally tagged NAM carbohydrate units is implemented. These molecules serve as precursors for PG biosynthesis and recycling. Escherichia coli cells are metabolically engineered to incorporate the bioorthogonal NAM probes into their PG network. The probes are subsequently modified using copper‐catalyzed azide‐alkyne cycloaddition to install fluorophores directly into the bacterial PG, as confirmed by super‐resolution microscopy and high‐resolution mass spectrometry. Here, synthetic notes for key elements of this process to generate the sugar probes as well as streamlined user‐friendly metabolic labeling strategies for both microbiology and immunological applications are described. © 2019 by John Wiley & Sons, Inc. Basic Protocol 1 : Synthesis of peracetylated 2‐azido glucosamine Basic Protocol 2 : Synthesis of 2‐azido and 2‐alkyne NAM Basic Protocol 3 : Synthesis of 3‐azido NAM methyl ester Basic Protocol 4 : Incorporation of NAM probes into bacterial peptidoglycan Basic Protocol 5 : Confirmation of bacterial cell wall remodeling by mass spectrometry

DeMeester, Kristen E.↗

A novel mitochondria-targeted two-photon fluorescent probe for dynamic and reversible detection of the redox cycles between peroxynitrite and glutathione

Highlights: • We report a two-photon fluorescent probe (TP-Se) for optical imaging. • TP-Se can monitor reversibly changes in ONOO{sup −}/GSH levels in mitochondria. • TP-Se will lead to significant development on redox events in cellular redox regulation. Redox homeostasis is important for maintenance of normal physiological functions within cells. Redox state of cells is primarily a consequence of precise balance between levels of reducing equivalents and reactive oxygen species. Redox homeostasis between peroxynitrite (ONOO{sup −}) and glutathione (GSH) is closely associated with physiological and pathological processes, such as prolonged relaxation in vascular tissues and smooth muscle preparations, attenuation of hepatic necrosis, and activation of matrix metalloproteinase-2. We report a two-photon fluorescent probe (TP-Se) based on water-soluble carbazole-based compound, which integrates with organic selenium, to monitor changes in ONOO{sup −}/GSH levels in cells. This probe can reversibly respond to ONOO{sup −} and GSH and exhibits high selectivity, sensitivity, and mitochondrial targeting. The probe was successfully applied to visualize changes in redox cycles during ONOO{sup −} outbreak and antioxidant GSH repair in cells. The probe will lead to significant development on redox events involved in cellular redox regulation.

60 APPLIED LIFE SCIENCES↗

Microscale dynamics in thermoreversible hydrogels: Impact of probe size and concentration

Passive microrheology techniques using dynamic light scattering (DLS) and X-ray photon correlation spectroscopy (XPCS) have emerged as important techniques for characterizing the dynamics and viscoelastic properties of soft polymeric biomaterials. However, the impact of probe particle type, size, and concentration are important considerations in interpretation of results and comparison to properties obtained from bulk rheology measurements. In this work, we investigate a model thermoreversible polymeric hydrogel and compare results from DLS-microrheology with different size and concentrations of polystyrene probe particles and XPCS-microrheology with inorganic nanoparticles. We obtained trends that aligned most closely with the macroscopic rheology with probe particles that are slightly larger than the characteristic length scale of the gel structure, but within the same order of magnitude. By contrast, larger probe particles yielded microrheology data that are more dominated by elastic behavior than what we might expect from bulk rheology experiments, while use of small inorganic nanoparticles in XPCS-microrheology resulted in a more a more viscous response than would be expected based on the bulk rheology. Finally, this study demonstrates the utility of passive DLS- and XPCS-based microrheology in characterizing the rheological properties of complex polymeric biomaterials, while also highlighting important considerations in experimental design and choice of type, size, and concentration of probe particles used.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Atomic and ionic hydrogen flux probe for quantitative in-situ monitoring of hydrogen recycling

A new combination diagnostic as a hydrogen recycling monitor in harsh conditions is proposed. Combining permeation membrane probe with a Langmuir probe provides a possibility to measure both atomic and ionic hydrogen fluxes to plasma facing components. A brief overview of permeation probes is given. The range of measurable H fluxes is from 10 16 to more than 10 20 H m –2 s –1 . Time response of the permeation probe is ~ 0.1–0.5 s. A method to address disadvantages of permeation probes is proposed. This includes an introduction of a preparation chamber for Ar-plasma cleaning of the membrane and absolute calibration with a visible spectroscopy. The hydrogen recombination coefficient, evaluated in such calibration, is k u = 5.9 × 10 –30 m 4 s –1 , which agrees well with previous research.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Transport of tungsten to collector probes in DIII-D

Collector probes have long been used to measure impurity fluxes in the scrape off layer (SOL) of tokamaks. In this study, collector probes were inserted in the main SOL of DIII-D during the tungsten Metal Rings Campaign, and the W deposits on the probes were analyzed ex situ using Rutherford backscattering spectrometry analysis to obtain radial profiles of W deposition. A simple picture is hypothesized for how the W transports through the SOL from the target to the two sides of the probe, based on a long-theorized impurity accumulation at the crown (i.e. the top) of the plasma. The patterns observed in the deposition profiles along the probes support the hypothesized picture; however, 3D modeling and further experimental studies are needed to support more definitive conclusions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Patterned probes for high precision 4D-STEM bragg measurements

Nanoscale strain mapping by four-dimensional scanning transmission electron microscopy (4D-STEM) relies on determining the precise locations of Bragg-scattered electrons in a sequence of diffraction patterns, a task which is complicated by dynamical scattering, inelastic scattering, and shot noise. These features hinder accurate automated computational detection and position measurement of the diffracted disks, limiting the precision of measurements of local deformation. Here, we investigate the use of patterned probes to improve the precision of strain mapping. We imprint a "bullseye" pattern onto the probe, by using a binary mask in the probe-forming aperture, to improve the robustness of the peak finding algorithm to intensity modulations inside the diffracted disks. We show that this imprinting leads to substantially improved strain-mapping precision at the expense of a slight decrease in spatial resolution. In experiments on an unstrained silicon reference sample, we observe an improvement in strain measurement precision from 2.7% of the reciprocal lattice vectors with standard probes to 0.3% using bullseye probes for a thin sample, and an improvement from 4.7% to 0.8% for a thick sample. Additionally, we use multislice simulations to explore how sample thickness and electron dose limit the attainable accuracy and precision for 4D-STEM strain measurements.

47 OTHER INSTRUMENTATION↗

Direct Surface and Droplet Microsampling for Electrospray Ionization Mass Spectrometry Analysis with an Integrated Dual-Probe Microfluidic Chip

Ambient mass spectrometry (MS) has revolutionized the way of MS analysis and broadened its application in various fields. This paper describes the use of microfluidic techniques to simplify the setup and improve the functions of ambient MS by integrating the sampling probe, electrospray emitter probe, and online mixer on a single glass microchip. Two types of sampling probes, including a parallel-channel probe and a U-shaped channel probe, were designed for dryspot and liquid-phase droplet samples, respectively. We demonstrated that the microfabrication techniques not only enhanced the capability of ambient MS methods in analysis of dry-spot samples on various surfaces, but also enabled new applications in the analysis of nanoliter-scale chemical reactions in an array of droplets. The versatility of the microchip-based ambient MS method was demonstrated in multiple different applications including evaluation of residual pesticide on fruit surfaces, sensitive analysis of low-ionizable analytes using postsampling derivatization, and high-throughput screening of Ugi-type multicomponent reactions.

Huang, Cong-Min↗

X-ray and Optical Circular Dichroism as Local and Global Ultrafast Chiral Probes of [12]Helicene Racemization

Optical circular dichroism (OCD) is a well-established technique for probing molecular chirality typically in the UV-visible window. Although molecular chirality is usually related to a chiral center, it can alternatively describe a global structure. The electronic transitions are then delocalized and OCD is said to probe the global chirality. Recent advances controlling the polarization and spatial structure of X-ray beams have led to novel spectroscopic techniques such as X-ray circular dichroism (XCD), which can exploit the localized nature of the X-ray electronic transitions. XCD is thus sensitive to local structures and the relevant chirality probed with it can be referred as local. Here, we use the racemization mechanism of the [12]Helicene as a model to assess the capabilities of OCD and XCD as probes of global and local chiralities. In conclusion, our simulations suggest that XCD is a reliable spectroscopic technique for probing the local chirality of molecules, suggesting the further development of this experimental technique.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Probing many-body dynamics in a two-dimensional dipolar spin ensemble

Abstract The most direct approach for characterizing the quantum dynamics of a strongly interacting system is to measure the time evolution of its full many-body state. Despite the conceptual simplicity of this approach, it quickly becomes intractable as the system size grows. An alternate approach is to think of the many-body dynamics as generating noise, which can be measured by the decoherence of a probe qubit. Here we investigate what the decoherence dynamics of such a probe tells us about the many-body system. In particular, we utilize optically addressable probe spins to experimentally characterize both static and dynamical properties of strongly interacting magnetic dipoles. Our experimental platform consists of two types of spin defects in nitrogen delta-doped diamond: nitrogen-vacancy colour centres, which we use as probe spins, and a many-body ensemble of substitutional nitrogen impurities. We demonstrate that the many-body system’s dimensionality, dynamics and disorder are naturally encoded in the probe spins’ decoherence profile. Furthermore, we obtain direct control over the spectral properties of the many-body system, with potential applications in quantum sensing and simulation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗