Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “POWER DEMAND”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

Quantum/AI Topology-Aware Latency-Adaptive HPC Workflow Scheduling Optimization

The growing demand for more powerful high-performance computing (HPC) systems has led to a steady rise in energy consumption by supercomputing worldwide. This study is focused on comparing our Application-Topology Mapper (ATMapper) to the popular Simple Linux Utility for Resource Management (SLURM) for the purpose of exploring methods that can further optimize job-scheduling within HPC systems. ATMapper is an Artificial-Intelligence based approach to job-scheduling that is currently being enhanced with quantum annealing (QA) to generate optimal schedules faster. We are applying QA to speedup our ATMapper process to achieve higher computing efficiency, thereby reducing HPC energy consumption. Here, we examine how four job-scheduling approaches perform in processor node assignment when using an example network architecture of 4 interconnected nodes. Using a specialized script, we are assessing the schedule of a computation flow with 11 interdependent tasks. The data movements among nodes were tracked to count for the number of interactions (network hops) between nodes needed to complete the tasks. The total number of hops and the job completion time were then used to quantify the efficiency of the different mapping approaches. In addition to SLURM, we also compare our ATMapper to the QA-enabled LBNL TIGER and the D-Wave Distributed Computing processor assignment approaches. The preliminary results showed that our topology-aware, latency-adaptive ATMapper is significantly more efficient when compared to the other scheduling approaches due to its load-imbalance network allocation. The scheduler displayed a computing efficiency of 53% by performing significantly fewer network hops than its alternatives. By reducing the number of hops, ATMapper was able to perform all 11 tasks by using only 3 nodes out of given 4. This research indicates the potential to use QA/AI for HPC job-scheduling. Later, we will test a SLURM simulator program to draw further comparisons on the effectiveness of ATMapper's scheduling approach. The results of this comparison will serve as a baseline for later improving SLURM's performance using a QA-enhanced ATMapper approach.

Caraveo, Braulio [University of Huston - Clear Lak↗

Distributed Load Sharing Under False Data Injection Attack in an Inverter-Based Microgrid

In microgrids, distributed load sharing plays an important role in maintaining the supply-demand balance of power. Because false data injection (FDI) is one of the crucial threats faced by future microgrids, the study of the impact of FDI on distributed load sharing is both of theoretical merit and practical value. Here, we consider the distributed load sharing problem of the microgrids operating in autonomous mode under FDI. Each bus is assumed to be equipped with an agent. Under a well-developed distributed load sharing protocol based on multiagent systems, we first construct an FDI attack model, where the attacker is capable of injecting false data into the bus agents. Finally, a utilization level is introduced for coordinating generators, and its variation is evaluated in the presence of FDI attacks with given injection strategies. The stable region of the microgrid is defined, and conditions are given to determine stability. In conclusion, theoretical results are validated on the Canadian urban distribution system.

24 POWER TRANSMISSION AND DISTRIBUTION↗

An experimentally validated electro-thermal EV battery pack model incorporating cycle-life aging and cell-to-cell variations

Lithium-ion batteries are used in a wide variety of applications. To meet the power and energy demands of these applications battery packs are composed of hundreds to thousands of cells. The electrical and thermal interactions between cells introduce additional complexity in the pack dynamics. To capture these effects, a battery pack model composed of 192 cells based on a first-generation (2012) Nissan Leaf battery pack is developed in MATLAB/Simulink/Simscape. Here, with this model, we simulate the electrical dynamics (using a first-order equivalent-circuit model), the thermal dynamics (using a first-order lumped-parameter thermal model), and the aging dynamics (using a semi-empirical severity factor-based model) of every cell in the pack and we also create a pack thermal model that explicitly captures the heat exchange between the modules, and the cells contained within, during operation. The models are calibrated and validated, both at the cell and pack level, with experimental data. Two different case studies of this pack model are investigated. In the first case study, an initial, normally-distributed, cell-to-cell capacity variation is introduced and its effect on the pack voltage and module temperatures is studied. In the second case study, we deliberately insert cells with lower than nominal capacity into the pack and we investigate how this type of initial cell-to-cell capacity variation affects the pack’s ability to deliver energy over time. Finally, we also study how parallel-connected cells can reduce the effects of cell-to-cell variations at the expense of increased aging of the pack overall.

25 ENERGY STORAGE↗

Stochastic Simulation Service: Bridging the Gap between the Computational Expert and the Biologist

We present StochSS: Stochastic Simulation as a Service, an integrated development environment for modeling and simulation of both deterministic and discrete stochastic biochemical systems in up to three dimensions. An easy to use graphical user interface enables researchers to quickly develop and simulate a biological model on a desktop or laptop, which can then be expanded to incorporate increasing levels of complexity. StochSS features state-of-the-art simulation engines. As the demand for computational power increases, StochSS can seamlessly scale computing resources in the cloud. In addition, StochSS can be deployed as a multi-user software environment where collaborators share computational resources and exchange models via a public model repository. We also demonstrate the capabilities and ease of use of StochSS with an example of model development and simulation at increasing levels of complexity.

59 BASIC BIOLOGICAL SCIENCES↗

Influence of Diffuse and Ground-Reflected Irradiance on the Spectral Modeling of Solar Reference Cells

Thermal Energy Storage (TES) is a key component for solar thermal applications to bridge the gap between the demand for thermal energy and the supply of solar energy, whose availability depends on the time of day and season. Thus, cost-effective packed-bed thermal containers filled with a solid storage medium have been proposed for high-temperature sensible heat storage as materials are abundant and relatively cheap. Thus, it is necessary to investigate their performance and temperature profiles during the charge-discharge cycle. Several models are available for this purpose. Typically, the more detailed a model, the greater the computational effort required to solve it, and hence a time-efficient model is needed to prevent excessively long computation times for long-term analysis. At the more basic level, the common Hughes E-NTU model and the less realistic simplified Infinite-NTU model are very important for their less time and computational effort. In this paper, the appropriateness of employing the Infinite-NTU model was evaluated to investigate the performance of a typical and scalable rock-bed TES as a case study. The results presented provide a methodology to quickly test the validity of the model and predict the temperature profile for the case under study. Accordingly, such simple charge-discharge cycle thermal performance predictions are important to plan, design, and rapidly deploy a reliable and economical solar thermal system for the supply of valuable heat to high-temperature demanding applications of power generation and industrial processes as part of a rapid shift towards non-polluting renewable energy. Keywords: Solar Thermal, TES, Packed-bed, NTU model, Temperature profile

PV modeling↗

Solar Installation Labor Market Analysis

The potential economic benefits of the growing renewable energy sector have led to increased federal, state, and local investments in solar industries, including federal grants for expanded workforce training for U.S. solar installers. However, there remain gaps in the data required to understand the size and composition of the workforce needed to meet the demand for solar power. Through primaryresearch on the U.S. solar installation employer base, this report seeks to address that gap, improving policymakers' and other solar stakeholders' understanding of both the evolving needs of these employers and the economic opportunity associated with solar market development. Included are labor market data covering current U.S. employment, expected industry growth, and employer skillpreferences for solar installation-related occupations. This study offers an in-depth look at the solar installation sectors. A study published by the Solar Foundation in October 2011 provides a census of labor data across the entire solar value chain.

14 SOLAR ENERGY↗

New Methods of Uncertainty Quantification for Mixed Discrete-Continuous Variable Models

The scale and complexity of problems such as designing power grids or planning for climate change is growing rapidly, driving the development of complicated computer models. More complex models have longer run times and incorporate larger numbers of inputs, both continuous and discrete. For example, a detailed physics model may have continuous variables such as temperature, height or pressure along with discrete variables that indicate the choice of a material for a particular piece or the model to be used to calculate air flow. A power grid design model may have continuous variables such as generation capacity, power flow or demand along with discrete variables such as number of generators, number of transmission lines or binary variables to indicate whether or not a node is chosen for generation expansion. A growing awareness of uncertainty and the desire to make risk-informed decisions is causing uncertainty quantification (UQ) to be more routine and often required. UQ provides the underpinnings necessary to establish confidence in models and their use; therefore, much time and effort is being invested in creating efficient approaches for UQ. However, these efforts have been focused on models that take continuous variables as inputs. When discrete inputs are thrown into the mix, the basic approach is to repeat the UQ analysis for each combination of discrete inputs or some subset thereof; this rapidly becomes intractable. Because of the computational complexity inherent in mixed discrete-continuous models, researchers will focus on the uncertainty in their particular problem finding ways to take advantage of symmetries, simplifications or structures. For example, uncertainty propagation in certain dynamical systems can be efficiently carried out after various decomposition steps or uncertainty propagation in stochastic programming is confined to scenario generation. Unfortunately models are not always available for such machinations: models may be embedded in legacy codes, may utilize commercial off the shelf codes or may be created by stringing a series of codes together. It is also time consuming to start each problem from scratch; worse there may not be any simplifications or symmetries to take advantage of. For these situations a UQ method developed for any black box function is necessary. This report documents a new conceptual model for performing UQ for mixed discrete-continuous models which not only applies to any simulator function, but allows the use of the efficient UQ methods that have been developed for continuous inputs only. The conceptual model is presented and an estimation procedure is fleshed out for one class of problems. This is applied to variations of a mixed discrete-continuous optimization test problem. This procedure provides comparable results to a benchmark solution with fewer function evaluations.

Bauman, Lara E.↗

Regulatory Considerations Associated with the Expanded Adoption of Distributed Solar

Increased adoption of distributed PV, and other forms of distributed generation, have the potential to affect utility-customer interactions, system costs recovery, and utility revenue streams. If a greater number of electricity customers choose to self-generate, demand for system power will decrease and utility fixed costs will have to be recovered over fewer kilowatt hours of sales. As such, regulators will need to determine the value and cost of additional distributed PV and determine the appropriate allocation of the costs and benefits among consumers. The potential for new business models to emerge also has implications for regulation and rate structures that ensure equitable solutions for all electricity grid users. This report examines regulatory tools and rate designs for addressing emerging issues with the expanded adoption of distributed PV and evaluates the potential effectiveness and viability of these options going forward. It offers the groundwork needed in order for regulators to explore mechanisms and ensure that utilities can collect sufficient revenues to provide reliable electric service, cover fixed costs, and balance cost equity among ratepayers -- while creating a value proposition for customers to adopt distributed PV.

14 SOLAR ENERGY↗

National Assessment of Energy Storage for Grid Balancing and Arbitrage: Phase 1, WECC

To examine the role that energy storage could play in mitigating the impacts of the stochastic variability of wind generation on regional grid operation, the Pacific Northwest National Laboratory (PNNL) examined a hypothetical 2020 grid scenario in which additional wind generation capacity is built to meet renewable portfolio standard targets in the Western Interconnection. PNNL developed a stochastic model for estimating the balancing requirements using historical wind statistics and forecasting error, a detailed engineering model to analyze the dispatch of energy storage and fast-ramping generation devices for estimating size requirements of energy storage and generation systems for meeting new balancing requirements, and financial models for estimating the life-cycle cost of storage and generation systems in addressing the future balancing requirements for sub-regions in the Western Interconnection. Evaluated technologies include combustion turbines, sodium sulfur (Na-S) batteries, lithium ion batteries, pumped-hydro energy storage, compressed air energy storage, flywheels, redox flow batteries, and demand response. Distinct power and energy capacity requirements were estimated for each technology option, and battery size was optimized to minimize costs. Modeling results indicate that in a future power grid with high-penetration of renewables, the most cost competitive technologies for meeting balancing requirements include Na-S batteries and flywheels.

energy storage↗

Enabling Co-Design of Multi-Layer Exascale Storage Architectures

Growing demands for computing power in applications such as energy production, climate analysis, computational chemistry, and bioinformatics have propelled computing systems toward the exascale: systems with 10 18 floating-point operations per second. These systems, to be designed and constructed over the next decade, will create unprecedented challenges in component counts, power consumption, resource limitations, and system complexity. Data storage and access are an increasingly important and complex component in extreme-scale computing systems, and significant design work is needed to develop successful storage hardware and software architectures at exascale. Co-design of these systems will be necessary to find the best possible design points for exascale systems. The goal of this work has been to enable the exploration and co-design of exascale storage systems by providing a detailed, accurate, and highly parallel simulation of exascale storage and the surrounding environment. Specifically, this simulation has (1) portrayed realistic application checkpointing and analysis workloads, (2) captured the complexity, scale, and multilayer nature of exascale storage hardware and software, and (3) executed in a timeframe that enables “what if'” exploration of design concepts. We developed models of the major hardware and software components in an exascale storage system, as well as the application I/O workloads that drive them. We used our simulation system to investigate critical questions in reliability and concurrency at exascale, helping guide the design of future exascale hardware and software architectures. Additionally, we provided this system to interested vendors and researchers so that others can explore the design space. We validated the capabilities of our simulation environment by configuring the simulation to represent the Argonne Leadership Computing Facility Blue Gene/Q system and comparing simulation results for application I/O patterns to the results of executions of these I/O kernels on the actual system.

97 MATHEMATICS AND COMPUTING↗

Algal Biomass Conversion to Fuels via Combined Algae Processing (CAP): 2019 State of Technology and Future Research

NREL’s algae state of technology benchmarking efforts focus both on front-end algal biomass production and separately on back-end conversion to fuels through NREL’s “combined algae processing” (CAP) pathway. The production model is based on outdoor long-term cultivation data, enabled by comprehensive algal biomass production trials conducted under the Development of Integrated Screening, Cultivar Optimization, and Verification Research consortium (DISCOVR) efforts, driven by data furnished by Arizona State University (ASU) at the Arizona Center for Algae Technology and Innovation (AzCATI) testbed site. The CAP model is based on experimental efforts conducted under NREL research and development projects. This report focuses on back-end conversion of algal biomass through the CAP pathway, highlighting the 2019 updates to minimum fuel selling price (MFSP). This milestone reports on key process sustainability indicators for the CAP conversion stage including mass and carbon yields to fuels and coproducts, freshwater consumption, and facility power balances/natural gas demands.

09 BIOMASS FUELS↗

Security-by-Design: Light Water Small Modular Reactor

The growing demand for nuclear power is increasing pressure to find solutions to cost prohibitive requirements of both construction and security. Offsite response has been proposed as an option to reduce costs associated with training and maintaining an onsite response force. A previous report explored this option and revealed that security could be provided at the required level, but cost savings was not a result of this methodology. An offsite response strategy required costly active and passive delay barriers to provide sufficient time for responders to muster and deploy to a site in time to interrupt a determined and well-equipped adversary. Also, contrary to the hypothesis, the number of responders required for this strategy exceeded that needed for an onsite response force, as the adversaries could avail themselves of advantageous positions within the facility to repel arriving responders. This report builds upon the previous evaluation by using the same hypothetical light water small modular reactor (LWSMR) facility model, but this time an onsite response strategy was assessed. The goal of this analysis was to show that an onsite response strategy could be implemented effectively at a cost point that removes barriers within the industry at this critical time of growth and development. The assessment of the facility design and response strategy was completed through modeling using Scribe3D© and subsequent scenario analysis over the course of a two-day tabletop exercise. Subject matter experts in nuclear security, nuclear facility design, and response strategy and tactics contributed to the effort to ensure accurate representation of hypothetical scenarios. Several adaptations were made to the layout of the LWSMR based on lessons learned during the first day of scenario analysis. The subsequent design evaluated on the second day proved to provide a robust response posture against a large and well-trained adversary force. This report details the process of the analysis and compares the cost of the final facility design with that of the LWSMR model used for evaluation of offsite response. Ultimately, the results of this effort indicate that, when implemented correctly, an onsite response strategy is the best option from a security and cost perspective.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Congestion Management Solutions for Enhanced Distribution System Operations with Aggregated Distribution Grid Resources Providing Grid Services and Market Participation

Microgrids and other aggregations of distribution grid resources (DGRs) are poised to actively participate in electricity markets and provide essential grid services in the coming years. In fact, DGRs already play such a role through behind-the-meter (BTM) demand response programs and small-scale BTM dispatchable generation initiatives. At the same time, the rapid growth of artificial intelligence (AI) and cryptocurrency datacenters imposes significant, often unpredictable, demands on the power distribution system. Aggregated DGRs can serve as flexible resources that help mitigate these pressures by using available transmission and distribution capacity more efficiently, supporting resource adequacy and other reliability services, and providing bridge strategies while long-term transmission infrastructure is being developed. The impacts this activity will have on distribution networks are not fully understood and could present significant challenges for distribution utilities due to capacity constraints and the need for congestion management. Technical issues include reverse power flow, variability and possible degradation of equipment integrity, voltage violations, and customer power quality concerns. These issues will likely intensify as electricity market operators across the United States implement Federal Energy Regulatory Commission Order 2222 over the next few years.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Evaluation program for secondary spacecraft cells: Evaluation of storage methods, open circuit versus continuous trickle charge, Sonotone 3.5 ampere-hour sealed nickel-cadmium secondary spacecraft cells

Twenty-five cells were used in a five-year test to compare, after each successive one-year storage period, the discharge and charge characteristics of charged cells on open circuit versus that of cells on continuous trickle charge. The test procedure, instrumentation, and results are described. Based on the test results, the following recommendations were made: (1) If the user's purpose will allow a rejuvenation cycle or two after a long storage period, the open circuit regime will likely give slightly greater capacity. (2) If the user's purpose demands immediately available power following a long storage period, the trickle charge method of storage is definitely the regime to use.

Thomas, R. E.↗

Photovoltaic refrigeration application: Assessment of the near-term market

This foreign and domestic market assessment was performed as part of the Tests and Applications Project being conducted by NASA-LeRC as part of the Department of Energy's (DOE) National Photovoltaic Program. One of the objectives of that program was to stimulate the demand for photovoltaic power systems so that appropriate markets would be developed in concert with the increasing photovoltaic production capacity. The refrigeration application represented a possible market for photovoltaics; hence, a brief survey of potential applications was conducted. Both refrigerators and refrigeration systems were considered in the assessment although the primary emphasis is on refrigerators of 9 cu ft of less. Three user sectors were examined: (1) government, (2) commercial/institutional, and (3) general public.

Rosenblum, L.↗

Geometric error analysis for shuttle imaging spectrometer experiment

The demand of more powerful tools for remote sensing and management of earth resources steadily increased over the last decade. With the recent advancement of area array detectors, high resolution multichannel imaging spectrometers can be realistically constructed. The error analysis study for the Shuttle Imaging Spectrometer Experiment system is documented for the purpose of providing information for design, tradeoff, and performance prediction. Error sources including the Shuttle attitude determination and control system, instrument pointing and misalignment, disturbances, ephemeris, Earth rotation, etc., were investigated. Geometric error mapping functions were developed, characterized, and illustrated extensively with tables and charts. Selected ground patterns and the corresponding image distortions were generated for direct visual inspection of how the various error sources affect the appearance of the ground object images.

Wang, S. J.↗

Parametric and cycle tests of a 40-A-hr bipolar nickel-hydrogen battery

A series of tests was performed to characterize battery performance relating to certain operating parameters which included charge current, discharge current, temperature and pressure. The parameters were varied to confirm battery design concepts and to determine optimal operating conditions. Spacecraft power requirements are constantly increasing. Special spacecraft such as the Space Station and platforms will require energy storage systems of 130 and 25 kWh, respectively. The complexity of these high power systems will demand high reliability, and reduced mass and volume. A system that uses batteries for storage will require a cell count in excess of 400 units. These cell units must then be assembled into several batteries with over 100 cells in a series connected string. In an attempt to simplify the construction of conventional cells and batteries, the NASA Lewis Research Center battery systems group initiated work on a nickel-hydrogen battery in a bipolar configuration in early 1981. Features of the battery with this bipolar construction show promise in improving both volumetric and gravimetric energy densities as well as thermal management. Bipolar construction allows cooling in closer proximity to the cell components, thus heat removal can be accomplished at a higher rejection temperature than conventional cell designs. Also, higher current densities are achievable because of low cell impedance. Lower cell impedance is achieved via current flow perpendicular to the electrode face, thus reducing voltage drops in the electrode grid and electrode terminals tabs.

Cataldo, R. L.↗

A static data flow simulation study at Ames Research Center

Demands in computational power, particularly in the area of computational fluid dynamics (CFD), led NASA Ames Research Center to study advanced computer architectures. One architecture being studied is the static data flow architecture based on research done by Jack B. Dennis at MIT. To improve understanding of this architecture, a static data flow simulator, written in Pascal, has been implemented for use on a Cray X-MP/48. A matrix multiply and a two-dimensional fast Fourier transform (FFT), two algorithms used in CFD work at Ames, have been run on the simulator. Execution times can vary by a factor of more than 2 depending on the partitioning method used to assign instructions to processing elements. Service time for matching tokens has proved to be a major bottleneck. Loop control and array address calculation overhead can double the execution time. The best sustained MFLOPS rates were less than 50% of the maximum capability of the machine.

Barszcz, Eric↗