Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PATIENTS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

A Multi-Center Controlled Study of the Acute and Chronic Effects of Cooling Therapy for MS

To determine the acute and chronic effects of cooling therapy on patients with MS using objective functional performance measures and self-assessed measures of fatigue. Cooling demyelinated nerves can reduce conduction block, potentially improving symptoms of MS. Significant acute and chronic effects of cooling have not been demonstrated in a multi-center, controlled, blinded study using objective measures of neurologic function. Patients (N=84) with definite MS, mild to moderate disability (EDSS less than 6.0), and self-reported heat sensitivity were enrolled at 5 study sites. Acute effects of cooling were assessed by randomly assigning subjects to high-dose or low-dose cooling for one hour using an active cooling vest and cap (Life Enhancement Technologies, Santa Clara, CA). Settings were individualized to maintain the cooling garments at 55 F for the high-dose treatment and 70 F for the low-dose treatment. Both patients and examining investigators were blinded to treatment assignments. The MSFC and visual acuity/contrast sensitivity were assessed before and 30 minutes after treatment. The following week, subjects had an identical visit with the alternate cooling treatment. Chronic effects of cooling were assessed by randomly assigning the same subjects to unblinded daily home cooling or observation for 4 weeks. All subjects completed the Rochester Fatigue Diary (RFD) twice weekly and subjective measures of strength, cognition, and energy level daily. At the end of the period, subjects completed the Modified Fatigue Impact Scale (MFIS) and underwent another high-dose cooling session with assessment of the MSFC and vision. After a one-week washout period, subjects crossed over to the alternate 4-week treatment. Oral temperatures were reduced with both acute treatments (0.8 +/- .06 F, high and 0.5 +/- .06 F, low). While mean MSFC did not change significantly during individual cooling sessions, post hoc analysis pooling the 3 high-dose cooling sessions revealed an improvement in MSFC scores (acute phase 0.064 +/- 0.020, p = 0.0013; chronic phase 0.044 +/- 0.021, p = 0.0368) from before to after cooling. The change in MSFC scores during the acute cooling sessions was not related to the extent of change in oral temperatures. Both the RFD score and the MFIS indicate a significantly lower fatigue level during the cooling month compared to observation (RFD, 2.53 +/- 0.83,p = 0.0033; MFIS 7.63 +/- 1.56, p = 0.0001).

Luna, Bernadette↗

Portable Hyperbaric Chamber

A portable, collapsible hyperbaric chamber was developed. A toroidal inflatable skeleton provides initial structural support for the chamber, allowing the attendant and/or patient to enter the chamber. Oval hatches mate against bulkhead rings, and the hyperbaric chamber is pressurized. The hatches seal against an o-ring, and the internal pressure of the chamber provides the required pressure against the hatch to maintain an airtight seal. In the preferred embodiment, the hyperbaric chamber has an airlock to allow the attendant to enter and exit the patient chamber during treatment. Visual communication is provided through portholes in the patient and/or airlock chamber. Life monitoring and support systems are in communication with the interior of the hyperbaric chamber and/or airlock chamber through conduits and/or sealed feed-through connectors into the hyperbaric chamber.

Schneider, William C.↗

Balance Evaluation Systems

NeuroCom's Balance Master is a system to assess and then retrain patients with balance and mobility problems and is used in several medical centers. NeuroCom received assistance in research and funding from NASA, and incorporated technology from testing mechanisms for astronauts after shuttle flights. The EquiTest and Balance Master Systems are computerized posturography machines that measure patient responses to movement of a platform on which the subject is standing or sitting, then provide assessments of the patient's postural alignment and stability.

Source record↗

Programmable Pacemaker

St. Jude Medical's Cardiac Rhythm Management Division, formerly known as Pacesetter Systems, Inc., incorporated Apollo technology into the development of the programmable pacemaker system. This consists of the implantable pacemaker together with a physician's console containing the programmer and a data printer. Physician can communicate with patient's pacemaker by means of wireless telemetry signals transmitted through the communicating head held over the patient's chest. Where earlier pacemakers deliver a fixed type of stimulus once implanted, Programalith enables surgery free "fine tuning" of device to best suit the patient's changing needs.

Source record↗

Physiological Feedback Method and System

A method and system provide physiological feedback for a patient and/or physician. At least one physiological effect experienced by a body part of a patient is measured noninvasively. A three-dimensional graphics model serving as an analogous representation of the body part is altered in accordance with the measurements. A binocular image signal representative of the three-dimensional graphics model so-altered is displayed for the patient and/or physician in a virtual reality environment.

Pope, Alan T.↗

Radiation Risk Assessment of the Individual Astronaut: A Complement to Radiation Interests at the NIH

Predicting human risks following exposure to space radiation is uncertain in part because of unpredictable distribution of high-LET and low-dose-derived damage amongst cells in tissues, unknown synergistic effects of microgravity upon gene- and protein-expression, and inadequately modeled processing of radiation-induced damage within cells to produce rare and late-appearing malignant cancers. Furthermore, estimation of risks of radiogenic outcome within small numbers of astronauts is not possible using classic epidemiologic study. It therefore seems useful to develop strategies of risk-assessment based upon large datasets acquired from correlated biological models useful for resolving radiogenic risk-assessment for irradiated individuals. In this regard, it is suggested that sensitive cellular biodosimeters that simultaneously report 1) the quantity of absorbed dose after exposure to ionizing radiation, 2) the quality of radiation delivering that dose, and 3) the biomolecular risk of malignant transformation be developed in order to resolve these NASA-specific challenges. Multiparametric cellular biodosimeters could be developed using analyses of gene-expression and protein-expression whereby large datasets of cellular response to radiation-induced damage are analyzed for markers predictive for acute response as well as cancer-risk. A new paradigm is accordingly addressed wherein genomic and proteomic datasets are registered and interrogated in order to provide statistically significant dose-dependent risk estimation in individual astronauts. This evaluation of the individual for assessment of radiogenic outcomes connects to NIH program in that such a paradigm also supports assignment of a given patient to a specific therapy, the diagnosis of response of that patient to therapy, and the prediction of risks accumulated by that patient during therapy - such as risks incurred by scatter and neutrons produced during high-energy Intensity-Modulated Radiation Therapy. Value of assessment of radiogenic outcome for individuals exposed to radiation is suggested to be common to both NASA and NIH.

Richmond, Robert C.↗

Geometric differences of the mitral apparatus between ischemic and dilated cardiomyopathy with significant mitral regurgitation: real-time three-dimensional echocardiography study

BACKGROUND: This study was conducted to elucidate the geometric differences of the mitral apparatus in patients with significant mitral regurgitation caused by ischemic cardiomyopathy (ICM-MR) and by idiopathic dilated cardiomyopathy (DCM-MR) by use of real-time 3D echocardiography (RT3DE). METHODS AND RESULTS: Twenty-six patients with ICM-MR caused by posterior infarction, 18 patients with DCM-MR, and 8 control subjects were studied. With the 3D software, commissure-commissure plane and 3 perpendicular anteroposterior (AP) planes were generated for imaging the medial, central, and lateral sides of the mitral valve (MV) during mid systole. In 3 AP planes, the angles between the annular plane and each leaflet (anterior, Aalpha; posterior, Palpha) were measured. In ICM-MR, Aalpha measured in the medial and central planes was significantly larger than that in the lateral plane (39+/-5 degrees, 34+/-6 degrees, and 27+/-5 degrees, respectively; P<0.01), whereas Palpha showed no significant difference in any of the 3 AP planes (61+/-7 degrees, 57+/-7 degrees, and 56+/-7 degrees, P>0.05). In DCM-MR, both Aalpha (38+/-8 degrees, 37+/-9 degrees, and 36+/-7 degrees, P>0.05) and Palpha (59+/-6 degrees, 58+/-5 degrees, and 57+/-6 degrees, P>0.05) revealed no significant differences in the 3 planes. CONCLUSIONS: The pattern of MV deformation from the medial to the lateral side was asymmetrical in ICM-MR, whereas it was symmetrical in DCM-MR. RT3DE is a helpful tool for differentiating the geometry of the mitral apparatus between these 2 different types of functional mitral regurgitation.

Evaluation Studies↗

Quantitative analysis of aortic regurgitation: real-time 3-dimensional and 2-dimensional color Doppler echocardiographic method--a clinical and a chronic animal study

BACKGROUND: For evaluating patients with aortic regurgitation (AR), regurgitant volumes, left ventricular (LV) stroke volumes (SV), and absolute LV volumes are valuable indices. AIM: The aim of this study was to validate the combination of real-time 3-dimensional echocardiography (3DE) and semiautomated digital color Doppler cardiac flow measurement (ACM) for quantifying absolute LV volumes, LVSV, and AR volumes using an animal model of chronic AR and to investigate its clinical applicability. METHODS: In 8 sheep, a total of 26 hemodynamic states were obtained pharmacologically 20 weeks after the aortic valve noncoronary (n = 4) or right coronary (n = 4) leaflet was incised to produce AR. Reference standard LVSV and AR volume were determined using the electromagnetic flow method (EM). Simultaneous epicardial real-time 3DE studies were performed to obtain LV end-diastolic volumes (LVEDV), end-systolic volumes (LVESV), and LVSV by subtracting LVESV from LVEDV. Simultaneous ACM was performed to obtain LVSV and transmitral flows; AR volume was calculated by subtracting transmitral flow volume from LVSV. In a total of 19 patients with AR, real-time 3DE and ACM were used to obtain LVSVs and these were compared with each other. RESULTS: A strong relationship was found between LVSV derived from EM and those from the real-time 3DE (r = 0.93, P <.001, mean difference (3D - EM) = -1.0 +/- 9.8 mL). A good relationship between LVSV and AR volumes derived from EM and those by ACM was found (r = 0.88, P <.001). A good relationship between LVSV derived from real-time 3DE and that from ACM was observed (r = 0.73, P <.01, mean difference = 2.5 +/- 7.9 mL). In patients, a good relationship between LVSV obtained by real-time 3DE and ACM was found (r = 0.90, P <.001, mean difference = 0.6 +/- 9.8 mL). CONCLUSION: The combination of ACM and real-time 3DE for quantifying LV volumes, LVSV, and AR volumes was validated by the chronic animal study and was shown to be clinically applicable.

Validation Studies↗

Immunoglobulin Fc gamma receptor promotes immunoglobulin uptake, immunoglobulin-mediated calcium increase, and neurotransmitter release in motor neurons

Receptors for the Fc portion of immunoglobulin G (IgG; FcgammaRs) facilitate IgG uptake by effector cells as well as cellular responses initiated by IgG binding. In earlier studies, we demonstrated that amyotrophic lateral sclerosis (ALS) patient IgG can be taken up by motor neuron terminals and transported retrogradely to the cell body and can alter the function of neuromuscular synapses, such as increasing intracellular calcium and spontaneous transmitter release from motor axon terminals after passive transfer. In the present study, we examined whether FcgammaR-mediated processes can contribute to these effects of ALS patient immunoglobulins. F(ab')(2) fragments (which lack the Fc portion) of ALS patient IgG were not taken up by motor axon terminals and were not retrogradely transported. Furthermore, in a genetically modified mouse lacking the gamma subunit of the FcR, the uptake of whole ALS IgG and its ability to enhance intracellular calcium and acetylcholine release were markedly attenuated. These data suggest that FcgammaRs appear to participate in IgG uptake into motor neurons as well as IgG-mediated increases in intracellular calcium and acetylcholine release from motor axon terminals. Copyright 2002 Wiley-Liss, Inc.

Non-NASA Center↗

New digital measurement methods for left ventricular volume using real-time three-dimensional echocardiography: comparison with electromagnetic flow method and magnetic resonance imaging

AIM: The aim of this study was to investigate the feasibility and accuracy of using symmetrically rotated apical long axis planes for the determination of left ventricular (LV) volumes with real-time three-dimensional echocardiography (3DE). METHODS AND RESULTS: Real-time 3DE was performed in six sheep during 24 haemodynamic conditions with electromagnetic flow measurements (EM), and in 29 patients with magnetic resonance imaging measurements (MRI). LV volumes were calculated by Simpson's rule with five 3DE methods (i.e. apical biplane, four-plane, six-plane, nine-plane (in which the angle between each long axis plane was 90 degrees, 45 degrees, 30 degrees or 20 degrees, respectively) and standard short axis views (SAX)). Real-time 3DE correlated well with EM for LV stroke volumes in animals (r=0.68-0.95) and with MRI for absolute volumes in patients (r-values=0.93-0.98). However, agreement between MRI and apical nine-plane, six-plane, and SAX methods in patients was better than those with apical four-plane and bi-plane methods (mean difference = -15, -18, -13, vs. -31 and -48 ml for end-diastolic volume, respectively, P<0.05). CONCLUSION: Apically rotated measurement methods of real-time 3DE correlated well with reference standards for calculating LV volumes. Balancing accuracy and required time for these LV volume measurements, the apical six-plane method is recommended for clinical use.

Evaluation Studies↗

Changes in autonomic activity preceding onset of nonsustained ventricular tachycardia

Background: The triggering role of the autonomic nervous system in the initiation of ventricular tachycardia has not been established. To investigate the relationship between changes in autonomic activity and the occurrence of nonsustained ventricular tachycardia (NSVT) we examined heart rate variability (HRV) during the 2-hour period preceding spontaneous episodes of NSVT. Twenty-four subjects were identified retrospectively as having had one episode of NSVT during 24-hour Holter ECC recording. Methods: We measured the mean interval between normal heats (meanRR), the standard deviation of the intervals between beats (SD), the percentage of counts of sequential intervals between normal beats with a change of >50 ms (%RR50), the logarithms of low- and high-frequency spectral components (lnLF, lnHF) of HRV for sequential 10-minute segments preceding NSVT. The correlation dimension (CDim) of HRV was calculated similarly for sequential 20-minute segments. We assessed the significance of the time-course change of each marker over the 120-minute period prior to NSVT onset. Results: MeanRR (P < 0.05), lnLF (P < 0.0001), lnHF (P < 0.0001), the natural logarithm of the ratio of LF to HF (ln[LF/HF]; P < 0.05), and CDim (P < 0.05) showed significant time-course changes during that period, while SD and %RR50 did not. MeanRR, lnLF, lnHF, and CDim all decreased prior to the onset of NSVT, whereas ln(LF/HF) increased. We divided the subjects into two groups: one consisting of 12 patients with coronary artery disease; and the second group of 12 patients without known coronary artery disease. Both groups showed significant changes (P < 0.05) of CDim, lnLF, and lnHF preceding the episodes of NSVT. Conclusions: Changes in the pattern of HRV prior to the onset of episodes of NSVT suggest that changes in autonomic activity may commonly play a role in the triggering of spontaneous episodes of NSVT in susceptible patients. The measured changes suggest a reduction in parasympathetic activity, perhaps in conjunction with an increase in sympathetic activity, may trigger NSVT.

Non-NASA Center↗

Sodium sensitive hypertension: renal and adrenal non-modulation in its pathogenesis

The thrust of this essay will be to organize a growing body of evidence which indicates that an abnormality of the kidney, and the adrenal, involving disordered regulation through the renin-angiotensin system, is responsible for the pathogenesis in about 45% of patients--a discrete subgroup that may be most common cause of hypertension. That fundamental abnormality leads to disordered renal sodium handling and sodium-sensitive hypertension, abnormalities in the renal vascular response to changes in sodium intake and to angiotensin II, blunted decrements of renin release in response to saline or angiotensin II, and an accentuated renal vasodilator response to angiotensin converting enzyme (ACE) inhibition. ACE inhibition not only increases renal blood flow substantially more in these patients than it does in normal subjects, ACE inhibition also restores to normal the renal vascular and adrenal response to angiotensin II, renin release in response to angiotensin II, renal sodium handling--and ultimately blood pressure. Finally, and perhaps most intriguing, similar abnormalities have been found in 50% of the normotensive offspring of patients with essential hypertension and evidence is accruing to indicate that the abnormality is inherited as a Mendelian dominant.

Review, Tutorial↗

[Measurement of left atrial and ventricular volumes in real-time 3D echocardiography. Validation by nuclear magnetic resonance]

The measurement of the left ventricular ejection fraction is important for the evaluation of cardiomyopathy and depends on the measurement of left ventricular volumes. There are no existing conventional echocardiographic means of measuring the true left atrial and ventricular volumes without mathematical approximations. The aim of this study was to test anew real time 3-dimensional echocardiographic system of calculating left atrial and ventricular volumes in 40 patients after in vitro validation. The volumes of the left atrium and ventricle acquired from real time 3-D echocardiography in the apical view, were calculated in 7 sections parallel to the surface of the probe and compared with atrial (10 patients) and ventricular (30 patients) volumes calculated by nuclear magnetic resonance with the simpson method and with volumes of water in balloons placed in a cistern. Linear regression analysis showed an excellent correlation between the real volume of water in the balloons and volumes given in real time 3-dimensional echocardiography (y = 0.94x + 5.5, r = 0.99, p < 0.001, D = -10 +/- 4.5 ml). A good correlation was observed between real time 3-dimensional echocardiography and nuclear magnetic resonance for the measurement of left atrial and ventricular volumes (y = 0.95x - 10, r = 0.91, p < 0.001, D = -14.8 +/- 19.5 ml and y = 0.87x + 10, r = 0.98, P < 0.001, D = -8.3 +/- 18.7 ml, respectively. The authors conclude that real time three-dimensional echocardiography allows accurate measurement of left heart volumes underlying the clinical potential of this new 3-D method.

Non-NASA Center↗

The neuropathic postural tachycardia syndrome

BACKGROUND: The postural tachycardia syndrome is a common disorder that is characterized by chronic orthostatic symptoms and a dramatic increase in heart rate on standing, but that does not involve orthostatic hypotension. Several lines of evidence indicate that this disorder may result from sympathetic denervation of the legs. METHODS: We measured norepinephrine spillover (the rate of entry of norepinephrine into the venous circulation) in the arms and legs both before and in response to exposure to three stimuli (the cold pressor test, sodium nitroprusside infusion, and tyramine infusion) in 10 patients with the postural tachycardia syndrome and in 8 age- and sex-matched normal subjects. RESULTS: At base line, the mean (+/-SD) plasma norepinephrine concentration in the femoral vein was lower in the patients with the postural tachycardia syndrome than in the normal subjects (135+/-30 vs. 215+/-55 pg per milliliter [0.80+/-0.18 vs. 1.27+/-0.32 nmol per liter], P=0.001). Norepinephrine spillover in the arms increased to a similar extent in the two groups in response to each of the three stimuli, but the increases in the legs were smaller in the patients with the postural tachycardia syndrome than in the normal subjects (0.001+/-0.09 vs. 0.12+/-0.12 ng per minute per deciliter of tissue [0.006+/-0.53 vs. 0.71+/-0.71 nmol per minute per deciliter] with the cold pressor test, P=0.02; 0.02+/-0.07 vs. 0.23+/-0.17 ng per minute per deciliter [0.12+/-0.41 vs. 1.36+/-1.00 nmol per minute per deciliter] with nitroprusside infusion, P=0.01; and 0.008+/-0.09 vs. 0.19+/-0.25 ng per minute per deciliter [0.05+/-0.53 vs. 1.12+/-1.47 nmol per minute per deciliter] with tyramine infusion, P=0.04). CONCLUSIONS: The neuropathic postural tachycardia syndrome results from partial sympathetic denervation, especially in the legs.

NASA Discipline Regulatory Physiology↗

Treatment of hypertension with perindopril reduces plasma atrial natriuretic peptide levels, left ventricular mass, and improves echocardiographic parameters of diastolic function

BACKGROUND: Hypertension is a major independent risk factor for cardiac deaths, and diastolic dysfunction is a usual finding during the course of this disease. HYPOTHESIS: This study was designed to investigate the effects of chronic therapy with perindopril on left ventricular (LV) mass, left atrial size, diastolic function, and plasma level of atrial natriuretic peptide (ANP) in patients with hypertension. METHODS: Twenty four patients who had not been previously taking any antihypertensive medication and without prior history of angina pectoris, myocardial infarction, congestive heart failure, dysrhythmias, valvular heart disease, or systemic illnesses received 4-8 mg/day of perindopril orally. Echocardiographic studies were acquired at baseline and 6 months after the initiation of therapy. RESULTS: Systolic and diastolic blood pressure decreased from 174 +/- 19.7 and 107.5 +/- 7.8 mmHg to 134 +/- 10.6 and 82 +/- 6.7 mmHg, respectively (p < 0.001). Left ventricular mass decreased from 252.4 +/- 8.3 to 205.7 +/- 7.08 g and left atrial volume from 20.4 +/- 5.1 to 17.6 +/- 5.2 ml, respectively (p < 0.001). Transmitral Doppler early and atrial filling velocity ratio (E/A) increased from 0.69 +/- 0.06 to 0.92 +/- 0.05 m/s and plasma ANP level decreased from 71.9 +/- 11.7 to 35.3 +/- 7.8 pg/ml (p < 0.001). Reduction of LV mass correlated positively with a reduction in ANP levels (r = 0.66, p < 0.0005). CONCLUSIONS: Perindopril caused a significant reduction of LV mass, left atrial volume, and plasma ANP levels, as well as improvement in Doppler parameters of LV filling in this group of patients with hypertension.

NASA Program Biomedical Research and Countermeasur↗

Interaction of genetic predisposition and environmental factors in the pathogenesis of idiopathic orthostatic intolerance

BACKGROUND: The hemodynamic and autonomic abnormalities in idiopathic orthostatic intolerance (IOI) have been studied extensively. However, the mechanisms underlying these abnormalities are not understood. If genetic predisposition were important in the pathogenesis of IOI, monozygotic twins of patients with IOI should have similar hemodynamic and autonomic abnormalities. METHODS: We studied two patients with IOI and their identical twins. Both siblings in the first twin pair had orthostatic symptoms, significant orthostatic tachycardia, increased plasma norepinephrine levels with standing, and a greater than normal decrease in systolic blood pressure with trimethaphan infusion. RESULTS: Both siblings had a normal response of plasma renin activity to upright posture. In the second twin pair, only one sibling had symptoms of orthostatic intolerance, an orthostatic tachycardia, and raised plasma catecholamines with standing. The affected sibling had inappropriately low plasma renin activity with standing and was 8-fold more sensitive to the pressor effect of phenylephrine than the unaffected sibling. CONCLUSIONS: We conclude that in some patients, IOI seems to be strongly influenced by genetic factors. In others, however, IOI may be mainly caused by nongenetic factors. These findings suggest that IOI is heterogenous, and that both genetic and environmental factors contribute individually or collectively to create the IOI phenotype.

NASA Discipline Regulatory Physiology↗

Neocytolysis contributes to the anemia of renal disease

Neocytolysis is a recently described physiological process affecting the selective hemolysis of young red blood cells in circumstances of plethora. Erythropoietin (EPO) depression appears to initiate the process, providing the rationale to investigate its contributions to the anemia of renal disease. When EPO therapy was withheld, four of five stable hemodialysis patients showed chromium 51 (51Cr)-red cell survival patterns indicative of neocytolysis; red cell survival was short in the first 9 days, then normalized. Two of these four patients received oral 13C-glycine and 15N-glycine, and there was a suggestion of pathological isotope enrichment of stool porphyrins when EPO therapy was held, again supporting selective hemolysis of newly released red cells that take up the isotope (one patient had chronic hemolysis indicated by isotope studies of blood and stool). Thus, neocytolysis can contribute to the anemia of renal disease and explain some unresolved issues about such anemia. One implication is the prediction that intravenous bolus EPO therapy is metabolically and economically inefficient compared with lower doses administered more frequently subcutaneously.

Non-NASA Center↗

Prognostic significance of electrical alternans versus signal averaged electrocardiography in predicting the outcome of electrophysiological testing and arrhythmia-free survival

OBJECTIVE: To investigate the accuracy of signal averaged electrocardiography (SAECG) and measurement of microvolt level T wave alternans as predictors of susceptibility to ventricular arrhythmias. DESIGN: Analysis of new data from a previously published prospective investigation. SETTING: Electrophysiology laboratory of a major referral hospital. PATIENTS AND INTERVENTIONS: 43 patients, not on class I or class III antiarrhythmic drug treatment, undergoing invasive electrophysiological testing had SAECG and T wave alternans measurements. The SAECG was considered positive in the presence of one (SAECG-I) or two (SAECG-II) of three standard criteria. T wave alternans was considered positive if the alternans ratio exceeded 3.0. MAIN OUTCOME MEASURES: Inducibility of sustained ventricular tachycardia or fibrillation during electrophysiological testing, and 20 month arrhythmia-free survival. RESULTS: The accuracy of T wave alternans in predicting the outcome of electrophysiological testing was 84% (p < 0.0001). Neither SAECG-I (accuracy 60%; p < 0.29) nor SAECG-II (accuracy 71%; p < 0.10) was a statistically significant predictor of electrophysiological testing. SAECG, T wave alternans, electrophysiological testing, and follow up data were available in 36 patients while not on class I or III antiarrhythmic agents. The accuracy of T wave alternans in predicting the outcome of arrhythmia-free survival was 86% (p < 0.030). Neither SAECG-I (accuracy 65%; p < 0.21) nor SAECG-II (accuracy 71%; p < 0.48) was a statistically significant predictor of arrhythmia-free survival. CONCLUSIONS: T wave alternans was a highly significant predictor of the outcome of electrophysiological testing and arrhythmia-free survival, while SAECG was not a statistically significant predictor. Although these results need to be confirmed in prospective clinical studies, they suggest that T wave alternans may serve as a non-invasive probe for screening high risk populations for malignant ventricular arrhythmias.

Non-NASA Center↗