Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Optics and Optical Instruments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

“Development and application of analytical detection techniques for droplet-based microfluidics”-A review

Droplet-based microfluidics has emerged as a powerful platform for high-throughput and low-volume analysis and screening. At present, droplet-based microfluidics is transitioning from the proof-of-concept stage to real-world applications. During this process, analytical detection techniques play indispensable roles for successfully implementing droplet-based chemical or biological assays. Here, we provide an overview of recent developments in analytical techniques for droplet analysis and elucidate the advantages and limitations of each technique. We cover the majority of technology categories, including optical detection, electrical detection, mass spectrometry, and nuclear magnetic resonance spectroscopy. Additionally, we highlight new research areas that have been enabled by these technical advances. Finally, we provide perspectives on both future technological directions and potential enabling applications.

47 OTHER INSTRUMENTATION↗

A realistic guide misalignment model for the Second Target Station instruments at the Spallation Neutron Source

The Second Target Station (STS) at the Spallation Neutron Source, including a suite of initial instrument concepts, are being designed in Oak Ridge. The moderator size at STS is significantly smaller than that of the First Target Station, making the guide misalignment a more prominent concern. Here a realistic misalignment model based on Monte Carlo neutron ray tracing simulation was developed to evaluate the impacts of both the random misalignment and floor settlement on the performance of a toy model of 150 m straight guide system, and MENUS, an STS instrument concept with a typical guide design of two opposing Montel mirrors. The study shows that longer instruments, and instruments with complex curved mirrors/guides are sensitive to significant performance penalties due to misalignments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multicolor multifocal 3D microscopy using in-situ optimization of a spatial light modulator

Abstract Multifocal microscopy enables high-speed three-dimensional (3D) volume imaging by using a multifocal grating in the emission path. This grating is typically designed to afford a uniform illumination of multifocal subimages for a single emission wavelength. Using the same grating for multicolor imaging results in non-uniform subimage intensities in emission wavelengths for which the grating is not designed. This has restricted multifocal microscopy applications for samples having multicolored fluorophores. In this paper, we present a multicolor multifocal microscope implementation which uses a Spatial Light Modulator (SLM) as a single multifocal grating to realize near-uniform multifocal subimage intensities across multiple wavelength emission bands. Using real-time control of an in-situ-optimized SLM implemented as a multifocal grating, we demonstrate multicolor multifocal 3D imaging over three emission bands by imaging multicolored particles as well as Escherichia coli ( E. coli ) interacting with human liver cancer cells, at $$\sim 2.5$$ ∼ 2.5 multicolor 3D volumes per second acquisition speed. Our multicolor multifocal method is adaptable across SLM hardware, emission wavelength band locations and number of emission bands, making it particularly suited for researchers investigating fast processes occurring across a volume where multiple species are involved.

47 OTHER INSTRUMENTATION↗

Measurement of laser absorption in underdense plasmas using near-field imaging of the incident and transmitted beams

Measurements of laser absorption in high-temperature, underdense plasmas produced at the Omega Laser Facility are made using two near-field imaging detectors that diagnose the spatial profile and energy of the port P9 beam before and after it transmits through the plasma. The incident beam is sampled using a partial reflection from a full-aperture, (30 cm-diam) uncoated wedge pickoff located before the target chamber vacuum window and final focus lens assembly. A concave mirror reduces the reflected beam size, allowing it to be recorded directly using a charged-coupled device (CCD) camera. The P9 transmitted beam diagnostic (P9TBD) characterizes the transmitted light by terminating the expanded beam on a semi-transparent diffuser and imaging the illuminated surface using a lens and CCD camera. The P9TBD samples a numerical aperture twice as large as the input beam, allowing the energy of transmitted beams with moderate levels of beam spray to be measured accurately. Calibration shots with no plasma provide a path to infer absorption without absolute photometric calibration of either detector. Lastly, the cross-calibration between the two detectors was measured to remain stable at ±200 ppm, enabling measurements of total beam absorption below 1% with ±0.07% error.

47 OTHER INSTRUMENTATION↗

Implementing Faraday effect measurement constraints into the Grad–Shafranov equilibrium fitting code EFIT

A new tool for the exploration and diagnosis of the internal magnetic field of plasmas in the DIII-D tokamak in the form of a constraint on the EFIT (Equilibrium Fitting) Grad–Shafranov code based on the Faraday-effect Radial Interferometer-Polarimeter (RIP) diagnostic is presented, including description, verification, and sample application. The physics underlying the diagnostic and its implementation into EFIT are discussed, and the results showing the verification of the model are given, and the model’s limitations are discussed. The influence of the diagnostic’s input on the resulting equilibrium parameters is characterized. Furthermore, the effect of electron density profile refinement is evaluated and found to be negligible. A sample application of the diagnostic is shown, indicating that the RIP constraint has similar effects on the equilibrium as motional Stark effect constraints do.

47 OTHER INSTRUMENTATION↗

High-magnification Faraday rotation imaging and analysis of X-pinch implosion dynamics

An X-pinch load driven by an intense current pulse (>100 kA in ~100 ns) can result in the formation of a small radius, runaway compressional micro-pinch. A micro-pinch is characterized by a hot (>1 keV), current-driven (>100 kA), high-density plasma column (near solid density) with a small neck diameter (1–10 µm), a short axial extent (<1 mm), and a short duration (≲1 ns). With material pressures often well into the multi-Mbar regime, a micro-pinch plasma often radiates an intense, sub-ns burst of sub-keV to multi-keV x rays. A low-density coronal plasma immediately surrounding the dense plasma neck could potentially shunt current away from the neck and thus reduce the magnetic drive pressure applied to the neck. Here, to study the current distribution in the coronal plasma, a Faraday rotation imaging diagnostic (1064 nm) capable of producing simultaneous high-magnification polarimetric and interferometric images has been developed for the MAIZE facility at the University of Michigan. Designed with a variable magnification (1–10×), this diagnostic achieves a spatial resolution of ~35 µm, which is useful for resolving the ~100-μm-scale coronal plasma immediately surrounding the dense core. This system has now been used on a reduced-output MAIZE (100–200 kA, 150 ns) to assess the radial distribution of drive current immediately surrounding the dense micro-pinch neck. The total current enclosed was found to increase as a function of radius, r, from a value of ≈ 50 ± 25 kA at r ≈ 140 µm (at the edge of the dense neck) to a maximal value of ≈150 ± 75 kA for r ≥ 225 µm. This corresponds to a peak magnetic drive pressure of ≈75 ± 50 kbar at r ≈ 225 µm. The limitations of these measurements are discussed in the paper.

47 OTHER INSTRUMENTATION↗

The rate of extreme coronal line emitting galaxies in the Sloan Digital Sky Survey and their relation to tidal disruption events

High-ionization iron coronal lines (CLs) are a rare phenomenon observed in galaxy and quasi-stellar object spectra that are thought to be created by high-energy emission from active galactic nuclei and certain types of transients. In cases known as extreme coronal line emitting galaxies (ECLEs), these CLs are strong and fade away on a time-scale of years. The most likely progenitors of these variable CLs are tidal disruption events (TDEs), which produce sufficient high-energy emission to create and sustain the CLs over these time-scales. To test the possible connection between ECLEs and TDEs, we present the most complete variable ECLE rate calculation to date and compare the results to TDE rates from the literature. To achieve this, we search for ECLEs in the Sloan Digital Sky Survey (SDSS). We detect sufficiently strong CLs in 16 galaxies, more than doubling the number previously found in SDSS. Using follow-up spectra from the Dark Energy Spectroscopic Instrument and Gemini Multi-Object Spectrograph, Wide-field Infrared Survey Explorer mid-infrared observations, and Liverpool Telescope optical photometry, we find that none of the nine new ECLEs evolve in a manner consistent with that of the five previously discovered variable ECLEs. Using this sample of five variable ECLEs, we calculate the galaxy-normalized rate of variable ECLEs in SDSS to be $R_\mathrm{G}=3.6~^{+2.6}_{-1.8}~(\mathrm{statistical})~^{+5.1}_{-0.0}~(\mathrm{systematic})\times 10^{-6}~\mathrm{galaxy}^{-1}~\mathrm{yr}^{-1}$. The mass-normalized rate is $R_\mathrm{M}=3.1~^{+2.3}_{-1.5}~(\mathrm{statistical})~^{+4.4}_{-0.0}~(\mathrm{systematic})\times 10^{-17}~\mathrm{M_\odot ^{-1}}~\mathrm{yr}^{-1}$ and the volumetric rate is $R_\mathrm{V}=7~^{+20}_{-5}~(\mathrm{statistical})~^{+10}_{-0.0}~(\mathrm{systematic})\times 10^{-9}~\mathrm{Mpc}^{-3}~\mathrm{yr}^{-1}$. Our rates are one to two orders of magnitude lower than TDE rates from the literature, which suggests that only 10–40 per cent of all TDEs produce variable ECLEs. Additional uncertainties in the rates arising from the structure of the interstellar medium have yet to be included.

79 ASTRONOMY AND ASTROPHYSICS↗

Dark Energy Survey Year 6 results: cell-based coadds and METADETECTION weak lensing shape catalogue

We present the metadetection weak lensing galaxy shape catalogue from the 6-yr Dark Energy Survey (DES Y6) imaging data. This data set is the final release from DES, spanning 4422 deg 2 of the southern sky. We describe how the catalogue was constructed, including the two new major processing steps, cell-based image coaddition, and shear measurements with metadetection. The DES Y6 M etadetection weak lensing shape catalogue consists of 151 922 791 galaxies detected over riz bands, with an effective number density of n eff = 8.22 galaxies per arcmin 2 and shape noise of σ e = 0.29. We carry out a suite of validation tests on the catalogue, including testing for point spread function (PSF) leakage, testing for the impact of PSF modelling errors, and testing the correlation of the shear measurements with galaxy, PSF, and survey properties. In addition to demonstrating that our catalogue is robust for weak lensing science, we use the DES Y6 image simulation suite to estimate the overall multiplicative shear bias of our shear measurement pipeline. We find no detectable multiplicative bias at the roughly half-per cent level, with m = (3.4 ± 6.1) x 10 –3 , at 3σ uncertainty. This is the first time both cell-based coaddition and Metadetection algorithms are applied to observational data, paving the way to the Stage-IV weak lensing surveys.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Topological Singularity Induced Chiral Kohn Anomaly in a Weyl Semimetal

The electron-phonon interaction (EPI) is instrumental in a wide variety of phenomena in solid-state physics, such as electrical resistivity in metals, carrier mobility, optical transition, and polaron effects in semiconductors, lifetime of hot carriers, transition temperature in BCS superconductors, and even spin relaxation in diamond nitrogen-vacancy centers for quantum information processing. However, due to the weak EPI strength, most phenomena have focused on electronic properties rather than on phonon properties. One prominent exception is the Kohn anomaly, where phonon softening can emerge when the phonon wave vector nests the Fermi surface of metals. In this paper, we report a new class of Kohn anomaly in a topological Weyl semimetal (WSM), predicted by field-theoretical calculations, and experimentally observed through inelastic x-ray and neutron scattering on WSM tantalum phosphide. Compared to the conventional Kohn anomaly, the Fermi surface in a WSM exhibits multiple topological singularities of Weyl nodes, leading to a distinct nesting condition with chiral selection, a power-law divergence, and non-negligible dynamical effects. Our work brings the concept of the Kohn anomaly into WSMs and sheds light on elucidating the EPI mechanism in emergent topological materials.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Integrated multi-wavelength microscope combining TIRFM and IRM modalities for imaging cellulases and other processive enzymes

We describe a multimodal microscope for visualizing processive enzymes moving on immobilized substrates. The instrument combines interference reflection microscopy (IRM) with multi-wavelength total internal reflectance fluorescence microscopy (TIRFM). The microscope can localize quantum dots with a precision of 2.8 nm at 100 frames/s, and was used to image the dynamics of the cellulase, Cel7a interacting with surface-immobilized cellulose. The instrument, which was built with off-the-shelf components and is controlled by custom software, is suitable for tracking other degradative enzymes such as collagenases, as well as motor proteins moving along immobilized tracks.

09 BIOMASS FUELS↗

Quasi-Distributed Fiber Sensor-Based Approach for Pipeline Health Monitoring: Generating and Analyzing Physics-Based Simulation Datasets for Classification

This study presents a framework for detecting mechanical damage in pipelines, focusing on generating simulated data and sampling to emulate distributed acoustic sensing (DAS) system responses. The workflow transforms simulated ultrasonic guided wave (UGW) responses into DAS or quasi-DAS system responses to create a physically robust dataset for pipeline event classification, including welds, clips, and corrosion defects. This investigation examines the effects of sensing systems and noise on classification performance, emphasizing the importance of selecting the appropriate sensing system for a specific application. The framework shows the robustness of different sensor number deployments to experimentally relevant noise levels, demonstrating its applicability in real-world scenarios where noise is present. Overall, this study contributes to the development of a more reliable and effective method for detecting mechanical damage to pipelines by emphasizing the generation and utilization of simulated DAS system responses for pipeline classification efforts. The results on the effects of sensing systems and noise on classification performance further enhance the robustness and reliability of the framework.

36 MATERIALS SCIENCE↗

Ice nucleating particle concentrations measured by the CSU-CFDC during the AGINSGP field experiment

Real-time, immersion mode ambient ice nucleating particle (INP) concentrations were measured at ARM&rsquo;s Southern Great Plains (SGP) site during the AGINSGP field experiment using a continuous flow diffusion chamber (CFDC) from Colorado State University (CSU). The CSU-CFDC is an ice-thermal gradient diffusion chamber that optically detects the freezing of single aerosol particles (Rogers 1988; Rogers et al. 2001; and Eidhammer et al. 2010). The instrument was located in the guest instrument facility (GIF) and measured INP concentrations from April 8th to April 29th. Air was drawn into the GIF through custom aluminum stack inlets (6&rdquo; inner diameter) attached vertically to the outer GIF wall and the GIF outside platform. A blower pulled air through the stacks at a velocity of 1 m/s. Aerosol instruments subsampled via wall ports, through either 3/8&rdquo; or 1/4" copper lines, depending on sample flow of the instrument. Rogers, D. C., Development of a continuous flow thermal gradient diffusion chamber for ice nucleation studies, Atmospheric Research, 22(2), 149-181, doi:10.1016/0169-8095(88)90005-1, 1988. Rogers, D. C., P. J. DeMott, S. M. Kreidenweis and Y. Chen, A continuous flow diffusion chamber for airborne measurements of ice nuclei, J. Atmos. Oceanic Technol., 18, 725-741, doi:10.1175/1520-0426(2001)018<0725:ACFDCF>2.0.CO;2, 2001. Eidhammer, T., DeMott, P. J., Prenni, A. J., Petters, M. D., Twohy, C. H., Rogers, D. C., Stith, J., Heymsfield, A., Wang, Z., Haimov, S., French, J., Pratt, K., Prather, K., Murphy, S., Seinfeld, J., Subramanian, R., and Kreidenweis, S. M., Ice initiation by aerosol particles: Measured and predicted ice nuclei concentrations versus measured ice crystal concentrations in an orographic wave cloud, J. Atmos. Sci., 67, 2417-2436, doi:10.1175/2010JAS3266.1, 2010

54 ENVIRONMENTAL SCIENCES↗

ARM Aerial Facility (AAF) Water-based Condensation Particle Counter

The condensation particle counter (CPC) measures sub-micron aerosol particle number concentration by condensing fluid onto particles and causing them to grow to sizes that are easily detectable by optical scattering. The condensing liquid is typically an alcohol (e.g., butanol) or water. Depending on the CPC type, typical CPC instruments can count particles with sizes that range from 3 to 3000 nanometers (ultrafine CPC) or from 10 to 3000 nanometers (fine CPC).

54 ENVIRONMENTAL SCIENCES↗

Post maximum light and late time optical imaging polarimetry of type I superluminous supernova 2020znr

ABSTRACT Optical imaging polarimetry was conducted on the hydrogen poor superluminous supernova 2020znr during three phases after maximum light (≈ +34 d, +288 d, and +289 d). After instrumental and interstellar polarization correction, all measurements are consistent with null-polarization detection. Modelling the light curve with a magnetar spin-down model shows that SN2020znr has similar magnetar and ejecta parameters to other SLSNe. A comparison of the best-fitting values discussed in the literature on SN 2017egm and SN 2015bn, two hydrogen poor SLSNe showing an increase of polarization after maximum light, suggests that SN 2020znr has higher mass ejecta that may prevent access to the geometry of the inner ejecta with optical polarimetry. The combined information provided by spectroscopy and light-curve analysis of type I SLSNe may be an interesting avenue to categorize the polarization properties of this class of transients. This approach would require to expand the sample of SLSNe polarimetry data currently available with early and late time epochs new measurements.

2015bn↗

Calibration and characterization of the line-VISAR diagnostic at the HED-HIBEF instrument at the European XFEL

In dynamic-compression experiments, the line-imaging Velocity Interferometer System for Any Reflector (VISAR) is a well-established diagnostic used to probe the velocity history, including wave profiles derived from dynamically compressed interfaces and wavefronts, depending on material optical properties. Knowledge of the velocity history allows for the determination of the pressure achieved during compression. Such a VISAR analysis is often based on Fourier transform techniques and assumes that the recorded interferograms are free from image distortions. In this paper, we describe the VISAR diagnostic installed at the HED-HIBEF instrument located at the European XFEL along with its calibration and characterization. It comprises a two-color (532, 1064 nm), three-arm (with three velocity sensitivities) line imaging system. We provide a procedure to correct VISAR images for geometric distortions and evaluate the performance of the system using Fourier analysis. We finally discuss the spatial and temporal calibrations of the diagnostic. As an example, we compare the pressure extracted from the VISAR analysis of shock-compressed polyimide and silicon.

47 OTHER INSTRUMENTATION↗

The Hubble Space Telescope PanCET Program: An Optical to Infrared Transmission Spectrum of HAT-P-32Ab

We present a 0.3−5 μm transmission spectrum of the hot Jupiter HAT-P-32Ab observed with the Space Telescope Imaging Spectrograph and Wide Field Camera 3 instruments mounted on the Hubble Space Telescope, combined with Spitzer Infrared Array Camera photometry. The spectrum is composed of 51 spectrophotometric bins with widths ranging between 150 and 400 Å, measured to a median precision of 215 ppm. Comparisons of the observed transmission spectrum to a grid of 1D radiative-convective equilibrium models indicate the presence of clouds/hazes, consistent with previous transit observations and secondary eclipse measurements. To provide more robust constraints on the planet’s atmospheric properties, we perform the first full optical to infrared retrieval analysis for this planet. The retrieved spectrum is consistent with a limb temperature of 1248{sub −92}{sup +92} K, a thick cloud deck, enhanced Rayleigh scattering, and ∼10× solar H{sub 2}O abundance. We find log(Z/Z {sub ⊙}) = 2.41{sub −0.07}{sup +0.06}, and compare this measurement with the mass–metallicity relation derived for the solar system.

79 ASTRONOMY AND ASTROPHYSICS↗

Frequency comb generation in WGM microsphere based generators for telecommunication applications

We review the frequency comb generation process, main microresonator parameters such as free spectral range (FSR) and Q-factor, previously used optical frequency comb (OFC) generator parameters and resulting frequency combs, as well as the implementation of OFC for optical data transmission. An optical frequency comb is produced in a setup based on a tapered fibre and a SiO{sub 2} microsphere. The generated frequency comb has a frequency spacing of 2 nm or 257 GHz. During the fabrication of a tapered fibre from SMF28, use is made of the transmission signal to control the taper pulling process. The final measured tapered fibre transmission is ∼96%. A microsphere whispering gallery-mode resonator (WGMR), exhibiting a Q-factor of at least 2 × 10{sup 7}, is fabricated from an optical fibre with a thicker core than SSMF. Moreover, for future experiments, a frequency comb generator based on a free-space setup consisting of lenses, a prism, and a microsphere is developed, and the Q-factor dependence on different distances between the prism and the microsphere is investigated. (optical components of fibre-optic communication lines)

36 MATERIALS SCIENCE↗