Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “NEUTRON SPECTRA”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

SUPERNOVA NEUTRINO LIGHT CURVES AND SPECTRA FOR VARIOUS PROGENITOR STARS: FROM CORE COLLAPSE TO PROTO-NEUTRON STAR COOLING

We present a new series of supernova neutrino light curves and spectra calculated by numerical simulations for a variety of progenitor stellar masses (13-50 M {sub Sun }) and metallicities (Z = 0.02 and 0.004), which would be useful for a broad range of supernova neutrino studies, e.g., simulations of future neutrino burst detection by underground detectors or theoretical predictions for the relic supernova neutrino background. To follow the evolution from the onset of collapse to 20 s after the core bounce, we combine the results of neutrino-radiation hydrodynamic simulations for the early phase and quasi-static evolutionary calculations of neutrino diffusion for the late phase, with different values of shock revival time as a parameter that should depend on the still unknown explosion mechanism. We describe the calculation methods and basic results, including the dependence on progenitor models and the shock revival time. The neutrino data are publicly available electronically.

79 ASTRONOMY AND ASTROPHYSICS↗

How to Produce a Reactor Neutron Spectrum Using a Proton Accelerator

A method for reproducing the neutron energy spectrum present in the core of an operating nuclear reactor using an engineered target in an accelerator proton beam is proposed. The protons interact with a target to create neutrons through various (p,n) type reactions. Spectral tailoring of the emitted neutrons can be used to modify the energy of the generated neutron spectrum to represent various reactor spectra. Through the use of moderators and reflectors, the neutron spectrum can be modified to reproduce many different spectra of interest including spectra in small thermal test reactors, large pressurized water reactors, and fast reactors. The particular application of this methodology is the design of an experimental approach for using an accelerator to measure the betas produced during fission to be used to reduce uncertainties in the interpretation of reactor antineutrino measurements. This approach involves using a proton accelerator to produce a neutron field representative of a power reactor, and using this neutron field to irradiate fission foils of the primary isotopes contributing to fission in the reactor, creating unstable, neutron rich fission products that subsequently beta decay and emit electron antineutrinos. A major advantage of an accelerator neutron source over a neutron beam from a thermal reactor is that the fast neutrons can be slowed down or tailored to approximate various power reactor spectra. An accelerator based neutron source that can be tailored to match various reactor neutron spectra provides an advantage for control in studying how changes in the neutron spectra affect parameters such as the resulting fission product beta spectrum.

43 PARTICLE ACCELERATORS↗

Dual Gamma Neutron Directional Elpasolite Detector

Some applications, particularly in homeland security, require detection of both neutron and gamma radiation. Typically, this is accomplished with a combination of two detectors registering neutrons and gammas separately. We have investigated a new type of neutron/gamma (n/γ) directional detection capability. We explored a new class of scintillator, cerium (Ce)-doped Elpasolites such as Cs2LiYCl6:Ce (CLYC), Cs2LiLaCl6 (CLLC), Cs2LiLaBr6:Ce (CLLB), or Cs2LiYBr6:Ce (CLYB). These materials are capable of providing energy resolution as good as 2.9% at 662 keV (FWHM), which is better than that of NaI:Tl. Because they contain 6Li, Elpasolites can also detect thermal neutrons. In the energy spectra, the full energy thermal neutron peak appears near or above 3 GEEn MeV. Thus, very effective pulse height discrimination is possible. In addition, the core-to-valence luminescence (CVL) provides Elpasolites with different temporal responses under gamma and neutron excitation, and, therefore, may be exploited for effective pulse shape discrimination. For instance, the CLLC emission consists of two main components: (1) CVL spanning from 220 nm to 320 nm and (2) Ce emission found in the range of 350 to 500 nm. The former emission is of particular interest because it appears only under gamma excitation. It is also very fast, decaying with a 2 ns time constant. The n/γ discrimination capability of Elpasolite detectors may be optimized by tuning the cerium doping content for maximum effect on n/γ pulse shape differences. The resulting Elpasolite detectors have the ability to collect neutron and gamma data simultaneously, with excellent discrimination. Further, an array of four of these Elpasolites detectors will perform directional detection in both the neutron and gamma channels simultaneously.

radiation detectors, neutron detectors, scintillat↗

Scintillation Properties of a Cs2LiLa(Br6)90%(Cl6)10%:Ce (CLLBC) Crystal

In investigations of Ce3+-doped Cs2LiLa(Br6)90%(Cl6)10% (CLLBC) elpasolite crystals, the crystals show an excellent neutron and gamma (n/g) radiation response. The results of our studies on the scintillation properties of CLLBC viz. radioluminescence, energy resolution, light yield, decay times, and nonproportionality are discussed. The CLLBC detector can provide energy resolution as good as 4.1% at 662 keV (FWHM), which is better than that of NaI:Tl. Because the crystal contains 6Li, CLLBC can also detect thermal neutrons. In the energy spectra, the full energy thermal neutron peak appears near or above 3 MeV gamma equivalent energy. This high-energy signature for the thermal neutron peak means that very effective pulse height discrimination is possible. Unfortunately, because the core-to-valence luminescence observed in other elpasolites that can be exploited for effective pulse shape discrimination (PSD) is not observed in the CLLBC, other strategies for obtaining the PSD of CLLBC are needed. The n/g discrimination capability of CLLBC detectors may be optimized by tuning the cerium doping content for maximum effect on n/g pulse shape differences. The value of adding a chlorine component to the nominal CLLB crystal is discussed. Because the crystal contains chlorine, its sensitivity to fast neutrons is better than that of Cs2LiLaBr6 (CLLB). Further, an array of three of these CLLBC detectors may be able to perform directional detection in both the neutron and gamma channels simultaneously.

36 MATERIALS SCIENCE↗

MCNP Simulation of Discrete Gamma-ray Spectra for PGNAA Applications

Prompt Gamma Neutron Activation (PGNAA) systems use the neutron-induced gamma-ray spectra from test objects in order to identify their compositions. The U.S. Army in particular uses these systems to identify the contents of field-recovered munitions in order to determine the presence of chemical warfare materiel (CWM) or explosives. These field-recovered munitions can have a variety of different fills, including experimental fills, have a large range of sizes, and be assessed in different field conditions. All these variations can have a significant effect on the neutron-induced gamma-ray spectrum and therefore a large impact on automatic fill identification algorithms. In order to develop robust identification algorithms, parametric studies of the effects of munition size, fill composition, and assessment conditions are very useful but time-consuming and expensive in the laboratory. Monte Carlo modeling of the system response to these variations is a very attractive alternative, provided the modeling accurately reflects real gamma spectra and can be performed quickly and inexpensively when compared to experiment. At Idaho National Laboratory we have used the Monte Carlo N-Particle (MCNP6) code [2] to calculate the response of the Portable Isotopic Neutron Spectroscopy (PINS) system to a number of simulated chemical warfare munitions as well as performed laboratory measurements with the system. Two versions of PINS system were used; one excited the test object with neutrons from a 252C f source and one with neutrons from a portable deuterium-deuterium (DD) neutron generator. The sets of measurements and simulations with the two different neutron sources provided experimental data for development of automatic fill identification algorithms as well as providing a good test of the agreement between the MCNP calculations and experiment.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Beta-delayed gamma spectra compilation and analysis following the thermal-neutron induced fission of 235 U, 239,241 Pu

The integral gamma and electron spectra emitted by fission products, also known as delayed gamma and electron spectra, were measured at Oak Ridge National Laboratory in the 1970s for the thermal-neutron induced fission of 235 U and 239,241 Pu. Scintillator detectors were used to measure these spectra, data used later on to obtain decay heat values - that is, the spectra mean values per unit time as function of time - work that was published in the Nuclear Science and Technology journal; the spectral data, however, was only published in laboratory reports. Here, in this work, we analyze the gamma spectra data using modern methods and nuclear databases to reveal the signature of individual fission products as well as to gauge the performance of the ENDF/B-VIII.0 decay data sub-library, concluding about possible future enhancements in predictive capabilities.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

ELECTROMAGNETIC EMISSION FROM LONG-LIVED BINARY NEUTRON STAR MERGER REMNANTS. II. LIGHT CURVES AND SPECTRA

Recent observations indicate that in a large fraction of binary neutron star (BNS) mergers a long-lived neutron star (NS) may be formed rather than a black hole. Unambiguous electromagnetic (EM) signatures of such a scenario would strongly impact our knowledge on how short gamma-ray bursts (SGRBs) and their afterglow radiation are generated. Furthermore, such EM signals would have profound implications for multimessenger astronomy with joint EM and gravitational-wave (GW) observations of BNS mergers, which will soon become reality thanks to the ground-based advanced LIGO/Virgo GW detector network. Here we explore such EM signatures based on the model presented in a companion paper, which provides a self-consistent evolution of the post-merger system and its EM emission up to ∼10{sup 7} s. Light curves and spectra are computed for a wide range of post-merger physical properties. We present X-ray afterglow light curves corresponding to the “standard” and the “time-reversal” scenario for SGRBs (prompt emission associated with the merger or with the collapse of the long-lived NS). The light curve morphologies include single and two-plateau features with timescales and luminosities that are in good agreement with Swift observations. Furthermore, we compute the X-ray signal that should precede the SGRB in the time-reversal scenario, the detection of which would represent smoking-gun evidence for this scenario. Finally, we find a bright, highly isotropic EM transient peaking in the X-ray band at ∼10{sup 2}–10{sup 4} s after the BNS merger with luminosities of L{sub X} ∼ 10{sup 46}–10{sup 48} erg s{sup −1}. This signal represents a very promising EM counterpart to the GW emission from BNS mergers.

79 ASTRONOMY AND ASTROPHYSICS↗

Materials characterisation with the associated particle technique

Since the last past years, the Nuclear Measurement Laboratory of CEA Cadarache, France, together with Partners from European and National projects, has been studying the application of fast neutron interrogation with the Associated Particle Technique for material identification in different areas of homeland and maritime security, and for the characterisation of the materials constituting radioactive waste. Fast 14 MeV neutrons are produced from the H-3(H-2,n)alpha fusion reaction in a sealed tube neutron generator embedding an alpha detector. The alpha particle is used to tag neutron direction and emission time, thus allowing the electronic selection of neutron-induced gamma spectra in the voxels of interest. Gamma rays emitted by tagged neutron interactions on the present nuclei (C, O, N, Fe, Al, Si, Cl, etc.) are recorded with spectroscopic detectors and analysed to determine elemental proportions, thus allowing material identification. Investigations have been conducted for the detection of explosives, illicit drugs and contraband materials in cargo containers, for the inspection of objects lying on the sea floor suspected to contain explosives like mines, bombs, torpedoes, etc., for the recognition of an improvised chemical device, and for material identification in radioactive waste packages. Recently the detection of special nuclear materials is being investigated using time correlation analysis between induced fission particles, instead of gamma-ray spectroscopy. The paper presents an overview of these studies and last results. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Diamond neutral particle spectrometer for fusion reactor ITER

A compact diamond neutral particle spectrometer with digital signal processing has been developed for fast charge-exchange atoms and neutrons measurements at ITER fusion reactor conditions. This spectrometer will play supplementary role for Neutral Particle Analyzer providing 10 ms time and 30 keV energy resolutions for fast particle spectra in non-tritium ITER phase. These data will also be implemented for independent studies of fast ions distribution function evolution in various plasma scenarios with the formation of a single fraction of high-energy ions. In tritium ITER phase the DNPS will measure 14 MeV neutrons spectra. The spectrometer with digital signal processing can operate at peak counting rates reaching a value of 10{sup 6} cps. Diamond neutral particle spectrometer is applicable to future fusion reactors due to its high radiation hardness, fast response and high energy resolution.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

SOURCES4D

SOURCES is a code for computing neutron source rates and spectra from spontaneous fission (including delayed neutrons) and (alpha,n) reactions in homogeneous materials and (alpha,n) reactions in single-interface and two-interface geometries. SOURCES is a Los Alamos National Laboratory (LANL) code that is written in FORTRAN and distributed through the Radiation Safety Information Computation Center (RSICC). LANL’s last release of SOURCES to RSICC was SOURCES4C in 2002. This disclosure covers the latest version of SOURCES, SOURCES4D. This version adds sensitivity capabilities for (alpha,n) sources in homogeneous materials. Specifically, SOURCES4D writes new output that can be used to calculate, in post-processing, first and second derivatives of the (alpha,n) source rate density and spectrum with respect to nuclide densities in a homogeneous material and first derivatives of the (alpha,n) source rate density and spectrum with respect to nuclide stopping powers and (alpha,n) cross sections (nuclear data). These derivatives are useful for uncertainty quantification, predictive modeling, and other applications in neutron transport problems.

Favorite, Jeffrey A.↗

Estimating the AmLi Neutron Spectrum from Measured Ring Ratios

These are a set of slides on estimating the AmLi neutron spectrum from measured ring ratios. The IAEA uses an AmLi source in the Uranium Neutron Coincidence Collar (UNCL) to verify compliance with nonproliferation treaties. The UNCL requires calibration with known uranium samples. The AmLi spectrum isn’t known well enough to allow simulated calibrations. Alphas lose energy traveling through AmO 2 particle of unknown size. Energy reduction below Li threshold enhances O contribution. Unknown Li matrix material affects neutron production and thermalization. There is large variation in spectra from each element. Other topics covered include: applications, physics considerations, current spectra, measurement overview, measurement results - variation between sources, simulations, spectra fitting, other simulations, and conclusions.

07 ISOTOPE AND RADIATION SOURCES↗

(U) Release of SOURCES4D Featuring Sensitivity Capabilities

SOURCES is a code for computing neutron source rates and spectra from spontaneous fission (including delayed neutrons) and (α,n) reactions. The first release since 2002, SOURCES4D, is now available. The main updates include new output that allows the user to calculate, in post-processing, first and second derivatives of the (α,n) source rate density and spectrum with respect to nuclide densities in a homogeneous material and first derivatives of the (α,n) source rate density and spectrum with respect to nuclide stopping powers and (α,n) cross sections (nuclear data). The value of π was made more accurate in order to eliminate negative spontaneous-fission sources. Otherwise, SOURCES4D has made no changes to the physics or data of neutron source calculations used in SOURCES4C. First and second derivatives are calculated in an example problem.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Statistical neutron capture in the limit of low nuclear level density

A major barrier in the study of neutron-induced nuclear reactions is the impossibility of direct measurements with short-lived radioactive isotopes. For these exotic nuclei, theoretical inputs such as the Photon Strength Function (PSF) are poorly constrained. At Los Alamos National Laboratory, the Detector for Advanced Neutron Capture Experiments (DANCE) provides direct measurements of γ-ray cascades following neutron capture reactions on stable or long-lived radioactive nuclei. While Hauser-Feshbach calculations can provide reasonable predictions for neutron capture on heavy nuclei, their application to neutron-rich light nuclei with low nuclear level densities and low neutron separation energies is questionable. In this paper, we report on the γ-ray spectra from individual neutron resonances from the 96 Zr(n, γ) reaction, with an emphasis on the sensitivity of of the γ-ray spectra to different PSF models. The comparison of the measured γ-ray spectra with predicted spectra does not support the addition of a low-energy enhancement of the size reported in many charged-particle reaction measurements, but the sensitivity of the γ-ray spectra to different PSF models is weak.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Neutron-Gamma flux and Dose calculations in a Pressurized Water Reactor (PWR)

The Institute of Radiological Protection and Nuclear Safety (IRSN) acts as technical support to the French nuclear safety authorities. In this context, one of its missions is to improve nuclear safety through the enhancement of knowledge regarding operating nuclear power reactors. The issues concerning the aging and the characterisation of the reactor vessel require knowledge of the neutron and gamma radiation environment on the vessel and beyond. Since few years, ENEA (Energia Nucleare e Energie Alternative, i.e. Nuclear Energy and Alternative Energy agency) and IRSN collaborate on Monte-Carlo simulations and Variance Reduction Techniques (VRT), which are used to determine neutron and gamma spectra in and out of the core. Additionally, IRSN participates in the DISCOMS project, which stands for 'Distributed Sensing for Corium Monitoring and Safety', aiming at examining the status of the third barrier of confinement, in order to define possible mitigation strategies in case of a severe accident, namely: i) reactor pressure vessel breakthrough and corium relocation outside the vessel, ii) reactor pit concrete erosion and iii) corium cooling. One of the IRSN tasks in the frame of the DISCOMS project is to provide the radiation level in terms of neutron and gamma doses and flux energy spectra at various locations. This paper summarizes the study performed on the radiation transport in the Tihange-I Belgian nuclear reactor and contributes to several issues requiring the knowledge of the radiation environment in and outside the reactor vessel. This paper gives an overview of the work presented at the ICRS-13 and RPSD-2016 conference (for more details see the proceedings paper)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

SU-D-BRE-07: Neutron Shielding Assessment for a Compact Proton Therapy Vault

Purpose: To perform a neutron shielding assessment of a commercially available compact proton therapy system. Methods: TOPAS (TOol for PArticle Simulation) beta release was used to model beam line components for Mevion S250 proton treatment system the design of which is that the cyclotron is present in the treatment room. Three neutron production sources were taken into account in the simulation. These are the cyclotron, the treatment nozzle and the patient itself, respectively. The cyclotron was modeled as a cylindrical iron target (r =5 cm, length = 8 cm). A water phantom (10 cm ×10 cm ×60 cm) was used to model the patient and various structures (scattering foils, range modulator wheel, applicator and compensator) defaulted in TOPAS were used to model the passive scattering treatment nozzle. Neutron fluences and energy spectra were counted in a spherical scoring geometry per incident proton in 18 angular bins (10 degree each). Fluence to dose conversion factors from ICRU publication 74 were used to acquire neutron ambient dose equivalent H*(10). A point source line of sight model was then used to calculate neutron dose at eight locations beyond shielding barriers. Results: The neutron ambient dose equivalent was calculated at the 8 points of interest around the proton treatment vault. The highest dose was found to be less than 0.781 mSv/year outside south barrier wall. However, the dose is less than 0.05 mSv/year at the control room area of the proton vault. Conclusion: All Points of interest were well under annual dose limits. This suggests that the shielding design of this compact proton therapy system is sufficient for radiation protection purpose. However, it is important to note that the workload and the occupancy factors are direct multipliers for dose calculations beyond the barrier and must be accurately estimated for validation of our results.

07 ISOTOPE AND RADIATION SOURCES↗