Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Membrane systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

Self-assembled nanofiltration membranes with thermo- and pH-responsive behavior

We produce controlled nanostructured membranes from cross-linking of self-assembled diacrylated poloxamers. At sufficiently high concentrations, poloxamers form lyotropic liquid crystals (LLCs), such as lamellar (L α ), cubic packing of spherical micelles, and hexagonal packing of rod-like micelles in water (H 1 ). We use the H 1 phase as a template to produce orderly packed nanofibrous membranes. The obtained membrane has a continuous 3D transport pathway and can alter its nanofiltration (NF) properties in response to changes in temperature and pH. The formulation includes Pluronic P84-diacrylate (P84DA), a thermoresponsive component that acts as both macromer and structure-directing amphiphile. P84DA facilitates changes in membrane pore size with temperature due to its thermoresponsiveness when it is in contact with water. Furthermore, the precursor contains acrylic acid (AAc) as the charged component, which upon copolymerization with P84DA, not only enables ion separation through Donnan exclusion but also imparts pH-responsive behavior for the separation of ionic species. The membrane performance is studied and compared with a commercial NF membrane (NF270). We show that the synthesized NF membrane has separation properties adjustable with temperature and pH with exceptional resistance to fouling by various solutes due to its highly hydrophilic surface. Furthermore, the membrane shows an outstanding sulfate over chloride ion selectivity, which is a requirement for salt fractionation applications. Deducted from separate experiments, the ideal chloride/sulfate selectivity for magnesium cation is about 2.38 at low ionic strengths. This study is done on a model system to show the capability of incorporating pH-responsiveness in LLC templated membranes, in which the pH-responsive range can be designed by changing the charged groups of comonomer in the formulation.

36 MATERIALS SCIENCE↗

Next Generation Life Support Project Status

Next Generation Life Support (NGLS) is one of several technology development projects sponsored by NASA s Game Changing Development Program. The NGLS Project is developing life support technologies (including water recovery and space suit life support technologies) needed for humans to live and work productively in space. NGLS has three project tasks: Variable Oxygen Regulator (VOR), Rapid Cycle Amine (RCA) swing bed, and Alternative Water Processor (AWP). The RCA swing bed and VOR tasks are directed at key technology needs for the Portable Life Support System (PLSS) for an Advanced Extravehicular Mobility Unit, with focus on test article development and integrated testing in an Advanced PLSS in cooperation with the Advanced Extra Vehicular Activity (EVA) Project. An RCA swing-bed provides integrated carbon dioxide removal and humidity control that can be regenerated in real time during an EVA. The VOR technology will significantly increase the number of pressure settings available to the space suit. Current space suit pressure regulators are limited to only two settings whereas the adjustability of the advanced regulator will be nearly continuous. The AWP effort, based on natural biological processes and membrane-based secondary treatment, will result in the development of a system capable of recycling wastewater from sources expected in future exploration missions, including hygiene and laundry water. This paper will provide a status of technology development activities and future plans.

Barta, Daniel J.↗

Impact of reactor architecture and design parameters on the performance of microbial electrolysis cells revealed by the electrode potential slope analysis

Microbial electrolysis cells (MECs) are appealing for recovering the chemical energy contained in domestic and industrial liquid wastes as hydrogen gas. Despite several years of research in the field, there is still a lack of critical analysis of how the reactor architecture dictates the electrochemical performance of the cell. In this study, internal resistance and onset voltage from the electrode potential slope analysis (EPS) were used in combination with current density, hydrogen production rate, reactor packing density, electrode spacing, membrane type and composition from 23 different studies to identify the reactor design parameters that primarily govern electrochemical performance of MECs. Using anion exchange membranes resulted in smaller internal resistances (AEM R int = 41± 40 mΩ m 2 ) and larger current density (18 ± 14 A m −2 ) compared to single chamber reactors (SC R int = 68 ± 58 mΩ m 2 ; 22 ± 16 A m −2 ) or MECs with cation exchange membranes (CEM R int = 376 ± 280 mΩ m 2 ; 3.0 ± 2.1 A m −2 ). Higher electrochemical performance for AEM- and SC-MECs translated in larger hydrogen gas production rates (0.122 mL H 2 C −1 for AEM vs 0.117 mL H 2 C −1 for SC), but only when inhibitors against hydrogen scavengers were added in single chamber systems (0.080 mL H 2 C −1 for SC without inhibitors). Following membrane type and composition, maintaining a small electrode spacing was the most critical parameter to improve MEC performance, indicating that the low conductivity of the media primarily limit performance by increasing ohmic resistance. Here, reactor volume and electrode surface area negatively correlated with internal resistance and current density, indicating that better performance of scaled-up reactors can likely be obtained by stacking multiple smaller units rather than just increasing reactor size. Although challenges remain in the implementation of MECs for hydrogen production from liquid wastes, advances in electrochemical engineering of the reactors can facilitate scale up and performance prediction at scale.

Electrochemistry↗

The Impact of Catalyst Layer Composition and Structure on Performance and Durability of PEMWE Anodes

A study of various compositions of anodes for proton exchange membrane water electrolysis aimed at reducing precious metal content and system costs without compromising performance and durability is presented. A key challenge in current water electrolysis technologies is the reliance on high iridium loadings to ensure sufficient catalytic activity, electronic conductivity, and durability for the oxygen evolution reaction. To address this, catalyst layers based on the stable but kinetically limited rutile phase of iridium oxide are combined with platinum nanoparticles and carbon-based additives to improve structural properties and ink processability. By systematically varying the volume ratios of carbon to precious metals and ionomer to solids, compositional trends have been identified, and significant performance improvements have been achieved. Structural and elemental analysis confirms improved dispersion of platinum and iridium can be achieved, as well as electronic conductivity improvements within the catalyst layer. Polarization curve analysis has shown the ability of added Pt and C to significantly increase catalytic activity. These results highlight the potential positive impact of Pt and C on anode structure, composition, and cell performance.

36 MATERIALS SCIENCE↗

Antineoplastic activity of Salmonella Typhimurium outer membrane nanovesicles

Highlights: • ST-OMVs is a promising antitumor monotherapy or as an adjuvant to chemotherapies. • ST-OMVs downregulated Ki-67 and upregulated CD49b immune-expression. • ST-OMVs downregulated angiogenesis by inhibiting VEGF gene expression. • ST-OMVs increased tumor cells apoptosis and autophagy (increased caspase-3and Beclin1). Nano-sized Gram-negative bacterial outer membrane vesicles possess unique structural and immunostimulatory effects that could be exploited to regress tumors by alerting the host immune system and reversing the immunosuppressive tumor microenvironment. The current study was conducted to investigate the antitumor activity of the outer membrane vesicles (ST-OMVs) of Salmonella Typhimurium ATCC 14028, in vitro in human colorectal carcinoma (HTC116), breast cancer (MCF-7), and hepatocellular carcinoma (HepG2) cell lines and in vivo in Ehrlich solid carcinoma-bearing mice model either as a mono-immunotherapy or as an adjuvant to a commonly used conventional chemotherapy. In addition, we investigated the safety of ST-OMVs. Adult Swiss albino female mice with transplanted Ehrlich solid carcinoma were treated with either ST-OMVs, paclitaxel or a combination of both. Tumor volume, growth inhibition rate, quantitative RT-PCR of Bax and VEGF genes expression, histopathology and immune-expression of caspase-3, Beclin-1, CD49b and Ki-67 were all analyzed. Our results showed that ST-OMVs significantly decreased tumor volume, significantly increased tumor growth inhibition rate, up-regulated the immunohistochemical expression of caspase-3, Beclin-1, and CD49b (enhanced recruitment of NK cells). Furthermore, ST-OMVs down-regulated the expression of Ki-67, increased Bax gene expression and decreased VEGF gene expression as detected by qRT-PCR analysis. Histologically, ST-OMVs promoted apoptosis, decreased tumor invasion and mitotic activities. Moreover, ST-OMVs showed a remarkable cytotoxic activity in various investigated in vitro cancer cell lines. Our findings demonstrate potential antitumor activity of ST-OMVs that might be used as a promising safe antitumor immunotherapy or an adjuvant to conventional chemotherapeutic drugs, resolving some of their problems.

60 APPLIED LIFE SCIENCES↗

Heterogeneous Supramolecular Catalysis through Immobilization of Anionic M 4 L 6 Assemblies on Cationic Polymers

Although most of the currently developed supramolecular catalysts that emulate enzymatic reactivity with unique selectivity and activity through specific host-guest interactions work under homogeneous conditions, enzymes in nature can operate under heterogeneous conditions as membrane-bound enzymes. In order to develop such a heterogeneous system, an immobilized chiral supramolecular cluster Ga 4 1 6 ( 2 ) was introduced into cross-linked polymers with cationic functionalities. These heterogeneous supramolecular catalysts were used in aza-Prins and aza-Cope reactions and successfully applied to continuous-flow reactions. Additionally, they showed high durability and maintained high turnovers for long periods of time. In sharp contrast to the majority of examples of heterogenized homogeneous catalysts, the newly developed catalysts showed enhanced activity and robustness compared to those exhibited by the corresponding soluble cluster catalyst. An enantioenriched cluster was also immobilized to enable asymmetric catalysis, and activity and enantioselectivity of the supported chiral catalyst were maintained during recovery and reuse experiments and under a continuous-flow process. Significantly, the structure of the ammonium cations in the polymers affected stability, reactivity, and enantioselectivity, which is consistent with the hypothesis that the cationic moieties in the polymer support interact with cluster as an exohedral protecting shell, thereby influencing their catalytic performance.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Dynamics of amphiphilic PEG–PDMS–PEG triblock copolymer assemblies

Here, the size and stability of micelles and vesicles determine the uptake capacity of guest molecules, thereby influencing potential applications in drug/gene delivery, bioreactors, and templates for nanoparticle synthesis. Polyethylene glycol (PEG) and polydimethylsiloxane (PDMS) are commonly used in these applications. We discovered that PEG-PDMS-PEG triblock copolymers can assemble into micelles and vesicles, making them valuable for dynamic studies to derive the bending elasticity, $κ_η$, which governs the stability these objects. We analyzed the structure using cryogenic transmission electron microscopy and small-angle neutron scattering. We investigated the dynamics through dynamic light scattering and neutron spin echo spectroscopy. By varying the number of repeating units in the hydrophilic block, we created micellar (PEG 28 -PDMS 15 -PEG 28 ) and vesicular systems (PEG 14 -PDMS 15 -PEG 14 ). For the vesicle, membrane rigidity was determined from experiments to be $κ_η$ =(16 ± 2) $k_BT$, where $k_BT$ is the thermal energy ($k_B$ Boltzmann’s constant and T is the temperature). According to Zilman and Granek's concept, membrane rigidity reflects height-height fluctuations within the membrane layer. Compared to polymers at the oil-water interface of a microemulsion, the membrane rigidity in polymersomes is over an order of magnitude higher, indicating significantly enhanced stability. This value closely aligns with that of liposomes, suggesting similar stability between polymersomes and liposomes.

Gupta, Sudipta [Louisiana State Univ., Baton Rouge↗

Hydrogen Energy: Production and Utilization for a Green Economy [Slides]

The scope of the presentation includes: 1. Introduce high-level aspects of hydrogen fuel systems; and, 2. Showcase research addressing relevant challenges: Proton exchange membrane fuel cells (PEMFCs) (Subzero temperature applications and AFM characterization of catalyst layers); and, Non-precious-metal hydrogen evolution catalysts).

08 HYDROGEN↗

Positively charged membrane for urea dialysis

Positively charged, porous membrane dividing two chamber dialysis machine allows urease decomposition within system while preventing return flow of ammonium ions to patient.

Mueller, W. A.↗

Determination of Electromagnetic Properties of Mesh Material Using Advanced Radiometer Techniques

The need for a large diameter deployable antenna to map soil moisture with a 10 kilometer or better resolution using a microwave radiometer is discussed. A 6 meter deployable antenna is also needed to map sea surface temperature on the Navy Remote Ocean Sensor System (NROSS). Both of these deployable antennas require a mesh membrane material as the reflecting surface. The determination of the electromagnetic properties of mesh materials is a difficult problem. The Antenna and Microwave Research Branch (AMRB) of Langley Research Center was asked to measure the material to be used on MROSS by NRL. A cooperative program was initiated to measure this mesh material using two advanced radiometer techniques.

Arrington, R. F.↗

Measurement of electrostatically formed antennas using photogrammetry and theodolites

An antenna concept is presently being evaluated which has extremely low mass and high surface precision for potential depolyment from the Space Shuttle. This antenna concept derives its reflector surface quality from the application of electrostatic forces to tension and form a thin membrane into the desired concave reflector surface. The Shuttle-deployed antenna would have a diameter of 100 meters and an RMS surface smoothness of 10 to 1 mm for operation at 1 to 10 GHz. NASA Langley Research Center (LaRC) has built, and is currently testing, a subscale (1/20 scale) membrane reflector model of such an antenna. Several surface measurement systems were evaluated as part of the experimental surface measuring efforts. The surface measurement systems are addressed as well as some of the preliminary measurement results.

Goslee, J. W.↗

An Improved Design for Air Removal from Aerospace Fluid Loop Coolant Systems

Aerospace applications with requirements for large capacity heat removal (launch vehicles, platforms, payloads, etc.) typically utilize a liquid coolant fluid as a transport media to increase efficiency and flexibility in the vehicle design. An issue with these systems however, is susceptibility to the presence of noncondensable gas (NCG) or air. The presence of air in a coolant loop can have numerous negative consequences, including loss of centrifugal pump prime, interference with sensor readings, inhibition of heat transfer, and coolant blockage to remote systems. Hardware ground processing to remove this air is also cumbersome and time consuming which continuously drives recurring costs. Current systems for maintaining the system free of air are tailored and have demonstrated only moderate success. An obvious solution to these problems is the development and advancement of a passive gas removal device, or gas trap, that would be installed in the flight cooling system simplifying the initial coolant fill procedure and also maintaining the system during operations. The proposed device would utilize commercially available membranes thus increasing reliability and reducing cost while also addressing both current and anticipated applications. In addition, it maintains current pressure drop, water loss, and size restrictions while increasing tolerance for pressure increases due to gas build-up in the trap.

Ritchie, Stephen M. C.↗

Compound gravity receptor polarization vectors evidenced by linear vestibular evoked potentials

The utricle and saccule are gravity receptor organs of the vestibular system. These receptors rely on a high-density otoconial membrane to detect linear acceleration and the position of the cranium relative to Earth's gravitational vector. The linear vestibular evoked potential (VsEP) has been shown to be an effective non-invasive functional test specifically for otoconial gravity receptors (Jones et al., 1999). Moreover, there is some evidence that the VsEP can be used to independently test utricular and saccular function (Taylor et al., 1997; Jones et al., 1998). Here we characterize compound macular polarization vectors for the utricle and saccule in hatchling chickens. Pulsed linear acceleration stimuli were presented in two axes, the dorsoventral (DV, +/- Z axis) to isolate the saccule, and the interaural (IA, +/- Y axis) to isolate the utricle. Traditional signal averaging was used to resolve responses recorded from the surface of the skull. Latency and amplitude of eighth nerve components of the linear VsEP were measured. Gravity receptor responses exhibited clear preferences for one stimulus direction in each axis. With respect to each utricular macula, lateral translation in the IA axis produced maximum ipsilateral response amplitudes with substantially greater amplitude intensity (AI) slopes than medially directed movement. Downward caudal motions in the DV axis produced substantially larger response amplitudes and AI slopes. The results show that the macula lagena does not contribute to the VsEP compound polarization vectors of the sacculus and utricle. The findings suggest further that preferred compound vectors for the utricle depend on the pars externa (i.e. lateral hair cell field) whereas for the saccule they depend on pars interna (i.e. superior hair cell fields). These data provide evidence that maculae saccule and utricle can be selectively evaluated using the linear VsEP.

NASA Discipline Developmental Biology↗

Durable Suit Bladder with Improved Water Permeability for Pressure and Environment Suits

Water vapor permeability is shown to be useful in rejecting heat and managing moisture accumulation in launch-and-entry pressure suits. Currently this is accomplished through a porous Gortex layer in the Advanced Crew and Escape Suit (ACES) and in the baseline design of the Constellation Suit System Element (CSSE) Suit 1. Non-porous dense monolithic membranes (DMM) that are available offer potential improvements for water vapor permeability with reduced gas leak. Accordingly, three different pressure bladder materials were investigated for water vapor permeability and oxygen leak: ElasthaneTM 80A (thermoplastic polyether urethane) provided from stock polymer material and two custom thermoplastic polyether urethanes. Water vapor, carbon dioxide and oxygen permeability of the DMM's was measured in a 0.13 mm thick stand-alone layer, a 0.08 mm and 0.05 mm thick layer each bonded to two different nylon and polyester woven reinforcing materials. Additional water vapor permeability and mechanical compression measurements were made with the reinforced 0.05 mm thick layers, further bonded with a polyester wicking and overlaid with moistened polyester fleece thermal underwear .This simulated the pressure from a supine crew person. The 0.05 mm thick nylon reinforced sample with polyester wicking layer was further mechanically tested for wear and abrasion. Concepts for incorporating these materials in launch/entry and Extravehicular Activity pressure suits are presented.

Bue, Grant C.↗

Fuel Cell Research and Development for Future NASA Missions

NASA has been using fuel cell systems since the early days of space flight. Polymer Exchange Membrane Fuel cells provided the primary power for the Gemini and Apollo missions and more recently, alkaline fuel cells serve as the primary power source for the Space Shuttle. NASA's current investments in fuel cell technology support both Exploration and Aeronautics programs. This presentation provides an overview of NASA's fuel cell development programs.

Manzo, Michelle A.↗

Brane Craft

A Brane Craft is a membrane spacecraft with solar cells, command and control electronics, communications systems, antennas, propulsion systems, attitude and proximity sensors, and shape control actuators as thin film structures manufactured on 10 micron thick plastic sheets. This revolutionary spacecraft design can have a thickness of tens of microns with a surface area of square meters to maximize area-to-mass ratios for exceptionally low-mass spacecraft. Communications satellites, solar power satellites, solar electric propulsion stages, and solar sails can benefit from Brane Craft design. It also enables new missions that require low-mass spacecraft with exceptionally high delta-V. Active removal of orbital debris from Earth orbit is the target application for this study.

thrusters↗

Stabilization of a co-bound intermediate via molecular tuning promotes CO2-to-ethylene conversion

Aspects included herein include an electrolytic system for electrochemical reduction of carbon dioxide, the system comprising: a cathode comprising: a porous gas-diffusion membrane permeable to CO 2 ; an electrocatalyst layer adjacent to a second side of the gas-diffusion membrane; the electrocatalyst layer comprising: an electrically conductive catalyst; and a selectivity-determining organic material attached to at least a portion of the electrically conductive catalyst; wherein: the organic material is formed of a plurality of oligomers; each oligomer comprises a plurality of covalently bonded base units; each base unit comprises at least one heterocyclic group having at least one nitrogen in its structure; and an anion exchange membrane adjacent to the electrocatalyst layer and positioned between the anode and the cathode; wherein anion exchange membrane is characterized by anion conductivity and the cathode is in ionic communication with the anode via the anion exchange membrane.

Agapie, Theodor↗