Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MONITORING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

Gamma-Ray Imaging to Monitor Accumulating Holdup

Over time, nuclear materials can accumulate in process equipment and keeping track of such material is of interest to many stakeholder communities including safeguards, process monitoring, criticality safety, and radiological safety. Passive gamma-ray imaging provides a visual and quantitative tool that can be applied to this problem, allowing one to determine the amount of material present from the images. In this work we emulate the accumulation of highly enriched uranium (HEU) in a large rectangular stainless-steel duct by stacking 5, 27 × 50 cm2 cards, each of which has approximately 11 g of 235U in oxide form distributed across its surface, behind each other. A series of images were collected using a coded-aperture gamma-ray imager, starting with a single card, adding a second card, etc. Long integrations were collected to allow evaluating the performance of the approach as a function of integration time. The images are analyzed using first principles to determine the amount of material in each image. The results are compared to the known amount of material in each configuration, and as a function of time. The analysis includes a first-principles error propagation and to further evaluate the uncertainty, a boot-strap sampling approach is also applied to the data. The work offers a proof of concept for unattended monitoring of uranium holdup with a quantitative gamma-ray imaging technique.

Ziock, Klaus-Peter↗

Non-invasive, in situ diagnosis and monitoring of corrosion in high temperature systems

Techniques for non-invasive diagnosis and/or monitoring of corrosion in high temperature systems using specialized sensors that produce multi-mode acoustic signals in situ for accurate determination of wall loss and/or physical property changes for a vessel in contact with a high temperature, highly corrosive substance are disclosed. Sensitivity of a few microns (or about 0.1%) of wall loss, detection of changes in physical properties of vessel contents (e.g., approximately 1%), or both, at temperatures of 500° C., 600° C., or higher may be realized. Corrosion may be identified and/or monitored using time domain, frequency domain, or mixed time domain and frequency domain analysis of signal characteristics, signal delay, or both, for relatively short circumferential acoustic wave propagation (e.g., a few inches), as well as relatively long axial acoustic wave propagation (e.g., tens of feet).

Findikoglu, Alp Tugrul↗

Optical device for in-line and real-time monitoring of microorganisms

A multi-wavelength laser diode based optical sensor system capable of monitoring the dynamics and physiological changes of a microorganism culture in real-time. The microorganism culture from a microorganism production chamber is pumped to a flow chamber. Laser diodes emit light at certain wavelengths through the flow chamber, which is sensed by photodiodes. A laser control circuitry is operatively connected to the laser diodes and a signal conditioning circuitry is operatively connected to the photodiodes. A microprocessor reads and records voltage signals corresponding to the wavelengths. A data acquisition system converts said voltage signals into measurements of biological parameters, which are displayed on a graphical user interface and allow a user to monitor the measurements in real time.

47 OTHER INSTRUMENTATION↗

Wearable health monitoring device

A wearable patient device is provided that includes one or more sensors. The one or more sensors can record one or both of ECG information or phonocardiographic information. The sensor information can be used to determine the blood pressure of a monitored individual, including on a continuous basis. Blood pressure can be determined using one or both of a determined time to empty or fill one or more heart chambers or first and second blood velocities. Vital sign information can be provided to a monitoring individual, including graphical representations of trend information.

Gosink, Luke J.↗

Scalable auditability of monitoring process using public ledgers

Secure auditability of monitoring processing using public ledgers that are particularly useful for monitoring surveillance orders, whereby an overseeing enforcer (“E”) checks if law enforcement agencies and companies are respectively over-requesting or over-sharing user data beyond what is permitted by the surveillance order, in a privacy-preserving way, such that E does not know the real identities of the users being surveilled, nor does E get to read the users' unencrypted data. Embodiments of the present invention also have inbuilt checks and balances to require unsealing of surveillance orders at the appropriate times, thus enabling accounting of the surveillance operation to verify that lawful procedures were followed, protecting users from government overreach, and helping law enforcement agencies and companies demonstrate that they followed the rule of law.

Panwar, Gaurav↗

Two-color high speed thermal imaging system for laser-based additive manufacturing process monitoring

Monitoring melt pool temperature in laser powder bed fusion by providing a build laser that produces a laser beam that is directed onto the melt pool and produces an incandescence that emanates from the melt pool, receiving the incandescence and producing a first image having a first spectral band and a second image having a second spectral band, and determining the ratio of said first image having a first spectral band and said second image having a second spectral band to monitor the melt pool temperature.

Calta, Nicholas P.↗

In operando, non-invasive state-of-charge monitoring for redox flow batteries

This document describes techniques and systems for in operando, non-invasive SOC monitoring of redox flow batteries. The described techniques and systems allow for accurate, inexpensive, portable, and real-time methods to measure the SOC of redox flow batteries. System operators can monitor the SOC by measuring an acoustic attenuation coefficient of the electrolyte in the redox flow battery. The acoustic attenuation coefficient is measured using an ultrasonic transducer attached to a probing cell, which is connected to an electrolyte flow of a redox flow battery. The acoustic attenuation coefficient provides an accurate, real-time SOC measurement that is generally insensitive to varying operational temperatures of the electrolyte solution.

25 ENERGY STORAGE↗

Integration of Nuclear Material Accounting Data and Process Monitoring Data for Improvement on Detection Probability in Safeguarding Electrochemical Processing Facilities (Final Technical Report)

The KAERI advanced spent fuel conditioning process (ACP) process is a critical component of the US- South Korean nuclear cooperation and the following “123 Agreement.” Its development has received considerable attention in both countries. The ACP is an electrochemical processing (pyroprocessing) that recycles over 96% of the used nuclear fuel (UNF). It is also intrinsically proliferation-resistant in theory. In normal operation, the U/TRU product is very hot radiologically. In addition, the Cm provides a high level of spontaneous neutrons, making the product unsuitable for weapon use. However, as pointed in some study, “the need for safeguards to protect against the diversion and misuse of separated plutonium applies essentially equally to all grades of plutonium.” As pointed by many studies, the well-established traditional Nuclear Material Accounting (NMA) approach cannot be directly applied to electrochemical processing because of the lack of an input accountability tank, the non-continuous material flow, and the unsatisfactory level of confidence in sampling methods. Therefore, nuclear safeguards remain a grand challenge in the developing of commercial electrochemical separations facilities, especially around the heart of such facilities, the electrorefiner (ER) systems. In contrast to NMA data, process monitoring (PM) data is normally an indirect measurement of the SNM and is acquired much more frequently. In a broad sense, PM includes monitoring by various types of equipment, e.g. radiation detectors, cameras, voltage, current sensors. Because it is already being collected by the operator, the additional cost to safeguards is low. It has long been believed that PM data can supplement NMA data and help improve safeguards, although the benefits are hard to quantify. The U.S. DOE’s Material Protection, Accounting, and Control Technology (MPACT) campaign has made substantial investments into innovative PM sensor technology and predictive model development for real- or near real-time measurement and prediction of molten salt density and level, salt composition and actinide concentration especially Pu, the cell voltage, and the cell current to supplement traditional NMA. For aqueous-based reprocessing facilities, it is reported that PM, integrated with traditional NMA, have a high detection probability for specific diversions. For electrochemical reprocessing, preliminary studies have shown that PM data can support traditional NMA in various ways by providing a basis to estimate some of the in-processing nuclear material inventories. Despite early success, further studies on fusion of PM data and NMA data are still needed, which is the goal of this proposed work.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Health monitoring device

Example aspects of a volatile organic compound detection device, a wearable health monitoring device, and a method of monitoring a user's health are disclosed. The volatile organic compound detection device can comprise a collector comprising a collector material configured to collect volatile organic compounds given off from a user's skin; a separator comprising a gas chromatography column configured to separate mixtures of the volatile organic compounds into their constituent chemicals; and an identifier comprising a detector and a processor, the detector configured to transduce the constituent chemicals into a signal, the processor configured to process the signal to identify specific volatile organic compounds indicative of a health condition.

42 ENGINEERING↗

The 2022 Hunga eruption exercises the nuclear explosion monitoring community

The 2022 Hunga eruption was a global event recorded by all three Comprehensive Test Ban Treaty Organization (CTBTO) International Monitoring System (IMS) geophysical waveform sensor technologies: seismic, infrasound, and hydroacoustic. Large volcanic eruptions are rare and additionally present an opportunity to test seismoacoustic detection, location, and identification methods for nuclear explosion monitoring.

58 GEOSCIENCES↗

From Count Rates to Quantifying Isotopic Activities – Field Analysis of Radiation Monitoring Data

The Nevada National Security Site (NNSS) provides a comprehensive bicoastal radiological and nuclear emergency response to United States Department of Energy/National Nuclear Security Administration. A major part of the support is to provide systematic radiological search for lost or stolen sources, Radiological search is a core competency of the NNSS with its origin dating back to nuclear weapons test era. Search operations from multiple platforms is the common thread among the various NNSS assets, which include Aerial Measuring System (AMS), Maritime Support Team (MST), National Capitol Response (NCR), National Search Team (NST) and Radiological Assistance Program (RAP). Information collected and analyzed during search operations add to the actionable intelligence for the law enforcement agencies and provide valuable guidance for the tactical resolution of a nuclear or radiological crisis. Search is an intelligence and situational awareness driven operation and most often called upon during a radiological emergency, however it can be brought into play to thwart a potential threat by providing monitoring and surveillance support. The Office of Nuclear Incident Response (NA-84) serves as the technical leader in responding to and resolving nuclear and radiological threats worldwide and integrates its efforts with other NNSA stakeholders (e.g., NNSA office of Defense Nuclear Non-proliferation NA-22). The response includes expertise in the areas of radiological search, render safe, and consequence management. This article will discuss the methodologies, tools, procedures, and techniques to extract maximum radiological characterization information (isotopic composition, activities for individual isotopes, threat assessment etc.) from field monitoring or Search operation data.

61 RADIATION PROTECTION AND DOSIMETRY↗

Methane monitoring and detection apparatus and methods

A low cost, low power, passive optical methane monitoring system for fixed-position installation at oil and gas production well pads and gathering centers is disclosed. The optical methane monitoring system disclosed can be a scannable field of view Near Infrared (NIR) filter photometer to detect and quantify methane concentration in a two dimensional or a three dimensional grid above and around a facility. A randomized fiber optic bundle is disclosed that can be used to direct the total optical power from a collection lens to two or more isolated optical channels. Band pass filters isolate a desired wavelength range for transmission measurements for the two or more channels. Also disclosed is an absorption algorithm which accounts for variable background spectral intensity as well as correcting for water vapor and overall scattering effects to measure methane concentration for a given field of view.

Lievois, John↗

Operational Focused Data Analytics for Optimizing Radiation Portal Monitor-Based Nuclear Smuggling Detection Systems at Global Ports of Entry

The National Nuclear Security Administration’s Office of Nuclear Smuggling Detection and Deterrence has deployed a fleet of radiation portal monitors (RPMs) across the world at global ports of entry including seaports, airports, and land border crossings. These RPMs are integrated into radiation detection systems (RDS) that also include fixed cameras, optical character recognition (OCR) systems, primary scanning systems (e.g., X-ray or gamma-ray), and secondary scanning systems (e.g., spectroscopic radiation portal monitors, portable radiation detection systems). The data from these sensing technologies is collected at the Central Alarm Station (CAS) where servers and computers reside to control and operate the system. Operators utilize the data collected by the CAS and declared cargo information to make decisions on how to respond to an alarm.This work explores the use of CAS-located data, looking at both the sensor data streams and operator inputs, to perform analysis which supports customs and border protection agencies to improve training capability and operational effectiveness. We focus on analyzing site level effectiveness and behavior by rolling up CAS-located data collected from individual occurrences. To-date, more than 15 sites (e.g., seaports, airports, border crossings) have been analyzed in this manner with the goal of understanding system operations to verify effectiveness and recommend potential improvements. This work first aims to provide background information on relevant CAS-located data sources and our current operational system analytics process including example results. After summarizing our current analytic techniques, we discuss how the future data analytics systems can provide key benefits to improving operational performance while minimizing the burden these detection systems place on operators.

Kuhn, Michael↗

Systems and methods for monitoring fuel cell membrane degradation

Systems and methods for real-time continuous monitoring of fuel cell membrane degradation are provided. At least one microsensor can be used as an inline sensor integrated at the cathode exhaust and/or the anode exhaust of a fuel cell, such as a proton exchange membrane fuel cell (PEMFC)). The microsensor can monitor the PEMFC degradation status by sensing the emission of fluoride.

Dong, Dongmei↗

Large Volume Airborne Contamination Monitoring To Support Nuclear Processes' Deactivation and Decommissioning

Current D and D operations at Hanford have demonstrated a flaw in the current state of the art capability of defining airborne contamination boundaries - Airborne particulate emissions of Pu-239 from CM2H operations on the Hanford Pu Finishing Plant were detected well beyond areas controlled for airborne Pu, putting numerous workers at risk for radiological assimilations - Current air samplers and CAM systems were surveying insufficient volumes of air to accurately predict where respiratory protection was required - Hanford is located in a high radon environment, making air monitoring for alpha emitting actinides challenging in high alpha radon induced backgrounds. - Inexpensive HEPA based home and industrial air purifiers filter significantly higher volumes of air than commercially available continuous-air monitoring (CAM) systems. - Inexpensive models capable of filtered air volumes exceeding 1000 times that of a CAM. - Detector system can be built to detect x-rays generated from actinide decay. - Branching ratios of x-rays are 4 orders of magnitude more intense from Plutonium decay than its gamma emissions. - Detector system can be a low resolution systems, as x-ray region of interest is not terribly congested. - Detection systems evaluated will be designed based on slabs of NaI or pixelated NaI or CsI panels. - Simple graphical user interface software will be developed to operate the detection system. - Concept is to deploy some of these air-purifying systems in nonradiological areas around SRNL to confirm radon can be rejected with confidence. - Generate some filters contaminated with plutonium via electroplated Pu or lab generated simulated particles. - then deploy units in known airborne radiological environments to establish systems ability to accurately measure actinide based hot particles Lab analyses will follow up the system analyses to ensure hot particles were correctly identified. Analysis by Scintillation: - Application of scintillation media to the surface of the filters is being explored. - Evaluating slabs of ZnS(Ag), application of powdered ZnS(Cu) and spray on Perkin Elmer Enhance. - Scintillation events would then be digitized with a digital camera and quantified. - Comparing against sensitivity of a PMT or SiPD readout. - Currently evaluating a Thorlabs 8 Megapixel Monochrome Scientific CCD Camera, hermetically sealed cooled package with a wide angle lens. - Wide angle lens allows complete view of HEPA filter from 7 inches away. - Images taken of glow in the dark paint, as well as plutonium-induced fluorescence. - Plutonium was flamed mounted on a 1 inch diameter stainless steel planchet, covered with a layer of mylar and a section of scintillating ZnS obtained from Eljon. - Currently working on reducing signal-to-noise levels to boost sensitivity. - Dark box to hold contaminated or electroplated source covered filters under fabrication. Analysis by x-ray Spectroscopy: - Branching ratios for x-ray emissions from Plutonium isotopes are orders of magnitude more intense than gamma-ray emissions. - The nuclear databases are incomplete on the branching ratios of some of the isotopes. - Evaluating some custom built SrI2 x-ray spectrometers vs a conventional windowed NaI detector. - SrI2 detectors are carbon-composite-windowed 51 mm x 51 mm. - MCNP calculations to establish self absorbance of filter media on 17 keV x-ray. Radon Rejection: - Activated charcoal pre-filter acts as a Radon trap. - Adding a time lapse feature to camera to aid in radon rejection. SRS Plutonium Fuel Form D and D Operations: Currently deploying air sampler to D and D operation of Pu-238 facility at SRS to generate some field samples to analyze.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Augmented Monitoring and Condition Assessment Program for SNF Wet Storage Life Extension - 20489

Approximately 27 MTHM of spent nuclear fuel (SNF) owned and managed by the U.S. Department of Energy, Office of Environmental Management is stored in the L Basin at the Savannah River Site (SRS). This 'DOE SNF' is comprised of approximately 12,000 aluminum-clad, aluminum-based fuel assemblies (∼7 MTHM), and approximately 2000 non-aluminum fuel assemblies (∼20 MTHM). A program is in progress to perform Non-Destructive Examination (NDE) of the fuel and their storage containers to characterize the materials' condition, and to evaluate the effects of service to enable continued safe wet storage of the SNF. The Augmented Monitoring and Condition Assessment Program (AMCAP), a two-part program to develop and implement remote underwater Non-Destructive Examination of the aluminum SNF, and of the containers of the non-aluminum SNF, respectively, is aimed at the characterization and evaluation of corrosion degradation of aluminum fuel and container materials. The predominant design of the aluminum SNF (ASNF) stored in L Basin is the Materials Test Reactor (MTR) equivalent design, a plate fuel design. These SNF are stored in 5'' diameter tubes or 5'' x 5'' squares (called bundles) that are nominally 12' or up to 14' long. The SNF is de-bundled and inspected using a custom-designed MTR Fuel Inspection Table. The inspection table provides for indexed fuel positioning for a video camera examination with controlled lighting. A total of 10 of the SNF originating from foreign research and test reactors were selected for examination based on burnup, enrichment, and prior damage caused by service/storage history. A special inspection campaign of these 10 assemblies is in progress. The observed corrosion damage included minor to moderate attack from general corrosion, pitting, crevice, end grain and galvanic corrosion. Example results from the completed inspections are shown and discussed. The focus is a comparison of the as-received condition versus the as-found current storage condition that will serve to validate Water Chemistry and Corrosion Monitoring Programs. The non-aluminum SNF (NASNF) stored in L Basin are of diverse design that includes various geometries with claddings of stainless steel, Zircaloy, and Hastelloy. The fuel core materials include uranium alloys, oxides/mixed oxides, and carbides. These SNF materials, originating from early experimental and test reactors, are in various physical forms including single fuel elements and cut pieces. The fuel is stored in L Basin in various configurations including in direct bundled storage in aluminum tubes and in isolation cans that are in the bundles or in a larger over-size storage container (OSC). Concern with inside-out corrosion and the potential loss of configuration control and ability to handle the storage containers prompted the development of remote NDE methods that include visual and UT technologies to assess the condition of the containers. Candidate stored materials were selected for a special inspection campaign; the development of the NDE methods for the inspection for galvanic, crevice and sediment-induced corrosion (inside-out) are discussed. A summary of the SNF storage in L Basin at the SRS, and an overview of the AMCAP to enable continued safe storage of DOE SNF are described. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Success Using A Granular-Activated Carbon Filtration Swab to Rehabilitate Westbay{sup R} Multi-level Groundwater Monitoring Wells at the INL - 20544

In November 2015, tetrachloroethylene (PCE) was discovered in groundwater samples collected from a Westbay{sup R} multi-level groundwater monitoring well at the Idaho National Laboratory (INL).a Subsequent investigation determined that PCE was not present in the groundwater. The detected PCE was instead due to inadvertent contamination of the internal tubing fluid in the Westbay well-monitoring system, which is isolated from the surrounding groundwater. Further investigation showed that three of the 11 Westbay wells at the INL contained PCE-contaminated tubing fluid at concentrations above the U.S. Environmental Protection Agency's maximum contaminant level for drinking water (5 μg/L). Loose sediment at the bottom of some Westbay wells was also found to contain PCE; the three wells were then identified for rehabilitation as part of the INL well maintenance program. The unique construction of the Westbay wells - i.e., the small diameter (5.72 cm [2.25 in.]) and the depths of the tubing fluid ranging from 144.8 to 419 m (475 to 1,376 ft) below ground surface - posed unique challenges to the rehabilitation. Because the tubing fluid provides structural integrity, the fluid cannot be removed and then replaced without damaging the integrity of the Westbay well. Additionally, the small diameter of the systems and the associated depths limit the availability of equipment that can be used for the rehabilitation. After an evaluation of potential methods, it was determined that the use of an in-well, custom-fabricated, granular-activated-carbon filtration swab deployed via a wire line would provide the safest and most cost-effective method for rehabilitation. Westbay well rehabilitation started at well MIDDLE-2051 in late June 2018 and paused in December 2018 for the season. The PCE concentration in the tubing fluid at MIDDLE-2051 was initially reduced to a maximum concentration of 3.81 μg/L from a maximum of 642 μg/L, while the concentration of PCE in the sediment had been reduced from 5,360 to 2,270 μg/kg. Sampling was performed at MIDDLE-2051 again in August 2019, and the tubing fluid increased to a maximum concentration of 45.4 μg/L, while the concentration in the sediment decreased further to 1,890 μg/kg due to desorption of PCE from the sediment to the tubing fluid. Rehabilitation resumed at well MIDDLE-2050A in late August 2019, and the PCE concentration in the tubing fluid had been reduced to a maximum concentration of 19.0 μg/L. Although the method has been shown to be time-consuming, it has proven to be effective and safe for personnel performing the work and to the integrity of the well. Future sample data results at all wells will help determine an estimated completion of the rehabilitation. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Characterization of Non-Science Grade DESI CCDs and Creating Additional ICARUS Monitoring Metrics for Data Quality

DESI, otherwise known as the Dark Energy Spectroscopic Instrument, is an astronomical project measuring millions of optical spectra to characterize Dark Energy. The survey has been running for 3 years. My work delves into the data taking/analysis side of the DESI CCDs (Charge-Coupled Devices) which will help in swapping out broken CCDs on the instrument. Additionally, I worked on making new metrics for ICARUS, Imaging Cosmic and Rare Underground Signals for their monitoring of run data. This paper will talk about the types of characterizations done for DESI and additional metrics for data quality and tools used for ICARUS monitoring.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗