Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MAST”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

Ionospheric E-Region Response to Solar-Geomagnetic Storms Observed by TIMED/SABER and Application to IRI Storm-Model Development

The large thermospheric infrared radiance enhancements observed from the TIMED/SABER experiment during recent solar storms provide an exciting opportunity to study the influence of solar-geomagnetic disturbances on the upper atmosphere and ionosphere. In particular, nighttime enhancements of 4.3 um emission, due to vibrational excitation and radiative emission by NO+, provide an excellent proxy to study and analyze the response of the ionospheric E-region to auroral electron dosing and storm-time enhancements to the E-region electron density. In this paper we give a status report of on-going work on model and data analysis methodologies of deriving NO+ 4.3 um volume emission rates, a proxy for the storm-time E-region response, and the approach for deriving an empirical storm-time correction to International Reference Ionosphere (IRI) E-region NO+ and electron densities.

Mertens, Christopher J.↗

Analysis of N-Nitrosodimethylamine and N-Nitrodimethylamine in Groundwater

A method for the analytical determination of N-nitrosodimethylamine (NDMA) and N-nitrodimethylamine (DMN) at parts-per-trillion (ppt) concentrations in groundwater is reported. The method uses a solid phase extraction (SPE) cartridge containing 2 g of activated coconut charcoal to extract a 500-mL water sample. NDMA and DMN are eluted from the SPE cartridge using acetone. The acetone is concentrated and brought to a final volume of 1.0 mL, which results in a theoretical 500-fold concentration of the analytes. The extracts are analyzed by gas chromatography (GC) with a nitrogenphosphorous detector (NPD), which is a highly sensitive and relatively inexpensive technique. The measured extraction efficiencies averaged 61 percent for NDMA and 74 percent for DMN. Extraction efficiencies were independent of NDMA and DMN concentrations from 40 to 2000 ppt. Several samples could be extracted then analyzed in a single day with the use of an extraction manifold and GC autosampler. A reporting limit of 10 ppt for NDMA and DMN was achieved. The MDLs for NDMA and DMN were 6.4 and 5.8 ppt, respectively. A typical turn-around time from beginning of extraction to reporting was 4 h. The method avoids the use of halogenated solvents, such as dichloromethane, and subsequent solvent exchange procedures necessary for use of the NPD detector.

Greene, Ben↗

Determination of Silicon in Hydrazine

Inductively coupled plasma-mass spectrometry (ICP-MS) is a highly sensitive technique sometimes used for the trace determination of silicon at a mass-to-charge (m/z) ratio of 28, the most abundant natural isotope of silicon. Unfortunately, ICP-MS is unable to differentiate between other sources of m/z 28 and false positive results for silicon will result when other sources of m/z 28 are present. Nitrogen was a major source of m/z 28 and contributes to the m/z 28 signal when hydrazine sample or nitric acid preservative is introduced into the plasma. Accordingly, this work was performed to develop a sample preparation step coupled with an ICP-MS analysis that minimized non-silicon sources of m/z 28. In the preparatory step of this method, the hydrazine sample was first decomposed predominately to nitrogen gas and water with copper-catalyzed hydrogen peroxide. In the analysis step, ICP-MS was used without nitric acid preservative in samples or standards. Glass, a potential source of silicon contamination, was also avoided where possible. The method was sensitive, accurate, and reliable for the determination of silicon in monopropellant grade hydrazine (MPH) in AF-E-332 elastomer leaching tests. Results for silicon in MPH were comparable to those reported in the literature for other studies.

McClure, Mark B.↗

Vivid Motor Imagery as an Adaptation Method for Head Turns on a Short-Arm Centrifuge

Artificial gravity (AG) has been proposed as a potential countermeasure to the debilitating physiological effects of long duration space flight. The most economical means of implementing AG may be through the use of a short-radius (2m or less) centrifuge. For such a device to produce gravitational forces comparable to those on earth requires rotation rates in excess of 20 revolutions per minute (rpm). Head turns made out of the plane of rotation at these rates, as may be necessary if exercise is combined with AG, result in cross-coupled stimuli (CCS) that cause adverse side effects including motion sickness, illusory sensations of motion, and inappropriate eye movements. Recent studies indicate that people can adapt to CCS and reduce these side effects by making multiple head turns during centrifuge sessions conducted over consecutive days. However, about 25% of the volunteers for these studies have difficulty tolerating the CCS adaptation paradigm and often drop out due to motion sickness symptoms. The goal of this investigation was to determine whether vivid motor imagery could be used as a pseudostimulus for adapting subjects to this unique environment. Twenty four healthy human subjects (14 males, 10 females), ranging in age from 21 to 48 years (mean 33, sd 7 years) took part in this study. The experimental stimuli were produced using the NASA JSC short-arm centrifuge (SAC). Subjects were oriented supinely on this device with the nose pointed toward the ceiling and head centered on the axis of rotation. Thus, centrifuge rotation was in the body roll plane. After ramp-up the SAC rotated clockwise at a constant rate of 23 rpm, producing a centrifugal force of approximately 1 g at the feet. Semicircular canal CCS were produced by having subjects make yaw head turns from the nose up (NU) position to the right ear down (RED) position and from RED to NU. Each head turn was completed in about one second, and a 30 second recovery period separated consecutive head movements. Participants were randomly assigned to one of three groups (n=8 per group): physical adapters (PA), mental adapters (MA), or a control group (CG). Each subject participated in a one hour test session on each of three consecutive days. Each test session consisted of an initial (preadaptation) period during which the subject performed six CCS maneuvers in the dark, followed by an adaptation period with internal lighting on the centrifuge, and a final (postadaptation) period during which six more CCS maneuvers were performed in the dark. For the PA group, the adaptation period consisted of performing 30 additional CCS maneuvers in the light. For the MA and CG group the centrifuge was ramped down to 0 rpm after the pre-adaptation period and ramped back up to 23 rpm before the post-adaptation period. For the both of these groups, the adaptation period consisted of making 30 CCS maneuvers in the light with the centrifuge stationary (so no cross-coupling occurred). MA group subjects were instructed to vividly imagine the provocative sensations produced by the preadaptation CCS maneuvers in terms of magnitude, duration, and direction of illusory body tilt, as well as any accompanying levels of motion sickness. CG group subjects were asked to answer low imagery content questions (trivial pursuit) during each adaptation period head turn. During the 30 second recovery following each head turn, psychophysical data were collected including self reports of motion sickness, magnitude and direction estimates of illusory body tilt, and the overall duration of these sensations. A multilevel mixed effects linear regression analysis performed on all response variables indicated that all three groups experienced some psychophysical adaptation across the three test sessions. For illusory tilt magnitude, the PA group exhibited the most overall adaptation, followed by the MA group, and the CG group. The slopes of these adaptation trajectories by group over day were significantly diffent from one another. For the perceived duration of sensations, the CG group again exhibited the least amount of adaptation. However, the rates of adaptation of the PA and the MA groups were indistinguishable, suggesting that the imagined pseudostimulus appeared to be just as effective a means of adaptation as the actual stimulus. The MA group's rate of adaptation to motion sickness symptoms was also comparable to the PA group. The use of vivid motor imagery may be an effective method for adapting to the illusory sensations and motion sickness symptoms produced by cross-coupled stimuli. For space-based AG applications, this technique may prove quite useful in retaining astronauts considered highly susceptible to motion sickness as it reduces the number of actual CCS required to attain adaptation.

Newby, N. J.↗

Safety Sufficiency for NextGen: Assessment of Selected Existing Safety Methods, Tools, Processes, and Regulations

NextGen is a complex socio-technical system and, in many ways, it is expected to be more complex than the current system. It is vital to assess the safety impact of the NextGen elements (technologies, systems, and procedures) in a rigorous and systematic way and to ensure that they do not compromise safety. In this study, the NextGen elements in the form of Operational Improvements (OIs), Enablers, Research Activities, Development Activities, and Policy Issues were identified. The overall hazard situation in NextGen was outlined; a high-level hazard analysis was conducted with respect to multiple elements in a representative NextGen OI known as OI-0349 (Automation Support for Separation Management); and the hazards resulting from the highly dynamic complexity involved in an OI-0349 scenario were illustrated. A selected but representative set of the existing safety methods, tools, processes, and regulations was then reviewed and analyzed regarding whether they are sufficient to assess safety in the elements of that OI and ensure that safety will not be compromised and whether they might incur intolerably high costs.

Xu, Xidong↗

IceCube: CubeSat 883-GHz Radiometry for Future Ice Cloud Remote Sensing

Ice clouds play a key role in the Earth's radiation budget, mostly through their strong regulation of infrared radiation exchange. Accurate observations of global cloud ice and its distribution have been a challenge from space, and require good instrument sensitivities to both cloud mass and microphysical properties. Despite great advances from recent spaceborne radar and passive sensors, uncertainty of current ice water path (IWP) measurements is still not better than a factor of 2. Submillimeter (submm) wave remote sensing offers great potential for improving cloud ice measurements, with simultaneous retrievals of cloud ice and its microphysical properties. The IceCube project is to enable this cloud ice remote sensing capability in future missions, by raising 874-GHz receiver technology TRL from 5 to 7 in a spaceflight demonstration on 3-U CubeSat in a low Earth orbit (LEO) environment. The NASAs Goddard Space Flight Center (GSFC) is partnering with Virginia Diodes Inc (VDI) on the 874-GHz receiver through its Vector Network Analyzer (VNA) extender module product line, to develop an instrument with precision of 0.2 K over 1-second integration and accuracy of 2.0 K or better. IceCube is scheduled to launch to and subsequent release from the International Space Station (ISS) in mid-2016 for nominal operation of 28 plus days. We will present the updated design of the payload and spacecraft systems, as well as the operation concept. We will also show the simulated 874-GHz radiances from the ISS orbits and cloud scattering signals as expected for the IceCube cloud radiometer.

cloud ice remote sensing↗

Elaborated Odor Test for Extended Exposure

Concerns were raised when incidental exposure to a proprietary bonding material revealed the material had an irritating odor. The NASA-STD-6001B document describes a supplemental test method option for programs to evaluate materials with odor concerns (Test 6, Odor Assessment). In addition to the supplemental standard odor assessment with less than 10 seconds of exposure, the NASA White Sands Test Facility (WSTF) Materials Flight Acceptance Testing section was requested to perform an odor test with an extended duration to evaluate effects of an extended exposure and to more closely simulate realistic exposure scenarios. With approval from the NASA Johnson Space Center Industrial Hygienist, WSTF developed a 15-minute odor test method. WSTF performed this extended-duration odor test to evaluate the odor and physical effects of the bonding material configured between two aluminum plates, after the safety of the gas was verified via toxicity analysis per NASA-STD-6001B Test 7, Determination of Offgassed Products. During extended-duration testing, odor panel members were arranged near the test material in a small room with the air handlers and doors closed to minimize dilution. The odor panel members wafted gas toward themselves and recorded their individual assessments of odor and physical effects at various intervals during the 15-minute exposure and posttest. A posttest interview was conducted to obtain further information. Testing was effective in providing data for comparison and selection of an optimal offgassing and odor containment configuration. The developed test method for extended exposure is proposed as a useful tool for further evaluating materials with identified odors of concern if continued use of the material is anticipated.

Buchanan, Vanessa D.↗

Advancing Technologies for Climate Observation

Climate research needs Accurate global cloud ice measurements Cloud ice properties are fundamental controlling variables of radiative transfer and precipitation Cost-effective, sensitive instruments for diurnal and wide-swath coverage Mature technology for space remote sensing IceCube objectivesDevelop and validate a flight-qualified 883 GHz receiver for future use in ice cloud radiometer missions Raise TRL (57) of 883 GHz receiver technology Reduce instrument cost and risk by developing path to space for COTS sub-mm-wave receiver systems Enable remote sensing of global cloud ice with advanced technologies and techniques

radiative transfer↗

CRMS Special Case Event Identification & Course of Action Concept of Operations

This package presents the CRMS identification of special Conjunction cases and the documented process for handling these special cases. The presentation is beneficial to anyone considering performing Conjunction Assessment by identifying and understanding the types of special cases that requires attention.

Duncan, Matthew G.↗

Downwelling Far-Infrared Emission Spectra Measured by FIRST at Cerro Toco, Chile and Table Mountain Facility, CA

The Far-Infrared Spectroscopy of the Troposphere (FIRST) instrument is a fourier transform spectrometer developed to measure the far-infrared portion of the Earth's longwave spectrum. Specifically, the purpose is measurement of the important, yet under-investigated 100 to 1000 cm-1 band. Presented here are measurements made by FIRST at two successful deployments in a ground-based configuration to measure downwelling longwave radiation. The initial deployment was to Cerro Toco, Chile. FIRST operated from August to October, 2009 as part of the Radiative Heating in Underexplored Bands Campaign (RHUBC-II) campaign. After recalibration, FIRST was deployed to the Table Mountain Facility from August to October, 2012. Dry days for both campaigns were chosen for analysis ? 09/24/2009 and 10/19/2012. Also available from both deployments are coincident radiosonde temperature and water vapor vertical profiles used as inputs to radiance calculations performed by two platforms, the AER Line-by-Line Radiative Transform Model (using the AER line database), and a research platform, MRTA utilizing HITRAN 2012. Thus, we have three streams of data for the closure studies, and results of the comparisons are presented showing good agreement in the optically thick regions of 200-400 cm-1 and 600-800 cm-1. Differences between measured and coincident calculated spectra between 400 and 600 cm-1 are less than 10 mW/m^2/sr/cm-1. Uncertainties accounted for in this study include uncertainty from multiple detectors, water vapor, temperature, line strength and width as presented in HITRAN 2012, and due to internal heating caused by black bodies. The residuals fall within the root-sum-square envelope of the uncertainties.

J Mast↗

Understanding Pilot Breathing – A Case Study in Systems Engineering

This position paper assesses the Pilot Breathing Assessment’s driving requirement to collect missing data on pilot breathing pressure, flow, rate, oxygen and CO2, simultaneously with aircraft data. Repeat measures data were collected over a 2-year period from 5 NASA test-pilots flying 8 flight profiles on NASA F-15 and F/A-18 (A, B) aircraft. This Pilot Breathing Assessment Systems Engineering (PiBASE) position paper serves as a case-study of systems engineering that accommodates the human as a distinct part of the whole. It acknowledges that a successful machine design intended for human use must include human systems biology/physiology as an integral part of planning, design, and implementation.

Pilot Breathing Assessment Systems Engineering↗

Spacecraft Loads and Acoustic Measurement (SLAM)

The lack of measured flight vibration data for payloads launching on ESPA rings, is preventing Goddard engineers from developing lighter, less expensive, small satellites. The SLAM ESPA Payload will capture and transmit in- flight structural loads and vibroacoustic levels encountered by ESPA spacecraft. The SLAM Team will work with NASA's Launch Service Program (LSP) to validate the ESPA flight environment data and potentially update ESPA payload interface requirements. Goddard engineers will use the updated ESPA payload flight environment data to develop mass efficient ESPA payloads. Scientists can use the resources saved by these efficient small satellites, to develop more and/or larger science instruments.

Keon Harmon↗