Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “MAGNETRONS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 865 records · Page 48

Degradation of Poly- and Perfluoroalkyl Substances (PFAS) in Water via High Power, Energy-Efficient Electron Beam Accelerator

The goal of the 2-year workplan was to see if electron beam (EB) could be used to break down a sub-set of the larger chemical family of per and polyfluoroalkylated substances (PFAS) in an energy efficient and economical manner when compared to conventional water treatment technologies. Year one (Y1) work focused on sample EB treatment work in the Fermi National Accelerator Laboratory’s (FNALs) Accelerator Applications Demonstration and Development (A2D2) EB accelerator. While there are reportedly thousands of types of PFAS, for the point of most of the work herein, a small subset was examined, typically perfluorooctane sulfonate (PFOS) and perfluorooctanoate (PFOA). PFOA and PFOS are two of the most well studied PFAS and are studied for baseline evaluations and are considered most useful. The work from Y1 provided information about the optimal operating parameters and additives to use when treating PFOS and PFOA via EB. The data were then used to see where in a water treatment system an EB accelerator would be best suited to treat PFAS. A conventional water treatment technology, GAC, was then compared to e-beam treatment technology with respect to energy and costs for treatment. In year two (Y2), several conventional e-beam accelerator designs, and FNAL’s developmental compact SRF accelerator design, were evaluated for their suitability in PFAS treatment, from an energy efficiency and cost standpoint. Several EB parameters were evaluated and optimized for the removal of PFOA and PFOS from water at normal pressure and temperature, measured as total PFAS removal. Under the optimized test conditions both PFOA showed complete destruction to inorganic fluoride, and PFOS to inorganic fluoride and sulfate, with mass balance. The effect on PFAS removal relative to solution pH, total EB dose, EB dose rate, dissolved oxygen concentration (DO), temperature, and initial PFAS concentration were evaluated. In general, PFOA was easier to destroy than PFOS. Degradation products, typically observed under less-than-optimal EB conditions, provided insight to degradation mechanisms. Products were identified to rule out possible deleterious biproduct formation. The water radiolysis radical reaction kinetics with PFOS and PFOA were not dependent on the initial concentration over 5-orders of magnitude from 2 μg/L to 20 mg/L. This is thought to be because there was an overabundance of the reactive water radiolysis radicals relative to PFAS molecules and largely attributed to aqueous electrons. The reaction rates appeared to be diffusion limited. Testing at higher concentrations (100-200 mg/L) showed a decrease in removal efficiency, suggesting alternative kinetics, possibly second order rates, at higher concentrations. In all, we successfully defined a set of optimal EB parameters to treat PFOA and PFOS at concentrations of 20 mg/L in water with destruction efficiencies near 100%. We further tested the optimized EB parameters with other types of PFAS, including shorter and longer fluorocarbon chain homologs of PFOA and PFOS, and PFAS with alternative functional groups such as sulfonamides. Based on our results EB can be optimized as an effective destructive technology for removing PFAS from water. The conditions optimized for PFOA and PFOS were less effective with ultra-short fluorocarbon compounds like TFMS, PFES, PFPS and PFBS, and likely require re-optimization of parameters to them. In all, it was determined that from a cost and energy efficiency standpoint, EB would be best applied to waste streams with relatively high concentrations of PFOS and PFOA and is not as cost effective as GAC treatment for removing low concentrations of PFAS from water. Higher concentrations of PFAS can be found in the wastewater of conventional treatment processes such as RO and IE and therefore EB may be used to supplement such treatment technologies. Some real-world IE regeneration wash water and RO reject water containing higher concentrations of PFAS and obtained from pilot scale industrial wastewater treatment system at a fluorochemical manufacturing facility, showed that EB could remove PFAS from such types of wastewaters. The IE regenerant wash water appeared to be the most efficient of the two types of wastewaters tested. However, some further optimization of the EB parameters for the specific PFAS types present in those wastewaters may be required. Also, the effects of co-present TOC and mineral salts should be considered during such optimization efforts. From the experimental Y1 results it was seen that the aqueous electron drives degradation of the PFAS. In a hypothetical water treatment skid using EB for PFAS destruction the parameters of the system should be optimized to promote aqueous electron production. Before EB treatment, the PFAS should be preconcentrated when possible, the pH should be raised to pH 10 or higher to enhance aqueous electron production, and the water should be nitrogen purged to remove dissolved oxygen to minimize aqueous electron scavenging. An excel spreadsheet was created that calculates optimal conditions based on inlet PFAS concentration and desired outlet concentration, by optimizing the accelerator power, dose rate, water treatment rate, pH and dissolved oxygen levels to reach the desired endpoint. Given this information on accelerator operating conditions five different EB accelerator systems were compared. One EB system was a continuous-wave, linear superconducting accelerator being designed at Fermilab. Three other EB systems (IMPELA at 5% and 25% duty factor and the ILU-14) were normal conducting pulsed linear accelerators. The fifth system was an IBA Rhodotron which is a normal conducting, circular, continuous-wave accelerator. The accelerator efficiency (% of the incoming power that is used in water treatment) was the dominating factor in accelerator choice. The radio frequency (RF) power supply and the accelerator design (superconducting versus warm technology) drive the accelerator efficiency. The IBA Rhodotron was seen to be the most energy efficient commercially available technology with a wall-plug (total) power efficiency of 43% at 400 kW. The Fermilab design, with a prototype for a different application currently being fabricated, was the most energy efficient at 55% when driven by a Klystron RF power supply and as high as 77% when powered by a magnetron. As the Fermilab design was the most energy efficient by approximately 10-30%, further design work was done on the accelerator and beam delivery system specific to the destruction of PFAS in water. The Fermilab design is unique from industrial accelerators in that is superconducting. Superconducting technology allows for the acceleration of electrons without losses. The accelerator must be cooled to below the point where it is superconducting and is operated around 4 degrees Kelvin. The bulk of the design work for the accelerator is on making the accelerator as energy efficient as possible so that it does not require liquid helium and can be cooled with conduction cooling via cryocoolers. Final design work resulted in an EB accelerator that would operate at minimally 200 kW and 10 MeV. Prototype construction would cost $\$ $7.8 million dollars when driven by a Klystron power supply. A second version of the same accelerator would cost $\$ $5.5 million dollars when driven by a magnetron that is still under development. The commercially available 300 kW IBA Rhodotron cost was estimated at approximately $\$ $9 million. While it is hard to directly compare, an operational GAC system used by 3M for groundwater treatment capital cost (2022 dollars) was estimated to cost $\$ $3.3 million. While the capital expense of the EB accelerator systems was higher than GAC, the accelerator EB treatment would result in destruction of the PFAS and not just sequestration of PFAS to form a new waste stream that requires further treatment or disposal. The operating cost to destroy the PFAS via 400 kw EB system was less than $\$ $1000/kg of PFAS destroyed when treating at a 20 mg/L PFAS concentration, compared to GAC with operating costs that calculated at $\$ $27,530 per kg of PFAS sequestered when treating 100 μg/L PFOA and PFOS combined concentration.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

More efficient microwave-power transmission

Small improvements in magnetron, receiving diodes, radiating antennas, and circulator sections of components add sizable improvement in microwave system efficiency. Further improvements in future are possible by adding new materials and designs to RF-to-dc converter-or removal of circulator, power supply and redesigning of magnetron to tolerate low or high power levels.

Dickinson, R. M.↗

Microwave beamed power technology improvement

The magnetron directional amplifier was tested for (1) phase shift and power output as a function of gain, anode current, and anode voltage, (2) background noise and harmonics in the output, (3) long life potential of the magnetron cathode, and (4) high operational efficiency. Examples of results were an adequate range of current and voltage over which 20 dB of amplification could be obtained, spectral noise density 155 dB below the carrier, 81.7% overall efficiency, and potential cathode life of 50 years in a design for solar power satellite use. A fabrication method was used to fabricate a 64 slot, 30 in square slotted waveguide array module from 0.020 in thick aluminum sheet. The test results on the array are discussed.

Brown, W. C.↗

Satellite Power Study (SPS) concept definition study (Exhibit D). Volume 1: Executive summary

Efforts concentrated on updating of the Rockwell reference concept, definition of new system options, studies of special emphasis topics, further definition of the transportation system, and further program definition. The Rockwell reference satellite concept has a gallium arsenide (GaAs) solar cell array having flat concentrators with an effective concentration ratio of 1.83at end of life. Alternatives to this concept includes solid state power amplifiers or magnetrons for dc/RF conversion and multibandgap solar cells for solar to dc energy conversion. Two solid state concepts were studied. It was determined that the magnetron approach was the lowest mass and cost system.

Hanley, G. M.↗

Performance and impedance studies of thin, porous molybdenum and tungsten electrodes for the alkali metal thermoelectric converter

Columnar, porous, magnetron-sputtered molybdenum and tungsten films show optimum performance as alkali metal thermoelectric converter electrodes at thicknesses less than 1.0 micron when used with molybdenum or nickel current collector grids. Power densities of 0.40 W/sq cm for 0.5-micron molybdenum films at 1200 K and 0.35 W/sq cm for 0.5-micron tungsten films at 1180 K were obtained at electrode maturity after 40-90 h. Sheet resistances of magnetron sputter deposited films on sodium beta-double-prime-alumina solid electrolyte (BASE) substrates were found to increase very steeply as thickness is decreased below about 0.3-double-prime 0.4-micron. The ac impedance data for these electrodes have been interpreted in terms of contributions from the bulk BASE and the porous electrode/BASE interface. Voltage profiles of operating electrodes show that the total electrode area, of electrodes with thickness less than 2.0 microns, is not utilized efficiently unless a fairly fine (about 1 x 1 mm) current collector grid is employed.

Wheeler, B. L.↗

A vacuum (10(exp -9) Torr) friction apparatus for determining friction and endurance life of MoSx films

The first part of this paper describes an ultrahigh vacuum friction apparatus (tribometer). The tribometer can be used in a ball-on-disk configuration and is specifically designed to measure the friction and endurance life of solid lubricating films such as MoS(x) in vacuum at a pressure of 10 exp -7 Pa. The sliding mode is typically unidirectional at a constant rotating speed. The second part of this paper presents some representative friction and endurance life data for magnetron sputtered MoS(x) films (110 nm thick) deposited on sputter-cleaned 440 C stainless-steel disk substrates, which were slid against a 6-mm-diameter 440 C stainless-steel bearing ball. All experiments were conducted with loads of 0.49 to 3.6 N (average Hertzian contact pressure, 0.33 to 0.69 GPa), at a constant rotating speed of 120 rpm (sliding velocity ranging from 31 to 107 mm/s due to the range of wear track radii involved in the experiments), in a vacuum of 7 x 10 exp -7 Pa and at room temperature. The results indicate that there are similarities in friction behavior of MoS(x) films overs their life cycles regardless of load applied. The coefficient of friction (mu) decreases as load W increases according to mu = kW exp -1/3. The endurance life E of MoS(x) films decreases as the load W increases according to E = KW exp -1.4 for the load range. The load- (or contract-pressure-) dependent endurance life allows us to reduce the time for wear experiments and to accelerate endurance life testing of MoS(x) films. For the magnetron-sputtered MoS(x) films deposited on 440 C stainless-steel disks: the specific wear rate normalized to the load and the number of revolutions was 3 x 10 exp -8 mm exp 3/N-revolution; the specific wear rate normalized to the load and the total sliding distance was 8 x 10 exp -7 mm exp 3/N-m; and the nondimensional wear coefficient of was approximately 5 x 10 exp -6. The values are almost independent of load in the range 0.49 to 3.6 N (average Hertzian contact pressures of 0.33 to 0.69 GPa).

Miyoshi, Kazuhisa↗

The UAH/NSSTC Advanced Radar for Meteorological and Operational Research (ARMOR)

The past four years have seen a marked enhancement in meteorological-radar infrastructure and radar-research capability at the University of Alabama-Huntsville (UAH) and National Space Science and Technology Center (NSSTC; a collaborative center supported by UAH, NASA-MSFC and USRA). This enhancement is due in part to the development of the ARMOR C-band dual-polarimetric radar facility (amongst other mobile radar facilities also discussed in this conference). The ARMOR radar, located at Huntsville International Airport, originated as a unique collaboration between university, government and broadcast meteorologists (the very first of its kind relative to concurrent operational, research and broadcast applications of dual-polarimetry). Contributions from each of these entities resulted in the upgrade of a surplus National Weather Service WSR-74C radar to a research-grade C-band polarimetric radar. The initial upgrade of the radar took place in late 2004 with WHNT-TV purchase and installation of a SIGMET (now Vaisala) Antenna Mounted Receiver (AMR), RVP8/RCP8 radar processor/antenna controller, new radome, and a new dual-polarimetric antenna feed. The AMR enabled simultaneous transmit and receive (STSR) capability and hence collection of dual-polarimetric moments. During the initial part of the AMR upgrade the original WSR74C antenna reflector and 250 kW magnetron-transmitter were used. In early 2005, a new 350 kW magnetron transmitter was purchased from Baron Services and installed. In October of 2006 a new high performance parabolic antenna and dual-pol feed (Seavey) were installed together with a new Orbit pedestal. ARMOR Radar control and data delivery are facilitated through the use of T-1 lines that run from the airport to both NSSTC and WHNT-TV in Huntsville. Under current operating protocols radar scanning and product development are completed at NSSTC, though meteorologists at WHNT-TV can also control the radar if desired. In its default scanning configuration the radar is operated 24/7 in an STSR polarimetric rain scan mode alternating with a surveillance scan on a 5-minute cycle; scans separated by 2.5 minutes. Every 2.5 minutes the raw data arrive at NSSTC where they are corrected in real time for attenuation and differential attenuation (using a constrained ZDR/Z-PHI approach) and new products are generated (e.g., rain maps, hydrometeor identification etc.). The raw and derived products are archived at NSSTC and also redistributed locally in real time over the network within NSSTC to the National Weather Service Forecast Office in Huntsville (collocated with NSSTC) for operational use. During periods of interesting weather the radar is often operated in full, sector, or RHI volume modes from NSSTC and coincident with UAH mobile radar or NWS NEXRAD radar platforms as needed.

Petersen, Walter A.↗

Molten Target Sputtering: Non-Conventional Method for High Mobility Si0.15Ge0.85 Growth at 500°C

Since electrons travel over 100 times faster in Silicon-Germanium (SiGe) than in pure Si due to the low effective masses associated with Ge and SiGe-based devices continue to replace Si-based solid-state electronic devices. SiGe thin film on sapphire was successfully grown at 890°C, using a magnetron sputtering system within heteroepitaxial framework. However, SiGe growth at 890oC is a costly and difficult process to produce as a uniform wafer for semiconductor device manufacturing due to thermal soak times, and geometric thermal shadowing from the wafer holder. To leverage the semiconducting capabilities of SiGe, novel processing techniques for SiGe film growth with decreased thermal loading are required. This paper introduces the Molten Target Sputtering (MTS) method that produces high mobility SiGe on sapphire below 500°C. This non-conventional method has the advantage of high kinetic energy, high-energy latency, and high flux density of sputtered atoms by combining benefits of both magnetron sputtering and thermal evaporation. For the MTS method, a 1~2 mm (depth and width) ring-shaped groove was cut between the center magnet and surrounded by electromagnets creating a circular cavity between the copper plate and source target materials that melt the target material. The SiGe grown from the MTS shows continuous morphology and 99.7% single crystal Si0.15Ge0.85 films. The Hall electron mobilities of the Si0.15Ge0.85 are 456 sq. cmV(exp -1)s(exp -1) and 123.9 sq. cmV(exp -1)s(exp -1) at 5.59 x 10(exp 18) cubic cm and 3.5 x 10(exp 20) cubic cm carrier concentration at 22.38°C, respectively. This is approximately 5.5 times higher than that of Si and similar to the Ge value at equivalent carrier concentrations and temperatures.

High mobility SiGe↗

Development of SRF monolayer/multilayer thin film materials to increase the performance of SRF accelerating structures beyond bulk Nb

The minimization of cost and energy consumption of future particle accelerators, both large and small, depends upon the development of new materials for the active surfaces of superconducting RF (SRF) accelerating structures. SRF properties are inherently a surface phenomenon as the RF only penetrates the London penetration depth ?, typically between 20 and 400 nm depending on the material. The greatest potential for dramatic new performance capabilities lies with methods and materials which deliberately produce the sub-micron-thick critical surface layer in a controlled way. Thus, two opportunities arise for the use of SRF thin ?lms as single layer superconductor or multilayer Superconductor-Insulator-Superconductor structures: SRF properties are inherently a surface phenomenon, and when other technological processes are optimized, the fundamental limit to the maximum supportable RF ?eld amplitude is understood to be the ?eld at which the magnetic ?ux ?rst penetrates into the surface, Hc1. Niobium, the material most exploited for SRF accelerator applications, has Hc1 ? 170 mT, which yields a maximum acceler?ating gradient of less than 50 MV/m. Thus, new materials must be investigated to push this limit to the desired range. Although many compounds have shown higher critical superconducting transition temperature (Tc), their critical ?eld (Hc1) is lower than niobium. To circumvent this issue, a Super?conductor/Insulator/Superconductor (S-I-S) multilayer ?lms approach has been proposed to achieve performance in excess of that of bulk Nb. In this system, the critical ?eld is enhanced and the ?uxon penetration delayed by using, on top of the Nb surface, a superposition of superconductor layers, each less than a penetration depth in thickness, separated by a dielectric layer a few nanometers thick. For bulk type-II superconducting materials, vortex entry occurs at surface magnetic ?eld Hc1. The key aspect of Gurevich's analysis is the recognition that vortex entry is inhibited if the surface layer thick?ness (d) of the superconductor is less than the penetration depth, ?. The overlayer provides magnetic screening of the underlying Nb with the attenuation factor exp(d/ ?0). The Nb surface can remain in the Meissner state at ?elds much higher than in bulk due to the increase of the parallel Hc1 in a thin ?lm. This could potentially lead to further improvement in RF cavity performance using the bene?t of the higher-Tc superconductors without being limited by their lower Hc1. Niobium on copper (Nb/Cu) technology for superconducting cavities has proven over the years to be a viable alternative to bulk niobium. However the deposition techniques used for cavities, mainly magnetron sputtering, have not yielded, so far, SRF surfaces suitable for high ?eld performance. High quality ?lms can be grown using methods of energetic condensation, such as Electron Cy?clotron Resonance (ECR) Nb ion source in UHV and High Power Impulse Magnetron Sputtering (HiP?IMS) with energetic ions only and neutral atoms signi?cantly blocked. The main advantages of these techniques are the production of higher ?ux of ions with controllable incident angle and kinetic energy and the absence of macroparticle production. The project in general, is focusing onto understanding the physics underlying the RF superconduc?tivity in layered structures and developing SRF material ?lms suitable as substrate and S-I-S multilayer structures. In ?rst hand, the primary focus is to understand the physics governing the relationship be?tween growth conditions, ?lm microstructure and RF performance for SRF materials produced by energetic condensation. The deposition by energetic condensation in UHV via ECR and HiPIMS are studied for Nb and B1 superconducting compounds on substrates with various lattice match and sur?face conditions (in-situ etching, high energy assisted atomic annealing, deposition temperature). The general energy-temperature zone model developed by André Anders is explored to de?ne the optimized coating conditions for ?lms suitable for single layer and multilayer SRF structures. The contribution of both the ion incident energy and the substrate lattice energy on the nucleation of the SRF materials considered, and some insulating materials (AlN and MgO) and the in?uence of the coating conditions on the resulting materials, superconducting and/or RF properties will be investigated. Attention is be given to minimize the residual stress (intrinsic and thermal) with the choice of lattice match between the ?lm and substrate materials, the coating temperature, and to evaluate the coating methods used in terms of conformality for 3D structures. In second hand, as a proof of concept, the coating condi?tions developed will be used to prepare multi-layer superconductor/insulator/superconductor (S-I-S) ?lms having high quality factor and high gradient breakthrough potential. A thick Nb ?lm (> 1µm) could be used as a substrate. Particular attention is given to the interface between superconducting and insulator ?lms. For this work, various material analyses techniques have been used to character?ize each type of thin ?lm material: electron backscatter di?raction (EBSD), X-ray di?raction (XRD), high-resolution scanning electron microscopy (SEM), transmission electron microscopy (TEM), stylus and AFM pro?lometry, secondary ion mass spectroscopy (SIMS), scanning auger microscopy (SAM). Superconducting and RF measurements are also performed (RRR, Tc, and low-temperature SRF sur- face impedance, SQUID-magnetometry). The insight gained from this project on the physics involved in RF superconductivity of layered structures open the way to enable major reductions in both capital and operating costs associated with future particle accelerators across the spectrum from low foot?print compact machines to energy frontier facilities. Realization of quality thin ?lm SRF cavities may dramatically change the cost structure of acceleration systems and signi?cantly improve performance consistency and reliability.

VALENTE-FELICIANO, Anne-Marie↗

SRF MULTILAYER STRUCTURES BASED ON NBTIN

For the past three decades, bulk niobium has been the material of choice for SRF cavities applications. In the recent years, RF cavities performances have approached the theoretical limit for bulk niobium. For further improvement of RF cavity performance for future accelerator projects, an interesting alternative has been recently proposed by Alex Gurevich with the Superconductor-Insulator-Superconductor multilayer approach, using the benefit of the higher critical field Hc2 of higher-Tc superconductors without being limited with their lower Hc1. JLab is pursuing this approach with the development of multilayer structures based on NbTiN via magnetron sputtering and High Power Impulse Magnetron Sputtering (HiPIMS). Insulators such as, AlN, Al2O3 and MgO are being investigated as candidates for the insulator layers. This paper present the preliminary results on the characteristics of NbTiN and insulator layers and a first attempt of a NbTiN-based multilayer structure on bulk Nb and thick Nb films.

Valente, Anne-Marie↗

Phase stability of a microtron driving a terahertz FEL

The phase stability of bunches accelerated by a magnetron-driven microtron-injector of a terahertz Free Electron Laser (FEL) has been studied to optimize the microtron regimes providing good operation of the FEL. The study is based on a simulation of the beam dynamics in the microtron considering 2-D motion of the electrons in the median plane. This allows the computation of the current loading the accelerating cavity as well as the output microtron current. The loading current has been used to calculate the frequency deviations caused by the incremental loading in the accelerating cavity coupled with the magnetron. Further computations using the 2-D simulation show noticeable phase oscillation of the accelerated bunch leaving the microtron on the macro-pulse front. The phase oscillation is in agreement with the measured one and affects the lasing in the microtron-based FEL. Optimization of the microtron regimes allows one to minimize the effect. As a result, the terahertz microtron-based FEL provides radiated macro-pulse energy up to 0.2 mJ tunable in the range of 0.85-3 THz with good stability. Results of the simulation and the measurements are presented in this article.

43 PARTICLE ACCELERATORS↗

Versatile device for in-situ discharge cleaning and multiple coatings of long, small diameter tubes

Electron clouds, which can limit machine performance, have been observed in many accelerators including RHIC at BNL. Additional concern for the RHIC machine, whose vacuum chamber is made from relatively high resistivity 316LN stainless steel, is high wall resistivity that can result in unacceptably high ohmic heating for superconducting magnets. The high resistivity can be addressed with a copper (Cu) coating; a reduction in the secondary electron yield can be achieved with a TiN or amorphous carbon (a-C) coating. Applying such coatings in an already constructed machine is rather challenging. We have been developing a robotic plasma deposition technique for in-situ coating of long, small diameter tubes. The technique entails fabricating a device comprising of staged magnetrons mounted on a mobile mole for deposition of about 5 ?m of Cu followed by about 0.1 ?m of a-C. As a first step, a 15-cm Cu cathode magnetron was designed, fabricated, and 30-cm long samples of the RHIC pipe have been coated with 2 ?m to 5.6 ?m of copper. Deposition rates of up to 92 A/sec with an average coating rate of 30 A/sec were measured. Effects on RF resistivity is also to be measured.

36 MATERIALS SCIENCE↗

Fabrication and characterization of lithium manganese nickel oxide sputtered thin film cathodes for lithium-ion batteries

Li-rich and stoichiometric Li1Mn1.5Ni0.5O4 (LMNO) cathode films have been prepared by magnetron sputtering. Sputtering from a Li stoichiometric target yields Li-rich films composed of spinel, layered and monoclinic phases. Films obtained from a Li deficient target are mostly made of a spinel phase and little layered material. The resulting cathode thin films have good capacity retention and very high rate capability. The reaction mechanism has been investigated by XRD and HRTEM and evidences the reversible formation of a spinel phase, as is also found for the powder samples. The film geometry enables to understand the effect of coatings (ZnO or LiPON). Coating high voltage cathodes reduces the coulombic losses but at the price of rate performance. Nonetheless, these coated sputtered electrode thin films offer a higher rate capability than other LMNO thin films obtained by other physical vapor deposition techniques.

25 ENERGY STORAGE↗

Ion acceleration and cooling in gasless self-sputtering

Copper plasma with hyperthermal directed velocity (8.8 eV) but very low temperature (0.6 eV) has been obtained using self-sputtering far above the runaway threshold. Ion energy distribution functions (IEDFs) were simultaneously measured at 34 locations. The IEDFs show the tail of the Thompson distribution near the magnetron target. They transform to shifted Maxwellians with the ions being accelerated and cooled. We deduce the existence of a highly asymmetric, pressure-driven potential hump which acts as a controlling"watershed" between the ion return flux and the expanding plasma.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

A synchronized emissive probe for time-resolved plasma potential measurements of pulsed discharges

A pulsed emissive probe technique is presented for measuring the plasma potential of pulsed plasma discharges. The technique provides time-resolved data and features minimal disturbance of the plasma achieved by alternating probe heating with the generation of plasma. Time resolution of about 20 ns is demonstrated for high power impulse magnetron sputtering (HIPIMS) plasma of niobium in argon. Spatial resolution of about 1 mm is achieved by using a miniature tungsten filament mounted on a precision translational stage. Repeated measurements for the same discharge conditions show that the standard deviation of the measurements is about 1-2 V, corresponding to 4%-8% of the maximum plasma potential relative to ground. The principle is demonstrated for measurements at a distance of 30 mm from the target, for different radial positions, at an argon pressure of 0.3 Pa, a cathode voltage of -420 V, and a discharge current of about 60 A in the steady-state phase of the HIPIMS pulse.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

A multi-slot surface coil for MRI of dual-rat imaging at 4T

A slotted surface coil inspired by the hole-and-slot cavity magnetron was developed for magnetic resonance imaging of obese rats at 4 T. Full-wave analysis of the magnetic field was carried out at 170 MHz for both the slotted and circular-shaped coils. The noise figure values of two coils were investigated via the numerical calculation of the quality factors. Fat simulated phantoms to mimic overweight rats were included in the analysis with weights ranging from 300 to 900 g. The noise figures were 1.2 dB for the slotted coil and 2.4 dB for the circular coil when loaded with 600 g of simulated phantom. A slotted surface coil with eight circular slots and a circular coil with similar dimensions were built and operated in the transceiver mode, and their performances were experimentally compared. The imaging tests in phantoms demonstrated that the slotted surface coil has a deeper RF-sensitivity and better field uniformity than the single-loop RF-coil. High quality images of two overweight Zucker rats were acquired simultaneously with the slotted surface coil using standard spin-echo pulse sequences. Experimental results showed that the slotted surface coil outperformed the circular coil for imaging considerably overweight rats. Thus, the slotted surface coil can be a good tool for MRI experiments in rats on a human whole-body 4 T scanner.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

(Ga,N) and (Cu,Ga) Co-Doped ZnO Films for Improving Photoelectrochemical Response for Solar Driven Hydrogen Production

In this study, Bandgap-reduced p-type ZnO thin films were synthesized through Cu and Ga co-doping. The ZnO:(Cu,Ga) films were synthesized by RF magnetron sputtering in O2 gas ambient at room temperature and then annealed at 500{sup o} in air for 2 hours. We found that the carrier concentration tuning does not significantly change the bandgap and crystallinity of the ZnO:Cu films. However, it can optimize the carrier concentration and thus dramatically enhance PEC response for the bandgap-reduced p-type ZnO thin films. The co-doped ZnO:(Ga,N) films were deposited by co-sputtering at room temperature, followed by post-annealing at 500{sup o}. We found that the ZnO:(Ga,N) films exhibited greatly enhanced crystallinity compared to ZnO:N films doped with pure N. Furthermore, the ZnO:(Ga,N) films showed much higher N-incorporation than ZnO:N films. As a result, the ZnO:(Ga,N) films showed significantly higher photocurrents than ZnO:N films.

08 HYDROGEN↗